PSS 5000 VRM Verification, Germany

Version 2.0

Installation and Test Guide

PUMP
ELECTRONICS

RS485 FAFNIR VPC


CONTROL
ELECTRONICS

SENSOR DEVICE

Date 27 May 2003


Document number PSS5000/TEGU/803376/01

Doms A/S Formervangen 28 Tel. +45 4329 9400 info@doms.dk


DK-2600 Glostrup Fax +45 4343 1012 www.doms.com
PSS 5000 VRM Verification, Germany
Installation and Test Guide, version 2.0

Table of Contents
1 Introduction ..................................................................................................... 3
2 References ....................................................................................................... 3
3 Installation and Setup ...................................................................................... 4
3.1 PSS 5000 .................................................................................................. 5
3.1.1 Configuration..................................................................................... 5
3.2 Local Optical and Acoustical Alarms....................................................... 6
3.3 Demo POS................................................................................................ 7
3.3.1 Configuration..................................................................................... 7
3.4 Configurator ............................................................................................. 7
4 Running the Verification Tools ....................................................................... 8
4.1 Demo POS................................................................................................ 8
4.1.1 Configure Forecourt .......................................................................... 8
4.1.2 Open Forecourt Devices .................................................................. 10
4.1.3 Self Service Mode ........................................................................... 11
4.1.4 Fuelling Point Error handling.......................................................... 13
4.1.5 Connection Lost after PSS 5000 Power Down................................ 14
4.2 PSS Configurator.................................................................................... 15
4.2.1 Configure VRM System.................................................................. 15
5 Verification Sessions ..................................................................................... 16
5.1 Evaluated Fillings................................................................................... 16
5.1.1 Various Vapour Recovery Rates (VRR) ......................................... 17
5.2 Fillings with VRC-box Error.................................................................. 22
5.3 Fillings with Alarm Box Error ............................................................... 25
5.4 “Time to Live with Error(s)” Error State................................................ 26
5.5 PSS Vapour Recovery Monitoring Data ................................................ 28
5.5.1 PSS Web Pages ............................................................................... 28
5.5.1.1 Vapour Recovery Monitoring Status........................................ 28
5.5.1.2 Online List ................................................................................ 28
5.5.1.3 Device Errors............................................................................ 29
5.5.2 PSS Local Service Panel ................................................................. 29
5.5.3 Status and Log Files ........................................................................ 29
6 Test and Reset Functions............................................................................... 30
7 Fp Error Codes (Reported to POS)................................................................ 33
History .............................................................................................................. 34

PSS5000/TEGU/803376/01 Page 2 of 34
PSS 5000 VRM Verification, Germany
Installation and Test Guide, version 2.0

1 Introduction
This document is describing the test and verification procedure used to verify
that the official German requirements, the so-called BlmSchV Rules,
regarding Vapour Recovery Monitoring, are complied with when using the
Doms PSS 5000 and FAFNIR VRC Boxes.

The test procedures can be used in an accept test session for the customer of
the PSS 5000 / VRC system.

2 References
VRM System Description: Doms Document SYSTEM/DESC/803308/04

PSS5000/TEGU/803376/01 Page 3 of 34
PSS 5000 VRM Verification, Germany
Installation and Test Guide, version 2.0

3 Installation and Setup

PUMP PSS 5000 BP/DOMS POS

HTTP SERVICE

VRC
DVRC

FUEL VAPOUR
4W XML STATISTICS

ALARM PANEL

Fig. 1 Equipment Involved in Vapour Recovery Monitoring

Tools and programs to be used are:


• PSS 5000 system with 1 VRM Alarm Panel
• PC with Web browser
• Demo POS for initialisation and Forecourt operation
• PSS Configurator for VRC initialisations
• TLT (Transport Level Tester), optional
• Real pump or Pump Simulator
• Real Vapour Recovery Controller or VRC Simulator

PSS5000/TEGU/803376/01 Page 4 of 34
PSS 5000 VRM Verification, Germany
Installation and Test Guide, version 2.0

3.1 PSS 5000

The VRM Alarm Panel should be connected to the PSS port 11 (default) via a
DSB451 module (Parallel I/O).

For port number of all other external devices: Please see PSS 5000 Application
Software Release Document (SRD).

Program modules are uploaded according to the PSS 5000 Technical Manual.

3.1.1 Configuration

The TCP/IP IP address of the PSS 5000 must set to a value given by the
network administrator.

