Sie sind auf Seite 1von 1

3 - Rosemount level products

3.10.2 Chamber

The chamber, also known as a cage or bridle, is


connected to the main process vessel such that the
liquid level in the chamber is the same as that in the
process vessel.

There are two process connections on the body of


the chamber which allow mounting to the vessel.

Figure 3.10.2: Showing the most common configurations

The instrument is mounted on top of the chamber


through the flanged or threaded instrument
connection. A threaded version is available for the
vertical float level switch.

Standard materials are carbon steel and stainless


steel, with other materials available upon request.

3.10.3 Chamber design

Rosemount 9901 chambers are designed to the


ASME B31.3 standard (B31.1 available), and are
Pressure Equipment Directive (PED) compliant.

Weld neck flanges and full penetration welds in


accordance with EN ISO 15614-1:2004 and ASME
Boiler and Pressure Vessel Code Section IX are used
through out. All welders are qualified to EN 287-
1:2004 and ASME Boiler and Pressure Vessel Code
Section IX.

All construction materials are fully traceable in


accordance with the EN 10204 type 3.1 certificate.

Every 9901 is hydro-tested as standard. A full range


of non destructive testing (NDT) is also available.

64

Das könnte Ihnen auch gefallen