Sie sind auf Seite 1von 10

Graduate Engineer Trainee

Test Paper
Electrical Engineering
Statement for Linked Answer Questions: 1 and 2
In the following network, the voltage magnitudes at all buses are equal to 1 pu,
the voltage phase angles are very small, and the line resistances are negligible. All
the line reactances are equal to j1W

Q. 1If the base impedance and the line-to line base voltage are 100 ohms and 100 kV respectively, then the real power in MW
delivered by the generator connected at the slack bus is :
(A) -10
(B) 0
(C) 10
(D) 20

Q. 2The voltage phase angles in rad at buses 2 and 3 are


(A) q2 =- 0.1, q3 =- 0.2
(B) q2 = 0, q3 =- 0.1
(C) q2 = 0.1, q3 = 0.1
(D) q2 = 0.1, q3 = 0.2

Q. 3 A two-phase load draws the following phase currents : i1(t) = Im sin(wt - f1), i2(t) = Im cos (wt - f2). These currents are balanced
if f1 is equal to.
(A) -f2
(B) f2
(C) (p/2 - f2)
(D) (p/2 + f2)

Q. 4 The figure shows a two-generator system applying a load of PD = 40MW, connected at bus 2.

The fuel cost of generators G1 and G2 are :


C1(PG1) = 10000 Rs/MWh and C2(PG2) = 12500 Rs/MWh and the loss in the line is Ploss(pu) 0.5PG1(pu),= 2 where the loss coefficient is
specified in pu on a 100MVA base. The most economic power generation schedule in MW is
(A) PG1 = 20,PG2 = 22
(B) PG1 = 22,PG2 = 20
(C) PG1 = 20,PG2 = 20
(D) PG1 = 0,PG2 = 40
Q. 5 A cylinder rotor generator delivers 0.5 pu power in the steady-state to an infinite
bus through a transmission line of reactance 0.5 pu. The generator no-load voltage
is 1.5 pu and the infinite bus voltage is 1 pu. The inertia constant of the generator
is 5MW-s/MVA and the generator reactance is 1 pu. The critical clearing angle,
in degrees, for a three-phase dead short circuit fault at the generator terminal is
(A) 53.5
(B) 60.2
(C) 70.8
(D) 79.6

Q. 6Match the items in List-I (Type of transmission line) with the items in List-II
(Type of distance relay preferred) and select the correct answer using the codes
given below the lists.

List-I List-II
a. Short Line 1. Ohm Relay
b. Medium Line 2. Reactance Relay
c. Long Line 3. Mho Relay

(A) a " 2, b " 1, c " 3


(B) a " 3, b " 2, c " 1
(C) a " 1, b " 2, c " 3
(D) a " 1, b " 3, c " 2

Q. 7 A 500 MW, 21 kV, 50 Hz, 3-phase, 2-pole synchronous generator having a rated
p.f = 0.9, has a moment of inertia of 27.5 103 # kg-m2 .The inertia constant (H
) will be
(A) 2.44 s
(B) 2.71 s
(C) 4.88 s
(D) 5.42 s

Q. 8 Three generators are feeding a load of 100 MW. The details of the generators are

In the event of increased load power demand, which of the following will happen ?
(A) All the generator will share equal power
(B) Generator-3 will share more power compared to Generator-1
(C) Generator-1 will share more power compared to Generator-2
(D) Generator-2 will share more power compared to Generator-3

Q. 9 An extra high voltage transmission line of length 300 km can be approximate by a lossless line having propagation constant
b = 0.00127 radians per km. Then the percentage ratio of line length to wavelength will be given by
(A) 24.24 %
(B) 12.12 %
(C) 19.05 %
(D) 6.06 %

Q. 10A loss less transmission line having Surge Impedance Loading (SIL) of 2280 MW is provided with a uniformly distributed
series capacitive compensation of 30%. Then, SIL of the compensated transmission line will be
(A) 1835 MW
(B) 2280 MW
(C) 2725 MW
(D) 3257 MW
Q. 11

Q. 12

Q. 13

Q. 14

Q. 15

Q. 16

Q. 17
Q. 18

Q. 19

Q. 20

Q. 21

Q. 22

Q. 23

Q. 24

Q. 25
Q. 26

Q. 27

Q. 28

Q. 29

Q. 30

Q. 31

Q. 32
Q. 33

Q. 34

Q. 35

Q. 36

Q. 37

Q. 38
Q. 39

Q. 40

Q. 41

Q. 42

Q. 43

Q. 44
Q. 45

Q. 46

Q. 47

Q. 48

Q. 49

Q. 50
Q. 51

Q. 52

Q. 53

Q. 54

Q. 55

Q. 56
Q. 57

Q. 58

Q. 59

Q. 60

Das könnte Ihnen auch gefallen