Sie sind auf Seite 1von 47

Produced on 14/10/2019 with Xpress Selection V8.6.5 - database DIL 13.8.

Project name CLINICA IOM


Project address Peru
Reference LIMA
Client name ING. EDMUNDO GARCIA
Revision GCM_01

Selection parameters of the indoor units can be found under the chapter Indoor unit details
Selection parameters of the outdoor units can be found under the chapter Outdoor unit details
Only the data published in the data book are correct. This program uses close approximations of these data.

1. Material List
Model Qty Description
RXQ12TATL 5 Cooling only VRV IV(TATL)
RXQ16TATL 1 Cooling only VRV IV(TATL)
RXQ18TATL 3 Cooling only VRV IV(TATL)
RXQ8TATL 1 Cooling only VRV IV(TATL)
FXMQ20PAVE 17 VRV M-PA - Unidad de conducto montada en el techo
FXMQ25PAVE 20 VRV M-PA - Unidad de conducto montada en el techo
FXMQ32PAVE 37 VRV M-PA - Unidad de conducto montada en el techo
FXMQ40PAVE 9 VRV M-PA - Unidad de conducto montada en el techo
FXMQ50PAVE 8 VRV M-PA - Unidad de conducto montada en el techo
FXMQ63PAVE 15 VRV M-PA - Unidad de conducto montada en el techo
FXMQ80PAVE 7 VRV M-PA - Unidad de conducto montada en el techo
KHRP26A22T 63 Refnet branch piping kit
KHRP26A33T 12 Refnet branch piping kit
KHRP26A72T 28 Refnet branch piping kit
KHRP26A73T + KHRP26M73TP 5 Refnet branch piping kit
BRC1E63 113 Wired Remote Controller (Navigation Remote Controller)
BHFP22P100 5 Outdoor unit multi connection piping kit
R410A 86.6kg Extra refrigerant charge
Piping ¼" 302.3m
Piping ⅜" 262.8m
Piping ½" 350.6m
Piping ⅝" 250.2m
Piping ¾" 169.2m
Piping ⅞" 35.4m
Piping 1⅛" 74.3m
Piping 1⅜" 166.0m

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 1
2. Indoor Unit Details
2.1. Table of Abbreviations
Name Logical name of the device
FCU Device model name
Tmp C Indoor conditions in cooling (dry bulb temp. / wet bulb temp.)
Rq TC Required total cooling capacity
Max TC Available total cooling capacity
Rq SC Required sensible cooling capacity
Max SC Available sensible cooling capacity
Tevap Evaporating temperature of indoor unit coil
Tdis C Indoor unit discharge air temperature in cooling
Airflow Supplied airflow
Sound Sound pressure low and high
PS Power supply (voltage and phases)
MCA Minimum Circuit Amps
WxHxD WidthxHeightxDepth
Wght Weight of the device

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 2
2.2. VRV - PISO 4 - RXQ30TATL
Capacity data at conditions and connection ratio (122%) as entered
Name FCU Tmp C Rq TC Max TC Rq SC Max SC Tevap Tdis C Airflow
°C BTU/h BTU/h BTU/h BTU/h °C °C cfm
UE 4-21 FXMQ50PAVE 24.0 / 17.0 n/a 18426 n/a 15914 Auto 11.4 636
UE 4-24 FXMQ20PAVE 24.0 / 17.0 n/a 7336 n/a 6739 Auto 13.3 318
UE 4-22 FXMQ80PAVE 24.0 / 17.0 n/a 29515 n/a 23691 Auto 10.5 883
UE 4-23 FXMQ80PAVE 24.0 / 17.0 n/a 29515 n/a 23691 Auto 10.5 883
UE 4-1 FXMQ63PAVE 24.0 / 17.0 n/a 23373 n/a 18603 Auto 10.4 689
UE 4-2 FXMQ25PAVE 24.0 / 17.0 n/a 9213 n/a 7879 Auto 11.5 318
UE 4-10 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE 4-3 FXMQ40PAVE 24.0 / 17.0 n/a 14672 n/a 13437 Auto 12.0 565
UE 4-4 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE 4-11 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE 4-5 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE 4-6 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE 4-17 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE 4-14 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE 4-12 FXMQ25PAVE 24.0 / 17.0 n/a 9213 n/a 7879 Auto 11.5 318
UE 4-7 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE 4-8 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE 4-13 FXMQ25PAVE 24.0 / 17.0 n/a 9213 n/a 7879 Auto 11.5 318
UE 4-9 FXMQ40PAVE 24.0 / 17.0 n/a 14672 n/a 13437 Auto 12.0 565
UE 4-16 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE 4-20 FXMQ20PAVE 24.0 / 17.0 n/a 7336 n/a 6739 Auto 13.3 318
UE 4-15 FXMQ40PAVE 24.0 / 17.0 n/a 14672 n/a 13437 Auto 12.0 565
UE 4-19 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE 4-18 FXMQ63PAVE 24.0 / 17.0 n/a 23373 n/a 18603 Auto 10.4 689

Required cooling capacity towards the outdoor unit: 340020BTU/h.

The calculation shows the peak discharge temperatures (lowest temperature in case of cooling mode / highest
temperature in case of heating mode), assuming the indoor unit is running at full load at the given indoor
temperature design conditions. In practice the discharge temperature will modulate based on actual capacity
requirements and during defrost mode (heating mode).
The analysis of the suction and discharge temperature values may help in preventing a cold draft and to ensure a
thermal comfort level.

Name Sound PS MCA WxHxD Wght


dBA A mm kg
UE 4-21 37-41 220V 1ph 1.6 1000×300×700 35
UE 4-24 29-33 220V 1ph 0.6 550×300×700 25
UE 4-22 39-43 220V 1ph 2.3 1000×300×700 35
UE 4-23 39-43 220V 1ph 2.3 1000×300×700 35
UE 4-1 38-42 220V 1ph 1.8 1000×300×700 35
UE 4-2 28-33 220V 1ph 0.6 550×300×700 25
UE 4-10 30-34 220V 1ph 0.6 550×300×700 25
UE 4-3 35-39 220V 1ph 1.4 700×300×700 27
UE 4-4 30-34 220V 1ph 0.6 550×300×700 25
UE 4-11 30-34 220V 1ph 0.6 550×300×700 25
UE 4-5 30-34 220V 1ph 0.6 550×300×700 25
UE 4-6 30-34 220V 1ph 0.6 550×300×700 25
UE 4-17 30-34 220V 1ph 0.6 550×300×700 25

