TDS100F Ultrasonic Fixed Flowmeter

Applications:
The TDS100F is an ideal choice for long-term deploy-
ment for flow measurement and closed-pipe applica-
tions such as

• Liquid process control

• Water flow measurement (hot/chill water, city


water, sea water)

• Sewage and sludge measurement

• Measurement of oil (crude/diesel/fuel), chemicals


(alcohol, acids, etc.), beverages, and many other
liquids

Features:

• Suitable for all commonly used pipe materials

• Wide flow range: 0.01 to 32 m/s

• Velocity, volumetric & totalized flow

• Wide pipe range: 25 mm to 6000 mm

• High accuracy ± 1% and on-site calibration can


reduce this to ± 0.5%

• Large savings in labour installation costs

Advantages:
• No pressure drop

• No moving parts

• No risk of contamination or corrosion

• No flanges required or pipes to be cut and welded


Specifications:

Accuracy Better than ± 1%


Response Time 0.5s
Velocity ± 0.01 to 32 m/s
Display LCD with backlight
2 x 20 Characters
Displays instantaneous flow rate, accumulated flow rate (positive, negative, and net totals), velocity, time,
analogue inputs, etc.
Units English metric
Signal Outputs Current output: 4—20mA or 0—20mA, Impedance 0—1k, accuracy 0.1%

OCT output: pulse signal for accumulated flow rate; frequency signal for instantaneous flow rate

Relay: able to output 20 signals e.g. no signal, reverse flow, etc.


Sound alarm
Signal Inputs 5-channel analogue signal inputs (temperature, pressure, liquid level, etc.)
Recording Automatically records the following:
• The data of the 64 days/64 months/64 years
• The power time and corresponding flow rate of the last 64 times
• Power on and off events
• Manual or automatic flow loss compensation
• The instrument’s working status of the last 64 days
Communication RS-232, RS-485 (optional)
Liquid Types Virtually all commonly used liquids (full pipe)
Liquid Temp 0°C to 100 °C PLEASE NOTE: If over 80°C, please choose high temp sensor
Pipe Size 25 mm to 6000 mm
Pipe Material All metals, plastics, fiberglass, etc. Allow pipe liner.
Pipe Straight Better longer than 15D (D = pipe diameter). If a pump is near, the straight pipe section following the
Section Length pumps should be more than 30D.
Cable Shielded transducer cable, standard length 5 m. Max extended length 500 m.
Temperature Main unit: -30°C to 80°C
Transducer: -40°C to 100°C
Humidity Main unit: 85% RH
Transducer: water-immersion, water depth less than 3 m
Power AC: 110 V/220 V or DC: 8 VDC—36 VDC
Weight 2.5 kg

Cape Instrument Services (Tel) 021 511 4101 (Email) sales@cis-online.co.za (Web) www.cis-online.co.za