Sie sind auf Seite 1von 24

MODULAR OPERATION

THEATER
STERILIE AND CONTROLLED WORKING ENVOIRMENT
Presentation by:
Sohail Siddqiue
Table of contents

 Why Modular OT
 Introduction to KLS Martin
 Equipment Range for Modular OT- Single Source
 Services Planning and concept
Classical Operation
Theater

 Non Steriled Environment


 Un controlled Environment
 Inaccessible to Equipment
The Solution which we have for you

 Sterile environment
 Everything is control ( humidity,
Air, Temperature)
 Soothing, energizing to surgeons
and Staff Patients.
 Safe and easy access to equipment
Introduction to KLS Martin

 Based in Germany
 Since 1923
 Manufactures and selling medical devices
 Implants
 Electrosurgery and laser devices
 Surgical instruments and sterilization containers
 Operating and examination lights, ceiling supply units
 Modular surgical systems
The Range We have

 Walls Panel
 Doors (Swivel and Sliding)
 Flooring, Ceiling Panels, Coving, Peripheral lights
 Control Panel
 X-Ray Viewer & Writing Board
 OT Lights
 OT Table
 Clean Air flow System (HEPA filter, HVAC, Return ducts)
Wall Panels
Galvanized Stainless
steel Steel

Stainless
steel
Glass
powder
coated
Glass Walls
FOR GREAT WORKABLE
ENVIRONMENT
Doors

 Single or Double Door


 Sliding or hinge
 Door Drives(Motion sensors ,foot switch, Code lockers
etc)
x
X-ray Viewer,
control panel
and other
related
accessories
FOR GREAT WORKABLE
ENVIRONMENT
Laminar-flow ceilings

Circular

Rectangular

Square
Air Flow System
KLS MARTIN PENDAND CEILING
SUPPLY SYSTEM
KLS MARTIN PENDAND CEILING 14
SUPPLY SYSTEM
➢ 30 kg to 1000 kg
➢ Adjustable lighting in the arm and base
➢ 1-5 Shelf's
➢ MediSound System
➢ Brake Guide
➢ E-Brake
MarLED
• 60,000 Hour life
• 1,60,000 Lux
• 190-290 mm
• 8 h battery backup
• 3,800 K / 4,300 K / 4,800 K
• 99 RI
Digital Camera surgi Cam SD
DIAMOND 18
19
Unique Features

1 Manual override

2 Bluetooth connection

3 Self-diagnostic program

4 Detachable back up control

5 Dual energy system


20
Unique Features

6 Mattress fixed by gel strip

7 Lifelong software support

8 Motion activation

9 Memory functions
21
Electrohydraulic Adjustments

Trendelen- / Reverse Lateral adjustment


Trendelenburg
Leg plate joints

Longitudinal shift Back section Height adjustment


Where is the Difference

Professional Reliable
Clear Concept
Planning Implementation

3 pillars of the
marWorld service
Defining the K.O. Financial framework
Requirements profile
criteria conditions

Project management Installation Final documentation


Thank You