Modification Log File for QProg

RELEASE 0.06
NEW FEATURES:
1 Network Communication (flash rom 020208 or newer installed!)
- Menu Options added in Program Menu for network communication
- Get report menu option added for Consolidation
- Program Text 43, 44, 435 and 436 added for network options

RELEASE 0.07
NEW FEATURES:

1 Name is changed to QPROG.EXE and the default Icon is changed.


2 All Parameters and Options now have a text. Please check the translation file for the correct texts.
3 When QPROG starts it will look for a file called QPROG.BMP and will show this bitmap on the
main screen. Note that when the main program name is changed also this name must be
changed!
4 When QPROG starts it will look for a file called QPROG.ICO and will use this icon instead of the
standard Quorion icon. Note that when the main program name is changed also this name must
be changed!

RELEASE 1.00
NEW FEATURES:
1 It is now possible to clear a complete program text. It was always filled with spaces so it was
always printed as an empty line on the cash register tickets. Now when the text is empty it will not
print.
2 PROGRAM TEXT# 259, 260, 261, 262, 263, 540, 672, 673, 674, 675, 676 are used now.
3 Fixed Key “KEYBOARD SHIFT” (key code 30) added to Keyboard programming.
4 Fixed Key “PROFORMA” (key code 31) added to Keyboard programming.
5 Fixed Key “NUMBER ENTRY” (key code 256) added to Keyboard programming.

RELEASE 1.01
NEW FEATURES:
1 PROGRAM TEXT 223 is used now.
2 Make ROM Config BUTTON added in Config MENU.

RELEASE 1.02
NEW FEATURES:
1 PROGRAM TEXT 132, 224, 256, 257, 541, 677, 678, 679, 680, 681, 682 & 683 are used
now.
2 CLERK INTERRUPT BUFFER FILE in File Configuration activated.

RELEASE 1.03
NEW FEATURES:

1. Currencies Report Sizes selection is removed from CONFIG->CHANGE REPORT TOTALIZERS


SIZES menu because it was not used.
2. PROGRAM TEXT 265 has been changed. This text is displayed when programming the balance
functions. The function of the option it was pointing to didn’t correspond with the text. It must be
DISPLAY STORED BALANCE.

BUGS SOLVED:
1. In some program windows QPROG used a TRUETYPE font as default which gave problems when
the system character set was not Western Europe. In order to avoid this the default fonts used are
now not true type. This problem occurred in the Keyboard and System Texts Windows.
2. When the inventory fields were active in the PLU configuration QPROG would always change the
sign of the inventory to positive. Now the sign and decimal point are also displayed and sent back
correctly to the register.
3. It was not possible to put character with a code above 127 on the ASCII keyboard for text
programming. This has been solved.

RELEASE 1.04
BUGS SOLVED:

1. Problems were reported using the Help System which is built in QPROG. The problems were not
displaying help in Windows versions other then 98 or not displaying help at all when the
QPROG.DOC file was opened and saved again with a different version of WORD.

RELEASE 1.05
NEW FEATURES:

1. OPTION 2-3 is set in the Balance Function used to select the TYPE of INVOICE the register will not
print the INVOICE# and not store the INVOICE total in the INVOICE report. (text# 253)
2. It is possible to activate the option for free balance number assignment (text 225).
3. OPTIONS 107, 108, 109 and 110 have texts now (684, 685, 686, 687).
4. When OPTION 2-1 and 2-2 in the USER report have now (251,252).

RELEASE 1.06
NEW FEATURES:

1. PARAMETER 92 (Text# 542) and 93 (Text#453) are added for TYPE and PORT of Electronic scale
2. When OPTION 1-5 in the DEPARTMENT (or PLU when individual options are active) is SET the
register will automatically request the weight from the scale when no quantity entry is done and the
department or a PLU linked to this department is used. (Text# 249)
3. A new key called SCALE (key code 258) has been created which will request the weight from the
scale when pressed. The received weight will be displayed and then the PLU or department can be
selected. (Text# 250)
4. System->Fixed Texts->Error Message 47 “SCALE ERROR” has been added.
5. System->Fixed Texts->Error Message 48 “NOT AUTHORIZED” error has been added.
6. OPTION 1-7 in the clerk file has been added.
7. OPTION 2-3 in the User Report File has been added.
8. SYSTEM OPTION 111, 112, 113, 114, 115 and 116 are added.

RELEASE 1.07
NEW FEATURES:

1. When using scan codes for PLU QPROG now gives an error when you try to create a PLU with scan
code ZERO.
2. System->Fixed Texts->General 51 “S-Total” has been added to activate print total in report list.
3. Text #246 for Option 1 in the Report List has been added “Print Total”.
4. QPROG Report Module will recognize record which indicates NEW ARTICLES when scan codes are
used and will print/display it in the reports.
5. Text #245 for Option 1-5 in the Special Itemizer function is added.
6. Text #694 for OPTION 117 (Direct Secret Clerk Code Entry) is added.
7. Text #244 for Option 1-1 in the Condiment Table File is added.

RELEASE 1.08
NEW FEATURES:

1. Text# 241 used for Fixed Key “Keyboard Level# “


2. Text# 242 used for OPTION 1-3 (Singapore GST Calculations) in Tax Functions.
3. Text# 243 used for OPTION 2-4 (Print New Balance) in Balance Functions.
4. Text# 545 used for PARAMETER 95 (Number of Copies).
5. Text# 695, 696, 697, 698, 699, 700, 701, 702, 703 used for SYSTEM OPTIONS 118, 119, 120, 121,
122, 123, 124, 125 and 126.

RELEASE 1.09
NEW FEATURES:

1. New Menu Option for sending computer time and date to the connected register in “Sent to Register”.
Text# 45 is used for the menu option “Time and Date”.
2. Text# 233 used for OPTION 1-6 in Drawer Total Function (“No Declaration“).
3. Text# 234 used for OPTION 2-4 in User Report Function (“Cash Declaration”).
4. Text# 235 used for OPTION 1-2 in Macro Function (“Store Key codes”).
5. Text# 236 used for OPTION 1-5 in Price Level Function ("Quantity X 2.0").
6. Text# 237 used for OPTION 1-4 in Price Level Function ("Quantity X 0.5").
7. Text# 238 used for OPTION 1-3 in Price Level Function ("Shift on Base Level").
8. Text# 239 used for OPTION 1-2 in Price Level Function ("Print Level Text with Item").
9. Text# 240 used for Fixed SHIFT ON SHIFT Key(‘s) ("Price Shift#")
10. Text# 704, 705 and 706 used for SYSTEM OPTIONS 127, 128 and 129.

RELEASE 1.10
NEW FEATURES:

1. Text# 231 used for OPTION 1-8 in Tender Function (“EFT Cheque (France)“).
2. Text# 232 used for OPTION 1-7 in Tender Function (“EFT Card Function”).
3. Text# 546 used for PARAMETER 96 (Type EFT Terminal).
4. Text# 547 used for PARAMETER 97 (Port EFT Terminal).

PROBLEMS SOLVED:
1. When in the PLU configuration the option for “Extra Department Selection” was set QPROG would
not include it in the record size calculation. This could cause overwriting of the other fields when the
PLU was used on the register.
2. Editing the WLU (Window Look Up) file was not working correctly anymore in release 1.09. This was
caused by the changes made for the MACRO key codes.

