The CARDIOVIT CS-200 is a multitasking system
solution, combining proven diagnostic capa-
bilities with the modern computer technology
and the most widely accepted user-interface.
CARDIOVIT CS-200

The Gold Standard


The CARDIOVIT CS-200 is the key to complete dia­
gnostic services, including:

• 12-channel Resting ECG


• Automatic ECG measurements and
interpretation (adult and pediatric)
• Vector Cardiography
• Pacemaker measurement
• QT Dispersion
• 12-channel fulldisclosure Exercise ECG,
with ST monitoring and rhythm monitoring
• 24-h ECG Holter
• Fully integrated data management system
• Connection to network systems
• Resting rhythm recording
• Analysis of Ventricular Late Potentials
• Spirometry
• Ergospirometry

The open system architecture allows the implemen-


tation of new programs, future system expansion
and network integration.

Innovations are our passion. Due to a number of high-perform- tests. The CARDIOVIT CS-200 keeps up
ance analysis and diagnostic tools, with your demands, be it in a labora-
They belong to the SCHILLER brand the CARDIOVIT CS-200 system has tory with a great work volume or in a
and are the reason why SCHILLER been able to extend its leading role. small practice where exercise tests
ECG systems are outstanding and It offers even easier to use applications are only performed occasionally.
­enjoy a worldwide reputation. that increase the productivity, as well And what is more:
as innovative network solutions. Our The CARDIOVIT CS-200 system can
Thanks to 35 years of experience and excellent technologies facilitate the be configured very easily according
close co-operation with the world’s clinical decision-making and increase to your information management
leading, practising cardiologists and the reliability of your diagnoses. requirements and supports simple as
physicians in the field of electrocar- well as complex network solutions.
diography, we can provide you the New, advanced algorithms and Exercise tests performed with the
CARDIOVIT CS-200, an ECG device analysis functions offer you addi- CARDIOVIT CS-200 system are charac-
which offers tailor-made solutions for tional opportunities when assessing terised by their accuracy, con­venient
professional diagnosis. the cardiac function during exercise application and efficiency.
Filtering the stress out of
stress test data
The greatest challenge in the exercise test environ-
ment is to manage noise and movement artefacts
present during the test. Several factors can create noise.
Direct function keys provide single button operation SCHILLER offers four industry-leading programs for arte-
for immediate ECG printouts. fact and noise management to effectively suppress noise
Autonomous emercency ECG (unique world wide). without compromising critical ECG data.

Leading-Edge Technology: SCHILLER


sets new standards in technology and
know-how.

Pacemaker measurement SAECG QT dispersion

SPF SCHILLER Powerline Frequency SBS SCHILLER Baseline Stabilizer: first attempt. Unlike traditional filtering
Filter: filter to suppress or greatly reduce systems, these filters do not influence
distortion-free suppression of su- base line fluctuations without distort- the important diagnostic features of
perimposed 50 or 60 Hz sinusoidal ing the low frequency content of the the ECG.
interferences by adaptive digital ST-T segment (for resting and exercise
filtering. ECGs). Excellent signal processing (noise
reduction) is decisive to produce
SSF SCHILLER Smoothing Filter, When used in combination, these a high-quality output that can be
SMF SCHILLER Myogram Filter filters provide the physician with ex- further evaluated and interpreted by
­(muscle tremor filter): cellent ECG quality. They neither the physician.
adaptive low pass smoothing filter distort the computerised ECG inter-
to suppress muscle tremor and high- pretation nor the computerised ECG
­frequency noise: without affecting the measurement values or the original
QRS complex or the ST-T segment. ECG complexes. They greatly help
the user to obtain a usable ECG at the
CS-200 Resting ECG

Dynamic algorithms
The CARDIOVIT CS-200 system offers you a com-
prehensive tool of clinically verified algorithms for the
analysis and interpretation of ECGs.

The unique combination of arrhythmia and morpho-


logical algorithms creates further application oppor-
tunities for the disease management. This allows you
to make more efficient therapeutic decisions and to
employ invasive tests more specifically.

The SCHILLER measurement and interpretation soft-


ware is the software of choice for hospitals, practices,
clinics and clinical research institutes due to its ex-
cellent quality and reliability.

