Sie sind auf Seite 1von 26

DESIGN OF FOOTING - F5

Size of Column ( Bc x Dc) = 0.23 x 0.38 m

Grade of Concrete ( fck ) = M 20

Grade of Steel ( fy ) Fe 500

Load coming to the Column ( P ) = 397.37 KN

Moment About X-Axis (Mx) = 3.71 KN-m

Moment About Z-Axis (Mz) = -2.30 KN-m

Horizontal reaction(Fx) = 0.00 KN

Horizontal reaction(FZ) = 0.00 KN

Height of excavation ( h ) = 2.00 m

Moment due to horizontal reaction(Fx*h) = 0.00 KN-m

Moment due to horizontal reaction(Fz*h) 0.00 KN-m

Total Moment Mx 3.71 KN-m

Total Moment Mz -2.30 KN-m

Total load on footing ( W = 1.1P ) = 437.10 KN

Safe bearing capacity of soil ( gsafe ) = 180 KN/m2

Area of Footing required (Areq = W /g safe) = 2.43 m2

Size of Footing Required (Bf x Df) = 1.56 x 1.56 m

Provided size of the footing = 1.6 X 1.6 m

Check for Bearing = 157.29 < 180


(P/A) + (6*Mx/Bf x Df ) + (6*Mz/Bf x Df )
2 2

Hence, the Footing is SAFE in bearing

Area of footing ( A ) = 2.56 m2

Projection beyond the column = 0 m

Size of Pedestal( Bp x Dp ) = 0.23 x 0.38 m

Net upward pressure due to fac. Load ( p ) = 232.83 KN/m2

Moment Mu = p Bf ( Bf - Bc)2/ 8 = 87.4 KN-m

Depth of footing required for B.M ( Dreq ) 140.68 mm


Dreq = SMu / 0.138 fck Bf

Provided depth of footing ( D ) = 400 mm B.M


2
Assume Cover for Footing (dc) = 50 mm Shear
:
Effective Depth ( d ) = 350 mm Punching
:
Edge depth of footing ( De ) = 400 mm

Mu / Bf d2 = 0.45

% of Steel Pt required from SP: 16 = 0.12

Required Steel (Ast req) = 672 mm2

Dia Of Bars Provided ( f ) = 10 mm

Area Of each 10 mm dia bar = 78.54 mm2

No: Of 10 mm dia bars (required) = 9 no.s

Spacing of main bars required ( Sreq ) = 178 mm

Provided @ Spacing ( S ) = 150 mm

Provided % of steel = 0.15

Provided Area of Steel = 837.76

No: Of 10 mm dia bars (provided) = 11.00

Hence Provide 10 tor @ 150 c/c Both ways

CHECK FOR ONE WAY SHEAR :

Shear force at critcle section ( Vu ) = 124.8 KN


Vu = p Bf [0.5 ( Bf - Bc )-d ]

Effective width at criticle section ( B'f ) = 1600 mm

Effective depth at criticle section ( d' ) = 350 mm

Nominal shear stress ( tv = Vu / B'f d' ) = 0.22 N/mm2

Permissible shear stress in concrete ( tc ) = 0.29 N/mm2 > 0.22

Hence, Footing is Safe in One way Shear.

CHECK FOR TWO WAY SHEAR :

Max. shear force ( VU ) 517.72 KN


p* [ L^2 - (Ped+d)*(Ped+d) ]
Perimeter of the Footing @ criticle section = 2620.00 mm
Bo = [ 2(Bc+ Dc)+4d]

Effective depth at criticle section ( d'' ) = 350.00 mm

Shear Stress (t v) = 0.56 N/mm2


Max allowble punching Shear stress ( t'c ) = 1.12 N/mm2 > 0.56
t'c = 0.25sqrt fck

Hence, Footing is Safe in Punching.


F12 SVPCL

2.56

Hence Safe

7.38189

safe
safe

safe.

