Beruflich Dokumente
Kultur Dokumente
1. A dc power link is to be made between two islands separated by a distance of 24 miles. The
operating voltage is 500 kV and the system capacity is 600 MW. Calculate the maximum dc
current flow, and estimate the resistivity of the cable, assuming a diameter of 2.5 cm and a
solid (not stranded) wire. Use the following tables for resistivity
2. Calculate the resistance between points A and B (RAB) for the following resistor
networks
Factores Energéticos (Electrotecnia)
Tarea 1: Ejercicios de repaso y autoestudio
Fecha de entrega: 16 de agosto de 2019
Grupo de 2 alumnos.
3. Determine the current i in next figure and the power delivered by the 80 V source.
5. Complete the table of values for this circuit: Show how you obtain the table values
6. Complete the table of values for this circuit: Show how you obtain the table values
8. For the circuit shown in Fig. 11.22, find the complex power absorbed by the (a) 1 Ω
resistor; (b) −j10 Ω capacitor; (c) 5 + j10 Ω impedance; (d) source
10. A large AC electric motor under load can be considered as a parallel combination of
resistance and inductance:
Calculate the current necessary to power this motor if the equivalent resistance and inductance
is 20 Ω and 238 mH, respectively.
Factores Energéticos (Electrotecnia)
Tarea 1: Ejercicios de repaso y autoestudio
Fecha de entrega: 16 de agosto de 2019
Grupo de 2 alumnos.
11. Rank these five light bulb assemblies according to their total electrical resistance (in
order of least to greatest), assuming that each of the bulbs is the same type and rating
12. For next circuit find the voltage supplied by the source that allows a current of 60 mA in all
the circuit
Factores Energéticos (Electrotecnia)
Tarea 1: Ejercicios de repaso y autoestudio
Fecha de entrega: 16 de agosto de 2019
Grupo de 2 alumnos.
13. Determine the necessary resistor value to give the output voltage a phase shift of -64o:
Also, write an equation that solves for this resistance value (R), given all the other variables (f,
C, and phase angle θ).
Then, calculate the size of the capacitor necessary to “correct” the power factor to a value of
1.0, showing the best location of the capacitor in the circuit.
Factores Energéticos (Electrotecnia)
Tarea 1: Ejercicios de repaso y autoestudio
Fecha de entrega: 16 de agosto de 2019
Grupo de 2 alumnos.
15. An industrial installation that is powered by a three-phase network (380 VL / 220 VF)
operating at 60 Hz, has the following loads:
a) 3, three-phase motors 100 CV 380V with efficiency η= 92 % y cos ϕ= 0,8
b) 25, three-phase motors 10 CV 380V with efficiency η= 80 % y cos ϕ= 0,75
c) 90 heater 380 V,1200 W (resistive) each heater. (balanced connection)
d) 600 lighting bulbs 220 V, 60 W each bulb, cos ϕ= 0,85
735.39∗𝑃𝐶.𝑉
Note= Motor active power is (P) : 𝑊𝑀 = (𝑊𝑎𝑡𝑡𝑠)
𝜂
Condensador
Total Corregido
16. An inductive AC load draws 13.4 amps of current at a voltage of 208 volts. The phase
shift between line voltage and line current is measured with an oscilloscope, and
determined to be 23o. Calculate the following:
Apparent power (S) =
True power (P) =
Factores Energéticos (Electrotecnia)
Tarea 1: Ejercicios de repaso y autoestudio
Fecha de entrega: 16 de agosto de 2019
Grupo de 2 alumnos.
Reactive power (Q) =
Power factor =
An electrician suggests to you that the lagging power factor may be corrected by connecting a
capacitor in parallel with this load. If the capacitor is sized just right, it will exactly offset the
reactive power of the inductive load, resulting in zero total reactive power and a power factor of
unity (1). Calculate the size of the necessary capacitor in Farads, assuming a line frequency of
60 Hz.
17. Calculate all voltages, currents, and total power in this balanced Delta-Y system:
Vline =
Iline =
Vphase(source) =
Iphase(source) =
Vphase(load) =
Iphase(load) =
Ptotal =
18. An AC load exhibits a lagging power factor of 0.73 at 230 VAC and 315 amps. If the
system frequency is 60 Hz, calculate the following:
Apparent power (S) =
True power (P) =
Reactive power (Q) =
Θ=
Necessary parallel C size to correct power factor to unity =
19. Complete the table of values for this circuit, representing all quantities in complex-
number form: Show how you obtain the table values
Factores Energéticos (Electrotecnia)
Tarea 1: Ejercicios de repaso y autoestudio
Fecha de entrega: 16 de agosto de 2019
Grupo de 2 alumnos.
R1 L1 C1 C2 Total
V
I
Z
P (W)
Q (VAR)
S (VA)
20. The French TGV high-speed train absorbs 11 MW at 300 km/h (186 mi/h). The power supply module
is shown in Figure Below. The module consists of two 25-kV single-phase power stations connected at
the same overhead line, one at each end of the module. For the return circuits, the rail is used. However,
the train is designed to operate at a low speed also with 1.5-kV DC in railway stations or under the old
electrification lines. The natural (average) power factor in the AC operation is 0.8 (not depending on the
voltage).
Assuming that the overhead line equivalent specific resistance is 0.2 Ω/km and that the rail resistance could
a) be neglected, find:
b) The equivalent circuit.
c) The locomotive’s current in the condition of a 10 percent voltage drop.
d) The reactive power.
e) The supplied real power, overhead line losses, and maximum distance between two power stations
supplied in the condition of a 10 percent voltage drop when the train is located at the half-distance
between the stations.
f) Overhead line losses in the condition of a 10 percent voltage drop when the train is located at the half-
distance between the stations, assuming pf = 1. (The French TGV is designed with a state-of-the-art
power compensation system.)
g) The maximum distance between the two power stations supplied in the condition of a 10 percent voltage
drop when the train is located at the half-distance between the stations, assuming the DC (1.5-kV)
operation at one-quarter power.
h)
Factores Energéticos (Electrotecnia)
Tarea 1: Ejercicios de repaso y autoestudio
Fecha de entrega: 16 de agosto de 2019
Grupo de 2 alumnos.