RELEASE 1.11
NEW FEATURES:

1. Text# 230 used for OPTION 1-1 in Modifier Function (“Modifier Text is PLU#“).
2. Text# 707 and 708 used for SYSTEM OPTIONS 130 and 131.

RELEASE 1.12
NEW FEATURES:

1. Indonesia

RELEASE 1.13
NEW FEATURES:

1. Validation Indonesia

RELEASE 1.14
PROBLEMS SOLVED:

1. Problems were reported when using a non standard character set. The HELP system wouldn’t display
the correct characters. This has been solved by changing the character set used by the help system
to the true type font ARIAL .

RELEASE 1.15
NEW FEATURES:

1. The File Edit Window is now resizable.


2. Action Tables can now be used when Flash ROM version xx030117 or newer is installed. See
MULTIBUY.DOC for more detailed information.
2. Text# 226, 227, 228, 229 are used now.
3. Text# 548, 549, 550, 551, 552, 553, 545 are used now.
4. Text# 709, 710, 711, 712, 713, 714, 715, 716, 717, 718, 719, 720, 721, 722, 723, 724, 725, 726, 727,
728, 729, 730, 731, 732 are used now.

PROBLEMS SOLVED:

1. When in the CONFIGURATION menu the number of GROUPS was set to ZERO QPROG would add
the size of the Base Department Record (without report information) to the Department Record size
which would result in reserving more memory then required for the department file.
RELEASE 1.16
NEW FEATURES:

1. In the KEYBOARD programming window it is no possible to enter the function number directly in the
function number field. In this way it is not necessary to use the dropdown list with large PLU files
2. In the CONFIGURATION->GENERAL OPTION it is now possible to activate the Non-Resetable
Grand Total. The NRGT can be printed on a USER Z-report by option.
3. Text# 555, 556, 557, 558, 559, 560, 561, 562, 563, 564, 565, 566, 567, 568, 569, 570, 571, 572 are
used now.

RELEASE 1.17
NEW FEATURES:

1. Print Option in SYSTEM PARAMETERS and SYSTEM OPTIONS window.


2. Modem Communication. See MODEM INITSTRING in help file for more info on modem initialization.
3. SETTINGS menu renamed to COMMUNICATION menu.
4. DIRECT and NETWORK CONNECTION MOVED from PROGRAM menu to COMMUNICATION
menu.
5. DIAL (Text# 576), HANGUP (Text# 577), DIAL PROMPTING (Text# 733), TIME AND DATE and
MODEM INIT STRING (Text# 734) added to COMMUNICATIONS menu.
6. Tax Shift Keys can be programmed in Keyboard Programming.
7. Text# 736 and 737 are used for System Options 155 and 156.

RELEASE 1.18
NEW FEATURES:

1. Backup and Restore Cash Register Memory functions implemented. For service purposes it is now
possible to make a copy of the cash register memory and restore it. Note that the CONFIGURATION
is part of the backup so it is not possible to backup change the configuration and restore the memory.
The WORKING memory which holds the current transaction is NOT saved/restored.
2. Text# 738, 739, 740, 741, 742, 743, 744, 745, 746 and 747 are used now.

PROBLEMS SOLVED:

1. When setting the lines of Endorsement Message Number 1 to zero QPROG would also set
Endorsement Message Number 2 to zero lines.

RELEASE 1.19
NEW FEATURES:

1. It is possible to program the new 156 keyboard. When more keyboard levels are used you must also
select “Support Large Keyboards” in the Keyboard File configuration.
2. Keyboard window can be made larger.
3. COM5 to COM8 added.
4. Texts# 748 to 782 are used now.

PROBLEMS SOLVED:
1. When copying an application and CLEAR the PLU file QPROG wouldn’t copy the DEPARTMENT file.
2. When the NUMBER of Keyboards in the configuration was set to ONE instead of ZERO and the
program was installed in a register it was not possible to LOAD the program back from the register.
You would get a COMM ERROR on the keyboard file. When the NUMBER was set to ZERO or larger
then ONE there was no problem.
3. When using 2 PLU captions and the second one was smaller then the first one QPROG would also
use the size of the second one for the first caption.

RELEASE 1.20
NEW FEATURES:

1. This version supports the CR1000 and QMP3000 models. In the configuration menu you can select
the model. It is possible to convert from QMP3000 to CR1000 but the program will automatically
remove all functions which are not supported by the CR1000 and the changes cannot be undone!
Note that there is NO check on the model when installing the program in the register but when the
model doesn’t match the model as specified in the configuration the program will NOT work.
2. It is now possible to change the text, font, colors and/or bitmap of each individual key on the
keyboard.
3. You can store the keyboards in a separate file so it is possible to make standard keyboard which can
be reloaded. The keyboard is saved in a files with the extension “*.QKB”. In this file the keyboard
type, transaction keys, system keys, font, text and color for each key is stored.
4. The keyboard information for the application is stored in the file with extension “appname.Q57”.
5. Texts# 783 to 794 are used now.

RELEASE 1.21
NEW FEATURES:

1. In the COMMUNICATION menu a new option for Report Format has been added. It is now possible
to store the received reports in Text (CSV), Binary (QRB) or Text AND Binary format. This can be
used if you don’t want the end user to open and/or change the file using a text editor. In BINARY
mode QPROG will subtract ‘0’ (H’30’) from every character received before it is written to disk.
- The binary reports are stored in files with the extension “QRB”.
- When the option “Text AND Binary” is set QPROG will store the report in CSV format and
automatically create a BINARY file with the same name but extension QRB.
- When the option “Text AND Binary” is set QPROG will show all files with extension CSV and QRB
when you select the option to view a report. QPROG will automatically detect the file type when
opened for viewing.
- When the option “Text AND Binary” is set QPROG will automatically delete the QRB file when the
CSV file is selected.
2. Texts# 795 to 798 are used now.

PROBLEMS SOLVED:

1. QPROG would show the balance files in the File Edit Menu even when there was no information
stored.
2. When QPROG was set for CR1000 the macros with key code were not sent correctly and only the
first key code was working.

RELEASE 1.22
NEW FEATURES:
1. It is now possible to print the different files. In the EDIT FILE menu there is now a button PRINT.
QPROG will print the contents of the file on the selected printer.
- It uses a standard Font with Size 10. When the line doesn’t fit on the page it will use Font Size 8
instead.
- At the moment QPROG will always print the complete file. It is not possible to specify a range.
- When the line doesn’t fit on the page it is possible to change the Paper Orientation in the Print
Dialog.
- When in the Edit menu a column is resized so it is not show on the screen it is also NOT printed.
In this way it is possible to suppress a column on the printout.
- When the column with the CAPTION is EMPTY the complete line is not printed. In this way it is
possible to suppress not used functions.
- When using Random PLU codes QPROG will only print the used PLU.
2. When model is set as CR1000 it is now possible to activate KP in the Department and PLU
configuration menu.

RELEASE 1.23
NEW FEATURES:

1. When the model is set to CR1XXX it is now possible to activate maximum 4 Special Itemizers.
2. Text# 799 to 812 are used now.
3. QPROG.DOC is updated with the new options.

