Controlador de temperatura W1209

HOW TO USE:

Connect the power supply and equipment, the controller can be


powered to measure the temperature is displayed, press the SET button, the
display temperature flashes, press + - to set the desired temperature, after
setting finished, press SET to confirm the return, this When the controller
automatically executed by setting the relay off. The thermostat 20A relay
outputs to meet a variety of high-power loads, connect the control circuit
can be powered for the thermostat, then the display shows the ambient
temperature.

LEDs, LED and buzzer status descriptions:

LED:Flashes to indicate cooling or heating startup delay, Always indicate


the relay is closed

Digital Tube: Shows LL sensor opens, follow the instructions to connect


the sensor; display HH is beyond the measurement range thermostat will
forcibly disconnect relay; high-temperature alarm display ---

FUNCTION PARAMETERS:

Press SET 5 seconds to enter the main menu settings, press the + -
Switch P0 ... P6, or long press the SET button for 10 seconds without
motion controller automatically confirm return.

P0 refrigeration, heating mode:

Press SET 5 seconds display P0, press SET to set the operating
mode, press the + - switched to heating mode [H] [C] for cooling mode
press SET to return, long press SET or automatic confirmation button for
10 seconds without motion controller carry out.

Cooling mode: when the temperature measured value ≥ temperature set


point relay refrigeration, refrigeration starts; when the temperature
measured value ≤ temperature set point - hysteresis, the cooling relay is off,
the cooling off.
Heating mode: when the temperature set point temperature measurement
value ≤ heating relay, heater starts; when the temperature set point
temperature measurements ≥ + when hysteresis heating relay is off, the
heater is turned off.

P1 hysteresis setting:

Press SET 5 seconds display P0, press + - Switch to P1, press SET to set
back the difference, press + - to set hysteresis 0.1 to 15, press SET to return
after the completion of, or long press the SET button for 10 seconds
without motion controller automatically confirm completion.

Cooling mode: When the temperature measurement value ≥ set value, the
relay, refrigeration starts; when the temperature measured value ≤ set value
- the difference between the return, the relay off, cooling off.

Such as the environment is set at 30 ? 25 ?, hysteresis is set to 2 ?, after


power relay closed cooling starts, when cooling to 23 ?, the relay off
cooling off, this time due to the cooler has been broken Open the
temperature began to rise back up to the set value when 25 ?, the relay is
closed cooling starts again, so repeated cycle control temperature no higher
than 25 ?.

Heating mode: When the temperature measurement value ≤ set value, the
relay, the heater starts; when the temperature measured value ≥ set value +
return difference, the relay off, the heater is turned off.

Such as the environment is 10 ? setting is 25 ?, hysteresis is set to 2 ?, the


relay is closed after power heater starts, when heated to 27 ?, the relay off
the heater turned off, this time due to the heater has been broken Open the
temperature begins to drop, the moment when the set value dropped 25 ?,
the relay is closed heater starts up again, so repeated cycle control
temperature not lower than 25 ?.

P2 limit the maximum temperature settings:

To avoid misuse of others led to the setting temperature is too high risk
that the thermostat is set to a maximum limit function, define the scope of
the thermostat setting to control the maximum temperature set point.
Press SET 5 seconds display P0, press + - Switch to P2, press SET to set
the maximum limit, press + - to set up the set temperature, the maximum is
110, according to a SET return is completed, long press SET or 10 No
keystrokes second controller automatically confirm completion.

For example: Set the maximum temperature set point is 60 to 60 ? can only
be set if you want a higher temperature set point temperature to expand the
scope, you need to adjust the upper limit setting.

P3 lowest temperature setting limit:

To avoid misuse of others lead to the occurrence of ice blocking


temperature is too low, this thermostat has a lower limit on the lowest
setting function, defining a set range of the lowest temperature control
thermostat set point.

Press SET 5 seconds display P0, press + - Switch to P3, press SET to set a
minimum limit, press + - to set the minimum temperature can be set to a
minimum value of -50, press SET to return after the completion of, or long
press SET 10 seconds, the controller automatically confirm no keystrokes
to complete.