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 3
Name Sound PS MCA WxHxD Wght
dBA A mm kg
UE 4-14 30-34 220V 1ph 0.6 550×300×700 25
UE 4-12 28-33 220V 1ph 0.6 550×300×700 25
UE 4-7 30-34 220V 1ph 0.6 550×300×700 25
UE 4-8 30-34 220V 1ph 0.6 550×300×700 25
UE 4-13 28-33 220V 1ph 0.6 550×300×700 25
UE 4-9 35-39 220V 1ph 1.4 700×300×700 27
UE 4-16 30-34 220V 1ph 0.6 550×300×700 25
UE 4-20 29-33 220V 1ph 0.6 550×300×700 25
UE 4-15 35-39 220V 1ph 1.4 700×300×700 27
UE 4-19 30-34 220V 1ph 0.6 550×300×700 25
UE 4-18 38-42 220V 1ph 1.8 1000×300×700 35

Outdoor unit placed at the same level as the indoor units.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 4
2.3. VRV - PISO 3 - RXQ30TATL
Capacity data at conditions and connection ratio (122%) as entered
Name FCU Tmp C Rq TC Max TC Rq SC Max SC Tevap Tdis C Airflow
°C BTU/h BTU/h BTU/h BTU/h °C °C cfm
UE 3-21 FXMQ50PAVE 24.0 / 17.0 n/a 18426 n/a 15914 Auto 11.4 636
UE 3-24 FXMQ20PAVE 24.0 / 17.0 n/a 7336 n/a 6739 Auto 13.3 318
UE 3-22 FXMQ80PAVE 24.0 / 17.0 n/a 29515 n/a 23691 Auto 10.5 883
UE 3-23 FXMQ80PAVE 24.0 / 17.0 n/a 29515 n/a 23691 Auto 10.5 883
UE 3-1 FXMQ63PAVE 24.0 / 17.0 n/a 23373 n/a 18603 Auto 10.4 689
UE 3-2 FXMQ25PAVE 24.0 / 17.0 n/a 9213 n/a 7879 Auto 11.5 318
UE 3-10 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE 3-3 FXMQ40PAVE 24.0 / 17.0 n/a 14672 n/a 13437 Auto 12.0 565
UE 3-4 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE 3-11 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE 3-5 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE 3-6 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE 3-17 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE 3-14 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE 3-12 FXMQ25PAVE 24.0 / 17.0 n/a 9213 n/a 7879 Auto 11.5 318
UE 3-7 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE 3-8 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE 3-13 FXMQ25PAVE 24.0 / 17.0 n/a 9213 n/a 7879 Auto 11.5 318
UE 3-9 FXMQ40PAVE 24.0 / 17.0 n/a 14672 n/a 13437 Auto 12.0 565
UE 3-16 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE 3-20 FXMQ20PAVE 24.0 / 17.0 n/a 7336 n/a 6739 Auto 13.3 318
UE 3-15 FXMQ40PAVE 24.0 / 17.0 n/a 14672 n/a 13437 Auto 12.0 565
UE 3-19 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE 3-18 FXMQ63PAVE 24.0 / 17.0 n/a 23373 n/a 18603 Auto 10.4 689

Required cooling capacity towards the outdoor unit: 340020BTU/h.

The calculation shows the peak discharge temperatures (lowest temperature in case of cooling mode / highest
temperature in case of heating mode), assuming the indoor unit is running at full load at the given indoor
temperature design conditions. In practice the discharge temperature will modulate based on actual capacity
requirements and during defrost mode (heating mode).
The analysis of the suction and discharge temperature values may help in preventing a cold draft and to ensure a
thermal comfort level.

Name Sound PS MCA WxHxD Wght


dBA A mm kg
UE 3-21 37-41 220V 1ph 1.6 1000×300×700 35
UE 3-24 29-33 220V 1ph 0.6 550×300×700 25
UE 3-22 39-43 220V 1ph 2.3 1000×300×700 35
UE 3-23 39-43 220V 1ph 2.3 1000×300×700 35
UE 3-1 38-42 220V 1ph 1.8 1000×300×700 35
UE 3-2 28-33 220V 1ph 0.6 550×300×700 25
UE 3-10 30-34 220V 1ph 0.6 550×300×700 25
UE 3-3 35-39 220V 1ph 1.4 700×300×700 27
UE 3-4 30-34 220V 1ph 0.6 550×300×700 25
UE 3-11 30-34 220V 1ph 0.6 550×300×700 25
UE 3-5 30-34 220V 1ph 0.6 550×300×700 25
UE 3-6 30-34 220V 1ph 0.6 550×300×700 25
UE 3-17 30-34 220V 1ph 0.6 550×300×700 25

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 5
Name Sound PS MCA WxHxD Wght
dBA A mm kg
UE 3-14 30-34 220V 1ph 0.6 550×300×700 25
UE 3-12 28-33 220V 1ph 0.6 550×300×700 25
UE 3-7 30-34 220V 1ph 0.6 550×300×700 25
UE 3-8 30-34 220V 1ph 0.6 550×300×700 25
UE 3-13 28-33 220V 1ph 0.6 550×300×700 25
UE 3-9 35-39 220V 1ph 1.4 700×300×700 27
UE 3-16 30-34 220V 1ph 0.6 550×300×700 25
UE 3-20 29-33 220V 1ph 0.6 550×300×700 25
UE 3-15 35-39 220V 1ph 1.4 700×300×700 27
UE 3-19 30-34 220V 1ph 0.6 550×300×700 25
UE 3-18 38-42 220V 1ph 1.8 1000×300×700 35

Outdoor unit placed at the same level as the indoor units.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 6
2.4. VRV - PISO 2 - RXQ28TATL
Capacity data at conditions and connection ratio (123%) as entered
Name FCU Tmp C Rq TC Max TC Rq SC Max SC Tevap Tdis C Airflow
°C BTU/h BTU/h BTU/h BTU/h °C °C cfm
UE 2-18 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE 2-25 FXMQ20PAVE 24.0 / 17.0 n/a 7336 n/a 6739 Auto 13.3 318
UE 2-22 FXMQ40PAVE 24.0 / 17.0 n/a 14672 n/a 13437 Auto 12.0 565
UE 2-23 FXMQ80PAVE 24.0 / 17.0 n/a 29515 n/a 23691 Auto 10.5 883
UE 2-24 FXMQ80PAVE 24.0 / 17.0 n/a 29515 n/a 23691 Auto 10.5 883
UE 2-1 FXMQ50PAVE 24.0 / 17.0 n/a 18426 n/a 15914 Auto 11.4 636
UE 2-2 FXMQ20PAVE 24.0 / 17.0 n/a 7336 n/a 6739 Auto 13.3 318
UE 2-10 FXMQ25PAVE 24.0 / 17.0 n/a 9213 n/a 7879 Auto 11.5 318
UE 2-3 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE 2-4 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE 2-11 FXMQ25PAVE 24.0 / 17.0 n/a 9213 n/a 7879 Auto 11.5 318
UE 2-5 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE 2-6 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE 2-12 FXMQ25PAVE 24.0 / 17.0 n/a 9213 n/a 7879 Auto 11.5 318
UE 2-14 FXMQ25PAVE 24.0 / 17.0 n/a 9213 n/a 7879 Auto 11.5 318
UE 2-15 FXMQ20PAVE 24.0 / 17.0 n/a 7336 n/a 6739 Auto 13.3 318
UE 2-13 FXMQ25PAVE 24.0 / 17.0 n/a 9213 n/a 7879 Auto 11.5 318
UE 2-7 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE 2-8 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE 2-9 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE 2-21 FXMQ20PAVE 24.0 / 17.0 n/a 7336 n/a 6739 Auto 13.3 318
UE 2-16 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE 2-17 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE 2-20 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE 2-19 FXMQ63PAVE 24.0 / 17.0 n/a 23373 n/a 18603 Auto 10.4 689

Required cooling capacity towards the outdoor unit: 320401BTU/h.

