Introduction
CADWorx Plant Design Suite is an integrated and complete software series for plant
design that provides intelligent drawing/database connectivity, advanced levels of
automation, and easy-to-use drafting tools. The comprehensive series of design tools
includes equipment, process and instrument diagrams, and design review, plus
automatic isometrics and bills of material.
This user's guide has the following changes for this release.
• DM ‐ 30476: Line Number not inheriting. - Custom Instruments are now able to
inherit line numbers.
• DM ‐ 30477: Unable to select the component after stretch In 2019 SP2, users are
now able to select a component after applying the STRETCH command on the
component.
• DM ‐ 30478: Custom instr. using insert valve function should honor instruments
properties. - Users can now create custom instruments using the insert valve
function, honoring the out‐of‐the‐box instrument characteristics which gives
greater flexibility in defining custom instruments. Custom instruments do not
inherit values for size or spec when you specify INST as the Table Name when
creating an item under the valve section. Instruments created with INST table
name will be assigned a PID program code of 302 and have instrument
properties.
• DM ‐ 30479: Removing Links removes Link Information. - Removing links
between drawings will not cause issues like losing information associated with
components on process lines.
• DM ‐ 30480: Inserting Reducer causes LINE_NUM field corrupt. - Inserting a
reducer will not corrupt the Line_Num field of Valve and Orifice Pair.
• DM ‐ 30481: Removing Links breaks Process Line Functionality. - P&ID 2019
SP2 allows you to remove the links between drawings so that users do not need
to redraw the components. P&ID will retain the information on the process line
and its associated components.
• DM‐30272: Issues with various Custom Data not showing up on BOM. - When
applying Custom Data information, not all Custom Data was appearing in the
Available Columns for CUSTOM FIELD in the Bill of Material Templates.
• DM‐30273: Cloudworx 6.4.2 won't allow launching CADWorx Structure into
CADWorx Plant. - It has been discovered that if users have Cloudworx 6.4.2, it
will not allow you to launch CADWorx Structure within CADWorx Plant. If
Structure was launched on its own, there was no issue.
• DM‐30274: Machine Bolts not inserting correctly. - If the user had Bolts set to
automatically insert, the Machine Bolt Head was shown the wrong way.
• DM‐30275: Intelligence Issue with HGENERIC attachment. - With HGENERIC
attachments created prior to CADWorx Plant 2018, users encountered a loss of
the long description when exploding the block in CADWorx Plant 2019.
• DM‐30277: Fatal Error stretching 2D Single Line Pipe components. - A user
encountered a fatal error when stretching 2D Single Line components using the
End Grip of piping components.
• DM‐30278: Issue w/ User Shapes created from Points/Polyline. - When
reopening the DWG, the USERSHAPES created from points/polylines did not
appear correctly and were completely different from the original User Shape.
• DM‐30279: Cannot create subfolders for Topworks. - Users were unable to create
subfolders in the Specification Editor for Topworks.
• DM‐30245: Stair Stringer Flat Bar Issue. - If a Stringer was changed to a Flat Bar
Structure Member Type, CADWorx Structure would add an extra tread. One side
of this tread would be connected properly to the stringer, but the other end was
halfway through the other side’s stringer.
• DM‐30246: Isogen Supplemental not working. - Isogen Supplementals would not
work if CADWorx Structure was loaded into CADWorx Plant.
• DM‐30247: Issue with Auto Bracing work point offset. - The "Auto Bracing Work
Point Offset" option in the Structure Setup Rule was not honoring the cardinal
point of the beams the bracing was being applied to.
• DM‐30248: Importing STAAD files into CADWorx Structure. - When importing a
specific STAAD file, the lengths of the members were being scaled but the
member size was importing correctly.
• DM‐30249: Disabling Layers in Clash Management. - When disabling unrelated
layers in the Clash Management Palette, clashes were being removed from the
Clash Manager display.
• DM‐30250: Client STP Export/Import in Structure Producing Errors. - When
exporting a Physical CIS/2 file and importing into a new drawing, errors were
• DM‐30276: Isogen Batch Issue for Stub Ends/ Lap Joints. - (*** Line(s) with errors
1) ***) was reported when continuation graphics were displayed (using IGB for
Stub Ends/ Lap Joint components).
• DM‐30282: CADWorx adding Isogen Supplementals incorrectly. - CADWorx was
adding extra Isogen Supplementals depending on the number of Line Numbers
used with IGB.