For example: Set the minimum temperature set point 2 can only be set to 2
? temperature set point if you want to expand the scope of lower
temperatures, you need to change the setting lower limit.

P4 temperature correction:

When measuring the temperature and the standard temperature


deviations due to user hardware or have special needs, you can use this
function to correct temperature = temperature correction after correction +
correction before the effective range of -7.0 to 7.0.

Press SET 5 seconds display P0, press + - Switch to P4, press SET to
correct, press + - to set the correction value, press SET to return upon
completion, or long press the SET button for 10 seconds without motion
controller automatically confirm completion .

For example, the normal display is 25 degrees; temperature correction


display 25 is 0 degree; temperature correction is displayed 26.5 1.5
degrees; temperature correction is displayed -1.5 23.5.
P5 delayed start time (unit: min):

When the cooling or heating needs work delay, delay function can be
opened to protect the life of equipment.

Press SET 5 seconds display P0, press + - Switch to P5, press SET to set
the delay start time is in minutes, press the + - Set 0-10 minutes, press SET
to return after the completion, or 10 seconds long press SET No keystrokes
controller automatically confirm completion

Cooling mode: the first powered, if the current temperature ≥ set value, the
cooler will not start cooling immediately after the set delay time required to
run start.

Heating mode: the first powered, if the current temperature ≤ set value, the
heater will not start heating immediately after the set delay time required to
run start.

When downtime cooler or heater starts between two adjacent delay start
time is greater than the set value, the cooler starts immediately.

Shutdown cooling or heating between two adjacent launch delayed start


time lapse is less than the set value, the need to start again after finished
running cooler set delayed start time for the device to start. Delay time is
counted down moments.

For example, the state set the delay under refrigeration for 5 minutes after
boot cooler startup delay, five minutes after opening the refrigerator to
reach the desired temperature when cooling is stopped, then the start time,
the next time the refrigerator immediately start the timer is complete work
unfinished end timing to wait timed to work, delay in the LED blinks.

Delay start is set to 0 equals off delay feature.


Functions and settings of the thermostat
At the beginning it is good to introduce thermostat control for easy work. The XH-
W1209 has three control buttons on the SET, + and -.If you press the SET button for 2
seconds enters the menu with seven options for setting the thermostat
(P0,P1,P2,P3,P4,P5,P6).

Here is basic schematic for temperture controller XH-W1209

In the temperature controller XH-W1209 menu will move with buttons + and – to select
the value or raising or lowering the temperature.

The red LED display indicates when the relay is activated.Always shines as long as the
relay is activated.If the relay is switched off LED off.

PO Heating or Cooling ?

Here we set the temeperature controller operation mode C- cooling , H-heating.

If you set Cooling (C) temperature controller will be activated relay when temperature
falls to the setpoint.

If you set Heating (H) temperature controller will be activated relay when temperature
raise to setpoint.
P1 – Hysteresis or Return diference set

This device model can value set by 0.1C and the lowest value is 0.1C.This is a very
useful feature for precise operation of the temperature controller.For example, if you set
the value of 1C and the desired temperature on the thermostat 20C relay will be
deactivated at 21C (20C+1C). The relay is activated again when the temperature drops
to 20C.

P2 – Highest temperature limit

You can set a maximum temperature limit, less than 110 degrees.

P3 – Lowest temperature limit

You can set minimum temperature limit more as 50 degrees.


P4- Temperature correct or calibration

Very good feature that lets you set your thermostat by certified accurate thermometer.

If you do not have a certified thermometer leave the value at 0C. Calibration allows you
to adjust the temperature in 0.1 increments.

P5-Delay starting time

In this step, you set the start delay in minutes 1-10 min.If you set 1min relay is activated

until one minute after reaching the set temperature.

P6-High temperature Alarm

The menu P6 initially turns OFF to ON and press the SET,then set the temperature at
which the alarm is activated. When is alarm activated display not showing temperature
only – - -.

Other info

The device has a low consumption of 25-35 mA at rest 50-75 mA when the relay is
activated.Be careful if the power supply voltage lower than 10V relay is not activated
although the LED shining