•  SCHILLER measurement and inter- •  Pacemaker detection software: •  Vector cardiography (optional): the
pretation software for children and corresponding to the latest pace- vector ECG gives you a three-dimen-
adults (optional): 12-lead ECG analy- maker technologies. sional view of the electrical activity
sis, offering quality and reliability with- and improves the assessment of the
out compromise. Your most valuable •  Pacemaker measurement software interior-posterior part of the heart.
tool to get a clinically reliable second (optional): this advanced program
opinion. measures the pacing frequency, •  Serial ECG comparison: expan-
performs individual measurements of sion of the SCHILLER measurement
•  SAECG (high-resolution late poten- pulse width for atrial and ventricular and interpretation software, allowing
tial analysis) (optional): the intuitive stimulation and determines the AV the analysis of short- and long-term
illustration allows a more efficient as- intervals. changes in patient ECGs. Serial ECGs
sessment of arrhythmic substrate in proved to be most efficient in the
the heart, offering a convenient alter- detection of myocardial infarctions,
native to invasive procedures. both for new, asymptomatic myo-
cardial infarctions as well as for acute
ECG measurement and interpretation Serial comparison Vector cardiography

myocardial infarctions in symptomatic variability (HRV) – for patients with an acute coronary syndrome (ACS). The
patients. Serial electrocardiography is increased risk of life-threatening ar- SCHILLER STP software package is an
above all indispensable when assess- rhythmia. additional option to the computer-
ing unstable angina pectoris. based ECG analysis. The informa-
•  Rhythm ECG recording: 12-lead full tion required for the calculation of
•  QT dispersion: indicates inhomo- disclosure ECG recording, collecting the probability of an acute cardiac
geneities in the ventricular repolari- up to 60 minutes of diagnostic data. ischaemia is delivered in real time
sation. The greater the QT dispersion, and is available for quality assurance
the more inhomogeneous the ven- •  Thrombolysis software (STP): helps matters at a later point.
tricular repolarisation and the greater physicians make decisions in preclini-
the risk for a sudden cardiac death cal care and in the emergency ward.
of the patient. QT dispersion analysis Taking into account medication, age,
can be used as a further non-invasive sex and ECG of a patient, the program
(This software was validated in clinical studies at the
method – in addition to signal aver- gives indications about the probabil- Thorax Centre of the Erasmus University in Rotterdam
aged ECG (SAECG) and heart rate ity of acute cardiac ischaemia or the (Professor Simoons))
CS-200 Exercise Testing
Redefining excellence in
exercise testing
The CARDIOVIT CS-200 exercise testing system combines
SCHILLER‘s proven ECG know-how with today‘s most
­modern, state-of- the-art personal computer innovations.

Covering the full Spectrum of


Electrocardiography
The CARDIOVIT CS-200 offers the performance
of a conventional exercise testing system:

• Built-in, full-size thermal printer for immediate


real-time printouts
• No start-up delay – instant ECG reports at the push
of a button
• Quick recording and printouts of ECGs
• Precise ECG measurements
• RS-232 and parallel interfaces
• Emergency ECG

Full disclosure

The CARDIOVIT CS-200 exercise system interface for automatic blood pres- tary Adobe Acrobat® PDF technology
benefits from the leading SCHILLER sure measurements. is used to create a portable electronic
technology and a flexible and easily file that can be e-mailed for conven-
customised interface that meets the The CARDIOVIT CS-200 exercise ient review. This provides easy access
varying needs of different clinical sce- system offers configurable user profiles to final report data without additional
narios. and the editing options known from software expenses.
Windows® to make the entire testing SCHILLER offers four patented, lead-
The CARDIOVIT CS-200 exercise and reporting process more efficient. ing analysis programs for artefact
system’s advanced features include Unlimited full disclosure patient stud- and noise management to provide
colour graphic auto-comparison with ies may be stored on the internal hard exceptionally clean ECG recordings
superimposed current and reference disk; moreover, the CARDIOVIT CS-200 without compromising the diagnos-
complexes, continuous screen pres- system allows using a high-speed laser tic quality of the ECG data. SCHILLER
entation of ST level and slope for all printer to significantly reduce paper ex- filters use the inherent redundancy of
12 average complexes, adaptation penses. In order to facilitate the timely the 12-lead ECG to measure consist-
and re-analysis of the J-point, and an distribution of test results, non-proprie- ency among the various leads. Just
Exercise-testing summary