The calculation shows the peak discharge temperatures (lowest temperature in case of cooling mode / highest
temperature in case of heating mode), assuming the indoor unit is running at full load at the given indoor
temperature design conditions. In practice the discharge temperature will modulate based on actual capacity
requirements and during defrost mode (heating mode).
The analysis of the suction and discharge temperature values may help in preventing a cold draft and to ensure a
thermal comfort level.

Name Sound PS MCA WxHxD Wght


dBA A mm kg
UE 2-18 30-34 220V 1ph 0.6 550×300×700 25
UE 2-25 29-33 220V 1ph 0.6 550×300×700 25
UE 2-22 35-39 220V 1ph 1.4 700×300×700 27
UE 2-23 39-43 220V 1ph 2.3 1000×300×700 35
UE 2-24 39-43 220V 1ph 2.3 1000×300×700 35
UE 2-1 37-41 220V 1ph 1.6 1000×300×700 35
UE 2-2 29-33 220V 1ph 0.6 550×300×700 25
UE 2-10 28-33 220V 1ph 0.6 550×300×700 25
UE 2-3 30-34 220V 1ph 0.6 550×300×700 25
UE 2-4 30-34 220V 1ph 0.6 550×300×700 25
UE 2-11 28-33 220V 1ph 0.6 550×300×700 25
UE 2-5 30-34 220V 1ph 0.6 550×300×700 25

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 7
Name Sound PS MCA WxHxD Wght
dBA A mm kg
UE 2-6 30-34 220V 1ph 0.6 550×300×700 25
UE 2-12 28-33 220V 1ph 0.6 550×300×700 25
UE 2-14 28-33 220V 1ph 0.6 550×300×700 25
UE 2-15 29-33 220V 1ph 0.6 550×300×700 25
UE 2-13 28-33 220V 1ph 0.6 550×300×700 25
UE 2-7 30-34 220V 1ph 0.6 550×300×700 25
UE 2-8 30-34 220V 1ph 0.6 550×300×700 25
UE 2-9 30-34 220V 1ph 0.6 550×300×700 25
UE 2-21 29-33 220V 1ph 0.6 550×300×700 25
UE 2-16 30-34 220V 1ph 0.6 550×300×700 25
UE 2-17 30-34 220V 1ph 0.6 550×300×700 25
UE 2-20 30-34 220V 1ph 0.6 550×300×700 25
UE 2-19 38-42 220V 1ph 1.8 1000×300×700 35

Outdoor unit placed at the same level as the indoor units.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 8
2.5. VRV - PISO 1 - RXQ26TATL
Capacity data at conditions and connection ratio (123%) as entered
Name FCU Tmp C Rq TC Max TC Rq SC Max SC Tevap Tdis C Airflow
°C BTU/h BTU/h BTU/h BTU/h °C °C cfm
UE 1-17 FXMQ50PAVE 24.0 / 17.0 n/a 18426 n/a 15914 Auto 11.4 636
UE 1-18 FXMQ80PAVE 24.0 / 17.0 n/a 29515 n/a 23691 Auto 10.5 883
UE 1-1 FXMQ50PAVE 24.0 / 17.0 n/a 18426 n/a 15914 Auto 11.4 636
UE 1-12 FXMQ25PAVE 24.0 / 17.0 n/a 9213 n/a 7879 Auto 11.5 318
UE 1-6 FXMQ63PAVE 24.0 / 17.0 n/a 23373 n/a 18603 Auto 10.4 689
UE 1-3 FXMQ63PAVE 24.0 / 17.0 n/a 23373 n/a 18603 Auto 10.4 689
UE 1-5 FXMQ63PAVE 24.0 / 17.0 n/a 23373 n/a 18603 Auto 10.4 689
UE 1-4 FXMQ63PAVE 24.0 / 17.0 n/a 23373 n/a 18603 Auto 10.4 689
UE 1-16 FXMQ20PAVE 24.0 / 17.0 n/a 7336 n/a 6739 Auto 13.3 318
UE 1-9 FXMQ40PAVE 24.0 / 17.0 n/a 14672 n/a 13437 Auto 12.0 565
UE 1-10 FXMQ63PAVE 24.0 / 17.0 n/a 23373 n/a 18603 Auto 10.4 689
UE 1-11 FXMQ63PAVE 24.0 / 17.0 n/a 23373 n/a 18603 Auto 10.4 689
UE 1-12 FXMQ63PAVE 24.0 / 17.0 n/a 23373 n/a 18603 Auto 10.4 689
UE 1-13 FXMQ20PAVE 24.0 / 17.0 n/a 7336 n/a 6739 Auto 13.3 318
UE 1-8 FXMQ20PAVE 24.0 / 17.0 n/a 7336 n/a 6739 Auto 13.3 318
UE 1-7 FXMQ20PAVE 24.0 / 17.0 n/a 7336 n/a 6739 Auto 13.3 318
UE 1-14 FXMQ20PAVE 24.0 / 17.0 n/a 7336 n/a 6739 Auto 13.3 318
UE 1-15 FXMQ20PAVE 24.0 / 17.0 n/a 7336 n/a 6739 Auto 13.3 318

Required cooling capacity towards the outdoor unit: 297880BTU/h.

The calculation shows the peak discharge temperatures (lowest temperature in case of cooling mode / highest
temperature in case of heating mode), assuming the indoor unit is running at full load at the given indoor
temperature design conditions. In practice the discharge temperature will modulate based on actual capacity
requirements and during defrost mode (heating mode).
The analysis of the suction and discharge temperature values may help in preventing a cold draft and to ensure a
thermal comfort level.