RELEASE 1.24
NEW FEATURES:

1. When using PLU inventory in a NETWORK you can now set an option so QPROG only sends the
new inventory to Register# 1 and not to all the registers in the network.
2. Editing files is improved. It is now possible to select a Range of Rows and/or Columns when editing a
Function File.
3. Importing and Exporting function files are now possible.
4. When Network communication is selected it is now possible to select more then one register when
SENDING Information. QPROG will communicate to all selected registers automatically.
5. Text# 813 to 822 are used now.

RELEASE 1.25
PROBLEMS SOLVED:

1. A in QPROG 1.24 was reported which is caused by the Borland Libraries. Sometimes when editing
files QPROG will give message "List Index out of bounds". This has been corrected.

RELEASE 1.26
NEW FEATURES:

1. Text# 823 to 826 are used now.


PROBLEMS SOLVED:

1. When editing the keyboard and after a change the CANCEL button was pressed QPROG would
cancel the complete keyboard editing and change it back to default again because the wrong file was
recalled.

RELEASE 1.27
NEW FEATURES:

1. Text# 827 to 838 are used now.


2. This version now supports the CR1XXX Restaurant Version. Note that you must have a Cash
Register which supports these functions in order to use them.
3. The Communication Menu has changed and all parameters and options are now displayed in a
separate menu. Don’t forget to update the QPROG.DOC file incase you changed or translated it.
4. QPROG now support COM ports up to 255. In this way it is possible to use VIRTUAL COM Ports.

RELEASE 1.28
PROBLEMS SOLVED:

1. When using COM ports higher then 9 QPROG would give “ERROR OPENING COM PORT”” when
used under Windows 2000 or Windows XP. When using Windows 98 there was no problem. It was
caused by the Windows API which didn’t accept “COMxxx” as parameter but required “\\.\COMxxx”
instead for Windows 2000 and XP. After checking the documentation it seems that this was first
discovered in Windows 95 and corrected in Windows 98 but for some reason came back in the
versions after 98.
2. The default Text# 749 and 836 are changed from “QMP 1XXX” to “CR 1XXX”.

RELEASE 1.29
NEW FEATURES:

1. When SYSTEM OPTION 8 (E-Journal Reset Not Allowed) is set QPROG will not display Report# 102
in the report list.
2. When Editing Files the TAB key can now be used to move to the next field.
3. The QTOUCH keyboard can now be programmed.
4. Text# 839 to 850 are used now.

PROBLEMS SOLVED:

1. In the PARAMETER menu and HELP file PARAMETER 104 and 105 were switched. Parameter 104
is the TYPE and 105 is the PORT# of the TAP controller.
2. When running under Windows XP and a SYSTEM OPTION was changed by using the Mouse the
option in the next column was changed. This was caused by the Borland Display Library 4.0 in
combination with XP. After upgrading to release 6.0 this has been solved.

RELEASE 1.30
NEW FEATURES:

1. PLU Inventory Amount size re-activated for CR 1XXX Restaurant version. This field can be used to
specify the inventory quantity when SYSTEM OPTION 192 is SET.
2. Maximum number of Groups for the QMP3XXX series is increased to 255.
3. Clerk Interrupt Buffers have been activated for CR1000 Series. Note that you need D0040624 or later
in the register.

PROBLEMS SOLVED:

1. When an application was read from the cash register using QPROG 1.29 the Graphic Logo’s were
not stored. This was caused by the upgrade of the development tool CBUILDER 4.0 to 6.0. The
handling of bitmap files was changed.

RELEASE 1.31
NEW FEATURES:

1. Text# 850 to 868 are used now.


2. From this release QPROG supports a CUSTOMER ID in the CONFIGURATION MENU which can be
used to protect the application and cash register from unauthorized access (QMP Release XX040730
or newer).
· When set you can only access the cash register by computer when the correct CUSTOMER ID is
set.
· When an application which has a CUSTOMER ID is loaded from DISK you will be asked for the
CUSTOMER ID. When the entered ID is not corrected you are not allowed to open the
application.
· When an application is loaded in QPROG the CUSTOMER ID of the application will be used
during communication.
· When NO APPLICATION is loaded QPROG will ask you for the CUSTOMER ID before every
communication command.
· After an application is installed in the register you can only change the Customer ID in the
register by programming mode 98 (lock in P) or by making a hardware reset. It is not possible to
CHANGE the ID using QPROG.

PROBLEMS SOLVED:

1. When another keyboard file was loaded with different key size you had to exit the keyboard
programming before the key size were adjusted.
2. When programming the QTouch Keyboard and a range of keys was cleared it was not possible to
change the background color until a function was programmed again.
3. When restoring a Memory Backup the QPROG wouldn’t send the INIT command so the Graphic Logo
was not initialized and the Configuration was not automatically stored in QTouch.

RELEASE 1.32
NEW FEATURES:

1. It is now possible to make a connection using Ethernet. At the moment only the QTouch model
supports the Ethernet connection. In order to open an ETHERNET connection you have to supply the
IP ADDRESS of the register and set the PORT to 9999 which is interpreted by QDRIVER as the
ETHERNET port. See also QMP_LAN.DOC for the settings of the cash register.

Example:
PORT=9999
IP=192.168.2.200

2. Text# 868 to 881 are used now. DON’T forget to enter TEXT#876 and #877 when you are using your
own transaction file and you want to use the Ethernet Connection.
3. CR1000 series number of P.O. and R.A. function are increased to maximum 4.
PROBLEMS SOLVED:

1. It was not possible to change the field and text separators when exporting data. They were always set
back to the original values. When the separators were changed when IMPORTING they were saved
and also valid for exporting.

RELEASE 1.33
PROBLEMS SOLVED:

1. When an application was protected with a Customer ID (see release 1.31) and QPROG prompted for
the ID when opening the application the entered ID would overwrite the MODEM INITIALIZATION
string as programmed in the COMMUNICATION SETTINGS menu.

RELEASE 1.34
NEW FEATURES:

1. Customer ID Protection is now also supported for the CR1000 series.

RELEASE 1.35
NEW FEATURES:

1. Text# 882 to 894 are used now.


2. Activation of 2 x Endorsement messages in CR1000 restaurant version.
3. Automatic change of scale or window size when editing QTOUCH keyboard so keyboard is
always completely drawn.
4. It is possible to take the Binary Electronic Journal Report 103.
5. It is possible to view Detailed Balance Reports and Electronic Journal Report 103.
6. Store Scancodes in E-Journal in E-Journal configuration.
7. Store Scancodes on Balances in Balance Item Block File configuration.

RELEASE 1.36
NEW FEATURES:

1. Text# 895 and 896 are used now.


2. Fixed Function “Seat#” with keycode 280 is implemented. See also SYSTEM PARAMETER 111.
3. When entering the PLU INVENTORY field QPROG now accepts xxxA as entry. This entry is
processed by the cash register as a PLU INVENTORY LINK which means that this PLU will link to
inventory PLU xxx.
4. The BITMAP option when editing a QTOUCH keyboard has been removed to avoid confusion
because it is not supported.
5. It is now possible to select a bigger size for the ALPHA and PROGRAM keys so the are easier to read
when the keyboard is printed.
6. Program text 113 (IP BASE ADDRESS), 114 (SUBNETMASK) and 115 (DEFAULT GATEWAY) are
used when ethernet is installed (Only Qtouch).
7. Program text 116 (InvUnit) is used for the INVENTORY UNIT SIZE.

