Innovations are our passion. Due to a number of high-perform- tests. The CARDIOVIT CS-200 keeps up
ance analysis and diagnostic tools, with your demands, be it in a labora-
They belong to the SCHILLER brand the CARDIOVIT CS-200 system has tory with a great work volume or in a
and are the reason why SCHILLER been able to extend its leading role. small practice where exercise tests
ECG systems are outstanding and It offers even easier to use applications are only performed occasionally.
enjoy a worldwide reputation. that increase the productivity, as well And what is more:
as innovative network solutions. Our The CARDIOVIT CS-200 system can
Thanks to 35 years of experience and excellent technologies facilitate the be configured very easily according
close co-operation with the world’s clinical decision-making and increase to your information management
leading, practising cardiologists and the reliability of your diagnoses. requirements and supports simple as
physicians in the field of electrocar- well as complex network solutions.
diography, we can provide you the New, advanced algorithms and Exercise tests performed with the
CARDIOVIT CS-200, an ECG device analysis functions offer you addi- CARDIOVIT CS-200 system are charac-
which offers tailor-made solutions for tional opportunities when assessing terised by their accuracy, convenient
professional diagnosis. the cardiac function during exercise application and efficiency.
Filtering the stress out of
stress test data
The greatest challenge in the exercise test environ-
ment is to manage noise and movement artefacts
present during the test. Several factors can create noise.
Direct function keys provide single button operation SCHILLER offers four industry-leading programs for arte-
for immediate ECG printouts. fact and noise management to effectively suppress noise
Autonomous emercency ECG (unique world wide). without compromising critical ECG data.
SPF SCHILLER Powerline Frequency SBS SCHILLER Baseline Stabilizer: first attempt. Unlike traditional filtering
Filter: filter to suppress or greatly reduce systems, these filters do not influence
distortion-free suppression of su- base line fluctuations without distort- the important diagnostic features of
perimposed 50 or 60 Hz sinusoidal ing the low frequency content of the the ECG.
interferences by adaptive digital ST-T segment (for resting and exercise
filtering. ECGs). Excellent signal processing (noise
reduction) is decisive to produce
SSF SCHILLER Smoothing Filter, When used in combination, these a high-quality output that can be
SMF SCHILLER Myogram Filter filters provide the physician with ex- further evaluated and interpreted by
(muscle tremor filter): cellent ECG quality. They neither the physician.
adaptive low pass smoothing filter distort the computerised ECG inter-
to suppress muscle tremor and high- pretation nor the computerised ECG
frequency noise: without affecting the measurement values or the original
QRS complex or the ST-T segment. ECG complexes. They greatly help
the user to obtain a usable ECG at the
CS-200 Resting ECG
Dynamic algorithms
The CARDIOVIT CS-200 system offers you a com-
prehensive tool of clinically verified algorithms for the
analysis and interpretation of ECGs.
• SCHILLER measurement and inter- • Pacemaker detection software: • Vector cardiography (optional): the
pretation software for children and corresponding to the latest pace- vector ECG gives you a three-dimen-
adults (optional): 12-lead ECG analy- maker technologies. sional view of the electrical activity
sis, offering quality and reliability with- and improves the assessment of the
out compromise. Your most valuable • Pacemaker measurement software interior-posterior part of the heart.
tool to get a clinically reliable second (optional): this advanced program
opinion. measures the pacing frequency, • Serial ECG comparison: expan-
performs individual measurements of sion of the SCHILLER measurement
• SAECG (high-resolution late poten- pulse width for atrial and ventricular and interpretation software, allowing
tial analysis) (optional): the intuitive stimulation and determines the AV the analysis of short- and long-term
illustration allows a more efficient as- intervals. changes in patient ECGs. Serial ECGs
sessment of arrhythmic substrate in proved to be most efficient in the
the heart, offering a convenient alter- detection of myocardial infarctions,
native to invasive procedures. both for new, asymptomatic myo-
cardial infarctions as well as for acute
ECG measurement and interpretation Serial comparison Vector cardiography
myocardial infarctions in symptomatic variability (HRV) – for patients with an acute coronary syndrome (ACS). The
patients. Serial electrocardiography is increased risk of life-threatening ar- SCHILLER STP software package is an
above all indispensable when assess- rhythmia. additional option to the computer-
ing unstable angina pectoris. based ECG analysis. The informa-
• Rhythm ECG recording: 12-lead full tion required for the calculation of
• QT dispersion: indicates inhomo- disclosure ECG recording, collecting the probability of an acute cardiac
geneities in the ventricular repolari- up to 60 minutes of diagnostic data. ischaemia is delivered in real time
sation. The greater the QT dispersion, and is available for quality assurance
the more inhomogeneous the ven- • Thrombolysis software (STP): helps matters at a later point.