Name Sound PS MCA WxHxD Wght


dBA A mm kg
UE 1-17 37-41 220V 1ph 1.6 1000×300×700 35
UE 1-18 39-43 220V 1ph 2.3 1000×300×700 35
UE 1-1 37-41 220V 1ph 1.6 1000×300×700 35
UE 1-12 28-33 220V 1ph 0.6 550×300×700 25
UE 1-6 38-42 220V 1ph 1.8 1000×300×700 35
UE 1-3 38-42 220V 1ph 1.8 1000×300×700 35
UE 1-5 38-42 220V 1ph 1.8 1000×300×700 35
UE 1-4 38-42 220V 1ph 1.8 1000×300×700 35
UE 1-16 29-33 220V 1ph 0.6 550×300×700 25
UE 1-9 35-39 220V 1ph 1.4 700×300×700 27
UE 1-10 38-42 220V 1ph 1.8 1000×300×700 35
UE 1-11 38-42 220V 1ph 1.8 1000×300×700 35
UE 1-12 38-42 220V 1ph 1.8 1000×300×700 35
UE 1-13 29-33 220V 1ph 0.6 550×300×700 25
UE 1-8 29-33 220V 1ph 0.6 550×300×700 25
UE 1-7 29-33 220V 1ph 0.6 550×300×700 25
UE 1-14 29-33 220V 1ph 0.6 550×300×700 25
UE 1-15 29-33 220V 1ph 0.6 550×300×700 25

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 9
Outdoor unit placed at the same level as the indoor units.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 10
2.6. VRV - SOTANO - RXQ24TATL
Capacity data at conditions and connection ratio (127%) as entered
Name FCU Tmp C Rq TC Max TC Rq SC Max SC Tevap Tdis C Airflow
°C BTU/h BTU/h BTU/h BTU/h °C °C cfm
UE S-20 FXMQ25PAVE 24.0 / 17.0 n/a 9213 n/a 7879 Auto 11.5 318
UE S-21 FXMQ20PAVE 24.0 / 17.0 n/a 7336 n/a 6739 Auto 13.3 318
UE S-22 FXMQ25PAVE 24.0 / 17.0 n/a 9213 n/a 7879 Auto 11.5 318
UE S-2 FXMQ63PAVE 24.0 / 17.0 n/a 23373 n/a 18603 Auto 10.4 689
UE S-3 FXMQ63PAVE 24.0 / 17.0 n/a 23373 n/a 18603 Auto 10.4 689
UE S-1 FXMQ20PAVE 24.0 / 17.0 n/a 7336 n/a 6739 Auto 13.3 318
UE S-5 FXMQ20PAVE 24.0 / 17.0 n/a 7336 n/a 6739 Auto 13.3 318
UE S-4 FXMQ63PAVE 24.0 / 17.0 n/a 23373 n/a 18603 Auto 10.4 689
UE S-9 FXMQ25PAVE 24.0 / 17.0 n/a 9213 n/a 7879 Auto 11.5 318
UE S-6 FXMQ50PAVE 24.0 / 17.0 n/a 18426 n/a 15914 Auto 11.4 636
UE S-19 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE S-18 FXMQ25PAVE 24.0 / 17.0 n/a 9213 n/a 7879 Auto 11.5 318
UE S-12 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE S-13 FXMQ40PAVE 24.0 / 17.0 n/a 14672 n/a 13437 Auto 12.0 565
UE S-10 FXMQ25PAVE 24.0 / 17.0 n/a 9213 n/a 7879 Auto 11.5 318
UE S-17 FXMQ25PAVE 24.0 / 17.0 n/a 9213 n/a 7879 Auto 11.5 318
UE S-14 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE S-16 FXMQ25PAVE 24.0 / 17.0 n/a 9213 n/a 7879 Auto 11.5 318
UE S-15 FXMQ32PAVE 24.0 / 17.0 n/a 11772 n/a 9213 Auto 10.1 335
UE S-8 FXMQ50PAVE 24.0 / 17.0 n/a 18426 n/a 15914 Auto 11.4 636
UE S-11 FXMQ25PAVE 24.0 / 17.0 n/a 9213 n/a 7879 Auto 11.5 318
UE S-7 FXMQ50PAVE 24.0 / 17.0 n/a 18426 n/a 15914 Auto 11.4 636

Required cooling capacity towards the outdoor unit: 282867BTU/h.

The calculation shows the peak discharge temperatures (lowest temperature in case of cooling mode / highest
temperature in case of heating mode), assuming the indoor unit is running at full load at the given indoor
temperature design conditions. In practice the discharge temperature will modulate based on actual capacity
requirements and during defrost mode (heating mode).
The analysis of the suction and discharge temperature values may help in preventing a cold draft and to ensure a
thermal comfort level.

Name Sound PS MCA WxHxD Wght


dBA A mm kg
UE S-20 28-33 220V 1ph 0.6 550×300×700 25
UE S-21 29-33 220V 1ph 0.6 550×300×700 25
UE S-22 28-33 220V 1ph 0.6 550×300×700 25
UE S-2 38-42 220V 1ph 1.8 1000×300×700 35
UE S-3 38-42 220V 1ph 1.8 1000×300×700 35
UE S-1 29-33 220V 1ph 0.6 550×300×700 25
UE S-5 29-33 220V 1ph 0.6 550×300×700 25
UE S-4 38-42 220V 1ph 1.8 1000×300×700 35
UE S-9 28-33 220V 1ph 0.6 550×300×700 25
UE S-6 37-41 220V 1ph 1.6 1000×300×700 35
UE S-19 30-34 220V 1ph 0.6 550×300×700 25
UE S-18 28-33 220V 1ph 0.6 550×300×700 25
UE S-12 30-34 220V 1ph 0.6 550×300×700 25
UE S-13 35-39 220V 1ph 1.4 700×300×700 27
UE S-10 28-33 220V 1ph 0.6 550×300×700 25

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 11
Name Sound PS MCA WxHxD Wght
dBA A mm kg
UE S-17 28-33 220V 1ph 0.6 550×300×700 25
UE S-14 30-34 220V 1ph 0.6 550×300×700 25
UE S-16 28-33 220V 1ph 0.6 550×300×700 25
UE S-15 30-34 220V 1ph 0.6 550×300×700 25
UE S-8 37-41 220V 1ph 1.6 1000×300×700 35
UE S-11 28-33 220V 1ph 0.6 550×300×700 25
UE S-7 37-41 220V 1ph 1.6 1000×300×700 35

Outdoor unit placed at the same level as the indoor units.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 12
3. Outdoor Unit Details
3.1. Table of Abbreviations
Name Logical name of the device
Model Device model name
▼ Optimized selection: Smaller outdoor model selected than standard proposed model
Tmp C Outdoor temperature in cooling
CC Available cooling capacity
Rq CC Required cooling capacity
Tmp H Outdoor conditions in heating (dry bulb temp. / wet bulb temp.)
HC Available heating capacity (integrated heating capacity)
Rq HC Required heating capacity
Piping Largest distance from indoor unit to outdoor unit
Bse Refr Standard factory refrigerant charge (5m actual piping length)
excluding extra refrigerant charge
For calculation of extra refrigerant charge refer to the databook
Ex Refr Extra refrigerant charge
PS Power supply (voltage and phases)
MCA Minimum Circuit Amps
WxHxD WidthxHeightxDepth
Wght Weight of the device

