Today, In this post, we will learn about Blowdown Valve (BDV) to flare system
configuration.
During emergency or depressuring, the BDV valve opens to release high
pressure fluid flow to flare system.
The following are guidance for developing the BDV (Blowdown Valve) to flare system
1. You must determine the maximum flowrate through this BDV line during depressuring. So, you have to
conduct depressuring study at first.
2. Based on the maximum flow (peak blowdown rate), select the appropriate size that meet the velocity and Rho
v2 criteria.
Most of Engineering Company consider maximum velocity of 60m/s (or 200 fps).
Consider maximum Rho v2 of 200000 kg/m s2. (But, some other Engineering Company use the lower of
150000 kg/m s2 in their standard practice).
The Rho v2 to be limited to prevent turbulence – induced vibration of flare piping based on the lesson learn of
experience in many company.
I suggest you to consider maximum Rho v2 of 150000 kg/m s2 for new design.
https://process-eng.blogspot.com/2018/08/blowdown-valve-bdv-to-flare-system.html 1/2
10/14/2019 Process Engineer: Blowdown Valve (BDV) to Flare System
pressure).
For general practice, the distance from BDV to RO should be more than 0.6 meter (or other company use standard
of minimum 3ft).