Sie sind auf Seite 1von 1

1. Packing list • Built in buzzer 6. Wiring 9.

Anti Tamper Alarm


Special Power Supply
• LED display the working status

INSTRUCTION Name
Digital Keypad K4-2
Quantity
1
Remark •

Two year warranty
Programmable Fail Safe or Fail Secure Operation
Colour Function Description
Wiegand Output D0 (or input from an D0 Green
J1
Exit Button Alarm
The K4-2 is built-in tamper switch. If the keypad is removed from the
cover then the tamper alarm will operate.

MANUAL Green D0 DC12V/3A


external reader)
User Manual 1 4. Specifications D1 White + - PUSH NC COM NO
10. Sound and Light indication
Wiegand Output D1 (or input from an
White D1 ALARM- Grey
Screwdriver 1 Operating Voltage 12V DC external reader)
OPEN Yellow Operation Status Red Light Green Light Buzzer
Pastern Stopper 4 6*25mm, used for fixing User Capacity Grey Alarm - Alarm Negative Door Detecting Switch
2000 Power on - Bright Short Ring

Fail-securelock
Yellow OPEN Request to Exit Button D_IN Brown
Self-tapping Screws 4 4*25mm, used for fixing Keypad 12 keys - -
Stand by Slow Flash
Brown D-In Door Contact +12V Red
- -

Fail-safe lock
Please ensure that all the above contents are correct. If any are Card Type EM 125 HZ card Press keypad Short Ring
Red 12V + 12V + DC Regulated Power Input GND Black
missing please notify the supplier of the K4-2. Card Reading Distance Operation successful - Bright Short Ring
3-6 cm VSS Blue
Black GND 0V DC Regulated Power Input Operation failed - - 3 Short Rings
2. Description Active Current <60mA L- Purple
Common 0V rail for the REX and Enter into
Blue VSS Bright - Short Ring
Idle Current 15±5 mA the door contact L+ Orange programming mode
The K4-2 is single door multifunction standalone access controller or ALARM+
Lock Output Load 3A Purple L- Lock Ground/Negative In the programming Bright Bright -
a Wiegand output keypad or card reader. The K4-2 supports up to mode
Orange L+/Alarm+ Lock and Alarm Positive When using special power supply, you need to set fail safe lock(unlock
2000 users in either a Card, 4 digit PIN, or a Card + PIN option. The Alarm Output Load 3A Exit from the
when power off) such as EM lock, Electronic Bolt lock etc. Reference 11.2 Slow Flash - Short Ring
inbuilt card reader supports EM, 125KHZ frequency cards. The K4-2 programming mode
Operating Temperature -40~60℃
has many extra features including an anti-magnetic MOS output, lock Open the door - Bright Short Ring
Operating Humidity 5%- 95% RH Connection Diagram
output current short circuit protection, a Wiegand input and output 7. Interface Circuits Alarm Quick Flash - Alarm
interface. These features make the K4-2 an ideal choice for door Adjustable Door Relay time 0 -99 seconds
access not only for small shops and domestic households but also for Common Power Supply Lock Interface Principle: Alarm Interface Principle:
Adjustable Alarm Time 0- 3 minutes By programme setting, I/O
+12V
when alarm, the I/O outputs high level. 11. Detailed Programming Guide
commercial and industrial applications such as factories, warehouses, K4-2
Wiegand Interface Wiegand 26 bit switch between low level and L+
laboratories, banks and prisons. J1 high level. D2 ALARM- 11.1 User Settings
4-low level
Electric Lock, Exit Button, DOTL, D0 Green Exit Button L-
I/O Q3
Wiring Connections Alarm 5-high level
* 888888 #
3. Features External Alarm DC12V/3A R8 To enter the programming
- I/O
D1 White + - Q2 mode 888888 is the default factory master
• Mini Access Controller Dimensions 50X120X27mm
+
R6 R13
R16 code
ALARM- Grey
• Full programming from the keypad N. W / G.W 100g / 250g To exit from the
OPEN Yellow programming mode *
• 2000 users, supports Card, PIN, Card + PIN
• Can be used as a stand alone keypad D_IN Brown The above diagrams show the output interface circuits. Unlike most Note that to undertake the following programming the master user
• Wiegand 26 input for the connection of an external reader 5. Installation Door Detecting Switch lock and alarm outputs which use a relay that can be shocked or must be logged in
+12V Red
• External readers can be any make of card reader with a 26 bit • Remove the back cover from the magnetized, the K4-2 uses MOS outputs for both the Lock Output To change the master code 0 New code # New code #
output, i.e. HID, Mifare, EM and so on GND Black on the left and the Alarm Output on the right. The master code can be 6 to 8 digits
keypad using the supplied security J1 long
• Wiegand 26 output for connection to a controller screwdriver
Wiring Cable Hamess
VSS Blue

