Sie sind auf Seite 1von 17

Integrated Air Management System

Design it your way, every time, every way.....

Tec
h n
with ologi
a n e es
edgetech is all about developing innovative, intelligent products dge
Dimensional Flexibility
that bridge the gap between imagination and reality
Space constraints are a reality on most
to make your life easy.
construction projects. Why be constrained by
fixed AHU sizes? edgetech offer variable

Applications aspect-ratio, so you can design the unit to fit Material Flexibility
gies the application & space. And if rectangular-
olo ge — Commercial Space : Office Buildings, edge tech offer a complete range of
e ch n a n ed shaped units can not fit the space, units can be
T with Theaters, Auditoriums construction materials, including galvanized
configured to fit within just about any existing
— Institutional Space : Schools, Universities, steel, pre-painted, painted, SS, aluminium,
Libraries, Temples. space or around any obstacle. 'L' and 'T' shaped
etc.
units, stacked units, notched units - you name
— Industrial Manufacturing : Automotive,
Air Management Systems Chemical, Petrochemical, Aerospace it, we can do it for you.
Component Flexibility
— Hygienic Systems : Hospitals, Life Science
edgetech, the name you need to know for
Centers, R & D Facilities, Food Processing, To enable you to meet any AIR HANDLING
"Air Management Systems", that has no limits Clean rooms requirement, edgetech units offer every
ranging from basic units to specialized
— Process Manufacturing : Pharmaceutical, available air handling component. And as the
applications. Electronics, Semiconductor technology creates new components,
Whatever the air-handling challenge - clean — IT Industry edgetech shall ensure these to be offered to
room, indoor air quality, energy, acoustics, you in our state of the art Units.
controls, dimensional flexibility - you name it -
edgetech has the expertise to deliver a
perfect solution.

2 3
Choose...the way you want
The Panel
The Frame
Standard 25 mm or 43 mm double
edgetech unique frame designed has inherent strength & skinned construction infilled with
stability. The modular framework is constructed of corrosion pressure injected CFC & HFC free PUF
resistant extruded aluminium hollow profile. One can choose with 'k' value of 0.02 Watts/ m°C and
from a wide variety of profiles ranging from basic profiles to density of 38-40 kg/m3. Combination
specialized true thermal break profiles with covings. choice of precoated, prepainted, pre-
plasticised, plain galvanised sheets,
aluminium, SS 304 & SS 316 in various
thicknesses is available for inner & outer
skin of the panel. Choice of glass wool,
mineral wool, phenolic insulation is also
The panels are fixed to the frame work using
available.
special imported self drilling & tapping screws.
To ensure air tight construction, self sticking
adhesive coated special gaskets are provided
between the panel & frame. For specialized
applications food grade gaskets are provided.

The Base Frame The Accessability


The entire module is mounted on a The various sections of the modules
continuous beam of heavy galvanised like, filter, coil, air washer, fan, mixing
steel channel or sectional aluminium chamber, etc. requiring regular
alloy held together with die cast maintenance & inspection, have hinged
aluminium joints with heavy lifting or fully removable access panels. The
holes for easy handling. access panel is fitted to the frame with
easy release nylon handle and cam locks.
The handle can be operated internally
for additional safety. Hinges are of heavy
duty load bearing design. The other
panels can be detached using simple
hand tools.

4 5
The Performance...You Ever Expected

The Fan & Motor Module The Coil Section


edgetech offers high energy efficient forward
edgetech offers coils that are selected
curved or backward curved, aerofoil, AMCA
to obtain optimum psychometric
certified centrifugal fans. All fans are
efficiency with low air & water pressure
individually tested & precision balanced,
drops. A wide range of chilled water,
statically & dynamically. Fan & motor are
direct expansion, hot water & steam
mounted on extruded aluminium slide rails
coils are available to choose from. A
with provision for easy belt tensioning. The
combination of multiple row deep with
entire fan & motor arrangement is mounted on
options of aluminium fins, anticorrosive
combination spring & rubber vibration
aluminium fins & copper fins are available. Flexibility with respect to side plates in galvanized steel
isolators that are selected to match the power 2
sheet or SS, are also an added edged feature. Each coil is pressure tested at 21 kg/cm under water.
w i t h
The coil assembly is completed with carbon steel or copper header which is located within the coil
ratio
section on slide type arrangement for easy withdrawl & maintenance. AHUs with stack coils have
f o r
intermediate drain pan to collect the condensate of the top coil & drain the condensate through
maximum isolation. The fan is connected to main casing
PVC drop tubes to the main drain pan without flooding the lower coil.
using self extinguishing & moisture resistant fabric
flexible connection ensuring low operating noise &
vibration.
Direct drive plenum fan is also available for specialised
applications.