Step exercise ST and arrhythm detection ST trends

as a clinician can discern artefact patient. Add the SpO2 measurement


from true signal by looking at multiple option to make your exercise ECG
leads, SCHILLER filters perform a real- system a complete and seamless
time analysis, resulting in clean ECG diagnostic test centre. Whenever
recordings without distortion of the required, the SCHILLER BP-200 plus de-
true underlying signal. livers reliable automatic blood pressure
measurements. The BP-200 plus propri-
SCHILLER BP-200 plus (optional) is an etary algorithms provide exceptional
ambulatory blood pressure monitor performance in this difficult environ-
for exercise testing. It is specifically ment. The hands-free interface makes
designed for the use with treadmill, BP-200 plus an indispensable part of
bicycle (ergometer) and pharmaco- exercise testing.
logical exercise tests. The SCHILLER
BP-200 plus monitors the blood pres-
sure, allowing you to focus on the
CS-200 Spirometry
PC spirometry of SCHILLER –
easy and accurate
SCHILLER PC spirometry allows you to determine several
diagnostically important parameters regarding static and
dynamic lung volumes.
You can measure the slow (ERV, IC, VCin, VCex) and
forced spirometry (FVC, VCmax, FEV1, MEF25, MEF50,
MEF75, PEF, FEV1%VCmax, ...) as well as the maximum
voluntary ventilation (MVV), and of course conduct pre-post
comparisons. Easy operation pays off. You can enlarge the
measurement windows to full screen with just a mouse
click.
Moreover, the scaling of the axes can be adapted so
that the curves are always clearly visible. SCHILLER PC Advanced, user-friendly spirometry PC-software
spirometry is available with two alternative flow sensors.
You can choose between the proven SP-150 disposable
flow sensor (for optimal hygiene without calibration) and
the reusable SP-20 sensor.

• Calibration program
• Spirometry / flow-volume / MVV / MV
• Trend report
• Interpretation program
• Pre-post comparison

Long-term comparisons / trends


CS-200 Ergo-Spirometry
Long experience in ergospirometry –
compact and concise
Key features at a glance:
•  The 12-channel ECG is completely integrated
in the system
•  Volume and Automatic gas calibration
•  Ambient module
•  Breath-by-Breath measurement
BP-200 plus •  Indirect Calorimetry
(Nutrition assessment: For a perfect diet)
•  Off-line blood gases/lactate
•  Training and nutrition reports (LFsport)  
•  Interpretation with Ergocheck
•  Online-display of test results
•  Intrabreath: Testing during exercise
•  Interfaces for hospital administration systems
•  Modularly expandable

For your daily routine, you need an or expansion at a later stage – bud­ In the same time it usually takes you
easy-to-use tool. We have therefore get admitting or demands requiring. to perform an exercise ECG or a pul-
made the CARDIOVIT CS-200 ergo- monary function test, you can con-
spirometry even faster, more accurate To meet the high requirements, flow duct a complete, integrated meta-
and, above all, more economical. sensors are used in the CARDIOVIT bolic test with the CARDIOVIT CS-200
CS-200 ergospirometry; these sensors ergospirometry. All you need for an
The CARDIOVIT CS-200 ergospiro- are checked automatically, saving exercise test with the CARDIOVIT
metry is specialised in ergo-spiro- you time and effort. The patented CS-200 ergospirometry is integrated in
metric routine examinations. It com- flow sensors guarantee accurate a small device. No chemicals, expen-
bines everything you need in your measurements, have a small dead sive disposable tubes or flow sensors
daily routine, including practice- space and are light and small. They are required. All you need is calibra-
oriented performance data and an are therefore more comfortable for tion gas and disposable ECG elec-
unparalleled ease of use. And the fa- the patient, who is wearing a mask trodes (unless you prefer suction elec-
mous SCHILLER quality, of course. The or mouthpiece with the sensor during trodes (optional)).
modular concept permits upgrades the test.
SEMA-200 Data Management
Manages and Archives Holter ECG
und Ambulatory Blood Pressure
Monitor (ABPM) data
Furthermore, in seamless combination with other SCHILLER
applications, SEMA-200 will also manage and archive the
following additional diagnostic data formats:

• Up to 72 hours of Ambulatory (Holter) ECG monitoring


(requires MT-200 Holter program) including analysis of 2
or 3 channels, ST analysis, template matching, HR trend
overview, HR variability, pacemaker templates, and re-
classification in less than 2 seconds with „drag & drop“
functionality.