RELEASE 1.37
NEW FEATURES:

1. Text# 897 to 906 are used now.


2. Menu/Arrangements can now be activated and used when release 050201 or newer is installed in the
register.
RELEASE 1.38
PROBLEMS SOLVED:

1. When a ROM CONFIGURATION FILE was made for a version with an 8 or 16 line display the logo
for the display was stored wrong.

RELEASE 1.39
NEW FEATURES:

1. Text# 906 to 925 are used now.


2. When using an Electronic Journal you can now take Report 104. Note that you need version 050428
or newer in the register when you are using a Binary Electronic Journal.
3. The Report Option “Close Open Transaction” is now stored in the Qprog settings file. It now keeps the
last setting instead of by default select the option.
4. A new Keyboard type “Qtouch 56 Graphic Keys” for the QTOUCH has been added. When this
keyboard is selected you can put bitmaps on the keys. Note that you need software 050428 or newer
in your Qtouch. The bitmaps have a fixed format of 256 colors. The size for the small keys is 69 x 53
pixels and the large keys 91 x 53 pixels. The keyboard bitmaps are stored in the file “app.Q65”.

RELEASE 1.40
PROBLEMS SOLVED:

1. It was not possible to load an existing keyboard (QKB) file when keyboard type “Qtouch 56” or
“Qtouch 56 Graphic Keys”.
2. When installing or sending the complete program to a Qtouch Qprog would not sent the re-draw
screen command which caused that the keyboard was not stored and displayed.

RELEASE 1.41
NEW FEATURES:

1. Text# 926 to 934 are used now.


2. “Configuration->General Options->Validation Counter” has been added.
3. “Configuration->General options->Period 3 and 4 for Backup” has been added for KLIER project.
4. Printing of new 156 keyboard. Qprog will now print extra lines for cutting the paper.
5. CR1000 standard modifiers (100), salespersons (16) and binary journal activated.
6. CR1000 restaurant salespersons (16) and binary journal activated.

PROBLEMS SOLVED:

1. When sending updates QPROG would increment the progress counter with 2 instead of 1 step which
caused the progress counter to stop when 50% of the updates was sent although QPROG was still
sending.

RELEASE 1.42
NEW FEATURES:

1. Text# 935 to 945 are used now.


2. In the CR1000 standard & restaurant version the GROUPS are increased to 20.
3. In the CR1000 restaurant version 1 line of text can be linked to a table.
4. It is possible to enter a Negative balance limit amount in the Balance Total File(s).
5. Programming of HEX key on Alfa keyboard which can beused to enter hexadecimal Ascii codes.
6. A Backup now also stores the QTOUCH keyboard in QB0 (text+colors) and QB1 (bitmaps) files. A
backup of a QTOUCH consists out of 3 files “backup.QBU”, “backup.QB0” and “backup.QB1”
7. The SYSTEM OPTIONS windows has been increased to display 320 options.
RELEASE 1.43
NEW FEATURES:

1. CR1000 series number of Discount functions is increased to maximum 4.

RELEASE 1.44
NEW FEATURES:

1. Text# 946 to 948 are used now.

PROBLEMS SOLVED:

1. When sending only program changes to a Qtouch it could happen that Qprog would not sent the re-
draw screen command which caused that the keyboard change was not stored and displayed.
2. When the Customer ID was activated and network communication was started QPROG would not
login to the slave registers when more then one register was selected for communication. When a
slave was addressed directly there was no problem.

RELEASE 1.45
NEW FEATURES:

1. CR1000 series number of Clerks is increased to maximum 50.


2. CR1000 series number of Salespersons is increased to maximum 50.
3. CR1000 series second PLU caption has been activated.
4. CR1000 series Extra GROUP selection on Department and PLU has been activated.

RELEASE 1.46
PROBLEMS SOLVED:

1. CR1000 series second PLU caption although activated in the configuration screen but was always set
back to zero.
2. CR1000 series Extra GROUP selection on Department and PLU although activated in the
configuration screen were always reset.

RELEASE 1.47
NEW FEATURES:

1. Text# 134 and 949 to 959 are used now.


2. CR1000 series number of Discounts is increased to maximum 8.
3. Extra keyboard activation in the configuration.

PROBLEMS SOLVED:

1. The TARE weight table were not converted to the CR1000 series format when sending it to a
CR1000.

RELEASE 1.48
NEW FEATURES:

1. Text# 960 to 981 are used now.


2. Touch 44 Keys (64K) for Concerto
3. Touch 56 Keys (64K) for Concerto

PROBLEMS SOLVED:

1. PLU prices of 12 digits were not converted correctly when used with the CR1000 series.
2. The Report Sizes for Period 3 and 4 are automatically set to the same size as Period 2 when CR1000
series is selected. This is done to avoid entry problems on the register when using prices of 12 digits
because the register also checks the sizes for Period 3 and 4 on the CR1000.

RELEASE 1.49
NEW FEATURES:

1. The number of texts in the translation file has been increased from 1000 to 2000. The program will
automatically detect the old and new file sizes.
2. Text# 982 to 1009 are used now.
3. The PARAMETER and OPTION menu are now combined into one MENU in which you can select the
option and parameters by group so it is easier to find a certain option or parameter.

RELEASE 1.50
NEW FEATURES:

1. Text# 1009 to 1013 are used now.


2. In the communication menu it is now possible to select an external (WAN) IP address for
communication using an external network. The WAN address is the address of DSL modem or router
to which the register is connected. You must be sure the router or DSL modem is programmed for
port forwarding. Register#1 is using port# 2030, register# 2 port# 2031 etc. In modem or router you
must program that all data for port# 2030 is forwarded to the IP address of register# 1 with port# 2030
and data for port# 2031 to ip address of register# 2 with port# 2030. On our website in the section
“Service Tips” you can find a WAN tutorial which explains how to setup a router and also how to use
DNS.
3. The MAXIMUM number of PLU for the QMP 3000 series has been increased to 55000.
4. In the Table, Room and Account configuration it is now possible to activate a price level field and/or
discount field for each balance. With activated it is possible to assign a fixed price level and/or
discount to a balance. The discount price level is selected the moment the balance is openend and
the discount is calculated when the balance is paid. When one of these new options is activated the
maximum number of text lines is 5 instead of 6!!

RELEASE 1.51
PROBLEMS SOLVED:

1. When changing the program configuration it could happen that QPROG didn’t update the
configuration correctly when the FILE configuration screen was not on top of the MAIN configuration
screen when closed. QPROG updated the configuration when it received the PAINT command from
Windows which was not issued in this case. This could result in wrong start addresses of the files in
the cash register memory. The problem was corrected the next time the configuration screen was
opened and closed with the OK button.

RELEASE 1.52
NEW FEATURES:

1. For the standard CR1000 series it is now possible to activate maximum 5000 tables with maximum 3
lines of text and discount and/or price level selection which can be used for account customers. You
can only activate 1 balance function which can be used to open the table and there is no buffer for
detailed invoices.
RELEASE 1.53
NEW FEATURES:

1. It is possible to activate pricelevel by clerk in the clerk configuration menu. You must have version
060613 or newer installed in your register in order to use it.
2. Text# 1014 to 1023 are used now.