The Drain Pan

M i c r o
organisms can flourish in drain
pans when cooling coil condensate
remains there during off or heating cycles.
Edgetech unique hygienic drain-pan designed
with multi slope ensures positive drainage of the
condensate. The drain pan can be accessed easily
for a periodic cleaning. Flexibility of
construction material in SS 304 , Aluminium or
GSS to choose from. The drain pan is insulated for
thermal protection with 10 mm thick closed
cell elastomeric insulation.

6 7
The Choice is Yours...
The Accessories & Options
* Lamp switch as option
The Filter Section
* Variable frequency drive with bypass
Fully sealed filter sections are arrangement
designed for easy withdrawal * Contoured aluminium roof for outdoor
Inspection window as option
and renewal of filter cells and application.
are constructed to house any * Intake louvre with bird screen for fresh air
type of primary or secondary intake.
filters of different media with
* Outlet cowl with bird screen for exhaust unit.
variable efficiencies. In areas of
* Fire retardent flexible joints for Inlet & outlet
particular importance, such as
of the unit.
hospitals and clean rooms, Buckhead lamp as standard
* Sound attenuation section for low noise
absolute filters can be provided
applications.
to ensure safe human and
* Humidification section with wet deck 100 mm or
machine environments.
200 mm / spray type with inlet vanes & mist
eliminator / steam humidifier & pan type
humidif ier for critical applications.
* Face & bypass / bypass damper section.
Limit switch as standard
* Drift eliminators in PVC / SS / Aluminium / G.I.
* Condensate drain pump for underground
The Air Mixing Section installations.
* Electric heater section for heating / humidity
Return air & fresh air can be mixed at the required rate with
control.
dampers that are specifically designed to minimise the
stratification of entering air streams for maximum air * Cross flow plate type, wheel type heat recovery
efficiency. Manual/Motorized Damper in extruded aluminium and heat pipe can be supplied as an integral part
aerofoil design, GSS construction or SS construction are of the unit for energy conservation.
available to choose from. A choice of 2 way or 3 way mixing Micro processor control panel with required
chamber is also available.
The Safety field sensors duly wired to the unit.

* Provision for electrically interlocked fan


section with access door
* Wire guard for fan section
* Earthing of fan & motor

8 9
The Product Range

Air Handling Unit


Horizontal Floor Mounted Units
(Capacity Range 1000 CFM - 40000 CFM)
- Double Skin
- Single Skin
Unitary / Vertical Units
(Capacity 1000 CFM - 12000 CFM)

Ceiling Suspended Ductable Units


(Capacity 1000 CFM - 10000 CFM)

Direct Drive Ceiling Suspended Ductable Units


(Capacity 1000 CFM - 5000 CFM)

Ventilation Units - Fresh Air / Exhaust


(Capacity 1000 CFM- 40000 CFM)
Unlimited
Ventilation Units - Pharmaceuticals Applications Range of Air Handling Units
(Capacity 1000-40000 CFM)
For Any Application
Fan Coil Units
(Capacity 1.0 TR - 3.0 TR)
- Horizontal Ceiling Concealed
- Vertical Floor Mounted

Evaporative Cooling Unit/ Air Washer


(Capacity 1000-40000 CFM)

Heat Recovery Units


(Capacity 1000-40000 CFM)