12
N/mm2
DESIGN OF FOOTING - F5

Size of Column ( Bc x Dc) = 0.23 x 0.38 m

Grade of Concrete ( fck ) = M 20

Grade of Steel ( fy ) Fe 500

Load coming to the Column ( P ) = 295.7653 KN

Moment About X-Axis (Mx) = -3.4696 KN-m

Moment About Z-Axis (Mz) = 0.0535 KN-m

Horizontal reaction(Fx) = 0.00 KN

Horizontal reaction(FZ) = 0.00 KN

Height of excavation ( h ) = 2.00 m

Moment due to horizontal reaction(Fx*h) = 0.00 KN-m

Moment due to horizontal reaction(Fz*h) 0.00 KN-m

Total Moment Mx -3.47 KN-m

Total Moment Mz 0.05 KN-m

Total load on footing ( W = 1.1P ) = 325.34 KN

Safe bearing capacity of soil ( gsafe ) = 180 KN/m2

Area of Footing required (Areq = W /g safe) = 1.81 m2

Size of Footing Required (Bf x Df) = 1.35 x 1.35 m

Provided size of the footing = 1.4 X 1.4 m

Check for Bearing = 143.43 < 180


(P/A) + (6*Mx/Bf x Df ) + (6*Mz/Bf x Df )
2 2

Hence, the Footing is SAFE in bearing

Area of footing ( A ) = 1.96 m2

Projection beyond the column = 0 m

Size of Pedestal( Bp x Dp ) = 0.23 x 0.38 m

Net upward pressure due to fac. Load ( p ) = 226.35 KN/m2

Moment Mu = p Bf ( Bf - Bc)2/ 8 = 54.22 KN-m

Depth of footing required for B.M ( Dreq ) 118.46 mm


Dreq = SMu / 0.138 fck Bf

Provided depth of footing ( D ) = 300 mm B.M


Assume Cover for Footing (dc) = 50 mm Shear
:
Effective Depth ( d ) = 250 mm Punching
:
Edge depth of footing ( De ) = 300 mm

Mu / Bf d2 = 0.62

% of Steel Pt required from SP: 16 = 0.148

Required Steel (Ast req) = 518 mm2

Dia Of Bars Provided ( f ) = 10 mm

Area Of each 10 mm dia bar = 78.54 mm2

No: Of 10 mm dia bars (required) = 7 no.s

Spacing of main bars required ( Sreq ) = 200 mm

Provided @ Spacing ( S ) = 150 mm

Provided % of steel = 0.21

Provided Area of Steel = 733.04

No: Of 10 mm dia bars (provided) = 10.00

Hence Provide 10 tor @ 150 c/c Both ways

CHECK FOR ONE WAY SHEAR :

Shear force at critcle section ( Vu ) = 106.16 KN


Vu = p Bf [0.5 ( Bf - Bc )-d ]

Effective width at criticle section ( B'f ) = 1400 mm

Effective depth at criticle section ( d' ) = 250 mm

Nominal shear stress ( tv = Vu / B'f d' ) = 0.3 N/mm2

Permissible shear stress in concrete ( tc ) = 0.34 N/mm2 > 0.3

Hence, Footing is Safe in One way Shear.

CHECK FOR TWO WAY SHEAR :

Max. shear force ( VU ) 391.49 KN


p* [ L^2 - (Ped+d)*(Ped+d) ]
Perimeter of the Footing @ criticle section = 2220.00 mm
Bo = [ 2(Bc+ Dc)+4d]

Effective depth at criticle section ( d'' ) = 250.00 mm

Shear Stress (t v) = 0.71 N/mm2


Max allowble punching Shear stress ( t'c ) = 1.12 N/mm2 > 0.71
t'c = 0.25sqrt fck

Hence, Footing is Safe in Punching.


F12 SVPCL

Hence Safe

safe
safe

safe.

