center = 00:56:38.0N 118:17:02.7E

-20

SAA093 MT_SKP_SKL
kilometers

SAA020 SANDARAN

20

Cambium Networks - LINKPlanner


-40 -20 0 20 40
kilometers

27 August 2019 1
LINKPlanner version 4.9.0 Proposal Report
Project Untitled 1

Project Summary

Project: Untitled 1

General Information
Customer Name
Company Name
Address
Phone
Cell Phone
Email

27 August 2019 2
LINKPlanner version 4.9.0 Proposal Report
Project Untitled 1

SAA020 SANDARAN to
SAA093 MT_SKP_SKL
Equipment: Cambium Networks PTP670 Connectorized
Cambium Networks 4ft Dual-Polar Parabolic Cambium Networks 4ft Dual-Polar Parabolic
RDH4505 @ 68 m RDH4505 @ 68 m

SAA020 SANDARAN SAA093 MT_SKP_SKL


Height Above Sea Level (meters)

Height Above Sea Level (meters)


130 130
120 120
110 110
100 100
90 90
80 80
70 70
60 60
50 50
40 40
30 30
20 20
10 Cambium Networks - LINKPlanner 10
0 0
2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5 30 32.5 35 37.5 40 42.5 45 47.5
Range on path (kilometers)

Performance to SAA020 SANDARAN Performance to SAA093 MT_SKP_SKL


Mean IP 15.1 Mbps 15.1 Mbps
IP Availability 99.7504 % for 1.0 Mbps 99.7504 % for 1.0 Mbps

Link Summary
Link Length 48.884 km System Gain 186.42 dB
Band 5.8 GHz System Gain Margin 11.25 dB
Regulation Other Mean Aggregate Data Rate 30.2 Mbps
Modulation Adaptive Annual Link Availability 99.7504 %
Bandwidth 20 MHz Annual Link Unavailability 21.9 hrs/year
Total Path Loss 175.17 dB Prediction Model ITU-R

27 August 2019 3
LINKPlanner version 4.9.0 Proposal Report
Project Untitled 1

Performance Charts

Performance to SAA020 SANDARAN Performance to SAA093 MT_SKP_SKL


99.9% 99.9%

99.0% 99.0%
Availability

Availability
90.0% 90.0%

0.0% 0.0%
0 20 40 60 80 100 120 140 160 0 20 40 60 80 100 120 140 160
Capacity (Mbps) Capacity (Mbps)

High Capacity, assumes there is no load in the other direction

Symmetrical Capacity, assumes a saturated load in the other direction

Climatic Factors, Losses and Standards


dN/dH not exceeded for 1% -190.22 N Gaseous Absorption
of time units/km Loss 0.59 dB
Area roughness 110x110km 108.74 metre Link Type Non Line-of-Sight
Geoclimatic factor 6.54e-05 Excess Path Loss 33.09 dB
Fade Occurrence Factor (P0) 1.12e-01 Atmospheric Gasses ITU-R P.676-7, ITU-R P.835-4
Path inclination 1.01 mr Diffraction Loss ITU-R P.526-10
Value of K Exceeded for
99.99% (ke) 0.80 Propagation ITU-R P.530-12
Excess Path Loss at ke 45.51 dB Rain Rate ITU-R P.837-5
0.01% Rain rate 94.55 mm/hr Refractivity Index ITU-R P.453-9
Free Space Path Loss 141.50 dB

Bill of Materials
Part Number Qty Description
01010419001 12 Coaxial Cable Grounding Kits for 1/4" and 3/8" Cable

C000065L007 2 LPU and Grounding Kit (1 kit per ODU)


C050067H014 2 PTP 670 Connectorized END with AC+DC Enhanced Supply (ROW - EU Line
Cord).
Kit includes ODU, power supply, mounting bracket and EU line cord
EW-E4PT6XX-WW 2 PTP 650/670 Extended Warranty, 4 additional years (per END)
RDH4505 2 5.25-5.85 GHZ, 4-FT (1.2M), DUAL-POL, H-POL & V-POL

WB3176 2 328 ft (100 m) Reel Outdoor Copper Clad CAT5E (Recommended for PTP)

27 August 2019 4
LINKPlanner version 4.9.0 Proposal Report
Project Untitled 1

Cambium Networks assumes no responsibility for the accuracy of the information produced by the Cambium LINKPlanner. Reference to
products or services which are not provided by Cambium Networks is for information purposes only and constitutes neither an endorsement
nor a recommendation. All information provided by the Cambium LINKPlanner is provided without warranty of any kind, either expressed or
implied.

All product or service names are the property of their respective owners. © Cambium Networks. 2019

27 August 2019 5
LINKPlanner version 4.9.0 Proposal Report

Das könnte Ihnen auch gefallen