• Up to 48 hours of Ambulatory Blood Pressure monitoring 24h ECG Holter


(requires MT-300 ABP program) including a measurement MT-101 nano
table, comprehensive statistical calculations, trends, and
histograms.

Long term blood


pressure Holter
BR-102 plus

24h
ECG Holter
MT-101

Are you contemplating an ECG cludes the functionality of a stand- ­ ntry of patient data and minimises
e
management system? No problem ard SEMA-200 client directly on the the probability of data entry errors.
with the CARDIOVIT CS-200. device. This offers unprecedented The optional barcode reader further
access to all previous studies and pa- increases efficiency through the au-
Comprehensive network connectiv- tient information at the time of testing. tomated entry of patient identifiers.
ity gives you access to the SCHILLER Analysis, interpretation and validation
SEMA cardiology information system, of recordings can either be done on With the worklist function, a list of or-
optimising the workflow and enhanc- the device itself, or in the comfort of ders including patient demographics
ing the unit‘s functionality. Network your office on a SEMA-200 client. is downloaded directly to the device
access allows you to work more from HIS or EMR systems. This auto-
­efficiently and receive additional sup- Patient demographics can be auto- mates the ECG acquisition process
port for clinical decisions. matically synchronised with Hospital and provides a traceable closed-loop
Information Systems (HIS) or Electronic workflow from order entry to billing.
When connected to the SEMA-200 Medical Record (EMR) systems. This
system, the CARDIOVIT CS-200 in- accelerates the time-consuming
AT-2 plus AT-101 Family

Directory Services
ion
at
m
or
Inf
er
Us

Patient Order Request


Demographics
Recordings

SEMA-200

AT-104 PC
HIS H
AT-10 plus
AT-110

AT-102

CS-200

Patient
Demographics

Worklist Order Results

Patient record SEMAweb 3D visualisations

Integration with the SEMA-200 data


management system enables the
long-term archiving of your data, with
easy to use search and editing tools
to efficiently manage patients and
recordings. Standard interfaces via
HL7, GDT and XML further enable the
CARDIOVIT CS-200 and SEMA-200
system to become integrated com-
ponents in a larger systems solution,
avoiding isolated information silos.