RELEASE 1.54
NEW FEATURES:

1. It is possible to activate the Belgian Ticket Code in General Options Configuration Menu.
2. It is possible to activate the Clerk Sign On/Off times and Time Periods in the Clerk Configuration.
3. In the User Report List it is possible to select the Clerk Time Report.
4. Text# 1024 to 1028 are used now.
5. The routines to send a record via RS232 are modified so they send a comlete block instead of byte
by byte. This will improve in most cases the communication when an USB to RS232 converter is
used. Some converters have problems with byte by byte transmission which would result in slow
communications or errors.

RELEASE 1.55
NEW FEATURES:

1. Text# 1029 to 1047 are used now.

SOLVED PROBLEMS:

1. The change in the RS232 communication routines for sending a record as one block could cause
a lockup of QPROG when no register was connected when starting communicating.

RELEASE 1.56
NEW FEATURES:

1. Text# 1048 to 1051 are used now.


2. For the Flat keyboard the black key rectangel is not printed anymore.
3. For the Flat 156 keys an extra dotted line is printed for the new Concerto Flat keyboard cover.
4. The width of the columns in the Report View window are automatically adjusted when they don't
fit.

SOLVED PROBLEMS:

1. The printing size of the 156 keyboard has been changed so it fits better.
2. When reading back the keyboard from a Concerto or Qtouch-2 the text color conversion from 16
bit to 24 bit was wrong.

RELEASE 1.57
NEW FEATURES:

1. Version which uses OVERLAPPED RS232 communication in order to solve communication


problems with USB to SERIAL converters.

SOLVED PROBLEMS:
1. The automatic adjustment of columns in the report caused a problem with report which had
additional columns activated like the PLU reports when OPTION 203 was set.
RELEASE 1.58
NEW FEATURES:

1. Text# 1052 to 1062 are used now.


2. When using PLU scan codes and a new code is created when editing the PLU file QPROG will
automatically copy the PLU information from the active PLU when the new PLU is created and
keeps the focus on the scan code field. In this way it is possible to create the same PLU with
different scan codes. This could be useful when creating identical PLU but with different scan
code like for example electronic equipment (mobile phones) where each item has a different
code.

SOLVED PROBLEMS:
1. When a program wad loaded from disk and then it was installed in a register using the ethernet
LAN QPROG would sent it to the last IP address used instead of using the IP address as
programmed in the application.
2. Qprog didn't make a modem connection anymore. This was caused by the new overlapped
RS232 communication.

RELEASE 1.59
NEW FEATURES:

1. Text# 1063 is used now.


2. In the Keyboard Programming it is now possible to program the Fiscal Invoice Key with keycode
293.

RELEASE 1.60
NEW FEATURES:

1. Text# 1064 to 1073 are used now.


2. The “Communication” menu has been changed so the “Ethernet” options are now in the
“Communication-> Settings menu”.
3. The “Send To Register” menu has been changed. Now it is possible to send “Only File changes”
and “Only Program Files”. These options will only sent file (changes) and no SYSTEM (changes)
which are made in the SYSTEM menu. This can be useful when you have registers with different
parameters and options but have the same files.
4. The QPROG ICON has been changed.
5. In the “Configuration” menu it is now possible to select the “JPT 30T” model.
6. In the keyboard programming a new type of keyboard “Standard 40 Keys” has been added.
7. In the keyboard programming it is now possible to select 64K color key bitmaps for the Qtouch 44
and Qtouch 56 (64K color type) of keyboard. Note that this will only work with the Concerto and
Qtouch-2 model when release QC070406 or newer is installed.
8. In the “System->Parameters/Options” menu the tabs for “Qtouch + Concerto” have been moved
to the tab “POS”.
9. In the “System->Parameters/Options” menu the tabs “Receipt” and “Kitchen” printer now include
parameter 2 to 7.
10. In the “System->Parameters/Options” menu a new tab called “FILTER” has been added. This tab
can be used to filter parameter and options.

SOLVED PROBLEMS:

1. In the configuration menu QPROG will now check for a minimum of 1 Group instead of 0.
2. When in the CR1000 standard configuration menu 5000 tables were activated QPROG would
change the model to CR1000 restaurant and the number of tables to 100 when the configuration
menu was opened again.
RELEASE 1.61
NEW FEATURES:

1. Text# 1074 to 1078 are used now.


2. The number of SYSTEM OPTIONS has been increased to 384.

RELEASE 1.62
NEW FEATURES:

1. It is now possible to activate a special version of QPROG for fiscal markets. In TEXT# 46 you can
now program a version number which will automatically de activate certain functions. At the
moment you can specify 1 for Greece. Note that only digit 1 must be put in TEXT# 46 all other
values will activate the standard QPROG. This version will:
 Limit the Receipt Header and Trailer to maximum 3 lines.
 Limit the number of TAX selections to the activated number of taxes in the
configuration.
 Only Allow one tax selection for Department and/or PLU tax selection.
 Compulsory Tax selection for Department and/or PLU.
 Disable the Print Options in Department and/or PLU file editing.
 Disable the Options in Department and/or PLU editing.
 Disable the Options in the Clerk editing.
 Check for minimum 1 and maximum entry of Dept# and/or Group# in Dept and/or
PLU editing.

RELEASE 1.63
NEW FEATURES:

1. Text# 1079 to 1089 are used now.


2. In the Balance Configuration you can activate the storing of TIME and TIME LINK.
3. Two new FIXED keys for TIME IN (keycode 296) and TIME OUT (keycode 297) are added. They
are used for the PARKING and POOL TABLE time system.

RELEASE 1.64
NEW FEATURES:

1. Text# 1090 to 1092 are used now.


2. For the Fiscal markets QPROG will now display a Fiscal Error Code with the FILE name and
Record Number when uploading data to the reigster and it is not allowed to change certain
program parts. You can abort the transmission by the CANCEL button or continue with the next
record by clicking the OK button.
 Text# 1090, is displayed with the received error code.
 Text# 1091, is displayed when an Fiscal Z-report is required (Fiscal Error 4)
 Text# 1092, is displayed when this setting is not allowed (Fiscal Error 14)

SOLVED PROBLEMS:

1. The change made in version 1.62 for displaying options when editing file for the fiscal markets
caused that the activation of options in the User Report list were not displayed and changed.

RELEASE 1.65
NEW FEATURES:
1. Text# 1093 to 1094 are used now.
2. When in the PLU configuration CODE# SIZE is activated it is now possible to print labels when
EDITING the PLU file. In the popup menu which shows up with the right mouse click or when the
PROCESS button is pressed there is a new option “LABEL PRINTING” which can be used to
print the label for a range of selected PLU or for all PLU. The format of the printing is fixed and
the type of barcode used is CODE39 so don't forget to check if your scanner is set to accept
CODE39 codes and don't set SYSTEM OPTION 78 because the CODE39 has no check digit.
3. In order to avoid misunderstanding the option “External Logging” has been removed from PRINT
OPTION2 because this option has no use.