10 11 12
Quick Air Handling Unit Selection Chart (Horizontal Floor Mounted)
Air Filter Air Volume (CFM)
Model Dimensions (MM) Coil Face
Volume Face Area At different Air Velocity Through Unit Components
ETU Area (Sq.Ft)
(CFM) (Sq.Ft)
Lenght Width Total Height 2.25 MPS 2.5 MPS 2.75 MPS
012H 1200 1320 850 850 4.0 2.4 1080 1200 1320
015H 1500 1320 850 850 4.0 3.0 1350 1500 1650
020H 2000 1370 850 850 4.0 4.0 1800 2000 2200
025H 2500 1450 1100 900 6.0 5.0 2250 2500 2750
030H 3000 1550 1180 950 6.0 6.0 2700 3000 3300
040H 4000 1550 1470 950 8.0 8.0 3600 4000 4400
050H 5000 1700 1350 1200 12.0 10.0 4500 5000 5500
060H 6000 1850 1550 1200 12.0 12.0 5400 6000 6600
080H 8000 1950 1550 1520 16.0 16.0 7200 8000 8800
100H 10000 2100 1850 1520 20.0 20.0 9000 10000 11000
120H 12000 2225 2150 1520 24.0 24.0 10800 12000 13200
150H 15000 2580 2180 1850 30.0 30.0 13500 15000 16500
180H 18000 2790 2550 1850 40.0 36.0 16200 18000 19800
200H 20000 2790 2750 1850 40.0 40.0 18000 20000 22000
230H 23000 2790 2750 2150 48.0 46.0 20700 23000 25300
260H 26000 2925 2900 2250 54.0 52.0 23400 26000 28600
300H 30000 2925 3100 2450 63.0 60.0 27000 30000 33000
350H 35000 3085 3250 2650 70.0 70.0 31500 35000 38500
400H 40000 3185 3250 3230 80.0 80.0 36000 40000 44000

Please refer Horizontal Floor Mounted Unit-Dimension Chart for further information on dimensions.
Above mentioned length includes 50 mm thick pre filter, 4/6 rows deep coil and fan.

Quick Fan Selection Chart


KAT Series
Fan Opening (MM) Fan Outlet Area Air Volume (CFM) At Different Fan Outlet Velocity
Fan Model (Sq.M)
D E AT 8 MPS AT 9 MPS AT 10 MPS AT 11 MPS
7x7 228 259 0.0591 1001 1126 1251 1376
9x9 262 298 0.0781 1323 1489 1654 1820
10x10 289 331 0.0957 1622 1824 2027 2230
12x12 341 395 0.1347 2283 2569 2854 3139
15x15 404 471 0.1903 3226 3629 4032 4435
18x18 478 557 0.2662 4513 5077 5641 6206

Forward / Backward / Airfoil Blade Series

Model Fan Opening (MM) Fan Outlet Area Air Volume (CFM) At Different Fan Outlet Velocity
ETU D E (Sq.M) At 8 MPS At 9 MPS At 10 MPS At 11 MPS
#160 204 204 0.0416 705 794 882 970
180 228 228 0.0520 881 991 1101 1212
200 256 256 0.0655 1111 1250 1389 1527
225 288 288 0.0829 1406 1582 1757 1933
250 322 322 0.1037 1758 1977 2197 2417
280 360 360 0.1296 2197 2471 2746 3021
315 404 404 0.1632 2767 3113 3458 3804
355 452 452 0.2043 3463 3896 4329 4762
400 506 506 0.2560 4340 4883 5425 5968
450 568 568 0.3226 5469 6152 6836 7520
500 638 638 0.4070 6900 7762 8625 9487
560 714 714 0.5098 8642 9722 10802 11882
630 800 800 0.6400 10849 12205 13561 14917
710 898 898 0.8064 13669 15368 17087 18795
800 1006 1006 1.0120 17155 19299 21444 23558
900 1130 1130 1.2769 21645 24350 27056 29762
1000 1266 1266 1.6028 27168 30564 33960 37356
Please refer Horizontal Floor Mounted Unit-Dimension Chart to locate D & E
#Backward & Airfoil Models Not Available

13
Horizontal Floor Mounted Unit-Dimension Chart
W S1 S1 S1
E
FILTER SIZES
A=610 X 610
S3 B=610 X 305

S1
S2
C=305 X 305
H

(all dimension
in mm)

External Combination
Dimensions Filter Section Chilled Hot Water Hot Water
Overall Length (MM) Chilled Discharge
(MM) Pre (50 mm Water Electric Discharge
(50 mm thick Ducted Intake Mixing Section Double Mixing Plain Filter Water Coil
Coil Section
Coil Section Coil Section Plenum With Filter Quantity
Fan Section thick) & Bag Section 1-6 1-2 4-6 Heater Plenum with A/B/C
Prefilter, 1 -6 RD Section With Flat Filter Section Section Model 8 Fine Filter &
(360 mm Rows Deep Rows Deep Rows Deep Section Fine Filter
Model Coil And Fan) ETU Rows Deep HEPA Filter
Total thick) or Fine
ETU- Width (305 mm thick)
Height
(W)
(H)
Section Wise Details Of Add On Modules Section Wise Details Of Add On Modules