THE ART OF CONNECTIVITY


Technical Data CS-200

System: Resting ECG: BP-200 plus Blood Pressure


Dimension: 60 x 62 x 153 cm (l x w x h) -  Simultaneous acquisition of all 8 active electrode Measurement (Option):
Weight: 71 kg signals from 12 leads
Monitor: Size: 19“ TFT LCD -  Sampling frequency: 4000 Hz
Operator interface: -  Pacemaker detection: ≥ ± 2 mV/≥ 0.1 msec. System:
-  Standard alphanumeric PC keyboard with -  Emergency ECG Dimension: 222 x155 x 96 mm (l x w x h)
built-in trackball -  Resting rhythm with event marking Weight: 1.08 kg (including SPO2, ECG Amp, excluding
-  Mouse -  QT dispersion batteries)
-  Direct function keys for Start/Stop/MAN/AUTO-ECG -  Review and re-measurement of all stored data Power supply:
Power requirements: 115/230 V (nominal), 50/60 Hz Options: External supply+9 VDC output @ 0-1.7 amps
Power consumption: Max. 80 VA -  Computer-aided ECG interpretation for LCD: Backlit graphical LCD with multi-language menu
Battery: pediatric and adult ECGs (C) Interface:
Built-in uninterruptable power supply (UPS) provides -  Vector Cardiography -  ECG and RS-232 interface for SCHILLER ECG stress
at least 3 minutes of back-up power to system and -  Late Potential analysis (time domaine) test systems
printer (without monitor) in the event of power failure. -  USB interface
Operating system: Programming: Menu guidance 5 buttons
WINDOWS™ XP Professional multi lingual Exercise ECG: Safety standards: IEC/EN 60601-1; UL 60601-1, C22.2
Storage medium: -  Arrhythmia detection and review No. 601.1-M90; IEC/EN 60601-1-2 (EMC)
-  Hard disk -  Standard and free programmable exercise proto- Protection Class: I according to IEC/EN 60601-1 ­(option:
-  DVD R/RW cols for bicycles and treadmills internal power supply)
Network (Standard) -  Automatic NIBP measurement Applied Part: BF/CF according IEC/EN 60601-1
-  Enlarged QRS complex with superimposed re- Conformity: 0123 according Directive 93/42/ECC
ference beat selectable for each lead ­(Medical Devices)
Hardware Options: -  Real time continuous ST analysis, amplitude and Classification: II a according Directive 93/42/EEC
-  Laser or inkjet printer slope graphic
-  ECG cable arm -  Online ST measurement adjustment Measurement:
-  Vacuum electrode system -  Re-analyse possibility of complete exercise test Methods of measurement:
-  Treadmill, ergometer or reclining ergometer with ST, HR and NIBP trend graphic Primary: SCHILLER K-Sound Analysis with or without QRS
-  BP-200 plus blood pressure device -  Borg scale, symptoms, end point criteria tables trigger signal for stress test
- Bottle holder (holder for gel bottle -  Emergency ECG any time possible Secondary: Oscillometric with smooth linear deflation
for suction device) Options: for resting measurements
- Holder for Bar Code Scanner -  Full disclosure rhythm review Measurement range:
- Holder for Defibrillators (Fred easy types) - Systolic: 50 – 270 mmHg
- Spirovit Sensor holder for SP-20 and SP-150 - Diastolic: 20 – 150 mmHg
All hardware options may be added at any time and Filter: - Heart rate: 40 – 250 BPM
are easily retrofitted. SPF SCHILLER Powerline Frequency Filter: Measurement intervals: 2 – 20 min.
Distortion-free suppression of superimposed 50 or 60 Hz Memory capacity: 200 measurements
sinusoidal interferences by adaptive digital filtering QRS Trigger:
Printing: SSF SCHILLER Smoothing Filter, SMF SCHILLER Myo- - Signal from external ECG source
Chart paper: Thermoreactive, z-fold, gram Filter (muscle tremor filter): 25 Hz/35 Hz low pass Sampling intervals: On command from ECG stress test
width: A4, approx. 60 m, ready-to-file smoothing filter to suppress muscle tremor and high- system, manual or automatic measurement periods
Printing process: frequency noise, without bothering the QRS complex from 2 to 20 minute intervals
Built-in high resolution thermal printer, 8 dots/mm – SBS SCHILLER Baseline Stabilizer: Filter to suppress or gre- Indicator for the user: On screen message and audio
amplitude axis, 40 dots/mm – time axis, @ 25 mm/sec. atly reduce baseline fluctuations without changing the tone for user defined ranges
Paper speed: measurement values (for Resting and Exercise ECGs)
5 / 10 / 12.5 / 25 / 50 mm/sec. (manual printout) Online, Offline Anti Aliasing (to smooth the ECG signal
Sensitivity: traces) Optional unit version:
5 / 10 / 20 mm/mV, automatic or manual selection Built in SpO2 module and internal ECG amplifier (to
Print format: generate the QRS- trigger signal to support the blood
6 /12 channel printout optimally shown on a width of SEMA 200: pressure measurement)
A4 (200 mm), automatic baseline adjustment -  Comprehensive management of diagnostic data
Channels: 12 of resting ECG, exercise ECG, spirometry, ergo-
External printer (optional): spirometry, 24-h Holter ECG, QT dispersion, SAECG Standard accessories:
Printout on plain paper with laser or inkjet printer -  Importing possibility via memory stick, network or - Cuff (M)
Frequency response: 0.05 – 150 Hz (IEC/AHA) RS-232 interface - User guide
-  Validation of interpretation, measurement values - Velcro fixing pads to secure cuff
and patient data - Adhesive pads to fix the microphone
Safety Standards: -  Serial comparison of resting ECG data and curves - Ext. power supply
Specifications: on the screen - Head phone
Patient input: Fully floating and isolated, defibrillation - Communication cable to stress test system
protected (only with original SCHILLER patient cable) - QRS-trigger cable