12
N/mm2
DESIGN OF FOOTING - F5

Size of Column ( Bc x Dc) = 0.23 x 0.30 m

Grade of Concrete ( fck ) = M 20

Grade of Steel ( fy ) Fe 500

Load coming to the Column ( P ) = 358.6112 KN

Moment About X-Axis (Mx) = -0.4106 KN-m

Moment About Z-Axis (Mz) = -2.5386 KN-m

Horizontal reaction(Fx) = 0.00 KN

Horizontal reaction(FZ) = 0.00 KN

Height of excavation ( h ) = 2.00 m

Moment due to horizontal reaction(Fx*h) = 0.00 KN-m

Moment due to horizontal reaction(Fz*h) 0.00 KN-m

Total Moment Mx -0.41 KN-m

Total Moment Mz -2.54 KN-m

Total load on footing ( W = 1.1P ) = 394.47 KN

Safe bearing capacity of soil ( gsafe ) = 180 KN/m2

Area of Footing required (Areq = W /g safe) = 2.19 m2

Size of Footing Required (Bf x Df) = 1.48 x 1.48 m

Provided size of the footing = 1.5 X 1.5 m

Check for Bearing = 154.14 < 180


(P/A) + (6*Mx/Bf x Df ) + (6*Mz/Bf x Df )
2 2

Hence, the Footing is SAFE in bearing

Area of footing ( A ) = 2.25 m2

Projection beyond the column = 0 m

Size of Pedestal( Bp x Dp ) = 0.23 x 0.30 m

Net upward pressure due to fac. Load ( p ) = 239.07 KN/m2

Moment Mu = p Bf ( Bf - Bc)2/ 8 = 72.3 KN-m

Depth of footing required for B.M ( Dreq ) 132.15 mm


Dreq = SMu / 0.138 fck Bf

Provided depth of footing ( D ) = 300 mm B.M


Assume Cover for Footing (dc) = 50 mm Shear
:
Effective Depth ( d ) = 250 mm Punching
:
Edge depth of footing ( De ) = 300 mm

Mu / Bf d2 = 0.77

% of Steel Pt required from SP: 16 = 0.186

Required Steel (Ast req) = 697.5 mm2

Dia Of Bars Provided ( f ) = 10 mm

Area Of each 10 mm dia bar = 78.54 mm2

No: Of 10 mm dia bars (required) = 9 no.s

Spacing of main bars required ( Sreq ) = 167 mm

Provided @ Spacing ( S ) = 150 mm

Provided % of steel = 0.21

Provided Area of Steel = 785.40

No: Of 10 mm dia bars (provided) = 10.00

Hence Provide 10 tor @ 150 c/c Both ways

CHECK FOR ONE WAY SHEAR :

Shear force at critcle section ( Vu ) = 138.06 KN


Vu = p Bf [0.5 ( Bf - Bc )-d ]

Effective width at criticle section ( B'f ) = 1500 mm

Effective depth at criticle section ( d' ) = 250 mm

Nominal shear stress ( tv = Vu / B'f d' ) = 0.37 N/mm2

Permissible shear stress in concrete ( tc ) = 0.34 N/mm2 < 0.37

UN SAFE

CHECK FOR TWO WAY SHEAR :

Max. shear force ( VU ) 482.83 KN


p* [ L^2 - (Ped+d)*(Ped+d) ]
Perimeter of the Footing @ criticle section = 2060.00 mm
Bo = [ 2(Bc+ Dc)+4d]

Effective depth at criticle section ( d'' ) = 250.00 mm

Shear Stress (t v) = 0.94 N/mm2


Max allowble punching Shear stress ( t'c ) = 1.12 N/mm2 > 0.94
t'c = 0.25sqrt fck

Hence, Footing is Safe in Punching.


F12 SVPCL

2.1904 2.25

5.905512 4.92126

Hence Safe

safe
un safe

safe.