tricular repolarisation and the greater physicians make decisions in preclini-
the risk for a sudden cardiac death cal care and in the emergency ward.
of the patient. QT dispersion analysis Taking into account medication, age,
can be used as a further non-invasive sex and ECG of a patient, the program
(This software was validated in clinical studies at the
method – in addition to signal aver- gives indications about the probabil- Thorax Centre of the Erasmus University in Rotterdam
aged ECG (SAECG) and heart rate ity of acute cardiac ischaemia or the (Professor Simoons))
CS-200 Exercise Testing
Redefining excellence in
exercise testing
The CARDIOVIT CS-200 exercise testing system combines
SCHILLER‘s proven ECG know-how with today‘s most
modern, state-of- the-art personal computer innovations.
Full disclosure
The CARDIOVIT CS-200 exercise system interface for automatic blood pres- tary Adobe Acrobat® PDF technology
benefits from the leading SCHILLER sure measurements. is used to create a portable electronic
technology and a flexible and easily file that can be e-mailed for conven-
customised interface that meets the The CARDIOVIT CS-200 exercise ient review. This provides easy access
varying needs of different clinical sce- system offers configurable user profiles to final report data without additional
narios. and the editing options known from software expenses.
Windows® to make the entire testing SCHILLER offers four patented, lead-
The CARDIOVIT CS-200 exercise and reporting process more efficient. ing analysis programs for artefact
system’s advanced features include Unlimited full disclosure patient stud- and noise management to provide
colour graphic auto-comparison with ies may be stored on the internal hard exceptionally clean ECG recordings
superimposed current and reference disk; moreover, the CARDIOVIT CS-200 without compromising the diagnos-
complexes, continuous screen pres- system allows using a high-speed laser tic quality of the ECG data. SCHILLER
entation of ST level and slope for all printer to significantly reduce paper ex- filters use the inherent redundancy of
12 average complexes, adaptation penses. In order to facilitate the timely the 12-lead ECG to measure consist-
and re-analysis of the J-point, and an distribution of test results, non-proprie- ency among the various leads. Just
Exercise-testing summary
• Calibration program
• Spirometry / flow-volume / MVV / MV
• Trend report
• Interpretation program
• Pre-post comparison
For your daily routine, you need an or expansion at a later stage – bud In the same time it usually takes you
easy-to-use tool. We have therefore get admitting or demands requiring. to perform an exercise ECG or a pul-
made the CARDIOVIT CS-200 ergo- monary function test, you can con-
spirometry even faster, more accurate To meet the high requirements, flow duct a complete, integrated meta-
and, above all, more economical. sensors are used in the CARDIOVIT bolic test with the CARDIOVIT CS-200
CS-200 ergospirometry; these sensors ergospirometry. All you need for an
The CARDIOVIT CS-200 ergospiro- are checked automatically, saving exercise test with the CARDIOVIT
metry is specialised in ergo-spiro- you time and effort. The patented CS-200 ergospirometry is integrated in
metric routine examinations. It com- flow sensors guarantee accurate a small device. No chemicals, expen-
bines everything you need in your measurements, have a small dead sive disposable tubes or flow sensors
daily routine, including practice- space and are light and small. They are required. All you need is calibra-
oriented performance data and an are therefore more comfortable for tion gas and disposable ECG elec-
unparalleled ease of use. And the fa- the patient, who is wearing a mask trodes (unless you prefer suction elec-
mous SCHILLER quality, of course. The or mouthpiece with the sensor during trodes (optional)).
modular concept permits upgrades the test.
SEMA-200 Data Management
Manages and Archives Holter ECG
und Ambulatory Blood Pressure
Monitor (ABPM) data
Furthermore, in seamless combination with other SCHILLER
applications, SEMA-200 will also manage and archive the
following additional diagnostic data formats:
24h
ECG Holter
MT-101
Are you contemplating an ECG cludes the functionality of a stand- ntry of patient data and minimises
e
management system? No problem ard SEMA-200 client directly on the the probability of data entry errors.
with the CARDIOVIT CS-200. device. This offers unprecedented The optional barcode reader further
access to all previous studies and pa- increases efficiency through the au-
Comprehensive network connectiv- tient information at the time of testing. tomated entry of patient identifiers.
ity gives you access to the SCHILLER Analysis, interpretation and validation
SEMA cardiology information system, of recordings can either be done on With the worklist function, a list of or-
optimising the workflow and enhanc- the device itself, or in the comfort of ders including patient demographics
ing the unit‘s functionality. Network your office on a SEMA-200 client. is downloaded directly to the device
access allows you to work more from HIS or EMR systems. This auto-
efficiently and receive additional sup- Patient demographics can be auto- mates the ECG acquisition process
port for clinical decisions. matically synchronised with Hospital and provides a traceable closed-loop
Information Systems (HIS) or Electronic workflow from order entry to billing.
