Sie sind auf Seite 1von 4

TM

Microtek LightLid 35
Installing and Getting Started

The LightLid 35 is a bonus accessory


included with your Microtek scanner. It gives
you the versatility to scan 35mm slides and
filmstrips on your flatbed scanner.
Microtek recommends the use of this
accessory to scan slides for on-screen display
purposes or where high resolution is not
critical. For high-quality print reproduction,
we recommend purchasing a dedicated slide
scanner or a Microtek scanner with built-in
film-scanning features.

Please note: Scanning of color transparencies may vary, depending on the quality of
your film original.

A. Installing the LightLid 35

1. Unpack the LightLid 35.


2. Remove the scanner lid.
3. Connect the LightLid 35 to your scanner. To do this:
Connect the 15-pin connector (A in diagram) of your
LightLid 35 to the accessory port (B) at the back panel
of your scanner.

B
A

B. Operating the LightLid 35

1. Mount the 35mm slide or filmstrip on the LightLid 35.


A. Mounting a slide:
Turn the LightLid 35 over. Insert the
35mm slide front side up into the Insert slide front side up
recessed area at the center of the
LightLid. Secure the slide by gripping it
with the grip prong provided at the
connector side of the recessed area. For
added stability, you may wish to secure
the slide with a piece of adhesive tape.
Grip prong for securing slide

Copyright©2002 Microtek International, Inc. http://www.microtek.com


I49-003502 A, December 2002
B. Mounting filmstrips:
Turn the LightLid 35 over. Insert the Filmstrip front side up
35mm filmstrip front side up along the Mylar
recessed area, with one perforated side sheets
of the filmstrip tucked under the mylar
sheets. For added stability, secure the
other perforated side of the filmstrip
with a piece of adhesive tape.
2. Place the LightLid 35 (with the secured filmstrip or slide to be scanned) on the glass
surface of the scanner. The LightLid 35 can be placed horizontally at the front edge
of the scanner glass bed, or vertically at anywhere on the glass surface, as shown
below.

Horizontal Vertical

3. Select your Scan Material and start scanning.


Launch the ScanWizard 5 scanning software in stand-alone mode or from your
image-editing software, then select your scan material and start scanning. For details
on how to do this, see other documentation included in your scanner package.
ScanWizard 5 has two modes — Standard and Advanced — and each mode has its own
way of selecting the scan material and scanning. Each mode of operation is shown
below.

• Standard Control Panel: In the


Preview window, click the Original
button, and choose Positive Film or
Negative Film, depending on the
material you are scanning. When you
are ready to scan, click on the Scan
To button, and select where the
scanned image will be sent (to image
or OCR editing application, to disk, to
printer, or to e-mail or website
program). For more details, see your
ScanWizard 5 documentation.
• Advanced Control Panel: In the
Preview window, click on the Scan
Material icon, and choose Positive Scan
Material icon
Film or Negative Film, depending on
the material you are scanning; for
Mac OS X, select Positive or Negative
from the Scan Material drop-down
menu. When you are ready to scan,
click the Scan to button, and select
where the scanned image will be sent
(to image or OCR editing application,
to disk, to printer, or to e-mail or
website program ). For more details,
see your ScanWizard 5
documentation.

2 Microtek LightLid 35 Installing and Getting Started


C. Getting the best results

To obtain the best results when scanning with the LightLid 35, set the scan Resolution
to a minimum 600 dpi and the Scaling to 100%. Refer to the diagrams below for more
information on how to set these values in ScanWizard 5 Standard and Advanced Control
Panels.
ScanWizard 5 - Standard Control Panel

Click the Purpose button to


select your Resolution value.
When the drop-down menu
appears, select Custom and
type 600 at the dpi box, as
shown below.

Set Scaling here to 100%

ScanWizard 5 - Advanced Control Panel

Set Resolution here to


600 dpi
Set Scaling here to
100%

Settings window
Settings window in Mac OS 9.x
in Mac OS X

Settings window in Windows

Microtek LightLid 35 Installing and Getting Started 3


D. Using the LightLid 35 Calibrator

The LightLid 35 Calibrator is a program designed for calibrating your LightLid 35 to


ensure that it captures colors accurately when scanning slides and filmstrips. Calibration
is strongly recommended as a procedure for optimizing your scanned image.
A. Install the LightLid 35 Calibrator.
On PC:
1. Place the Microtek CD into your CD-ROM drive. When the Installer screen
comes up, click Exit.
2. Double-click the My Computer icon on the desktop.
3. Locate your CD-ROM drive icon, and right-click the icon to bring up the
Context menu.
4. Choose Open, then double-click the LL35 Calibrator folder to open it.
5. Double-click the setup.exe icon to install the Calibrator. Follow the on-screen
instructions until installation is complete.
On Mac OS 9.x:
1. Place the Microtek CD into your CD-ROM drive. When the Microtek CD icon
appears on the desktop, double-click it.
2. Double-click “For OS 9.x” icon to open Installer screen.
3. Open the folder “LightLid 35 Calibrator”, and double-click the Installer icon.
Follow the on-screen instructions until installation is complete. Once the
Calibrator is successfully installed, the “LightLid 35 Calibrator” icon appears on
the desktop.
On Mac OS X:
1. Place the Microtek CD into your CD-ROM drive. When the Microtek CD icon
appears on the desktop, double-click it.
2. Double-click “For OS X” icon to open the Installer screen.
3. Double-click “LightLid 35 Calibrator” to mount the LightLid 35 Calibrator on
the desktop.
4. Open the “LightLid 35 Calibrator” on the desktop, and double-click “LightLid
35 Calibrator.pkg”.
5. Enter the administrator's name and password when the installation dialog box
comes up. Follow the on-screen instructions until installation is complete. Once
the Calibrator is successfully installed, the “LL35 Calibrator” icon appears on
the desktop.
B. Launch the LightLid 35 Calibrator.
Make sure that ScanWizard 5 is already installed on your system and that your scanner
is powered up. Launch the LightLid 35 Calibrator (Mac OS 9.x) or LL35 Calibrator
(Mac OS X) from your desktop. Alternatively, you
can launch the LightLid 35 Calibrator from the
LightLid 35 Calibrator folder (PC and Mac OS 9.x)
or from the Applications/ScanWizard 5 Folder
(Mac OS X).
Follow the on-screen instructions as shown in the
Calibrator window right (sample taken from
Windows version, which is identical to the
Macintosh except for the Title bar).
Click the “Calibrate” button
to start calibration

4 Microtek LightLid 35 Installing and Getting Started

Das könnte Ihnen auch gefallen