RELEASE 1.66

NEW FEATURES:

1. Text# 1095 to 1097 are used now.


2. It is now possible to only print labels for changed and/or created articles.
3. When editing a keyboard it possible to copy and paste a single key.

SOLVED PROBLEMS:

1. The size of the barcode printed on the label has been increased because some (Metrologic)
scanners were not able to read the printed code.
2. Importing the BALANCE limit field could be wrong when the limits had a different number of
digits.
3. When importing data it could happen that the last field was not imported when not all fields were
marked for importing.

RELEASE 1.67

SOLVED PROBLEMS:

1. A change in the configuration of the report construction caused that it was not possible to change
the report construction in the various files for the CR1000 series.

RELEASE 1.68

NEW FEATURES:

1. It is now possible to activate automatic Salesperson selection in the configuration of the Table,
Room and/or Account configuration.

RELEASE 1.69

NEW FEATURES:

1. Text# 544 is used now.


2. Text# 1098 to 1129 are used now.
3. The QPROG.DOC help file has been updated.

RELEASE 1.70

NEW FEATURES:

1. Text# 1130 is used now.


SOLVED PROBLEMS:

1. The wrong text was displayed for SYSTEM PARAMETER 126. (Quorilog Port#).
2. OVERLAPPED RS232 communication has been taken out because it created problems with
some USB to Serial convertors.

RELEASE 1.71

NEW FEATURES:

1. When a PLU report sorted by department is requested from a register with software release
XX071205 or newer installed QPROG will also diaply the department names.

RELEASE 1.72

NEW FEATURES:

1. Text# 1130 to 1143 are used now.


2. A new keyboard type for the Concerto and Qtouch-2 is available. It has 79 keys and a line which
displays the running total. You need QC080125 or newer installed in the register.

SOLVED PROBLEMS:

1. When an application was loaded from the History List or thruoght the command line the IP
address was not changed. Qprog would use the last used IP address.
2. Wrong text was displayed for OPTION 1.5 in Macro File editing.

RELEASE 1.73

NEW FEATURES:

1. Text# 1144 to 1162 are used now.

RELEASE 1.74

NEW FEATURES:

1. New LOGO SIZE of 576 x 90 for internal printer. Can be used with from register release 080516
or newer.
2. When a key on the keyboard has a USER DEFINED TEXT or a BITMAP it will NOT be reset to
default when the function of the key is changed. If you want to reset it to default you must select
“Reset to Default”.

SOLVED PROBLEMS:

1. When the FIRST & LAST Info was activated in the USER REPORT configuration it was not
possible to disable it again.

RELEASE 1.75

NEW FEATURES:

1. Text# 1163 to 1176 are used now.


2. Activation of Coupon In/Out file in Configuration for KLIER.
3. Activation of Report Journal in Configuration for KLIER.
RELEASE 1.76

NEW FEATURES:

1. Text# 1177 to 1202 are used now.


2. New type of keyboard with 94 keys for QPOS15.
3. Option in Communication->Settings->Thai Font. When set the QPROG will use the “MS Sans
Serif” font for Text and Keyboard editing. This font will also diaply Thai Characters.
4. Display Logo in Configuration General Settings activated for CR1000 series.
5. QCODE841126 activated for automatic generation of configuration files for production.
6. The SYSTEM OPTIONS windows has been increased to display 448 options.
4. Activation of FTP Report in Configuration for AMAX.

RELEASE 1.77

NEW FEATURES:

1. Text# 1203 to 1205 are used now.


2. Receipt Copy Buffer in Configuration requires 090130 or newer in register.
3. Store Scancodes in Clerk Interrupt Buffer Configuration.

SOLVED PROBLEMS:

1. Wrong text was displayed for OPTION 1.6 and 1.7 in Special Itemizer File editing.

RELEASE 1.78

NEW FEATURES:

1. Text# 1206 to 1209 are used now.

SOLVED PROBLEMS:

1. The text color when printing a keyboard was always set to black.
2. The format of the 94 key board for the QPOS15 was printed in the wrong format.

RELEASE 1.79s

NEW FEATURES:

1. Text# 1210 to 1212 are used now.


2. Search function in the translation menu.
3. Auto copy new texts in application when text set to all spaces.
4. Pop menu when editing texts to copy default text.
5. Set Country Configuration (Sweden).

RELEASE 1.79t

NEW FEATURES:

1. Text# 1213 to 1214 are used now.


2. Activation of extra fields in the FTP Report in Configuration for AMAX.

RELEASE 1.79v

NEW FEATURES:
1. Activation of FCU buffer when Country ID is set to Sweden.

RELEASE 1.79w

SOLVED PROBLEMS:

1. Country ID swapped for CR1000 models.

RELEASE 1.79x

NEW FEATURES:

1. Text# 1215 is used.


2. New Fixed function “KP Course” with keycode 299.
3. Text System Option 275 changed.
4. Changes made for Sweden. See SWEDEN_LOG.PDF for more info

RELEASE 1.79y

SOLVED PROBLEMS:

1. FTP report couldn't be activated in configuration.

RELEASE 1.79z

NEW FEATURES:

1. Text# 1216 & 1217are used.


2. Test version for new CR20 model.

RELEASE 1.79a

NEW FEATURES:

1. Text# 1218 is used.


2. New Fixed key “Overwrite Price” key code 298.

SOLVED PROBLEMS:

1. CR20 36 key was not stored correctly.

RELEASE 1.80

NEW FEATURES:

1. Help Window stays open until closed.


2. Changes made for Sweden.

SOLVED PROBLEMS:

1. Copy and Paste on 79 and 94 keyboard was not working.

RELEASE 1.81
(25-11-2009)

NEW FEATURES:
1. Text# 1218 to 1246 are used.
2. Maximum number of Tables, Rooms and Accounts can be set to 30000 instead of 10000.
3. CR20 configuration changed to version from “2X” to “20” needs G0091125 or newer..
4. Bitmaps are now automatically scaled to the key size and centered in the key.
5. The screen colors are now also saved when a keyboard is saved in a key file.

SOLVED PROBLEMS:

1. Printing of the CR20 keyboard was wrong.


2. When a key was changed and another keyboard level was selected without pressing OK the new
keyboard text was not sent correctly to the cash register. This only happens on registers with a
Touch screen.

RELEASE 1.8x
(xx-11-2009)

NEW FEATURES:

1. Text# 1218 to 1246 are used.

SOLVED PROBLEMS:

1. The right column of the Receipt Parameters TAB was displaying the wrong info.
2. The help reference in the configuration screen was pointing to the wrong section.
3. When changing to CR1XXX Restaurant the was no text displayed in the messagebox.

RELEASE 2.0
(11-02-2010)

NEW FEATURES:

1. Store Management is finally integrated


2. Text# 1249 to 1299 are used.
3. Saving three different keyboard layer for using on the CR20
4. The Flag 7 in Printer2 Option for balance function are set as “Fiscal Printer”

SOLVED PROBLEMS:

1. The help function shows the wrong information´s


2. All Options and Parameters are labeled and described

RELEASE 2.0.1
(18-03-2010)

NEW FEATURES:
1. By downloading a configuration from a cash register and overwrite a exist configuration, the old
configuration will be save into a backup folder (~tmp) in the directory where saving the
configuration.
2. Text# 1300 to 1309 are used

SOLVED PROBLEMS

1. CR1000 save the store management function now


2. The PLU list save the values again, by inactive store management function
3. Network consolidate for the store management is set as a default setting,
The network size must be set correct for using without failure, by one cash register must the size
set 0.