012H 850 850 1320 870 440 450 880 200 012H 450 450 550 200 300 450 1000 1800 1/0/0

015H 850 850 1320 870 440 450 880 200 015H 450 450 550 200 300 450 1000 1800 1/0/0

020H 850 850 1370 920 440 450 880 200 020H 450 450 550 200 300 450 1000 1800 1/0/0

025H 1100 900 1450 1000 480 560 1000 200 025H 450 450 550 200 300 450 1450 2400 1/1/0

030H 1180 950 1550 1100 480 560 1000 200 030H 450 450 550 200 300 450 1450 2400 1/1/0

040H 1470 950 1550 1100 480 560 1000 200 040H 450 450 550 200 300 450 1450 2400 2/0/0

050H 1350 1200 1700 1250 480 560 1000 200 050H 450 450 550 200 300 450 1450 2400 2/2/0

060H 1550 1200 1850 1400 560 680 1200 200 060H 450 450 550 200 300 450 1450 2400 2/2/0

080H 1550 1520 1950 1500 560 680 1200 200 080H 450 450 550 200 300 450 1550 2600 4/0/0

100H 1850 1520 2100 1600 640 780 1380 200 100H 450 500 600 200 300 450 1550 2600 4/2/0

120H 2150 1520 2225 1725 640 780 1380 200 120H 450 500 600 200 300 450 1550 2600 6/0/0

150H 2180 1850 2580 2000 640 880 1580 200 150H 450 550 650 200 300 450 1550 2600 6/3/0

180H 2550 1850 2790 2240 640 1040 1840 200 180H 450 550 650 200 300 450 1750 2800 8/4/0

200H 2750 1850 2790 2240 840 1040 1840 200 200H 450 550 650 200 300 450 1750 2800 8/4/0

230H 2750 2150 2790 2240 840 1040 1840 200 230H 450 550 650 200 300 450 1750 2800 12 / 0 / 0

260H 2900 2250 2925 2375 840 1040 1840 200 260H 450 550 650 200 300 450 1750 2800 12 / 3 / 0

300H 3100 2450 2925 2375 840 1320 2400 200 300H 450 550 650 200 300 450 1750 2800 12 / 7 / 1

350H 3250 2650 3085 2535 840 1320 2400 200 350H 450 550 650 200 300 450 1750 2800 15 / 5 / 0

400H 3250 3250 3185 2635 840 1320 2400 200 400H 450 550 650 200 300 450 1750 2800 20 / 0 / 0

Note :
Standard models with 25 mm thick pannels are mentioned above, for 43 mm thick pannels add 45 mm extra to the width(W) and height(H) of the unit.
Total height (H) includes 100 mm deep base channel.

 Symbol in the various sections above shows access door. If the same is required after HEPA filter for DOP test add 300 mm extra to the section.
For two tier AHUs and for other add on modules viz., wet deck section, spray section (single bank or double bank), heat recovery plate section or heat recovery
wheel section, sound attenuator section, empty section etc please contact our technical assistance department.

14 15
Standard Vertical / Unitary Units

V-Series
Overall Dimension (MM)
Model Air Fan Model (25 mm thick Prefilter, 1 - 6 RD Fan Outlet RPM / BKW / Recommended Motor kw
ETU Volume KAT/FDA Coil & Fan) Velocity at a Static Pressure of
(CFM) Series Total (m/s)
Depth Width Height 32 MM WG 40 MM WG 50 MM WG

