Installation, Configuration and Commissioning
Guideline for
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
Contents
1. REFERENCE DOCUMENT ............................................................................... 4
2. INSTALLATION .......................................................................................... 4
2.1 AGS-20 Indoor Unit .................................................................................. 4
2.2 ASNK Outdoor Unit .................................................................................. 8
2.3 ODU Mounting ........................................................................................ 9
3. CONNECTION TO AGS-20 ............................................................................. 10
3.1 Connection via LAN 3 AGS-20 with ASNK ODU Sub Band High ................................ 11
3.2 Connection via LAN 3 AGS-20 with ASNK ODU Sub Band Low ................................ 12
3.3 Connection via LCT port AGS-20 .................................................................. 14
3.4 Connection via Console port AGS-20 ............................................................. 15
4. AGS-20 MICROWAVE LINK LINE UP .................................................................. 16
4.1 Delete the Default Radio Link .................................................................... 16
4.2 Radio Link ............................................................................................ 17
4.2.1 Create 1+0 Radio Link ....................................................................................... 18
4.2.2 Create 2nd 1+0 Radio Link (2+0) ............................................................................ 20
4.2.3 Manage Aggregation .......................................................................................... 21
4.2.4 Radio Parameters Configurations .......................................................................... 23
4.2.5 Channel Duplex Frequency Configuration ................................................................ 24
4.2.6 Transmitter Frequency ...................................................................................... 24
4.2.7 Set the Transmitter Power .................................................................................. 25
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
7. CREATE USERS MANAGEMENT ....................................................................... 38
7.1 Create Group NMS5UX ............................................................................. 39
7.2 Create User NMS5UX ............................................................................... 41
7.3 Activate SSH Protocol .............................................................................. 43
8. VIRTUAL LAN (VLAN) CONFIGURATION ............................................................. 44
9. ETHERNET PORT CONFIGURATION .................................................................. 47
9.1 Enable/Disable Port ................................................................................ 47
9.2 Modify LAN1/LAN2 Interface Type ............................................................... 48
9.3 Change MTU ......................................................................................... 48
10. QOS SETTING ......................................................................................... 50
11. SCAN MAC ADDRESS (FOR RFS) ..................................................................... 50
12. REVISION RELEASE NOTE ........................................................................... 53
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
1. REFERENCE DOCUMENT
No DOCUMENT NAME
2. INSTALLATION
Purpose of this document is to be use as reference to install, configure and commission AGS-20 in Indosat Ooredoo
network.
17
22 21 19 15 13
18 11 9 6 4 1
14 12 10 7 5 3 2
23 20 16
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
AGS-20 installation to the rack
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
AGS-20 Grounding
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
Typical Connection
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
2.2 ASNK Outdoor Unit
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
2.3 ODU Mounting
Integrated Antenna
STANDARD POLE MOUNTING KIT
1+0 1+1
1+0 1+1
For more details related to hardware installations please refer to mn00329e rev012.pdf
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
3. CONNECTION TO AGS-20
This section describe a step by step procedure to establish a connection to AGS-20 with factory default
configurations.
Needs instrument:
Personnel Computer (Laptop) installed with internet browser (Internet Explorer 9 or later, Firefox 4.0 or
later).
RJ45/LAN Cable
Serial Console Cable
All AGS-20 coming from factory comes with a default configurations. Ethernet connection between PC and AGS-20
can occur if both the IP Addresses belong to the same subnet.
The Ethernet ports available for the management of AGS-20:
• RJ45 LCT port with IP address 192.168.0.1 and netmask 255.255.255.0 (default settings)
• RJ45 LAN3 port with default address is
- 172.20.255.15 and netmask 255.255.0.0 if the IDU has been tested with an ASNK ODU Sub Band High.
- 172.20.254.14 and netmask 255.255.0.0 if the IDU has been tested with an ASNK ODU Sub Band Low.
When the connection is active the WebLCT is available in order to configure and manage unit and link. Through
the same ports, using HyperTerminal, a CLI session can be used to configure the Ethernet switch of the unit. The
maximum number of CLI sessions, active at the same time, is 7. The maximum number of WebLCT sessions active
at the same time is 4.
Connection using LAN 3 will allow users to access the AGS-20 web interface. From LAN 3 its feasible to access
Local and Remote AGS-20.