RELEASE 2.0.2 (Build 15)


(25-03-2010)

SOLVED PROBLEMS

1. Update of the store management works now correct by configured cash register network
The data will consolidate automatically by network connection
2. Update of the store management works again by directly cash register network
By using network connection and the cash register have no cash register id and network size
than fail the update of the store management (this is a correct behavior)

RELEASE 2.0.3 (Build 16)


(30-03-2010)

SOLVED PROBLEMS

1. Store Management, large PLU scan code greater than 12 Bit wasn´t update by the store
management, the routine for convert this large files was obsolete by the compiler now this works
currently with the right options.

RELEASE 2.0.4 (Build 28)


(24-06-2010)

NEW FEATURES:

1. Integrate new keyboard layout 104 horizontal standard and 117 horizontal flat
2. Changes model types into three different types
· CR 1000
· QMP 3000/5000
· QPrint
· CR20 has an exceptional position, cannot select by model type this feature is only
available by loading a configuration from disk or cash register.
3. Text# 1315 to 1323 are in use
4. OPTIONS 428, 429, 430, 431, 432 in use

SOLVED PROBLEMS

1. Update to the TProgressBar, because the TGauge was obsolete


2. Menu update fixed, if “Config” was changed the files menu entries wasn´t
updated.

RELEASE 2.0.6 (Build 31)


(24-06-2010)

SOLVED PROBLEMS

1. By uploading a wrong configuration into the CR2x-series occurs a fatal error, now before the
configuration load into the cash register, the model will be identify
2. Creating of Config ROM (crq-file) wasn´t enabled for CR2x-series, now it is as default activate

RELEASE 2.0.7
(02-08-2010)

NEW FEATURES

1. Proof Cashregister series CR1xxx by uploading configuration. It couldn´t


upload a CR1xxx configuration into another cash register model and a wrong configuration type
into the CR1xxx series.
2. Parameter/Options dialog changed. Handling for select options and
parameter is change for easier using with buttons and the filter function is now visible in all
tabulators. The filter function select the filter-tabulator automatically.

SOLVED PROBLEMS

1. QProg blocked any input by uploading huge files into the cashregister, a wrong memory handling
in a label could be the failure, this label was replace by a text edit.
2. The check routine for getting the cash register version occur a critical error by the Linux based
machine, the routine was improved. So the version 2.0.6 must be declared as obsolete.

RELEASE 2.0.8
(02-08-2010)

NEW FEATURES

1. PLU Linking works now by store management with QProg, too. The Inventory Amount means by
linking the unit size of the PLU to which it is linked.

SOLVED PROBLEMS

1. In the clerk configuration was an unused field which will show – solved by delete the command
for showing this field
2. Before checking the cash register the memory would delete before. The right way is now
checking cash register and if that’s okay before installing the application the memory will clear.

RELEASE 2.1.0
(04-10-2010)

NEW FEATURES

1. From this version it is possible, made the memory configuration for the CR2x model by the user.
· By changing the model type to CR2x model the keyboard layout will set on a default (this
is irreversible by click on okay button)
· Filter the Optionview for the CR2x model
2. Using Text from 1317 to 1354
3. OPTIONS 433, 434, 435, 436, 437, 438, 439, 440, 441, 442, 443, 444, 445, 446, 447 in use
4. PARAMETER 165, 166, 167, 168, 169 in use
5. Labeling of the Fileoptions are updated
6. The department number will show in the order and inventory report, now
SOLVED PROBLEMS

1. The default font size by set a keyboard button is now normal, because for better reading the key
function

RELEASE 2.1.1
(28-10-2010)

NEW FEATURES

1. Added Tender Info option in FTP Report File configuration.


2. Using Text from 1355 to 1358
3. OPTIONS 448 in use
4. PARAMETER 170 and 171 in use

SOLVED PROBLEMS

1. The window start position was fixed on a unsuitable desktop position. Now all windows will open
in the center of the screen.
2. Parameter/Options windows size of the parameter columns was fixed on the windows start - the
visible range of the column was not nice because longer text couldn´t read good. - Now fixed by
changing windows size the columns size are change again and the start size of the window is
higher.

RELEASE 2.1.2
(04-11-2010)

NEW FEATURES

1. Added Card Table in Configuration and Files.


2. Using Text 1359, 1360, 1361
3. OPTIONS 449 and 450 in use
4. Saving scan code will activate automatically by using scan code and binary eJournal
5. Saving settings of QProg with the cash register configuration (new file QST), so the IP
configuration and QProg specific setting will saved by the configuration of the cash register and
load automatically when file exist in the cash register configuration.

SOLVED PROBLEMS

1. In Order report was the data of departments column was not include, fixed.
2. Printing new keyboard layouts was wrong, fixed by printing in the landscape mode

RELEASE 2.1.3
(04-11-2010)

SOLVED PROBLEMS

1. Saving of the WAN IP address going wrong by loading a cr config after a other one loading.
RELEASE 2.1.4
(10-01-2011)

NEW FEATURES

1. Using Text 1362 – 1365


2. Options 451 (Store Receipt# with Order) and 452 (Table Name on Table MAP) in use
3. Parameter 172 (Columns in Balance Menu´s) in use

SOLVED PROBLEMS

1. Quantity Amount in the store management wouldn´t show in red if the value is below the
minimum amount – FIXED
2. By canceling of PLU setting the store management function was not included, now the
start values will be set by canceling

RELEASE 2.1.5
(03-02-2011)

NEW FEATURES

1. Using Text 1366 – 1372


2. Option in use:
453: Round Quantity to max 5 decimals
454: Round Subtotal Invoice
455: Receipt with Balance Correction
456: Age Control at Payment
3. Parameter 173 (Room Charge Tender Function#) and 174 (Reset SalesPerson#) in use
4. Spezial Itemizer Option 2.1 in use (Use Clerk Commission Rate)

SOLVED PROBLEMS

1. Printing of the keyboard type 13 (117 key flat) was in the wrong scaling format (fixed)
2. Revert features which lost by assumption of QProg Version 1.81
a. Maximal values for tables, room and account totals (QMP 3000)
b. Country selection was wrong by selecting Sweden version
3. Store management creates a wrong entry by cost price if the configuration is loading
from the cash register on the same location where the store management configuration is
save. (fixed)

RELEASE 2.1.6
(02-03-2011)

NEW FEATURES

1. Using Text 1373


2. Option in use: 457: Graphic Logo Slip Only
3. Parameter 166 Update Help Text
4. Export File as TXT file in the setting tables (that mean that the file have the extention “txt” but it is
a csv file – you can use the txt extention for import a csv file in Excel by using the import wizard)
5. Using Text 1374 and Option 438 – CR20 always on

SOLVED PROBLEMS
1. Changing in the Parameter/Option Dialog wouldn´t assumed by switching the parameter
and option view – now solved.
2. Communication with customer id going wrong, the entry of the correct password wouldn
´t accepts by loading new setting in the cash register – solved.

