Anchorage Bolt Design

I. Bolt Shear Resistance Inspection


1. Upper bolt connection
1.1. Bolt size and strength
Diameter of bolt Db = M22 mm
Area of Bolt Ab = 379.94 mm2
Tensile Strength Fub = 1040 Mpa " Refer to article 6.4.3 in AASHTO
Yeild Strength Fy = 940 Mpa LRD Design"

1.2. Number of Bolt


As longitudinal direction: n1 = 2
As transverse direction: n1 = 1
Total number of bolt Ns = 2
1.3. Spacing of Bolt
Allowed end distance e ≥ 38 mm " Refer to article
6.13.2.6.5 in AASHTO
Distance between bolts p ≥ 3xDb = ### LRFD Design"
Evaluation
e p
Description Check Check
mm mm
Transverse 45 OK 440 OK
Longitudinal 70 OK 110 OK
1.4. Shear resistance of bolt
Horizontal load Hmax = 200 kN
Nominal Shear Resistance of Bolt Rn
Rn = 0,48xAbxFubxNs"Article 6.13.2.12-1"
= 0.48 x 380 ### x 2
= 379 kN
The factored Shear Resistance of Bolt Rr
Rr " Refer to article
= f x Rn f = 0.8
6.5.4.2 in AASHTO
= 0.8 x 379 LRFD Design"
= 303 kN
Checking : Hmax < Rr = f x Rn
### < 303 kN OK
1. Lower bolt connection
1.1. Bolt size and strength
Diameter of bolt Db = M22 mm
Area of Bolt Ab = 379.94 mm2
Tensile Strength Fub = 1040 Mpa " Refer to article 6.4.3 in AASHTO
Yeild Strength Fy = 940 Mpa LRD Design"

1.2. Number of Bolt


As longitudinal direction: n1 = 2
As transverse direction: n1 = 2
Total number of bolt Ns = 4
1.3. Spacing of Bolt
≥ " Refer to article
Allowed end distance e 38 mm
6.13.2.6.5 in AASHTO
Distance between bolts p ≥ 3xDb = ### LRFD Design"
Evaluation
e p
Description Check Check
mm mm
Transverse 45 OK 440 OK
Longitudinal 70 OK 110 OK
1.4. Shear resistance of bolt
Horizontal load Hmax = 200 kN
Nominal Shear Resistance of Bolt Rn
Rn = 0,48xAbxFubxNs"Article 6.13.2.12-1"
= 0.48 x 380 ### x 4
= 759 kN
The factored Shear Resistance of Bolt Rr
Rr " Refer to article
= f x Rn f = 0.8
6.5.4.2 in AASHTO
= 0.8 x 759 LRFD Design"
= 607 kN
Checking : Hmax < Rr = f x Rn
### < 607 kN OK
II. Bearing Resistance Checking
The factored bearing resistance shall be taken as :
Pr = f x Pn
f = 0,7 "Article 5.5.4.2"

in which:
Nominal bearing resistance shall be taken as :
Pn = 0.85x ¦'c x A1x m "Article 5.7.5-2"
¦'c = 35 Mpa Compressive strength of concrete, Mpa
A1 = p x Dp2/4 Area under bearing device, mm2
A1 = 96163 mm2 Dp= 350 mm : Diameter of pot
m: modification factor m= 1.889 ≤ 2 OK
Pn = ###
Pr = 3783 kN
Checking:
The maximum vertical load ### < Pr = 3783 kN OK
V: Maximum vertical load Vuls = 2200 kN