Connection using LCT port with default AGS-20 configuration will only allow user to access web interface of Local
AGS-20.
Connection using Console (RS323) port via serial cables will only allow users for access AGS-20 to Command Line
Interface (CLI).
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
3.1 Connection via LAN 3 AGS-20 with ASNK ODU Sub Band High
Steps below describe how to connect and access AGS-20 when it’s connect to an ASNK ODU Sub Band High with a
default configurations.
3. Open Command Prompt and ping the default IP address of LAN 3 172.20.255.15
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
6. In the WebLCT Login page, write:
username: admin
password: admin
7. Select or not the “Remember me” option to remind login data for further accesses.
8. Click Login button.
3.2 Connection via LAN 3 AGS-20 with ASNK ODU Sub Band Low
Steps below describe how to connect and access AGS-20 when it’s connect to an ASNK ODU Sub Band Low with a
default configurations.
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
3. Open Command Prompt and ping the default IP address of LAN 3 172.20.254.14
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
3.3 Connection via LCT port AGS-20
Steps below describe how to connect and access AGS-20 via LCT port with default configurations.
3. Open Command Prompt and ping the default IP address of LCT 192.168.0.1
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
6. In the WebLCT Login page, write:
username: admin
password: admin
7. Select or not the “Remember me” option to remind login data for further accesses.
8. Click Login button.
1. Connect the Serial RJ45 console cables to a PC and Console port of AGS-20.
2. Configure Putty connection parameter as example below:
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
3. Click “Open” button to open console section
4. At the prompt SM-OS login: write admin
5. At the prompt Password: write admin
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
3. Select ( ), in the Select Link to Delete table, the Radio Link(s) you want to delete.
4. Press Done.
The Radio Link is removed from the table Current Radio Configuration
WARNING Operation not available if all the Radio ports have been already used for other Links. This operation
allows defining Radio Links with native configuration (1+0, 2x(1+0), 2+0 XPIC).
In order to define a system radio configuration, it is necessary to create two or more Radio Links in native
configuration and, possibly, aggregate them.
The system radio configuration allowed for each type of AGS-20 Dual IF are indicated in Table 1.
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
Figure 2 1+0 Radio Link
In 1+0 configuration, only ODU A are used to connect to ODU with Vertical or Horizontal Polarization.
Refer to Link Budget.
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
3. Set, in the Select Link Type box, the Radio Link type: 1+0
5. In the table Available Radio, select the wished ODU’s according to the set type of Radio Link.
• 1+0, select an ODU A
6. Press Done.
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
4.2.2 Create 2nd 1+0 Radio Link (2+0)
1. Select Equipment > Radio Configurator.
2. Select Create New Link and press Next>.
3. Set, in the Select Link Type box, the Radio Link type: 1+0
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
4. Set, in the Link Name box, the SiteID FarEnd<->SiteID NearEnd_Polarization (V or H)
Example: 05MDN008-05MDN033_H
5. In the table Available Radio, select the wished ODU’s according to the set type of Radio Link.
• 1+0, select an ODU B
6. Press Done.
WARNING Operation meaningful only for Radio Links in configuration 2x(1+0) see Table 1. In these
configurations, the ports of the Radio Link(s) have to be aggregated in such a way to compose a single
Bundle routed into the same direction. Performs this configuration for Remote Station first and follow by
Local Station.
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
2. Select Manage Aggregation and press Next>.
3. Select the box with the value Select New Aggregator and choose the port you wish to aggregate (see
Table 1)
Press <Prev to cancel the operation.
4. Press Done.
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
In the table Current Radio Configuration, the column Radio Ports indicates the port where the Radio Bundle
terminates.
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
4.2.5 Channel Duplex Frequency Configuration
1. Select Radio > Radio Branch <link name>.
2. Set, in the Dplx Freq Selection table, the duplex frequency (MHz) for the available ODU’s.
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
4.2.7 Set the Transmitter Power
WARNING Asymmetrical configuration of the Radio Link between local and remote equipment, as regards
the value of Ptx / modulation, are not supported.
1. Select Radio > Radio Branch <link name>.
2. Select the ODU Powers tab.
The Max Ptx: <current value> dBm parameter indicates the maximum output power value at the transmitter
(Ptx nominal value).