RELEASE 2.1.7
(07-04-2011)

NEW FEATURES

1. add 576x90 resolution in the general settings for the second graphic logo
2. Using Systemtext (RELEASE QC110307 - QC110327)
- 1375 - Room Text use for Address Entry
- 1376 - Use Handheld Printer 2
- 1377 - Handheld Receipt Printer Type 2
- 1378 - Handheld Receipt Printer Port 2
- 1379 - Instore Code Weight Check
- 1380 - No Average Cover Print
- 1381 - Weight Confirmation
- 1382 - Toggle PLU Name 2 in Menu
- 1383 - Weight Comparision No MGR Control
- 1384 - Scale Retry count
- 1385 - Time Executed Macro #2
- 1386 - Autmatic Copy-Print of Invoice
- 1387 - Label printing repetitions:
- 1388 - Repetitions and scaling of one label
- 1389 - Scalingfactor in Percent:
- 1390 - Set default load config file
- 1391 - Activate automatic startup load
- 1392 - Set Config File
- 1393 - Configfile is invalid
- 1394 - Default Loading
3. Integrate new Systemstextes by Jan – definitions
4. By printing of PLU labels now it is possible to change the number of printing of one
label and the scalingrate between 25% - 100%
5. It is possible to define a standard loading CR configuration which load automatically by
start of QProg

SOLVED PROBLEMS

1. Count of Dataset made some problems by communication in the communication dialog by hiding
this element, now it will shown always
2. Report format view revised: grouping of information going wrong if the total sales line was not
integratet, so the entries will following immediately. Now will check if the totals in the report are
without a total sales lines and integrate them before the total entries.
RELEASE 2.1.8
(04-05-2011)

NEW FEATURES

1. Using System Text (Release 110404 – 110426)


- 1395 Consolidate Inventory in Network
- 1396 Active Clerk in Table Menu
- 1397 Show All Rooms and Accounts
- 1398 Reserved
- 1399 Print Adjustment
- 1400 Adjustment Height (mm)
- 1401 Adjustment Width (mm)

2. Printing Adjustment for Labelprint


- In the label repeat and scaling dialog can define adjustment for the x and y axis
- The adjustment can have between -50 to 50 mm

SOLVED PROBLEMS

1. Values in the parameter and options dialog was lost by resizing the window – solved!

RELEASE 2.1.9
(09-06-2011)

NEW FEATURES

1. Add filter function for the files view, so can filter the entries about the caption columns
2. Update the help document
3. Using System Text 1402 Balance Text on KP Large Font

SOLVED PROBLEMS

1. Before printing the PLU list was showing a wrong dialog – fixed.

RELEASE 2.1.10
(05-07-2011)

NEW FEATURES

1. If the report journal is activate in the cash register, now it is possible to read this report with
QProg. Therefore you must select in the menu “Reporting” and push the menu item “Get Report”.
In the dropdown list you can find the entry “199 – Report Journal”. For viewing this kind of report
you have to select only the file with the menu item “View Report”.

RELEASE 2.1.11
(03-08-2011)

NEW FEATURES

1. Using System Text 1403 “Combine Articles from KP#” and update Help File
RELEASE 2.1.12
(25-09-2011)

NEW FEATURES

1. By creating a new PLU with scan code and you enter the new scan code in a field of a exist PLU
you can decide if you want copy all entries of this PLU or create a new one without informations.

SOLVED PROBLEMS

1. The printing size and the printing crop marks was wrong for the keyboard type 117 flat keys – is
fixed.

RELEASE 2.1.13
(04-10-2011)

NEW FEATURES

1. Using System Text 1404 “Suppress Total with Line Find”

SOLVED PROBLEMS

1. Fixing missing crop marks by different keyboard types

RELEASE 2.2.0
(01-12-2011)

NEW FEATURES

1. Using Texts for Options 469 – 474


2. Using Texts for Parameter 181, 182

First Version with integration for QTouch10


1. Adding new keyboard types QTouch10 64Keys, 76Keys and 101 Keys
2. New function programmable MODE selection
3. Communication selection by sending or reading configuration
4. New logo handling, now it is possible to resize the logo in QProg and select two different
converting methods for generate a monochrome logo (monochrome by threshold selection and
dithering method)
5. All loadable images can be a JPEG format now
6. In System menu is now integrate a simple device manager for set typically device configuration
on a cash register

SOLVED PROBLEMS
1. Italy configuraiton for departments was wrong - change the maximal number to 99 for Italy
2. Dialog for edit the programming texts had a fixed size - now it can resize for better searching and
so on
3. Store management handling with scan code plu´s going wrong, was a error by identify the correct
plu status and position
4. The initial bitmap by start of QProg will become a transparence color for the background
RELEASE 2.2.1
(05-01-2012)

NEW FEATURES
1. add using Text 1440 "Store Internal SD E-Journal" for using Option 472

SOLVED PROBLEMS
1. Correct any clerical error
2. The text “show only set values” couldn´t translate – fixed
3. color picking dialog will show now expand and get the actual color of the selected grid button
4. enable cost value by using store managment in the PLU configuration is not possible at the same
time - because the cost value will not calculation correct in this case

NOTE:
In any cases the new connection dialog “Interface Setting” caused a time problem, you can solve this by
delete the translastion text for “Interface Setting”, then the dialog will not show any more before
communication.

RELEASE 2.2.2
(07-02-2012)

NEW FEATURES
1. If the Parameter 174 (Salesperson) is set on 255, then will be set this parameter by sending to the
cash register get the value of the cr number (Parameter 53). By sending the configuration in a cash
register network, the value will be increase like the cr number, too.

SOLVED PROBLEMS
1. The communication via WAN (DynDNS) doesn´t work with the new communication dialog, the
problem was solved by avaluation the flags in the right way.
2. Any textes in the configuration panel would hide although the texts exist in the translation file. The
reason was that the texts had the wrong checking reference for hinding. – solved
3. For the 128 keyboard the the crop marker was lost, by the last update. Now they will print again.
4. The function key for programming mode can be reprogrammed on all keyboard level, then the
key will get the value of the last programming, but the value on the other keyboard level was not
showing in the correct way. Now it will be show on all level which value the function key has.
5. Keyboard Type 128 and 156 Flat couldn´t load and print any bitmaps on the keys now it is
possible again
6. Sometimes QProg interrupt with an out of memory error in the PLU programming. The problem
couln´t exact analyze but the memory handling by the handling with the PLU data has been
revised. That should bring an improvement.
7. The handling with the keyboard-level for the QRC file generating has been revised.

RELEASE 2.2.3
(20-02-2012)

NEW FEATURES
1. Now it is possible to enable/disable the scanning function for the serial port, therefore you can
find a checkbox by the serial port combo box.
2. Using text
1441 – “Automatic scan”
1442 – “Reserved Swedish BOXEN”
1443 – “Font A characters per line”
1444 – “Font B characters per line”
1445 – “Logo width per pixels/8
1446 – “Only Table Start Time”
SOLVED PROBLEMS
1. The backup routines are new implemented, because the using windows routines don´t works
correct.
2. The device manager set the internal printer to zero, although they don´t use a external serial port.
This is fixed, internal printer keep their settings.
3. Handling of the keyboard-level going wrong, so it is fixed on the 36 key type only. For the other
keyboard types it will handle on the old way.