When connected to the SEMA-200 Medical Record (EMR) systems. This
system, the CARDIOVIT CS-200 in- accelerates the time-consuming
AT-2 plus AT-101 Family
Directory Services
ion
at
m
or
Inf
er
Us
SEMA-200
AT-104 PC
HIS H
AT-10 plus
AT-110
AT-102
CS-200
Patient
Demographics
Operating Conditions:
Ambient temperature: Between 10 and 40 °C Long-term Blood Pressure Holter
Relative humidity: Between 30 and 90 % BR-102 plus:
Atmospheric pressure: Between 900 and 1060 hPa System:
Dimensions:
The PowerCube produced by Ganshorn Medizin Electronic GmbH, Nie- 101 x 69 x 28 mm (l x w x h)
derlauer, Germany, has been integrated into the CARDIOVIT CS-200 Weight including rechargeable batteries: 198 g
Ergo-Spiro device. It fully complies with SCHILLER‘s view on quality. Power supply: 2 rechargeable NiMH batteries (≥ 2300
mAh), Type “AA”
LCD: Backlit graphical LCD with multi-language menu
Interface: USB interface for data transfer and settings
Programming: Menu guidance; 2 buttons
Measurement:
Methods of measurement: Auscultatoric (Korotkoff/Riva-
Rocci) and oscillometric
Measurement duration: 24 h or 48 h
Measuring range, blood pressure: 30 – 300 mmHg
Measuring range, heart rate: 25 – 300 bpm
Deflation rate: 2 – 9 mmHg/sec., automatic
Measurement intervals: 10 – 120 min.
Memory capacity: Over 400 measurements and 30 sec.
of voice recording
Option: Mini SD card for the additional storage of the raw
data
R
G
L
SI ND
A
DE
Climate-neutral printing
©1996 Forest Stewardship Council
www.fsc.org SQS-COC-100333
Mixed Sources
Product group sourced from
exemplary managed forests
FA C T U R
NU E
A
D
M
www.fsc.org SQS-COC-100333
Mixed Sources
D AND
SWITZE
Offset-Druck
NE
IG
R
L
S A
N
DE D
Asia Japan
SCHILLER Asia-Pacific / Malaysia SCHILLER Japan, Ltd.
52200 Kuala Lumpur, Malaysia Hiroshima 734-8551
Phone +603 6272 3033 Phone +81 82 250 2055
Fax +603 6272 2030 Fax +81 82 253 1713
sales@schiller.com.my koji.maekawa@schiller.jp
www.schiller-asia.com www.schiller.jp
Austria Poland
SCHILLER Handelsgesellschaft m.b.H. SCHILLER Poland Sp. z o.o.
A-4040 Linz PL-02-729 Warszawa
Phone +43 732 709 90 Phone +48 22 8432089
Fax +43 732 757 000 Fax +48 22 8432089
sales@schiller.at schiller@schiller.pl
www.schiller.at www.schiller.pl
France Spain
SCHILLER Médical S.A.S. SCHILLER ESPAÑA, S.A.
F-67162 Wissembourg/Cedex E-28230-Las Rozas/Madrid
Phone +33 3 88 63 36 00 Phone +34 91 713 01 76
Fax +33 3 88 94 12 82 Fax +34 91 355 79 33
info@schiller.fr schiller@schiller.es
www.schiller-medical.com www.schiller.es
Germany Turkey
SCHILLER Medizintechnik GmbH SCHILLER TÜRKIYE
D-85521 Ottobrunn Okmeydani-Sisli – Istanbul
Phone +49 89 62 99 81-0 Phone +90 212 210 8681 (pbx)
Fax +49 89 609 50 90 Fax +90 212 210 8684
info@schillermed.de info@schiller.com.tr
www.schillermed.de www.schiller-turkiye.com
Hungary USA
SCHILLER Diamed Ltd. SCHILLER America Inc.
H-1141 Budapest Doral, Florida 33122
Phone +36 (1) 383-4780 / 460-9491 Phone +1 786 845 0620
Fax +36 (1) 383-4778 Fax +1 786 845 06 02
sales@schiller.at sales@schilleramerica.com
www.schilleramerica.com
www.schiller-hungary.hu
India
SCHILLER Healthcare India Pvt. Ltd.
Mumbai - 400 001, India
07/09
sales@schillerindia.com
www.schillerindia.com
Part no.: 2.500222
Headquarters: SCHILLER AG, Altgasse 68, CH-6341 Baar, Switzerland, Phone +41 41 766 42 42, Fax +41 41 761 08 80, sales@schiller.ch, www.schiller.ch