3. To change the parameter, move the cursor on the wished value (refer to Link Budget).
4. Press Apply and confirm Yes.
Repeat the steps for Local/Remote station and perform antenna alignment to get the expected received signal as
in Link Budget.
Proceed as follows:
Connect a multimeter to BNC connector on the ODU for AGC measurement.
Adjust antenna pointing as soon as the maximum AGC voltage value is achieved.
The relationship between AGC voltage and received field is shown in Figure 3 and S/N Measurement value as
Table 2. The received field level has a tolerance of ±4 dB in the full temperature range.
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
Minimum S/N values at RX nominal level (-25dBm ÷ -40dBm)
Bandwidth
Modulation
7MHz 14MHz 28MHz 40MHz 56MHz
4QAM st 25 25 25 25 25
4QAM 25 25 25 25 25
16QAM 29 29 29 29 29
32QAM 33 33 33 33 33
64QAM 35 35 35 35 35
128QAM 35 35 35 35 35
256QAM 35.5 35.5 35.5 35.5 35.5
512QAM 38.5 38.5 38 38 38
1024QAM 38 39 39 38.5 38.5
2048QAM 38.5 38.5 38 38
5. ACM CONFIGURATION
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
2. To change the parameter, select the option:
• Disabled. Adaptive modulation disabled.
• Enabled. Adaptive modulation enabled.
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
Upper Profile = 512 QAM
Lower Profile = 16 QAM
3. Press Apply and confirm Yes.
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
Figure 5 In Band Scenario with connect to PDH Microwave Existing
Both Management and traffics share the same LAN interface to connect to the network with a specific VLAN
introduce for management.
WARNING Modification of parameters related to DCN/IP address configuration MUST be perform after antenna
alignment process successfully completed. Modification of Remote Station parameters will be configure first
before proceeding with Local Station.
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
6.2 Create VLAN for Management (only for In Band)
For AGS-20 using In Band Management VLAN ID for management will be use.
1. Select Base Band > Ethernet > VLAN.
2. Select the Static VLANs tab.
3. Press Add.
4. Set, in the box VLAN ID , 33 for Management VLAN used (refer to LLD).
5. Set, in the box VLAN Name as MNGT which represent the management VLAN.
6. Select in the box Member Ports the LAN ports to map the VLAN. For In Band configurations, LAN 3 and
ODU A need to be selected.
Issued by Approved by Date Page
Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 30 of 53
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
For AGS-20 which connected to MetroE or other vendors microwave equipment’s this LAN ports also need
to be a member ports of MNGT VLAN.
7. Select in the box Untagged Ports LAN 3.
8. Press Apply and confirm Yes.
The Static VLANs tab displays the row relevant to the new VLAN.
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
3. In the Net Mask box, set the mask for the network address definition (refer to LLD).
4. In the VLAN ID box, select the VLAN ID assigned for management (Example: 33).
5. In the Default Gateway box, set the default gateway IP address (refer LLD).
6. In the section Physical Interface, Port Alarm Report box select Disable.
7. Press Apply and confirm Yes.
8. Press Store and confirm Yes.
When the WEB page is opened, the Remote elements list area is hidden.
Press to hide the area. Press to display the area again.
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
3. Type, into the text box, the new name (alphanumeric string with minimum 1 and maximum 11
characters).
4. Press OK.
The application displays the new name of the station into the Remote elements list area.
The application removes the station from the Remote elements list area.
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
3. Select Equipment 2 and Press Remove.
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
6.4.3 Add new Equipment List
1. In the Remote elements list area, select the station to which the equipment has to be coupled.
2. Press Add (Element group).
3. Into the IP Address box, type the IP address of the Local equipment.
4. Set the Type of element box, selecting the option Managed By SCT for Local Equipment.
5. Press Ok.
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
6. Press Add (Element group).
7. Into the IP Address box, type the IP address of the Remote equipment.
8. Set the Type of element box, selecting the option Remote Link for Remote Equipment.
9. Press Ok.
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
6.5 Restart the Equipment
An equipment restart need to be done to in order to change to the DCN/IP address parameters sets.
Ensure all parameters are correct before performs a restart.
