Calculation of Fuel Consumption of Boiler


D(igr − igs ) + D × Dpw (ibhs − igs )
B=
4.1868xQ ar η
D=35000kg/h
igr=3379.5kj/kg
igs=551.6kj/kg
Dpw=2%
Ibhs=1280.7kj/kg
Qqr=6044kCal/kg
η = 88%

Calculated: B=4467.7kg/s
Calculating fuel consumption: Bj=B(1-q4)=4467.7x(1-0.04)=4289kg/h

2. Calculation of Furnace outlet Flue Gas Volume


Furnace outlet Flue Gas Volume under Standard State: Vyo=8.53Nm³/kg
Set Flue Gas Temperature at Furnace outlet=850℃
So the actual flue gas volume at furnace outlet: Vy=Bi*Vyo* ( 273+850 )
/273/3600=4289*8.53*(273+850)/273/3600=41.8m³/s

3. Calculation of the Flue Gas Flow Rate at the Inlet Section of Separator
Average Section Area of Separator Inlet Section: 2.3*0.76=1.75 ㎡
So the average flow rate at the inlet of separator: ω1=41.8/1.75≈24m/s

4. Calculation of the Flue Gas Flow Rate at the Inlet of the Separator Central Cylinder
Inlet diameter of central cylinder: 1180mm
Inlet Section Area= 3.1416*1.18*1.18/4=1.094 ㎡
So flue gas rate at the inlet of central cylinder: ω2=41.8/1.094=38.2m/s

Note: Furnace outlet flue gas volume= Separator inlet flue gas volume= 41.8m³/s