Safety Standards:
IEC/EN 60601-1, UL 60601-1; C22.2 No. 601.1- M90, IEC/
EN 60601-2-25, IEC/EN 60601-1-2 (EMC) Optional accessories:
Protection Class: I according to IEC/EN 60601-1 (with - Several cuff sizes
internal power supply) - Batterie charger
Applied Part: CF according IEC/EN 60601-1 - Rechargeable batteries
Conformity: - SpO2 with cable and ear-sensor
according Directive 93/42/EEC (Medical Devices) - Pat. cable for internal ECG Amplifier
Classification: IIa according Directive 93/92/EEC (IEC coding, Code 1 / AHA coding, Code 2)
Environmental conditions: - Mini SD card for SW-Update and additional
-  Temperature, operating: 10 to 40 °C storage of the raw data
-  Temperature, storage: -10 to 50 °C
-  Relative humidity, operating: 25 to 95 %
(non-condensing)
-  Pressure, operating: 700 to 1060 hPa
Spirometry: Ergo-Spirometry: 24-h ECG Holter MT-101/200:
Measured values: Technical Description Gas Analyzer: ECG acquisition:
FVC: FVC, FEV0.5, FEV1.0, FEV3.0, FEV0.5/FVC, FEV1.0/FVC, Dimensions: (integrated into CS-200): ECG amplifier:
FEV3.0/FVC, FEF0.2-1.2, FEF25-75%, FEF75-85%, PEF, MEF75%, MEF50%, 15 x 15 x 15 cm (l x h x w) -  Galvanically isolated: 5.5 kVDC
MEF25%, FIVC, FIV1.0 , FIV1.0/FIVC, FIV10/FVC, PIF, MIF50% Weight: 2.35 kg -  Input impedance: > 10 MΩ
SVC: SVC, ERV, IRV, TV Power supply: 100 – 240 V, 50/60 Hz -  Maximum electrode potential: ± 300 mVDC
MV: MV, RR, TV Safety Class: VDE II, safety insulated, Class BF -  Common mode rejection: > 80 dB
MVV: MVV, RR, TV -  Dynamic range: ± 5.12 mVAC
Presentation: -  Frequency response: 0.05 – 150 Hz (-3 dB)
- Flow/volume loop Measurement Methods: -  Digital resolution: 2.5 μV, 12 bit
- Volume/time graph Breath-by-breath gas analysis -  Sampling frequency: 500 or 1000 Hz
- Measurement values table Flow volume processing according to ECCS or ATS -  Time constant: = 3.2 sec.
- Trend display at >1 recording per patient Amount of gas adjusted with STPD -  Pacemaker detection: ± 2..200 mV / 0.1..2 msec.
- Interpretation quadrant Environmental sensors: Patient cable:
Prediction equation: -  Flow sensor insensitive to moisture: 0 to ± 17 l/sec., -  2-lead: 4 electrodes
Adults: ECCS, Austria, Crapo, Morris, Knudson, Knudson 76, resolution 10 ml/sec -  3-lead: 6 electrodes
Polgar, Berglund, Finland, India, Composite -  Temperature: 0 to 50 °C
Children: Quanjer & Tammeling, Austria, India, -  Barometer pressure: 600 to 1050 mBar Recorder:
Knudson, Knudson 76, Polgar (measurement range: -100 to 3500 m above sea level) Dimensions:
Extrapolated predicted values Flow measurement (patented diaphragm spiroceptor): 94 x 61 x 20 mm, approx. 110 g (including battery)
Comparison: Pre/post medication possible Bi-directional pneumotacho flow sensor insensitive to Data recording: Simultaneous 2- or 3-channel recor-
Standards compliance: ATS, ATS 94, OSHA, NIOSH moisture. Measurement range 0 to ± 17 l/sec., max. ding, differential
SPIROVIT SP-150 Pneumotach flowsensor for pulmonary deviation ± 2.5 %, volume range 0 to 300 l, resolution
function testing with disposable mouthpiece: 10 ml/sec.
Dimensions: 118 x 36 x 28 mm; approx. 120 g Gas analyzer
Measuring method: Pneumotachometer O2 micro fuel cell: 24-h ECG Holter MT-101 nano:
Measuring accuracy: According to ATS standards < 3 % Measurement range: 0 to 100 % O2 ECG acquisition:
Flow impedance: < 0.2 mbar* s/l at 12 l/s Measurement accuracy: Better than ± 0.1 % ECG amplifier:
SPIROVIT SP-20 Pneumotach flowsensor for pulmonary Response time: < 80 msec. (10 to 90 %) -  Galvanically isolated: 5.5 kVDC
function testing with reusable mouthpiece: Ultra sound density method analyzer CO2: -  Input impedance: > 10 MΩ
Dimensions: 125 x 36 x 28 mm, approx. 160 g Measurement range: 0 to 17.5 % CO2 -  Maximum electrode potential: ± 300 mVDC
Measuring method, measuring ranges, measuring ac- Measurement accuracy: Better than ± 0.1 % -  Common mode rejection: > 80 dB
curacy, flow impedance same as SP-150. Response time: < 80 msec. (10 to 90 %) -  Dynamic range: ± 5.12 mVAC
Basic unit: Fully automatic zero alignment and calibration of the -  Frequency response: 0.05 – 150 Hz (-3 dB)
•  CS-200 Spirometry program with 4 PC based gas analyzers at minimal gas consumption -  Digital resolution: 2.5 μV, 12 bit
measurement programs for inspiratory and Automatic measurement of ambient conditions -  Sampling frequency: 500 or 1000 Hz
expiratory pulmonary function tests Manual entry of blood gas values (lactate etc.) -  Time constant: = 3.2 sec.
•  1 pneumotach sensor (choice of SP-150 for -  Pacemaker detection: ± 2..200 mV / 0.1..2 msec.
disposable or SP-20 for reusable mouthpieces) Patient cable:
•  Accessories: 2 noseclips and either 1 pack of Software: -  2-lead: 5 electrodes
disposable plastic mouthpieces (for SP-150) or Parameters: METS, VT, VE, fR, VO2, VCO2, RQ, VE/V, -  3-lead: 7 electrodes
1 pack of disposable filters (for SP-20) VO2-, VCO2-equivalents, O2-pulse, VD/VT, FEO2, FECO2
•  1 operating manual as well as secondary parameters Recorder:
Hardware option: Calibration syringe, P/N 2.100027 Automatic determination of the anaerobic threshold Dimensions:
after V-slope, CO2 excess, EQO2 minimum or RQ 62 x 58 x 18 mm (l/w/h)
Scaling optimization for the diagrams Weight including rechargeable battery and memory
Editing possibility for all basic parameters card: 66 g
Export/import function with standardized protocols for Data recording: Simultaneous 2- or 3-channel recor-
integration into HIS ding, differential