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 13
3.2. Outdoor Details
Name Model Comb Tmp C CC Rq CC Tmp H HC Rq HC
% °C BTU/h BTU/h °C BTU/h BTU/h
VRV - PISO 4 RXQ30TATL ▼ 122 34.0 256784 (-24.5%) 340020
VRV - PISO 3 RXQ30TATL ▼ 122 34.0 256784 (-24.5%) 340020
VRV - PISO 2 RXQ28TATL ▼ 123 34.0 243422 (-24%) 320401
VRV - PISO 1 RXQ26TATL ▼ 123 34.0 227240 (-23.7%) 297880
VRV - SOTANO RXQ24TATL ▼ 127 34.0 214944 (-24%) 282867

Name Model Piping Refrigerant


m Type Bse Refr Ex Refr
kg kg
VRV - PISO 4 RXQ30TATL 66.1 R410A 16.8 18.4
VRV - PISO 3 RXQ30TATL 66.1 R410A 16.8 18.4
VRV - PISO 2 RXQ28TATL 62.6 R410A 16.7 18.9
VRV - PISO 1 RXQ26TATL 57.1 R410A 16.4 16.9
VRV - SOTANO RXQ24TATL 69.3 R410A 12.6 14.0

Name Model PS MCA WxHxD Wght


A mm kg
VRV - PISO 4 RXQ30TATL 220V 3ph
× RXQ18TATL 55 1240×1657×765 285
× RXQ12TATL 43.1 930×1657×765 195
VRV - PISO 3 RXQ30TATL 220V 3ph
× RXQ18TATL 55 1240×1657×765 285
× RXQ12TATL 43.1 930×1657×765 195
VRV - PISO 2 RXQ28TATL 220V 3ph
× RXQ16TATL 55 1240×1657×765 285
× RXQ12TATL 43.1 930×1657×765 195
VRV - PISO 1 RXQ26TATL 220V 3ph
× RXQ18TATL 55 1240×1657×765 285
× RXQ8TATL 29.9 930×1657×765 185
VRV - SOTANO RXQ24TATL 220V 3ph
× RXQ12TATL 43.1 930×1657×765 195
× RXQ12TATL 43.1 930×1657×765 195

Sufficient distance should be respected between the modules according to the service & operation space rules as
mentioned in the databook.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 14
4. Piping Diagrams
Pipes marked with * in the diagrams must be connected to the device with a reducing joint.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 15
4.1. Piping VRV - PISO 4

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 16
VRV - PISO 4
RXQ30TATL
RXQ18TATL RXQ12TATL

⅝"×1⅛" ½"×1⅛"

BHFP22P100

35.0m 0.8m 1.0m


¾"×1⅜" ⅝"×1⅛" ¼"×½"
KHRP26A73T + KHRP26A72T
KHRP26M73TP
UE 4-21
FXMQ50PAVE
5.4m 1.9m 6.7m
⅝"×1⅛" ½"×1⅛" ¼"×½"
KHRP26A72T KHRP26A72T

UE 4-24
FXMQ20PAVE
4.1m 1.4m
½"×1⅛" ⅜"×⅝"
KHRP26A72T

UE 4-22
FXMQ80PAVE
4.7m 1.4m
⅜"×⅞" ⅜"×⅝"
KHRP26A33T

UE 4-23
FXMQ80PAVE
1.3m 2.0m
⅜"×¾" ⅜"×⅝"
KHRP26A22T

UE 4-1
FXMQ63PAVE
1.0m 2.3m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE 4-2
FXMQ25PAVE
0.8m 1.8m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE 4-10
FXMQ32PAVE
1.5m 3.1m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE 4-3
FXMQ40PAVE
4.6m
¼"×½"

UE 4-4
FXMQ32PAVE
5.4m 3.2m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE 4-11
FXMQ32PAVE
5.3m 2.3m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE 4-5
FXMQ32PAVE
4.9m
¼"×½"

UE 4-6
FXMQ32PAVE
0.5m 2.0m
½"×1⅛" ¼"×½"
KHRP26A72T

UE 4-17
FXMQ32PAVE
2.2m 2.8m 1.7m
½"×1⅛" ⅜"×⅞" ¼"×½"
KHRP26A72T KHRP26A33T

UE 4-14
FXMQ32PAVE
2.3m 3.8m
⅜"×¾" ¼"×½"
KHRP26A22T

UE 4-12
FXMQ25PAVE
2.0m 1.4m 2.7m
⅜"×¾" ⅜"×⅝" ¼"×½"
KHRP26A22T KHRP26A22T

UE 4-7
FXMQ32PAVE
2.8m 1.6m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE 4-8
FXMQ32PAVE
6.1m
¼"×½"

UE 4-9
FXMQ40PAVE
2.5m 1.0m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE 4-13
FXMQ25PAVE
5.8m
¼"×½"

UE 4-16
FXMQ32PAVE
4.1m 0.8m 2.5m
⅜"×¾" ⅜"×⅝" ¼"×½"
KHRP26A22T KHRP26A22T

UE 4-20
FXMQ20PAVE
2.8m
¼"×½"

UE 4-15
FXMQ40PAVE
1.9m 2.2m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE 4-19
FXMQ32PAVE
5.5m
⅜"×⅝"

UE 4-18
FXMQ63PAVE

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 17
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 18
4.2. Piping VRV - PISO 3

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 19
VRV - PISO 3
RXQ30TATL
RXQ18TATL RXQ12TATL

⅝"×1⅛" ½"×1⅛"

BHFP22P100

35.0m 0.8m 1.0m


¾"×1⅜" ⅝"×1⅛" ¼"×½"
KHRP26A73T + KHRP26A72T
KHRP26M73TP
UE 3-21
FXMQ50PAVE
5.4m 1.9m 6.7m
⅝"×1⅛" ½"×1⅛" ¼"×½"
KHRP26A72T KHRP26A72T

UE 3-24
FXMQ20PAVE
4.1m 1.4m
½"×1⅛" ⅜"×⅝"
KHRP26A72T

UE 3-22
FXMQ80PAVE
4.7m 1.4m
⅜"×⅞" ⅜"×⅝"
KHRP26A33T

UE 3-23
FXMQ80PAVE
1.3m 2.0m
⅜"×¾" ⅜"×⅝"
KHRP26A22T

UE 3-1
FXMQ63PAVE
1.0m 2.3m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE 3-2
FXMQ25PAVE
0.8m 1.8m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE 3-10
FXMQ32PAVE
1.5m 3.1m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE 3-3
FXMQ40PAVE
4.6m
¼"×½"

UE 3-4
FXMQ32PAVE
5.4m 3.2m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE 3-11
FXMQ32PAVE
5.3m 2.3m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE 3-5
FXMQ32PAVE
4.9m
¼"×½"