ALARM+

ALARM-
D_IN

OPEN
+12V
L+

GND
VSS
L-

D1

D0
8. To Reset to Factory Default Setting the working mode: 3 0 # Entry is by card only

Orange

Purple

Blue

Black

Red

Brown

Yellow

Grey

White

Green
• Dual K4-2 units can interconnected and interlocked • Drill 4 holes on the wall for the screws L- Purple - Set valid card only users 3 1 # Entry is by card and PIN
• One programmable MOS output and 1 hole for the cable L+
Lock Set valid card and PIN users together
Orange + To reset to factory default, power off, press the RESET key(K2 ) on
• Adjustable Door Output time, Alarm time, Door Open time ALARM+

NVM Reset switch


• Fix the back cover firmly on the wall Set valid card or PIN users 3 2 # Entry is by either card or
Door power setting: You can choose between the PCB, hold it and power on, release it until hear three beeps
• Anti-magnetic MOS output with 4 flat head screws
TAMPER SWITCH

PIN (default)

K4-2
K1

fail secure and fail safe lock. Reference 11.2


K2

means reset to factory default successfully.


• Lock output current short circuit protection • Thread the cable through the cable hole PCB Connect Diagram Remarks: Reset to factory default, the user’s information is still To set a user in either card or PIN mode. (Default setting 3 2 # ).
• Easy to install and program • Attach the keypad to the back cover. retained.
Standalone Access Control • Built in Tamper Switch for anti-demolition

1 2 3 4 5

Fail safe (unlocked when 12.3 Two K4-2 units interconnected for a single door 12.4 Two K4-2 units interconnected & interlocked for 2 doors
1 User ID number # PIN # To Add a Card and Pin user Add the card as for a card user * Master code # 5 1~99 # * Door Interlock.
power is off) This is the In this mode two K4-2 units are used for a single door, one for entry In this mode two K4-2 units are used for a two doors which are then
The ID number is any number (The PIN is any four digits Press * to exit from the 1-99 is to set the door relay time 8 0 # (Factory default setting)
factory default, 5 seconds: 1-99 seconds Door interlock disabled and the other for exit. Either device acts as the controller and reader interconnected and interlocked. In this mode the doors can be
between 1 & 2000. The PIN is any between 0000 & 9999 with programming mode
the exception of 1234 which Then allocate the card a PIN as Door interlock enabled 8 1 # at the same time. Users can be enrolled on either of the devices. In interlocked so that when door 1 is open, door 2 cannot be opened,
four digits between 0000 & 9999 with Door Open Detection
is reserved.) follows: * Read card 1234 # this mode the user capacity for one door can be up to 4000. The and vise versa. The interlocked function is mainly used in banks,
To add a Pin user the exception of 1234 which is Door Open Too Long (DOTL) warning. When used with an
PIN # PIN # setting of the two K4-2 units must be the same including the master prisons, and other places where a higher level of security is required.
reserved. Users can be added optional magnetic contact or built-in magnetic contact of the lock,
continuously without exiting 12. Advanced Applications code. See figure 3. See figure 4
To change a PIN in card if the door is opened normally, but not closed after 1 minute, the
programming mode as follows: inside buzzer will beep automatically to remind people to close the Power

ALARM-
and PIN mode (Method 1) 12.1 Operating as a Wiegand Output Reader

OPEN
wiegand reader

ALARM+
DC12V/3A

+12V
D_IN

GND
1 User ID no 1 # PIN # door and continue for 1 minute before switching off automatically. K4-2 controller

VSS
K4-2 Controller 2

L+

Type of lock setting: do door relay setting according to the type of lock connected (fail safe or fail secure lock).
Note that this is done * Read Card Old PIN # New PIN # + -

D0
D1
Em card
In this mode the K4-2 supports a Wiegand 26 bit output so the GND

L-
User ID no 2 # PIN # J1
IC card
outside programming mode New PIN # Wiegand data lines can be connected to any controller which
+12V HID card

so the user can undertake Door Forced Open warning. When used with an optional magnetic D0 Green
D0
2 User ID number # contact or built-in magnetic contact of the lock, if the door is forced supports a Wiegand 26 bit input. See figure 1. D1

this themselves White Reader Plug

Red
Green

Brown
White

Blue

Orange
D1

Purple
Grey
Yellow

Black
To Delete a Pin user Users can be deleted continuously open, or if the door is opened after 20 seconds of the

J1
Grey -
ALARM-
without exiting programming mode electro-mechanical lock not closed properly, the inside buzzer and
To change a PIN in card OPEN Yellow +

alarm output will both operate. The Alarm Output time is adjustable J1
To change the PIN of a PIN and PIN mode (Method 2) Alarm