12
N/mm2
DESIGN OF FOOTING - F5

Size of Column ( Bc x Dc) = 0.23 x 0.38 m

Grade of Concrete ( fck ) = M 20

Grade of Steel ( fy ) Fe 500

Load coming to the Column ( P ) = 368.36 KN

Moment About X-Axis (Mx) = -3.58 KN-m

Moment About Z-Axis (Mz) = 3.26 KN-m

Horizontal reaction(Fx) = 0.00 KN

Horizontal reaction(FZ) = 0.00 KN

Height of excavation ( h ) = 1.50 m

Moment due to horizontal reaction(Fx*h) = 0.00 KN-m

Moment due to horizontal reaction(Fz*h) 0.00 KN-m

Total Moment Mx -3.58 KN-m

Total Moment Mz 3.26 KN-m

Total load on footing ( W = 1.1P ) = 405.20 KN

Safe bearing capacity of soil ( gsafe ) = 120 KN/m2

Area of Footing required (Areq = W /g safe) = 3.38 m2

Size of Footing Required (Bf x Df) = 1.84 x 1.84 m

Provided size of the footing = 2 X 1.7 m

Check for Bearing = 91.85 < 120


(P/A) + (6*Mx/Bf x Df ) + (6*Mz/Bf x Df )
2 2

Hence, the Footing is SAFE in bearing

Area of footing ( A ) = 3.4 m2

Projection beyond the column = 0 m

Size of Pedestal( Bp x Dp ) = 0.23 x 0.38 m

Net upward pressure due to fac. Load ( p ) = 162.51 KN/m2

Moment Mu = p Bf ( Bf - Bc)2/ 8 = 127.28 KN-m

Depth of footing required for B.M ( Dreq ) 151.85 mm


Dreq = SMu / 0.138 fck Bf

Provided depth of footing ( D ) = 300 mm B.M


Assume Cover for Footing (dc) = 50 mm Shear
:
Effective Depth ( d ) = 250 mm Punching
:
Edge depth of footing ( De ) = 300 mm

Mu / Bf d2 = 1.02

% of Steel Pt required from SP: 16 = 0.25

Required Steel (Ast req) = 1250 mm2

Dia Of Bars Provided ( f ) = 12 mm

Area Of each 12 mm dia bar = 113.1 mm2

No: Of 12 mm dia bars (required) = 12 no.s

Spacing of main bars required ( Sreq ) = 167 mm

Provided @ Spacing ( S ) = 125 mm

Provided % of steel = 0.36

Provided Area of Steel = 1809.60

No: Of 12 mm dia bars (provided) = 16.00

Hence Provide 12 tor @ 125 c/c Both ways

CHECK FOR ONE WAY SHEAR :

Shear force at critcle section ( Vu ) = 206.39 KN


Vu = p Bf [0.5 ( Bf - Bc )-d ]

Effective width at criticle section ( B'f ) = 2000 mm

Effective depth at criticle section ( d' ) = 250 mm

Nominal shear stress ( tv = Vu / B'f d' ) = 0.41 N/mm2

Permissible shear stress in concrete ( tc ) = 0.42 N/mm2 > 0.41

Hence, Footing is Safe in One way Shear.

CHECK FOR TWO WAY SHEAR :

Max. shear force ( VU ) 612.60 KN


p* [ L^2 - (Ped+d)*(Ped+d) ]
Perimeter of the Footing @ criticle section = 2220.00 mm
Bo = [ 2(Bc+ Dc)+4d]

Effective depth at criticle section ( d'' ) = 250.00 mm

Shear Stress (t v) = 1.10 N/mm2


Max allowble punching Shear stress ( t'c ) = 1.12 N/mm2 > 1.10
t'c = 0.25sqrt fck

Hence, Footing is Safe in Punching.


F12 SVPCL

Hence Safe

safe
safe

safe.

12
N/mm2
Story Joint LabelUnique Name
Load Case/Combo FZ MX
kN kN-m
Base 14 80 Comb1 397.3661 3.7137
Base 11 77 Comb1 370.9854 -1.0168
Base 18 84 Comb1 358.6112 -0.4106
Base 12 78 Comb1 348.3416 0.1221
Base 1 67 Comb1 343.7574 4.0335
Base 5 71 Comb1 340.0842 0.8625
Base 4 70 Comb1 320.1883 -0.3078
Base 3 69 Comb1 319.1926 -0.3497
Base 15 81 Comb1 295.7653 -3.4696
Base 16 82 Comb1 295.6293 0.6211
Base 7 73 Comb1 285.3555 -2.128
Base 17 83 Comb1 280.0136 1.0297
Base 13 79 Comb1 275.8637 2.9209
Base 10 76 Comb1 267.8931 -0.3444
Base 22 86 Comb1 238.2215 -1.6131
Base 19 85 Comb1 234.4364 -0.6607
Base 6 72 Comb1 220.7906 1.0321
Base 2 68 Comb1 193.0395 -0.4064
Base 9 75 Comb1 189.3797 -0.9615
Base 8 74 Comb1 98.0864 -0.0585
MY
kN-m
-2.304 230x230
-0.0533 230x300
-2.5386 230x300
-0.6801 230x300
2.272 230x300
1.4124 230x380
1.7264 230x230
2.0175 230x300
0.0535 230x230
-1.974 230x230
-0.4901 230x300
-1.7867 230x230
-0.8092 230x300
-0.3978 230x300
-1.7582 230x380
-2.1194 230x230
1.1836 230x230
1.9977 230x230
-0.623 230x230
-0.9795 230x230

Das könnte Ihnen auch gefallen