UE 3-6
FXMQ32PAVE
0.5m 2.0m
½"×1⅛" ¼"×½"
KHRP26A72T

UE 3-17
FXMQ32PAVE
2.2m 2.8m 1.7m
½"×1⅛" ⅜"×⅞" ¼"×½"
KHRP26A72T KHRP26A33T

UE 3-14
FXMQ32PAVE
2.3m 3.8m
⅜"×¾" ¼"×½"
KHRP26A22T

UE 3-12
FXMQ25PAVE
2.0m 1.4m 2.7m
⅜"×¾" ⅜"×⅝" ¼"×½"
KHRP26A22T KHRP26A22T

UE 3-7
FXMQ32PAVE
2.8m 1.6m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE 3-8
FXMQ32PAVE
6.1m
¼"×½"

UE 3-9
FXMQ40PAVE
2.5m 1.0m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE 3-13
FXMQ25PAVE
5.8m
¼"×½"

UE 3-16
FXMQ32PAVE
4.1m 0.8m 2.5m
⅜"×¾" ⅜"×⅝" ¼"×½"
KHRP26A22T KHRP26A22T

UE 3-20
FXMQ20PAVE
2.8m
¼"×½"

UE 3-15
FXMQ40PAVE
1.9m 2.2m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE 3-19
FXMQ32PAVE
5.5m
⅜"×⅝"

UE 3-18
FXMQ63PAVE

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 20
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 21
4.3. Piping VRV - PISO 2

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 22
VRV - PISO 2
RXQ28TATL
RXQ16TATL RXQ12TATL

½"×1⅛" ½"×1⅛"

BHFP22P100

36.0m 1.2m 1.3m 3.6m


¾"×1⅜" ⅝"×1⅛" ⅜"×⅝" ¼"×½"
KHRP26A73T + KHRP26A72T KHRP26A22T
KHRP26M73TP
UE 2-18
FXMQ32PAVE
8.4m
¼"×½"

UE 2-25
FXMQ20PAVE
4.2m 3.3m
⅝"×1⅛" ¼"×½"
KHRP26A72T

UE 2-22
FXMQ40PAVE
2.2m 3.5m 4.2m
⅝"×1⅛" ½"×1⅛" ⅜"×⅝"
KHRP26A72T KHRP26A72T

UE 2-23
FXMQ80PAVE
2.6m 1.3m
⅜"×⅞" ⅜"×⅝"
KHRP26A33T

UE 2-24
FXMQ80PAVE
1.6m 1.2m 2.0m
⅜"×¾" ⅜"×⅝" ¼"×½"
KHRP26A22T KHRP26A22T

UE 2-1
FXMQ50PAVE
2.0m
¼"×½"

UE 2-2
FXMQ20PAVE
1.2m 1.3m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE 2-10
FXMQ25PAVE
1.4m 2.9m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE 2-3
FXMQ32PAVE
4.2m
¼"×½"

UE 2-4
FXMQ32PAVE
4.8m 1.7m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE 2-11
FXMQ25PAVE
3.6m 2.3m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE 2-5
FXMQ32PAVE
2.2m 2.2m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE 2-6
FXMQ32PAVE
4.8m
¼"×½"

UE 2-12
FXMQ25PAVE
2.0m 1.8m 2.1m
½"×1⅛" ⅜"×¾" ¼"×½"
KHRP26A72T KHRP26A22T

UE 2-14
FXMQ25PAVE
5.8m 1.0m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE 2-15
FXMQ20PAVE
2.4m 1.3m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE 2-13
FXMQ25PAVE
1.9m 3.3m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE 2-7
FXMQ32PAVE
1.4m 1.9m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE 2-8
FXMQ32PAVE
6.2m
¼"×½"

UE 2-9
FXMQ32PAVE
3.5m 1.6m 1.9m
⅜"×¾" ⅜"×⅝" ¼"×½"
KHRP26A22T KHRP26A22T

UE 2-21
FXMQ20PAVE
1.6m
¼"×½"

UE 2-16
FXMQ32PAVE
0.5m 8.6m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE 2-17
FXMQ32PAVE
2.5m 1.9m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE 2-20
FXMQ32PAVE
8.1m
⅜"×⅝"

UE 2-19
FXMQ63PAVE

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 23
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 24
4.4. Piping VRV - PISO 1

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 25
VRV - PISO 1
RXQ26TATL
RXQ18TATL RXQ8TATL

⅝"×1⅛" ⅜"×¾"

BHFP22P100

30.0m 6.0m 3.0m


¾"×1⅜" ⅝"×1⅛" ¼"×½"
KHRP26A73T + KHRP26A72T
KHRP26M73TP
UE 1-17
FXMQ50PAVE
1.6m 7.3m
½"×1⅛" ⅜"×⅝"
KHRP26A72T

UE 1-18
FXMQ80PAVE
3.9m 5.8m 2.9m
½"×1⅛" ⅜"×⅝" ¼"×½"
KHRP26A72T KHRP26A22T

UE 1-1
FXMQ50PAVE
4.8m
¼"×½"

UE 1-12
FXMQ25PAVE
1.4m 1.0m 1.6m
⅜"×⅞" ⅜"×⅝" ⅜"×⅝"
KHRP26A33T KHRP26A22T

UE 1-6
FXMQ63PAVE
3.2m
⅜"×⅝"

UE 1-3
FXMQ63PAVE
0.8m 1.7m
⅜"×⅝" ⅜"×⅝"
KHRP26A22T

UE 1-5
FXMQ63PAVE
7.6m
⅜"×⅝"

UE 1-4
FXMQ63PAVE
3.4m 0.9m
½"×1⅛" ¼"×½"
KHRP26A72T

UE 1-16
FXMQ20PAVE
1.9m 2.3m 3.2m
½"×1⅛" ⅜"×⅞" ¼"×½"
KHRP26A72T KHRP26A33T

UE 1-9
FXMQ40PAVE
1.3m 2.4m 1.1m
⅜"×⅞" ⅜"×⅞" ⅜"×⅝"
KHRP26A33T KHRP26A33T

UE 1-10
FXMQ63PAVE
0.9m 1.3m
⅜"×⅝" ⅜"×⅝"
KHRP26A22T

UE 1-11
FXMQ63PAVE
5.3m 3.9m
⅜"×⅝" ⅜"×⅝"
KHRP26A22T

UE 1-12
FXMQ63PAVE
5.6m
¼"×½"

UE 1-13
FXMQ20PAVE
5.0m 2.7m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE 1-8
FXMQ20PAVE
6.1m
¼"×½"

UE 1-7
FXMQ20PAVE
5.3m 2.3m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE 1-14
FXMQ20PAVE
3.7m
¼"×½"

UE 1-15
FXMQ20PAVE

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 26
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 27
4.5. Piping VRV - SOTANO

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 28
VRV - SOTANO
RXQ24TATL
RXQ12TATL RXQ12TATL

½"×1⅛" ½"×1⅛"

