Sie sind auf Seite 1von 2

Special Running 106-23

MAN B&W Diesel Data

SAFETY PRECAUTIONS For detailed sketch, see 900-2


X Stopped engine
Shut off starting air supply – At starting air receiver
Block the main starting valve
Shut off starting air distributor/distributing system supply
Shut off safety air supply – Not ME engines
Shut off control air supply
Shut off air supply to exhaust valve – Only with stopped lubriating oil pumps
Engage turning gear
Shut off cooling water
Shut off fuel oil
Stop lubricating oil supply
Lock the turbocharger rotors
X Shut down hydraulic power supply

Data

Ref. Description Value Unit

D06-201 Accumulator 24/55 kg


D06-202 N2 Charging pressure 95 bar at
20°
Pressure Adjustment Table
Accumulator temperature t °C
0 89 bar
10 92 bar
20 95 bar
30 98 bar
40 101 bar
50 105 bar
60 108 bar
70 111 bar
80 114 bar
90 118 bar
100 121 bar
D06-216 assembly off-set 4-liter accumulator 9 mm
D06-217 assembly off-set 10-liter accumulator 10 mm
D06-226 Screw, flange to Accumulator 100 Nm
D06-227 Screw, flange to Hydraulic Cylinder Unit 150 Nm

When referring to this page, please quote Data D10623 Edition 0006 Page 1 (2)
106-23 Special Running
Data MAN B&W Diesel

The task-specific tools used in this procedure are shown on the plates at the end of this chapter or in the
chapters indicated by the first three digits in the plate number, e.g. P90951 refers to chapter 909.

Plate Item No. Description

P90653 P90653 Tools for Accumulator


P90674 P90674 Test Equipment for Accumulators
P91356 P91356 Lifting Tools, Etc.
P91359 P91359 Torque Spanners
P91366 P91366 Instruments

Page 2 (2) When referring to this page, please quote Data D10623 Edition 0006

Das könnte Ihnen auch gefallen