SCOPE:
Turning on and shutting down blue portable generator.
TOOLS:
HAZARDS:
Moving parts, flammable fuel, electrical, pinch points
SAFETY ITEMS:
2. Check oil level before starting. If oil is needed use Guardal 10-40 motor oil, 20 fluid oz. fills the crank case.
3. Check fuel level. If fuel is needed be sure the generator is off and cool before filling. Use only unleaded 87 octane gas.
7. Turn the key to START. Engine should crank and start. At this time move choke lever to the full open position. Allow engine to warm up.
8. At this point a tool cord or extension cord can be plugged into the generator for operation, using the appropriate outlet. Switch the circuit
breaker to the ON position.
9. To shut down the generator: turn OFF the circuit breaker and allow engine generator to idle for cool down. Turn the fuel cock to the OFF
position while the engine is still running. This will allow the engine generator to continue running for a short time for cool down and will shut
down when the fuel runs out. This procedure prevents fuel from sitting in the carburetor bowl for extended periods of time and possibly
damaging the equipment.
11. Remove key and return to Admin. room 108, lock box 2.
Fueling Fire , Chemical Burns Be sure generator is off and cool prior to refueling. Refuel at least 25
1.
feet from possible ignition sources (heat, flame, sparks).
Checking oil Burns, chemical spills Allow engine to cool prior to checking oil. Be sure generator is situated
2.
on a level surface prior to removing oil cap.
Transporting generator Muscle strain Use straps, crane or get assistance when attempting to lift generator.
3(a)
Transporting generator Leaking of hazardous material Be sure generator is transported and stored in an upright position and
3(b)
that the fuel and oil caps are secured.
Transporting generator Damage Be sure generator is properly secured prior to transport to minimize
3(c)
the potential for damage to the equipment.