BHFP22P100

30.0m 1.0m 1.0m


⅝"×1⅜" ½"×1⅛" ¼"×½"
KHRP26A73T + KHRP26A72T
KHRP26M73TP
UE S-20
FXMQ25PAVE
1.0m 2.8m 2.0m
½"×1⅛" ⅜"×⅝" ¼"×½"
KHRP26A72T KHRP26A22T

UE S-21
FXMQ20PAVE
8.0m
¼"×½"

UE S-22
FXMQ25PAVE
6.1m 3.1m 2.8m
½"×1⅛" ⅜"×⅞" ⅜"×⅝"
KHRP26A72T KHRP26A33T

UE S-2
FXMQ63PAVE
3.2m 2.0m
⅜"×¾" ⅜"×⅝"
KHRP26A22T

UE S-3
FXMQ63PAVE
0.8m 1.7m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE S-1
FXMQ20PAVE
0.8m 2.5m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE S-5
FXMQ20PAVE
3.1m
⅜"×⅝"

UE S-4
FXMQ63PAVE
4.5m 1.8m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE S-9
FXMQ25PAVE
7.9m
¼"×½"

UE S-6
FXMQ50PAVE
3.5m 6.3m
½"×1⅛" ¼"×½"
KHRP26A72T

UE S-19
FXMQ32PAVE
1.0m 1.4m
½"×1⅛" ¼"×½"
KHRP26A72T

UE S-18
FXMQ25PAVE
2.0m 6.4m 1.5m
½"×1⅛" ⅜"×⅝" ¼"×½"
KHRP26A72T KHRP26A22T

UE S-13
FXMQ40PAVE
2.6m 1.2m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE S-12
FXMQ32PAVE
4.1m
¼"×½"

UE S-10
FXMQ25PAVE
3.2m 3.2m
⅜"×⅞" ¼"×½"
KHRP26A33T

UE S-17
FXMQ25PAVE
4.1m 4.3m
⅜"×⅞" ¼"×½"
KHRP26A33T

UE S-14
FXMQ32PAVE
1.4m 1.6m
⅜"×¾" ¼"×½"
KHRP26A22T

UE S-16
FXMQ25PAVE
2.3m 6.4m
⅜"×¾" ¼"×½"
KHRP26A22T

UE S-15
FXMQ32PAVE
2.4m 3.1m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE S-8
FXMQ50PAVE
1.4m 3.4m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE S-11
FXMQ25PAVE
13.0m
¼"×½"

UE S-7
FXMQ50PAVE

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 29
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 30
5. Wiring Diagrams
P1P2 = Please select the cable type and size in accordance with the databook.
F1F2 = Please select the cable type and size in accordance with the databook.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 31
5.1. Wiring VRV - PISO 4

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 32
P1,P2
VRV - PISO 4 UE 4-21 BRC1E63
RXQ30TATL FXMQ50PAVE
IN F1,F2 F1,F2 L, N 1.6A 1ph
RXQ18TATL
Q1,Q2 L1,L2,L3 P1,P2
UE 4-24 BRC1E63
55A 3ph
FXMQ20PAVE
RXQ12TATL F1,F2 L, N 0.6A 1ph
Q1,Q2 L1,L2,L3
43.1A 3ph P1,P2
UE 4-22 BRC1E63
FXMQ80PAVE
F1,F2 L, N 2.3A 1ph

P1,P2
UE 4-23 BRC1E63
FXMQ80PAVE
F1,F2 L, N 2.3A 1ph

P1,P2
UE 4-1 BRC1E63
FXMQ63PAVE
F1,F2 L, N 1.8A 1ph

P1,P2
UE 4-2 BRC1E63
FXMQ25PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 4-10 BRC1E63
FXMQ32PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 4-3 BRC1E63
FXMQ40PAVE
F1,F2 L, N 1.4A 1ph

P1,P2
UE 4-4 BRC1E63
FXMQ32PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 4-11 BRC1E63
FXMQ32PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 4-5 BRC1E63
FXMQ32PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 4-6 BRC1E63
FXMQ32PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 4-17 BRC1E63
FXMQ32PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 4-14 BRC1E63
FXMQ32PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 4-12 BRC1E63
FXMQ25PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 4-7 BRC1E63
FXMQ32PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 4-8 BRC1E63
FXMQ32PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 4-9 BRC1E63
FXMQ40PAVE
F1,F2 L, N 1.4A 1ph

P1,P2
UE 4-13 BRC1E63
FXMQ25PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 4-16 BRC1E63
FXMQ32PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 4-20 BRC1E63
FXMQ20PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 4-15 BRC1E63
FXMQ40PAVE
F1,F2 L, N 1.4A 1ph

P1,P2
UE 4-19 BRC1E63
FXMQ32PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 4-18 BRC1E63
FXMQ63PAVE
F1,F2 L, N 1.8A 1ph
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 33
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 34
5.2. Wiring VRV - PISO 3

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 35
P1,P2
VRV - PISO 3 UE 3-21 BRC1E63
RXQ30TATL FXMQ50PAVE
IN F1,F2 F1,F2 L, N 1.6A 1ph
RXQ18TATL
Q1,Q2 L1,L2,L3 P1,P2
UE 3-24 BRC1E63
55A 3ph
FXMQ20PAVE
RXQ12TATL F1,F2 L, N 0.6A 1ph
Q1,Q2 L1,L2,L3
43.1A 3ph P1,P2
UE 3-22 BRC1E63
FXMQ80PAVE
F1,F2 L, N 2.3A 1ph

P1,P2
UE 3-23 BRC1E63
FXMQ80PAVE
F1,F2 L, N 2.3A 1ph

P1,P2
UE 3-1 BRC1E63
FXMQ63PAVE
F1,F2 L, N 1.8A 1ph

P1,P2
UE 3-2 BRC1E63
FXMQ25PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 3-10 BRC1E63
FXMQ32PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 3-3 BRC1E63
FXMQ40PAVE
F1,F2 L, N 1.4A 1ph

P1,P2
UE 3-4 BRC1E63
FXMQ32PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 3-11 BRC1E63
FXMQ32PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 3-5 BRC1E63
FXMQ32PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 3-6 BRC1E63
FXMQ32PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 3-17 BRC1E63
FXMQ32PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 3-14 BRC1E63
FXMQ32PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 3-12 BRC1E63
FXMQ25PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 3-7 BRC1E63
FXMQ32PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 3-8 BRC1E63
FXMQ32PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 3-9 BRC1E63
FXMQ40PAVE
F1,F2 L, N 1.4A 1ph

P1,P2
UE 3-13 BRC1E63
FXMQ25PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 3-16 BRC1E63
FXMQ32PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 3-20 BRC1E63
FXMQ20PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 3-15 BRC1E63
FXMQ40PAVE
F1,F2 L, N 1.4A 1ph

P1,P2
UE 3-19 BRC1E63
FXMQ32PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 3-18 BRC1E63
FXMQ63PAVE
F1,F2 L, N 1.8A 1ph
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 36
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 37
5.3. Wiring VRV - PISO 2