012V 1200 KAT 7/7/C 625 900 1140 9.59 1766/0.50/0.75 1865/0.54/0.75 2031/0.62/0.75

015V 1500 KAT 9/9/C 625 1080 1190 9.07 1173/0.46/0.55 1312/0.55/0.75 1585/0.81/1.1

020V 2000 KAT 10/10/C 680 1030 1370 9.87 1027/0.57/0.75 1138/0.69/1.1 1286/0.83/1.1

025V 2500 KAT 12/12/C 750 1215 1440 8.76 894/0.70/1.1 1040/0.92/1.1 1205/1.21/1.5

030V 3000 KAT 9/9/S2 625 1555 1245 9.07 1220/0.99/1.1 1365/1.19/1.5 1649/1.73/2.2

040V 4000 KAT 10/10/S2 680 1765 1350 9.87 1068/1.22/1.5 1184/1.49/2.2 1337/1.79/2.2

050V 5000 KAT 12/12/S2 750 1950 1480 8.76 930/1.51/2.2 1082/1.97/2.2 1253/2.6/3.7

060V1 6000 KAT 12/12/S2 750 2050 1565 10.52 927/1.91/2.2 1030/2.28/3.7 1176/2.85/3.7

060V2 6000 KAT 18/18/C 975 1775 1935 10.64 646/1.64/2.2 716/1.96/2.2 806/2.44/3.7

070V 7000 KAT 15/15/S2 840 2150 1810 8.68 801/2.01/2.2 902/2.49/3.7 1026/3.19/3.7

080V 8000 KAT 15/15/S2 860 2200 1845 9.93 801/2.36/3.7 896/2.88/3.7 1006/3.55/5.5

100V 10000 KAT 18/18/S2 1000 2550 1965 8.87 666/2.79/3.7 770/3.60/5.5 900/4.95/5.5

120V 12000 KAT 18/18/S2 1000 2800 2030 10.64 672/3.53/5.5 744/4.22/5.5 900/4.95/5.5

140V 14000 FDA 450/2 NOS. 1100 2600 2500 10.24 630/1.97/2.2 700/2.35/3.7 785/2.89/5.5

160V 16000 FDA 500/2 NOS. 1250 3000 2600 9.28 595/2.21/3.7 661/2.66/3.7 740/3.29/5.5

180V 18000 FDA 500/2 NOS. 1250 3000 2700 10.44 602/2.61/3.7 666/3.11/5.5 739/3.75/5.5

# Above indicated data (RPM / BKW / Motor KW) corresponds to mean sea level.
# For Selection at other static pressure please contact our technical assistance department
Note :
Standard models with 25 mm thick panels are mentioned above.
For 8 rows deep coil add 100 mm extra to the depth of the unit.
Total height includes 100 mm deep base channel.
Units having fan model as S2 shall have two impellers mounted on common shaft driven by single motor.
For other add on modules viz., mixing chamber, ducted intake section, filter plenum, hot water coil section, electric heater section, pre & bag filter on
common frame, sound attenuator section, empty section etc please contact our technical assistance department.

16
Standard Ceiling Suspended Ductable Units

C-Series
Overall Dimension (MM)
Model Air Fan Model (25 mm thick Prefilter, 1 - 6 RD Fan Outlet RPM / BKW / Recommended Motor kw
ETU Volume KAT/FDA Coil & Fan) Velocity at a Static Pressure of
(CFM) Series (m/s)
Depth Width Height 32 MM WG 40 MM WG 50 MM WG

012C 1200 KAT 7/7/C 1180 800 540 9.59 1766/0.50/0.75 1865/0.54/0.75 2031/0.62/0.75

015C 1500 KAT 9/9/C 1180 930 550 9.07 1173/0.46/0.55 1312/0.55/0.75 1585/0.81/1.1

020C 2000 KAT 10/10/C 1230 1030 610 9.87 1027/0.57/0.75 1138/0.69/1.1 1286/0.83/1.1

025C 2500 KAT 12/12/C 1300 1150 670 8.76 894/0.70/1.1 1040/0.92/1.1 1205/1.21/1.5

030C 3000 KAT 9/9/S2 950 1550 550 9.07 1220/0.99/1.1 1365/1.19/1.5 1649/1.73/2.2

035C 3500 KAT 10/10/S2 1230 1580 610 8.64 1059/1.03/1.5 1201/1.27/1.5 1382/1.70/2.2

040C 4000 KAT 10/10/S2 1000 1765 610 9.87 1068/1.22/1.5 1184/1.49/2.2 1337/1.79/2.2

050C 5000 KAT 12/12/S2 1050 1925 670 8.76 930/1.51/2.2 1082/1.97/2.2 1253/2.6/3.7

060C 6000 KAT 12/12/S2 1050 2150 750 10.52 927/1.91/2.2 1030/2.28/3.7 1176/2.85/3.7

070C 7000 KAT 15/15/S2 1050 2160 800 8.68 801/2.01/2.2 902/2.49/3.7 1026/3.19/3.7

080C 8000 KAT 15/15/S2 1250 2250 900 9.93 801/2.36/3.7 896/2.88/5.5 1006/3.55/5.5

100C 10000 KAT 18/18/S2 1300 2550 980 8.87 666/2.79/3.7 770/3.60/5.5 900/4.95/5.5

120C 12000 KAT 18/18/S2 1300 3000 980 10.64 679/3.51/5.5 753/4.21/5.5 851/5.26/7.5

# Above indicated data (RPM / BKW / Motor KW) corresponds to mean sea level.
# For selection at other static pressure please contact our technical assistance department.