Operating Conditions:
Ambient temperature: Between 10 and 40 °C Long-term Blood Pressure Holter
Relative humidity: Between 30 and 90 % BR-102 plus:
Atmospheric pressure: Between 900 and 1060 hPa System:
Dimensions:
The PowerCube produced by Ganshorn Medizin Electronic GmbH, Nie- 101 x 69 x 28 mm (l x w x h)
derlauer, Germany, has been integrated into the CARDIOVIT CS-200 Weight including rechargeable batteries: 198 g
Ergo-Spiro device. It fully complies with SCHILLER‘s view on quality. Power supply: 2 rechargeable NiMH batteries (≥ 2300
mAh), Type “AA”
LCD: Backlit graphical LCD with multi-language menu
Interface: USB interface for data transfer and settings
Programming: Menu guidance; 2 buttons

Measurement:
Methods of measurement: Auscultatoric (Korotkoff/Riva-
Rocci) and oscillometric
Measurement duration: 24 h or 48 h
Measuring range, blood pressure: 30 – 300 mmHg
Measuring range, heart rate: 25 – 300 bpm
Deflation rate: 2 – 9 mmHg/sec., automatic
Measurement intervals: 10 – 120 min.
Memory capacity: Over 400 measurements and 30 sec.
of voice recording
Option: Mini SD card for the additional storage of the raw
data

