Site 1 / Building 2 / Storey 1 / Philips Lighting WL120V LED12S/830 1xLED12S/830/- / Philips Lighting - WL120V LED12S/830
(1xLED12S/830/-)

Philips Lighting WL120V LED12S/830 1xLED12S/830/-


CoreLine Wall-mounted – the clear choice for LED Whether for a new
building or renovation of an existing space, customers want lighting
solutions that provide quality of light and substantial energy and
maintenance savings. The new CoreLine Wall-mounted range of LED
products can be used to replace traditional wall-mounted luminaires
incorporating compact fluorescent lamps. The process of selecting,
installing and maintaining is so easy – it’s a simple switch.

Light output ratio: 99.94%


Lamp luminous flux: 1200 lm
Luminaire luminous flux: 1199 lm
Power: 18.0 W
Luminous efficacy: 66.6 lm/W

Colorimetric data
1xLED12S/830/-: CCT 3000 K, CRI 100

Luminous emittance 1 / Polar LDC


105° 105°

90° 90°

75° 75°

60° 60°

160

45° 45°
240

320

30° 15° 0° 15° 30°

cd/klm η = 100%
C0 - C180 C90 - C270

Page 1
perncangan on progres 9/8/2017

Site 1 / Building 2 / Storey 1 / Philips Lighting WL120V LED12S/830 1xLED12S/830/- / Philips Lighting - WL120V LED12S/830
(1xLED12S/830/-)

Luminous emittance 1 / Linear LDC


350

300

250

200

150

100

50

90.0° 67.5° 45.0° 22.5° 0.0° 22.5° 45.0° 67.5° 90.0°


cd/klm η = 100%
C0 - C180 C90 - C270

Luminous emittance 1 / Cone diagram

E(0°) 1445
1.6 E(C90) 58.2° 106
0.50 1.6 E(C0) 58.3° 105

E(0°) 361
3.2 E(C90) 58.2° 26
1.0 3.2 E(C0) 58.3° 26

E(0°) 161
4.8 E(C90) 58.2° 12
1.5 4.9 E(C0) 58.3° 12

E(0°) 90
6.5 E(C90) 58.2° 6.6
2.0 6.5 E(C0) 58.3° 6.6

E(0°) 58
8.1 E(C90) 58.2° 4.2
2.5 8.1 E(C0) 58.3° 4.2

E(0°) 40
9.7 E(C90) 58.2° 2.9
3.0 9.7 E(C0) 58.3° 2.9
Distance [m] Cone diameter [m] Illuminance [lx]
C0 - C180 (Beam angle: 116.6°)
C90 - C270 (Beam angle: 116.4°)

Page 2
perncangan on progres 9/8/2017

Site 1 / Building 2 / Storey 1 / Philips Lighting WL120V LED12S/830 1xLED12S/830/- / Philips Lighting - WL120V LED12S/830
(1xLED12S/830/-)

Luminous emittance 1 / Luminance diagram


C225 C180 C135

C270 C90

4000

8000

10000

12000
C315 C0 C45

cd/m²
g = 65.0° g = 75.0° g = 85.0°

Luminous emittance 1 / UGR diagram


Glare evaluation according to UGR
ρ Ceiling 70 70 50 50 30 70 70 50 50 30
ρ Walls 50 30 50 30 30 50 30 50 30 30
ρ Floor 20 20 20 20 20 20 20 20 20 20
Room size Viewing direction at right angles Viewing direction parallel
X Y to lamp axis to lamp axis

2H 2H 18.2 19.5 18.5 19.8 20.2 18.2 19.5 18.5 19.8 20.1
3H 20.1 21.3 20.5 21.6 22.0 20.1 21.3 20.4 21.6 22.0
4H 21.0 22.2 21.4 22.5 22.9 21.0 22.1 21.4 22.5 22.9
6H 21.9 23.0 22.4 23.4 23.8 21.9 23.0 22.4 23.4 23.8
8H 22.4 23.5 22.9 23.9 24.3 22.4 23.5 22.9 23.9 24.3
12H 23.0 24.0 23.4 24.4 24.8 22.9 23.9 23.4 24.4 24.8
4H 2H 18.9 20.1 19.3 20.4 20.8 18.9 20.1 19.3 20.4 20.8
3H 21.0 22.0 21.5 22.4 22.9 21.0 22.0 21.5 22.4 22.9
4H 22.1 23.0 22.6 23.5 23.9 22.1 23.0 22.6 23.5 23.9
6H 23.3 24.1 23.8 24.5 25.0 23.2 24.0 23.7 24.5 25.0
8H 23.9 24.6 24.4 25.1 25.6 23.8 24.6 24.3 25.0 25.6
12H 24.5 25.2 25.0 25.7 26.2 24.5 25.1 25.0 25.6 26.2
8H 4H 22.6 23.3 23.1 23.8 24.3 22.6 23.3 23.1 23.8 24.3
6H 24.0 24.6 24.5 25.1 25.6 24.0 24.6 24.5 25.1 25.6
8H 24.7 25.3 25.3 25.8 26.4 24.7 25.3 25.3 25.8 26.4
12H 25.6 26.0 26.1 26.6 27.2 25.6 26.0 26.1 26.6 27.2
12H 4H 22.7 23.4 23.2 23.9 24.4 22.7 23.3 23.2 23.8 24.4
6H 24.2 24.7 24.7 25.2 25.8 24.1 24.7 24.7 25.2 25.8
8H 25.0 25.5 25.6 26.0 26.6 25.0 25.5 25.5 26.0 26.6
Variation of the observer position for the luminaire distances S
S = 1.0H +0.1 / -0.1 +0.1 / -0.1
S = 1.5H +0.2 / -0.3 +0.2 / -0.3
S = 2.0H +0.3 / -0.5 +0.3 / -0.5

Standard table BK09 BK09

Correction Summand 8.4 8.4

Corrected glare indices referring to 1200lm Total luminous flux

The UGR values are calculated in acc. with CIE Publ. 117. Spacing-
to-height ratio = 0.25