Note :
Standard models with 25 mm thick panels are mentioned above.
For 8 rows deep coil add 100 mm extra to the depth of the unit.
Units having fan model as S2 shall have two impellers mounted on common shaft driven by single motor.
For other add on modules viz., mixing chamber, ducted intake section, filter plenum, hot water coil section, electric heater section, pre & bag filter
on common frame, sound attenuator section, empty section etc please contact our technical assistance department.

17
Standard Ceiling Suspended Ductable Units
(Direct Drive Fans)

Unit Model ETU-012CD ETU-015CD ETU-020CD ETU-030CD ETU-040CD ETU-050CD

Air Qty. (CFM) 1200 1500 2000 3000 4000 5000

Static Pressure 25-30 mm wg

Pannel Thickness 25 mm

Coil Face Area (Sq. Ft.) 2.4 3 4 6 8 10

Row Deep 4/6

Fan Type / Drive DIDW Centrifugal Forward Curved Direct Drive

Fan Model 9/9 9/9 10/10 9/9 10/10 12/12

No. of Fans 1 1 1 2 2 2

Watt 375 375 550 375x2 550x2 709x2

Motor Pole 6 6 4 6 4 6

RPM 950/925/900 950/925/900 1300/1200/1150 950/925/900 1300/1250/1150 900/715/510

Volt 220-240

Filter Type / Thickness Pre-Filter / 25 mm

Filter Media Non Woven Synthetic

Overall Dimension (mm)

Depth 960 960 960 960 960 1000

Width 1110 1110 1200 1650 1980 1925

Height 520 520 560 560 560 670

Note :
Above technical details refer to a static pressure of 25 - 28 mm WG.
Standard models with 25 mm thick panels are mentioned above.
For more details please contact our technical assistance department.

18
Standard Horizontal Floor Mounted Ventilation Units

Overall Dimension (MM)


Air
Model Fan Model Filter Area Filter Quantity (50 mm thick Prefilter & Fan)
Volume
ETU- KAT/FDA Series (Sq.Ft) A/B/C
(CFM)
Lenght Width Total Height

012VU 1200 KAT 7/7/C 2.0 0/1/0 900 620 720

015VU 1500 KAT 9/9/C 4.0 1/0/0 900 720 820

020VU 2000 KAT 10/10/C 4.0 1/0/0 1000 900 850

025VU 2500 KAT 12/12/C 4.0 1/0/0 1000 1000 850

030VU 3000 KAT 15/15/C 6.0 1/1/0 1200 1100 925

040VU 4000 KAT 15/15/C 6.0 1/1/0 1240 1100 925

060VU 6000 FDA 450 8.0 2/0/0 1350 1290 1200

080VU 8000 FDA 500 12.0 2/2/0 1500 1400 1300

100VU 10000 FDA 560 16.0 4/0/0 1560 1400 1500

120VU 12000 FDA 630 16.0 4/0/0 1700 1560 1600

160VU 16000 FDA 710 20.0 4/2/0 2000 1750 1800

200VU 20000 FDA 800 30.0 6/3/0 2140 2000 1950

250VU 25000 FDA 900 36.0 9/0/0 2300 2100 2200

300VU 30000 FDA 900 42.0 9/3/0 2300 2400 2200

350VU 35000 FDA 1000 48.0 12 / 0 / 0 2500 2700 2200

400VU 40000 FDA 1000 56.0 12 / 4 / 0 2500 2700 2500

Note :
Filter dimensions: A = 610 x 610; B = 610 x 305 & C = 305 x 305 (all in mm)
Total height includes 100 mm deep base channel
Optional accessories: bird screen, dampers, inlet cowl, louvers, ducted intake section, empty section, pre & fine filter on common frame, fine
filter plenum etc.

