Pt A, Ch 2, App 1

B) CLOSE-UP SURVEYS AND RELATED MEASUREMENTS (oil storage and liquefied gas storage)
ITEM INTERPRETATION FIGURE
Web frame ring (for oil storage) Refer to the definition given in Ch 2, Sec 6, Extent of area is shown as  in Ch 2, Sec
Tab 3 and Ch 2, Sec 6, Tab 4 6, Fig 1
“Adjacent structural members” means Location of points are given in Fig 3
plating and stiffeners of deck, bottom,
double bottom, sides and longitudinal
bulkheads in the vicinity of the web frame
ring
Transverse section Refer to the definitions given in Ch 2, Sec No figure
(for chemical and liquefied gas storage) 7, Tab 2
“Adjacent structural members” means
plating and stiffeners of deck, bottom,
double bottom, sides and longitudinal
bulkheads in the vicinity of the web frame
ring
Deck transverse This is the upper part of the web frame ring Extent of area is shown as  in Ch 2, Sec
including the adjacent structural members 6, Fig 1
(see meaning given above). Location of points are given in Fig 3
Deck and bottom transverses Refer to the definition given in Ch 2, Sec 6 Extent of area is shown as and  in
(for oil storage) Ch 2, Sec 6, Fig 1
Location of points are given in Fig 3
Transverse bulkheads “Complete” means the whole bulkhead Extent of area is shown as  in Ch 2,
including stringers and stiffeners and adja- Sec 6, Fig 1
cent structural members as defined above Location of points are given in Fig 8

“Lower part” means lower part of bulk- Extent of area is shown as  in Ch 2,


head up to 1/4 of ship’s depth or 2 metres Sec 6, Fig 1
above the lower stringer, whichever is the Location of points are given in Fig 8
greater (stringers, stiffeners and adjacent
structural members included)
Transverse bulkheads in cargo tanks for oil At least two points on each plate. Mini- Fig 9
storage with double hull mum 4 points on the first plate below
main deck
At least one point on every third stiffener
to be taken between each stringer
At least two points on each plate of string-
ers and girders, and two points on the cor-
responding flange. Additional points in
way of curved part
Two points of each diaphragm plate of
stools, if fitted.
Transverse bulkheads in ballast tanks for oil At least 4 points on plates between string- Fig 10
storage with double hull ers / longitudinal girders, or per plate if
stringers/girders not fitted
At least two points on each plate of string-
ers and girders, and two points on the cor-
responding flange. Additional points in
way of curved part
At least one point on two stiffeners
between each stringer / longitudinal girder
Adjacent structural members (for oil stor- On adjacent structural members one point No figure
age) per plate and one point on every third stiff-
ener/longitudinal
All plating and internal structures (for Refer to the definitions given in Ch 2, Sec 7 No figure
chemical and liquefied gas storage)

114 Bureau Veritas - Rules for Offshore Units December 2016