1. Select Base Band > DCN > MNGT Port Configuration.
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
6.6 LAN 3 Port Priority.
Users management allow to add more Users with different profile to access AGS-20. Each Users must associate to
a Group. All AGS-20 coming from factory comes with a default Users. Below are the default User available from
factory settings.
Users Password Group Profile CLI HTTP HTTPS SNMP FTP SFTP SSH
root admin123 Root Administrator
admin admin Admin Administrator SNMPv1
Table 3 Default Users
An additional Users need to be created as below:
Users Password Group Profile CLI HTTP HTTPS SNMP FTP SFTP SSH
NMS5UX SIAEMICR NMS5UX Administrator SNMPv1
Table 4 New Users
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
7.1 Create Group NMS5UX
WARNING It is possible to set a maximum of 10 groups. Logging as user admin to create new Group and User.
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
4. Set the profile to Administrator. The user with this profile can both verify the parameters and send
commands or change the equipment configuration with no exception.
5. Select all the protocols/interfaces available to the users associated to the group as Table 4.
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
7.2 Create User NMS5UX
3. Into the User box, type the user name NMS5UX. The parameter is Case Sensitive; pay attention to used
uppercase characters.
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
4. Press Change at the side of the Password parameter.
SIAEMICR
SIAEMICR
5. Into the New Password and Confirm New Password box, SIAEMICR and press OK. The parameter is Case
Sensitive; pay attention to used uppercase characters.
7. In the Timeout box, set the timeout of the WEB LCT session opened by the user to 3600 sec.
8. Press OK and confirm Yes.
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
7.3 Activate SSH Protocol
2. To modify SSH parameter, select the new value to “Enable” in correspondence of the wished protocol.
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
8. VIRTUAL LAN (VLAN) CONFIGURATION
CELCOM network work in customer bridge configurations which require each Virtual Lan ID (VLAN) need to be
register into Static VLAN Tables. Each traffic need to come with VLAN (802.1q) tagged frames.
3. Press Add.
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
The value of VLAN ID Stop must be greater than the value of VLAN ID Start and no VLAN with identifier
between Start and Stop values must not be present in the list.
The system creates a number of VLAN’s (and inserts the corresponding rows in the table) equal to the
difference between the values of the parameters VLAN ID Stop and VLAN ID Start, with progressive identifiers
from the lowest value to the highest value, and automatically assigns the corresponding VLAN Name using the
format <Label> <identifier>.
All the VLAN’s created automatically assume the same enabling policy for the transit of packets through the
ports of the Switch. The system guarantees the contemporary creation of maximum 100 VLANs.
A single VLAN, set, in the box VLAN ID, the identifier (between 2 and 4094) you wish to assign to the virtual
LAN. An identifier greater than that indicated in the field Max. VLAN ID cannot be used. Set, in the box
VLAN Name, the name (alphanumeric string, 32 characters at most) you wish to assign to the VLAN.
The system automatically suggests, as VLAN name, VLAN <identifier>. This name can be changed as you wish.
1. Activate ( ), in the box Member Ports, the ports enabled to the transit of packets with VLAN ID equal
to the VLAN’s one. For every port are indicated the port identifier (slot number/port number), the port
name LAN 1, LAN 2, LAN4 , LAN 5, LAN 6, LAN C, LAN D and ODUA. LAN3 only used for management
VLAN.
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
Issued by Approved by Date Page
Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 46 of 53
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
2. Press Apply and confirm Yes.
The port cannot transmit/receive traffic if the physical connection does not work (Link Status -Down).
3. Press Apply and confirm Yes.
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
9.2 Modify LAN1/LAN2 Interface Type
WARNING Operation available and meaningful only for the ports supporting both the Electrical and the Optical
interface LAN 1 and LAN2. This operation involves the re-configuration of the port parameters Auto Neg. and MTU
to the default value.
1. Select Base Band > Ethernet > Port Manager.
2. In the Media box, select the option:
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
2. Login to the equipment
3. Press Open
4. Login: admin
Password: admin
5. Run this script :
configure terminal
system mtu 2048
exit
exit
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
10. QOS SETTING
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
In the MAC Table window will show all mac address detected
5. Press Open
6. Login: admin
Password: admin
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
7. Run this script :
show mac-address-table
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved
12. REVISION RELEASE NOTE
53
Property of
Rev.01
Siae Microelettronica.
All rights reserved