19
Single Skin

D u c ta b l e U n i t s
Low Height, Ceiling Suspended Ductable Units (Direct Drive Fans)
offers compact solutions for compact spaces. The standard single skin unit is available in 6 model with an
airflow range of 1200 - 5000 CFM.

Salient Features
n Low height & compact design saves valuable space : ceiling suspended units are of low height, so they occupy
less space above the false ceiling, thereby, providing more shelf space.

n Quiet operations : The units are fitted with low noise, DIDW forward curved centrifugal fans ideally suited for
offices, shops, restaurants, hotels, nursing homes, etc.

n Variable speed saves energy : The units are fitted with 3 speed drive. One can adjust fan speed as per cooling load
conditions, thereby, saving energy & enhancing personal comfort.

n Closed cell XPE thermal lining prevent sweating ensuring the safety of false ceiling.

n Computer selected, high efficiency, cooling coils ensures effective heat transfer for years.

n Powder coated GI construction virtually make the unit highly durable and rugged.

Technical Data
Unit Model ETU-012SD ETU-015SD ETU-020SD ETU-030SD ETU-040SD ETU-050SD
Air Qty. CFM 1200 1500 2000 3000 4000 5000

Static Pressure 20-30 mm wg

Casing Thickness 20 G GSS


Type of External Finish Powder Coated

Internal Insulation 6 mm closed cell XPE


Coil Face Area (Sq. Ft.) 2.4 3 4 6 8 10
Rows Deep 4/6
Fan Type / Drive DIDW Centrifugal Forward Curved Direct Drive

Fan Diameter 9/9 9/9 10/10 9/9 10/10 12/12

No. of Fans 1 1 1 2 2 2

Watt 375 375 550 375x2 550x2 709x2

Pole 6 6 4 6 4 6

RPM 950/925/900 950/925/900 1300/1200/1150 950/925/900 1300/1250/1150 900/715/510

Volt 220 - 240


Filter Type / Thickness Per - Filter 12 thick

Filter Media HDPE Mesh

Overall Dimension of Units


Depth 695 695 750 695 750 850

Width 950 950 1050 1550 1775 1925


Height 460 460 520 460 520 575
STANDARD HORIZONTAL CEILING SUSPENDED

FAN COIL UNITS


BLOWER HOUSING
H

MOUNTING 25mm collar


HOLES 4 NOS

DRAIN SOCKET DUCT CONNECTION

I
G

MOTOR

D
F

COIL TRAY

5
8"FLAIR NUT AIR FILTER

AIR OUT

C
COOLING COIL

A B

Model TR Air Motor Rows Coil Dimensional Detail (MM)


ETU- Volume Rating Deep Area
(CFM) (HP) (Sq. Ft) A B C D E F G H I J

12OFCH 1.0 400 1/15 3 1.33 915 576 256 282 660 233 250 698 142 609
180FCH 1.5 600 1/15 3 1.77 1118 576 256 282 863 233 250 902 142 812
3 2.43 1193 598 305 282 939 245 250 978 192 889
240FCH 2.0 800 1/12
4 1.90 1005 598 305 282 749 245 250 789 192 698
3 3.00 1219 598 356 282 965 245 250 1003 242 914
300FCH 2.5 1000 1/12
4 2.25 1130 598 305 282 876 245 250 916 192 825
3 3.50 1371 653 356 282 1117 270 250 1155 242 1066
360FCH 3.0 1200 1/3
4 2.66 1118 653 356 282 865 270 250 902 242 812

Note :
Standard horizontal ceiling suspended FCU with 3 (or 4) rows deep coil having 10 mm outside dia. 27 G copper tubes. 12 mm thick rough filters.
13 (or 15)mm thick insulated drain pan and 12 FPI aluminium fins is given above.
Statically and dynamically balanced forward curved aluminium blowers with 3 speed fan motor (make: G.E / Eq.) 6 pole single phase 940 RPM.
For vertical floor mounted FCU and other add on modules viz., heating coil, auxillary tray, factory fitted ball valve set, two way or three way
valves, remote control etc., please contact our technical assistance department.
Edgetech Air Systems Pvt. Ltd.
51/14, Swarn Park, Udyog Nagar, Mundka, Delhi - 110 041 Tel. : +91-11-28344270-72 Fax : +91-11-28344935
Email : sales@edgetech-air.com Website : www.edgetech-air.com

Das könnte Ihnen auch gefallen