Door 2
Brown
user (This step must be done * ID number # Old PIN #

Door Detecting Switch 2


D_IN
Note that this is done * ID number # Old PIN # between 0-3 minutes with the default being 1 minute. D0 Green D0 Door Detecting Switch Exit Button
New PIN # New PIN # +12V Red
out of programming mode) outside programming New PIN # New PIN # D1 White D1
To disable door open GND Black
To add a Card user (Method mode so the user can 6 0 # Grey ALARM-
detection. (Factory default) VSS Blue
undertake this themselves +12V

Exit Button 2
1) This is the fastest way to Yellow OPEN L- Purple
1 Read Card # To enable door open -
enter cards using ID number To delete a Card and PIN GND Lock

+
Cards can be added continuously 6 1 # Brown D_IN L+ Orange
2 Read Card # or 2 User ID # detection ALARM+ +

Lock 2
auto generation. The ID user just delete the card
without exiting programming mode Red +12V
number will start from1, if no Alarm output time Controller Type of lock setting: do door relay setting according to the type of
To set a Card user in card mode ( 3 0 # ) Black GND

Alarm 2
user has been programmed.

+
-
Powerful lock connected (fail safe or fail secure lock). Reference 11.2
The operating is the same as To set the alarm output time supply
To Add and Delete a Card Blue VSS
Figure 2

DC12V/3A
To add a Card user (Method adding and deleting a card user in (0-3 minutes) Factory default is 9 0~3 #
user + Purple L-

Power

-
2) This is the alternative way 3 2 # 1 minute

Lock 1
Orange L+
to enter cards using User ID -

+
ALARM+
To delete ALL users. Keypad Lockout & Alarm Output options. If there are 10 invalid
Allocation. In this method a 1 ID number # Card # cards or 10 incorrect PIN numbers in a 10 minute period either the indoor
Power outdoor
User ID is allocated to a The ID number is any digit between To delete ALL users. Note Controller with wiegand 26 input K4-2 DC12V/3A

Alarm 1
keypad will lockout for 10 minutes or the alarm will operate for 10 J1

+
+ -

-
J1
card number. Only one user 1-2000. that this is a dangerous 2 0000 # minutes, depending on the option selected below. D0 Green
Green D0

+
-
ID can be allocated to a option so use with care Figure 1 White D1
D1 White
Normal status: No keypad

Exit Button 1
single card. Grey
- Grey ALARM-
To unlock the door lockout or alarm (factory 7 0 # (Factory default setting)
ALARM-
+
OPEN Yellow Yellow OPEN
To delete a Card user by default) 12.2 Operating as a Controller

Door Detecting Switch 1


Alarm
Enter the PIN then press #

Door 1
For a PIN user D_IN Brown Brown D_IN
card number. Note users Keypad Lockout In this mode the K4-2 supports a Wiegand 26 bit input so an external Door Detecting Switch Exit Button
Red
For a Card User Read card 7 1 # +12V Red +12V
can be deleted continuously 2 Read Card # Wiegand device with a 26 bit output can be connected to the Wiegand GND Black Black GND
without exiting programming For a Card and PIN user Read card then enter PIN # Alarm Output 7 2 # input terminals on the K4-2. Either an ID card reader (125 KHZ) or an VSS Blue Blue VSS

Orange
Brown
Green
K4-2 Controller 1

Purple
White

Yellow

Black
mode

Reference 11.2
Grey

Blue
Purple Purple

J1
IC card reader (13.56MHZ) can be connected to the K4-2. Cards are L- L-

Red
-
To remove the alarm Lock
L+ Orange L+
To delete a Card user by 11.2 Door Settings required to be added at the external reader, except where an external ALARM+ + Orange
ALARM+
To remove the Door Forced
user ID. This option can be Lock Power Setting & Door relay time setting Open warning Read valid card or Master Code # EM reader is used, in this case cards can be added at either reader.
2 User ID # K4-2 controller 1 K4-2 controller 2
used when a user has lost

D1

D_IN
OPEN

GND
VSS
D0

L-
ALARM-

+12V
See figure 2.

ALARM+
* Master code # 4 0~99 # * To remove the Door Open Close the door or Read valid card or

L+
their card Fail Secure (unlocked Type of lock setting: do door relay setting according to the type of lock
0-99 is to set the door relay time Too Long warning Master Code # connected (fail safe or fail secure lock). Reference 11.2
To set a Card and PIN user in card and PIN mode ( 3 1 # ) when power is on)
0-99 seconds. 0 for 50mS
Figure 3 Figure 4

6 7 8 9 10 11

Das könnte Ihnen auch gefallen