Sie sind auf Seite 1von 12

Ducati2 trouble shooting guide

一. Block Diagram overview.


The production blocks diagram show as below. You also can find all

chipset and function connector from the diagrammatic sketch.


二. Production function introduction.
1. WIFI and BT
2. GPS

3. Camera(Front=200M,Rear=500M)

4. Micro SD Card

5. Audio(DMIC + Speaker + Phone Jack)


6. Touch panel

7. LCD

8. Sensor

9. HDMI
HDMI V1.4, 720p 50/60, 1080p 24Hz, 2-chanel PCM, D-type

10. OTG
三. Trouble shooting
1. Cannot connect computer, USB device cannot be detected.

If you install USB cable and connect with the computer, but the

Device cannot be detected. You can debug it by below way.

A: Make sure the DUT has power on. All the voltage is at its level.

B: Measure the SPI ROM voltage, make sure +V1P8A is on, if the

SPI Rom signal is abnormal, +V5P0S voltage level is 0V, +V_VCC is

Always 0.7V,the SVID is not working.

C: Measure the signal USB_ULPI_REFCLK, if this clock is OK, it

may confirm that the SOC and EMMC device is normal. If it still can

not detect the USB device, measure below signal if Necessary

(show as below Schematic).Check all the resistance, measure this

USB_ULPI_RST# signal if it is asserted.


D: Measure the signal from U2202; eliminate the open or short

problem. One way to check +VUSB_CONN voltage, you can

install one OTG line, and then measure this voltage level.
E: If the signal USB_ULPI_REFCLK is ok, U2201 and U2202 have

not any open or short problem, consider replacing these

chipset.

2. Camera no function. Cannot open or detect camera.

A: Measure camera voltage +V2P8_CAM.If this voltage is

abnormal, measure SOC_+V2P8_CAM_EN,if all the signal is

normal, no open or short issue, consider replacing U1901.

B: If camera voltage is ok. Measure the signal from camera

connector to SOC.

C: Check OS software, Download the OS image if Necessary.

3. WIFI or BT no function.

A: Make sure +VBATA_WIFI, VDD_WL_PA, +V1P8S_WIFI, VIN_LDO

voltage is at the level.


B: Make sure all the signal have connected to the SOC, no open

or short issue. Check the RF line and connector if it is normal.


C: Check the EN signal to ensure the SOC have initial the

chipset. If the power and EN signal is normal. Measure the

impedance of the SDIO signal and the pad of chipset.

4. Shutdown when power up.


Power up the DUT. Press switch key more than 6sec.Measure

the power rails after power on. If it power up but shutdown

soon, check the thermal for PMIC and SOC. In general, if the

PMIC thermal is high and heat you hand, should check and

measure the impedance for all the power rails. It should be

cause of one or more power rails burning or shorting. The PMIC

is not easy being burned. But if the LCD is bad, it may cause the
PMIC burning. At present not found anyone PMIC chipset

burning issue. In addition, it the hardware has not trouble

found and the chipset thermal is normal, check the IAFW

directly, Flash IAFW again is helpfully. Anyway, all the power

rails should be at its level after power on.

5. TF card no detected.
When the DUT is working normal under OS. Push TF card

directly, OS should show the card icon, the TF card can be

detected and used. If push TF into the connector but no any

response, measure +VSD power whether it is 3.3V or not.

Measure the detect pin(pin10 of connector CARD1401) after

install TF card. It should be low power level. Also, check the

route from SOC to TF connector.

6. GPS no function
A: measure the GPS power rails. Insure GPS_POWERON signal

is high. If it cannot open the GPS function, it should be the

power issue.

B: Check the component around the GPS chipset.


C: Check the route from SOC to GPS chipset.

D: If GPS function can be open, but cannot search the start or

signal is weakly, check the RF connector or related circuit.

If all hardware is normal, but GPS function still abnormal,

replace the chipset.

7. Battery cannot charge.


Connect USB cable to computer USB point or adapter, low

battery indicator should be charged. If the charge is abnormal,

analysis the circuit as below.

A: If the fuel gauge can show quantity of electricity of the

battery, check the circuit of PU3301.Measure the I2C_0_SCL

and I2C_0_SDA signal which near PU3301,it should be high

after connect battery. Check GPIO_SUS2 signal and related

circuit.

B: If the fuel gauge cannot show quantity of electricity of the

battery, check the circuit of PU3401.


Summary:
Any abnormal from the DUT, we should check the power rails

of them first. Insure all power rails at their level. Check the component

from the DUT, loss, cold solder or bad component may cause the

abnormal. Single function fault could check module circuit for issue

analysis.