Sie sind auf Seite 1von 1

WELD LENGTH OF LAP JOINT

1 Safe Pull Out Test on Pile 45 T


2 Factor of Safety for Test 3
3 Test Load 135 T
4 Factored Load 168.75 T

5 Total number of steel rods 6 Nos.


6 Diameter of each rod 32 mm
7 Load carried by each steel rod P 28.13 T
8 Thickness of weld a 1 cm
9 Shear Strength of weld fw 1100.00 kg/cm2

10 Calculation of weld length Lw = P / (0.8 x fw x 0.707 a )


45.21 cm

11 Total Lap Length required 50 x d 1600 mm

12 Provide lap joint 20 cm 4 Nos. 80 cm


on each side of steel rod

13 Total Weld length 80 cm x 2 sides 160 cm

14 Welding shall be done on each side of reinforcement