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 38
P1,P2
VRV - PISO 2 UE 2-18 BRC1E63
RXQ28TATL FXMQ32PAVE
IN F1,F2 F1,F2 L, N 0.6A 1ph
RXQ16TATL
Q1,Q2 L1,L2,L3 P1,P2
UE 2-25 BRC1E63
55A 3ph
FXMQ20PAVE
RXQ12TATL F1,F2 L, N 0.6A 1ph
Q1,Q2 L1,L2,L3
43.1A 3ph P1,P2
UE 2-22 BRC1E63
FXMQ40PAVE
F1,F2 L, N 1.4A 1ph

P1,P2
UE 2-23 BRC1E63
FXMQ80PAVE
F1,F2 L, N 2.3A 1ph

P1,P2
UE 2-24 BRC1E63
FXMQ80PAVE
F1,F2 L, N 2.3A 1ph

P1,P2
UE 2-1 BRC1E63
FXMQ50PAVE
F1,F2 L, N 1.6A 1ph

P1,P2
UE 2-2 BRC1E63
FXMQ20PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 2-10 BRC1E63
FXMQ25PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 2-3 BRC1E63
FXMQ32PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 2-4 BRC1E63
FXMQ32PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 2-11 BRC1E63
FXMQ25PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 2-5 BRC1E63
FXMQ32PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 2-6 BRC1E63
FXMQ32PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 2-12 BRC1E63
FXMQ25PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 2-14 BRC1E63
FXMQ25PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 2-15 BRC1E63
FXMQ20PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 2-13 BRC1E63
FXMQ25PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 2-7 BRC1E63
FXMQ32PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 2-8 BRC1E63
FXMQ32PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 2-9 BRC1E63
FXMQ32PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 2-21 BRC1E63
FXMQ20PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 2-16 BRC1E63
FXMQ32PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 2-17 BRC1E63
FXMQ32PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 2-20 BRC1E63
FXMQ32PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 2-19 BRC1E63
FXMQ63PAVE
F1,F2
The Xpress Selection Program is property of Daikin EuropeL,NV.
N 1.8A 1ph
Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 39
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 40
5.4. Wiring VRV - PISO 1

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 41
P1,P2
VRV - PISO 1 UE 1-17 BRC1E63
RXQ26TATL FXMQ50PAVE
IN F1,F2 F1,F2 L, N 1.6A 1ph
RXQ18TATL
Q1,Q2 L1,L2,L3 P1,P2
UE 1-18 BRC1E63
55A 3ph
FXMQ80PAVE
RXQ8TATL F1,F2 L, N 2.3A 1ph
Q1,Q2 L1,L2,L3
29.9A 3ph P1,P2
UE 1-1 BRC1E63
FXMQ50PAVE
F1,F2 L, N 1.6A 1ph

P1,P2
UE 1-12 BRC1E63
FXMQ25PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 1-6 BRC1E63
FXMQ63PAVE
F1,F2 L, N 1.8A 1ph

P1,P2
UE 1-3 BRC1E63
FXMQ63PAVE
F1,F2 L, N 1.8A 1ph

P1,P2
UE 1-5 BRC1E63
FXMQ63PAVE
F1,F2 L, N 1.8A 1ph

P1,P2
UE 1-4 BRC1E63
FXMQ63PAVE
F1,F2 L, N 1.8A 1ph

P1,P2
UE 1-16 BRC1E63
FXMQ20PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 1-9 BRC1E63
FXMQ40PAVE
F1,F2 L, N 1.4A 1ph

P1,P2
UE 1-10 BRC1E63
FXMQ63PAVE
F1,F2 L, N 1.8A 1ph

P1,P2
UE 1-11 BRC1E63
FXMQ63PAVE
F1,F2 L, N 1.8A 1ph

P1,P2
UE 1-12 BRC1E63
FXMQ63PAVE
F1,F2 L, N 1.8A 1ph

P1,P2
UE 1-13 BRC1E63
FXMQ20PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 1-8 BRC1E63
FXMQ20PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 1-7 BRC1E63
FXMQ20PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 1-14 BRC1E63
FXMQ20PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE 1-15 BRC1E63
FXMQ20PAVE
F1,F2 L, N 0.6A 1ph
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 42
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 43
5.5. Wiring VRV - SOTANO

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 44
P1,P2
VRV - SOTANO UE S-20 BRC1E63
RXQ24TATL FXMQ25PAVE
IN F1,F2 F1,F2 L, N 0.6A 1ph
RXQ12TATL
Q1,Q2 L1,L2,L3 P1,P2
UE S-21 BRC1E63
43.1A 3ph
FXMQ20PAVE
RXQ12TATL F1,F2 L, N 0.6A 1ph
Q1,Q2 L1,L2,L3
43.1A 3ph P1,P2
UE S-22 BRC1E63
FXMQ25PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE S-2 BRC1E63
FXMQ63PAVE
F1,F2 L, N 1.8A 1ph

P1,P2
UE S-3 BRC1E63
FXMQ63PAVE
F1,F2 L, N 1.8A 1ph

P1,P2
UE S-1 BRC1E63
FXMQ20PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE S-5 BRC1E63
FXMQ20PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE S-4 BRC1E63
FXMQ63PAVE
F1,F2 L, N 1.8A 1ph

P1,P2
UE S-9 BRC1E63
FXMQ25PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE S-6 BRC1E63
FXMQ50PAVE
F1,F2 L, N 1.6A 1ph

P1,P2
UE S-19 BRC1E63
FXMQ32PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE S-18 BRC1E63
FXMQ25PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE S-13 BRC1E63
FXMQ40PAVE
F1,F2 L, N 1.4A 1ph

P1,P2
UE S-12 BRC1E63
FXMQ32PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE S-10 BRC1E63
FXMQ25PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE S-17 BRC1E63
FXMQ25PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE S-14 BRC1E63
FXMQ32PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE S-16 BRC1E63
FXMQ25PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE S-15 BRC1E63
FXMQ32PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE S-8 BRC1E63
FXMQ50PAVE
F1,F2 L, N 1.6A 1ph

P1,P2
UE S-11 BRC1E63
FXMQ25PAVE
F1,F2 L, N 0.6A 1ph

P1,P2
UE S-7 BRC1E63
FXMQ50PAVE
F1,F2 L, N 1.6A 1ph
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 45
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 46
6. Device Options
6.1. Outdoor Unit Options
Model Description Used by
BHFP22P100 Outdoor unit multi connection piping kit VRV - SOTANO [RXQ24TATL] VRV - PISO 1 [RXQ26TATL] VRV - PISO 2 [RXQ28TATL]
VRV - PISO 3 [RXQ30TATL] VRV - PISO 4 [RXQ30TATL]

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 47

Das könnte Ihnen auch gefallen