All technical data is subject to changes aiming to continuous


innovations.
ZE
N

R
G

L
SI ND
A
DE

Climate-neutral printing
©1996 Forest Stewardship Council
www.fsc.org SQS-COC-100333
Mixed Sources
Product group sourced from
exemplary managed forests
FA C T U R
NU E
A

D
M

©1996 Forest Stewardship Council


IN

www.fsc.org SQS-COC-100333
Mixed Sources
D AND

Product group sourced from


exemplary managed forests
Extra Light für

SWITZE
Offset-Druck
NE
IG

R
L
S A
N
DE D

Asia Japan
SCHILLER Asia-Pacific / Malaysia SCHILLER Japan, Ltd.
52200 Kuala Lumpur, Malaysia Hiroshima 734-8551
Phone +603 6272 3033 Phone +81 82 250 2055
Fax +603 6272 2030 Fax +81 82 253 1713
sales@schiller.com.my koji.maekawa@schiller.jp
www.schiller-asia.com www.schiller.jp

Austria Poland
SCHILLER Handelsgesellschaft m.b.H. SCHILLER Poland Sp. z o.o.
A-4040 Linz PL-02-729 Warszawa
Phone +43 732 709 90 Phone +48 22 8432089
Fax +43 732 757 000 Fax +48 22 8432089
sales@schiller.at schiller@schiller.pl
www.schiller.at www.schiller.pl

China Russia & C.I.S.


SCHILLER Int‘l Trading (Shanghai) Co. Ltd. SCHILLER AG Rep. office
200335 Shanghai, China 125124 Moscow, Russia
Phone +86-21-62099627 Phone +7 (495) 970 11 33
Fax + 86-21-62099623 Fax +7 (495) 970 11 33
sales@schiller.com.my mail@schiller-ag.com
www.schiller.cn www.schiller-cis.com

France Spain
SCHILLER Médical S.A.S. SCHILLER ESPAÑA, S.A.
F-67162 Wissembourg/Cedex E-28230-Las Rozas/Madrid
Phone +33 3 88 63 36 00 Phone +34 91 713 01 76
Fax +33 3 88 94 12 82 Fax +34 91 355 79 33
info@schiller.fr schiller@schiller.es
www.schiller-medical.com www.schiller.es

France (distribution France) Switzerland


SCHILLER France S.A.S. SCHILLER-Reomed AG
F-77600 Bussy St Georges CH-8953 Dietikon
Phone +33 1 64 66 50 00 Phone +41 44 744 30 00
Fax +33 1 64 66 50 10 Fax +41 44 740 37 10
infoschiller@schiller-france.fr sales@schiller-reomed.ch
www.schiller-france.com www.schiller-reomed.ch

Germany Turkey
SCHILLER Medizintechnik GmbH SCHILLER TÜRKIYE
D-85521 Ottobrunn Okmeydani-Sisli – Istanbul
Phone +49 89 62 99 81-0 Phone +90 212 210 8681 (pbx)
Fax +49 89 609 50 90 Fax +90 212 210 8684
info@schillermed.de info@schiller.com.tr
www.schillermed.de www.schiller-turkiye.com

Hungary USA
SCHILLER Diamed Ltd. SCHILLER America Inc.
H-1141 Budapest Doral, Florida 33122
Phone +36 (1) 383-4780 / 460-9491 Phone +1 786 845 0620
Fax +36 (1) 383-4778 Fax +1 786 845 06 02
sales@schiller.at sales@schilleramerica.com
www.schilleramerica.com
www.schiller-hungary.hu

India
SCHILLER Healthcare India Pvt. Ltd.
Mumbai - 400 001, India
07/09

Phone +91 22 6692 0520/ 2826 3520


Fax +91 22 2826 3525
*2.500222*

sales@schillerindia.com
www.schillerindia.com
Part no.: 2.500222

Headquarters: SCHILLER AG, Altgasse 68, CH-6341 Baar, Switzerland, Phone +41 41 766 42 42, Fax +41 41 761 08 80, sales@schiller.ch, www.schiller.ch

Das könnte Ihnen auch gefallen