Sie sind auf Seite 1von 12

Geberit Duofix

Installation
Manual
Montageanleitung
Instructions de montage
Istruzioni per il montaggio
Installation Dimensions

19¾"

Product Data
½" NPT

For optional washlet


water supply stop
Product Specifications 71/8"/ 9"
26⅜" 45¼"–
2" 2" 49¼"
Geberit Model No. / Flush volume: 37⅜"–
41⅜"**
• 111.798.00.1 / 1.6/0.8 gpf (6.0/3.0 lpf) 7"
typical
• 111.597.00.1 / 1.28/0.8 gpf (4.8/3.0 lpf)
11"–15"
• For installing 2-hole stud mounted wall-hung FF

washdown water closet fixtures with rear water 0–7¾"


inlet and waste outlet
** assumes a typical seat
• For installation within or in front of drywall panels 3" thickness of 1" and a distance
from fixture rim to
• For installation in front of solid walls 7½" mounting rod centers of 3"
• Fits within minimum 3 ½" (90 mm) framing wall ≥ 12"
or plumbing chase For optional washlet
• Adjustable for fixture seat heights from 15" to electrical outlet box

19" (381 to 483 mm)


• For flush actuator plates Sigma
For 3½" max.
wall thickness
Vertical drainage only

31/8" ⅜"–2"
For 5½" min.
Features 37⅜"–41⅜"**
Seated heigth+22⅜"
wall thickness
For RH, LH and
• Anti-siphon fill valve vertical drainage

• Impact resistant high density polyethylene 51/2"


15"–19"**
(HDPE) tank, insulated to prevent condensation Seated
• 16-gauge, powder-coated, structural steel ≤ 24½"
heigth

tubing rated to 880 lbs. (400 kg) without damage


to finished wall or carrier unit
• Includes installation and rough-in materials
FF FF

Warranty 0–7¾" 0–7¾"

Limited lifetime warranty on tank and carrier.


1¾"–3½" 3½"
10 year warranty on fill valve and flush valve.
One year warranty on actuator plate.

Material Determination
Recommended material for wall surface
construction:
• Gypsum / green board
• Cement board
• Tile backer board
• Ceramic tile surface

Minimum wall material thickness 3/8"


(10 mm)

2 © 06-2017
968.075.00.0 (00)
For convenience, values for a “typical” situation are
included in the following chart:
FOR REFERENCE

Finished Frame Flush Rod Drain


Installation Seat Height Valve Height Outlet
Height (H) Height (R) Height
Installation Requirements (FSH) (FV) (D)
To install tank and carrier, a 2 x 4" wood frame or
15 45 ¼ 37 3/8 11 7
metal frame construction is required. Studs must
be placed 19 3/4" apart (clearance) where carrier 16 46 ¼ 38 3/8 12 8
will be positioned inside the wall. 17 47 ¼ 39 3/8 13 9
18 48 ¼ 40 3/8 14 10
Prepare 19 49 ¼ 15 11
41 3/8
FF: Finished Floor Height ** assumes a typical seat thickness of 1" and a
FSH: Finished Seated Heigth distance from fixture rim to mounting rod centers
ST: Seat thickness, based on seat model of 3". Always refer to the manufacturer
RT: Distance from fixture rim to mounting specification sheet for the latest information!
centers, based on ceramic model These dimensions are used for later, after the
H: Frame Heigth, subject to conditions below: frame is installed:
H = FSH - RT - ST + 34¼" (870) RC: Rod Center-to-Center Distance, based on
These values are not needed at roughing in, but ceramicmodel
may be useful as alternate references: Other calculations (for reference only)
FV: Flush Valve Height (see below) FV = FSH - RT - ST + 26 3/8" (670)
R: Rod Heigth, based on ceramic model and R = FSH - RT - ST
FSH (see below) D = FSH - RT - ST - 4" (100)
D: Drain outlet, based on ceramic model and or
FSH (see below)
FV = R + 26 3/8" (670)
H = R + 34 ¼" (870)
19¾" H D = R - 4" (100)

FV
All dimensions Above Finished Floor (AFF)

ST
RT FSH
R
D

FF

0–7¾"

© 06-2017 3
968.075.00.0 (00)
Duofix Element in Holzständerwand montieren

Installation Overview min. 5½" wall


19¾" or chase

04

FF

RH, LH or vertical drainage runs allowed with


5 ½" minimum wall thickness.
Vertical drainage run only for 3 ½" maximum
walls.

13 mm

07
A
A
H

B
B

4 © 06-2017
968.075.00.0 (00)
2 4
H
A
A

B
FF

3 5

ø ⅜''

© 06-2017 5
968.075.00.0 (00)
6 8

13 mm

10 mm

13 mm

A
H

B
B
B

6 © 06-2017
968.075.00.0 (00)
2

Duofix Element in Trockenbauwand montieren H


min. 5½" wall
19¾" or chase

FF FF

RH, LH or vertical drainage runs allowed with


5 ½" minimum wall thickness.
Vertical drainage run only for 3 ½" maximum
walls. 3
1

13 mm

A
A
H

B
B

© 06-2017 7
968.075.00.0 (00)
4 6

ø ⅜'' 13 mm

PH 3

12"

5 12"

13 mm

A
H

PH 3

B
B 12"
B

8 © 06-2017
968.075.00.0 (00)
3
Abgangsbogen montieren

min. 3½" min. 5½"


wall wall
1¾" 3½"

1
min. 3½" wall min. 5½" wall

1¾" 3½"

Use supplied flexible


coupling (optional)

≥ 45° ≥ 45°

≤ 45° ≤ 45°

© 06-2017 9
968.075.00.0 (00)
4
Wasseranschluss montieren

1
1 2
1

3 3

¾"

½"
5

NPT ½"
elbow

2
1

10 © 06-2017
968.075.00.0 (00)
6
Stromanschluss bei Duofix Element vorbereiten

`
1¾"

7
9"
7⅛" /
ø 1½"
1⅜"
3⅛"
4"
ø 3"
5½"

8
3½"

9"
7⅛" /
ø 1½"
1⅜"
ø 3"
4"
ø 5½"

© 06-2017 11
968.075.00.0 (00)
Geberit , 2100 Clearwater Drive, Des Plaines, IL 60018-5999 Geberit International AG, Schachenstrasse 77, CH-8645 Jona
Phone: (847) 803 5000 T +41 55 221 63 00
Fax: 847/803-5454 F +41 55 221 63 16
For Technical Assistance: 800 / TEC-TRUE (800-832-8783) documentation@geberit.com
➔ www.geberit.us ➔ www.geberit.com

12 © 06-2017
968.075.00.0 (00)

Das könnte Ihnen auch gefallen