To set the above mentioned TCP/IP parameters from the Local Service Panel
go to menu 2.3.1 and press <RIGHT> to display the current IP address and
proceed to the set-up menu’s.

TCP/IP IP ADDRESS USE DHCP?


2.3.1 Q 10.10.10.199 Q NO

Set USE DHCP=NO and set the IP address to the desired value using the
<UP> and <DOWN> buttons:

SET IP ADDRESS SET SUBNET MASK SET DEF. GATEWAY


10. 10. 10.101 Q 255.255.255.0 Q 10. 10. 10. 1

NEW SETUP
RESET NOW?

Finally press <OK> to perform the board reset, which activates the new
setting.

PSS5000/TEGU/803376/01 Page 5 of 34
PSS 5000 VRM Verification, Germany
Installation and Test Guide, version 2.0

3.2 Local Optical and Acoustical Alarms

Alarm Panel

The system must locally be equipped with an optical as well as an acoustical


alarm.

Alarms should be handled in two steps:

• first alert the operator and the remote system that something is wrong
with the vapour recovery system.

• second provide information regarding what is wrong.

Alarm functionality’s to be checked:

• Visual alarm:

o ON to indicate that everything is ok.


o FLASHING if the Vapour Recovery System has one or more
nozzles in error or disabled state.
o OFF indicates that there is a problem with the alarm panel or
its connections.

• Acoustical alarm:

o SOUND if the Vapour Recovery System has one or more


nozzles in error or disabled state.
o Switch for switching off the sound

PSS5000/TEGU/803376/01 Page 6 of 34
PSS 5000 VRM Verification, Germany
Installation and Test Guide, version 2.0

3.3 Demo POS

The PSS 5000 Windows Interface components are required for running the
Doms Demo POS

For installing the PSS 5000 Windows Interface components, run the setup
program:

Windows\PSS 5000 Interface Components\setup.exe

Follow the instructions on the screen.

For installing the Demo POS including User’s Guide and various ini-files, run
the Demo POS setup program:

Windows\DemoPOS\…\setup.exe

Follow the instructions on the screen.

IMPORTANT: If a Doms Demo POS is already installed, the existing Demo


POS must be un-installed before installing the new one: Go to the ‘Control
Panel… Add/Remove Programs… Remove ‘Doms Demo POS’.

3.3.1 Configuration

The actual site setup (physical devices connected to the PSS 5000 system) is
defined in the PSS5000_VRM.ini file.

• Grades (names etc)


• Prices
• Mode of running (ServiceModes, FullingModes etc)
• Pumps (number, products assigned etc)
• VRC assignments

3.4 Configurator

For installing the PSS Configurator, run the setup program:

Windows\PSS Configurator\setup.exe

Follow the instructions on the screen.

PSS5000/TEGU/803376/01 Page 7 of 34
PSS 5000 VRM Verification, Germany
Installation and Test Guide, version 2.0

4 Running the Verification Tools


4.1 Demo POS

The Demo POS is started from the start menu of your PC:

Start… Program Files… Doms PSS Demo POS

When prompted for Forecourt Logon: Select/Enter the IP address of the host =
the PSS 5000 and press ‘OK’

4.1.1 Configure Forecourt

From the Demo POS menu:


Actions… Special… Configure Forecourt

Fig. 2 Demo POS, Configure Forecourt

PSS5000/TEGU/803376/01 Page 8 of 34
PSS 5000 VRM Verification, Germany
Installation and Test Guide, version 2.0

Navigate/browse (‘…’-button) to the Forecourt configuration ini file (default


located in the Demo POS program folder). Select PSS5000_VRM.ini

Fig. 3 Demo POS Configurator, Configure Forecourt

Press ‘Configure’

Fig. 4 Demo POS MasterReset FC

Press ‘Yes’ to MasterReset

When finished, close the Configurator: Press ‘Exit’


Return to Demo POS.

PSS5000/TEGU/803376/01 Page 9 of 34
PSS 5000 VRM Verification, Germany
Installation and Test Guide, version 2.0

4.1.2 Open Forecourt Devices

From the Demo POS menu:


Actions… Special… Open All Devices

Fig. 5 Demo POS, Open All Devices

Open All Devices:


Confirm: Press ‘Yes’

PSS5000/TEGU/803376/01 Page 10 of 34
PSS 5000 VRM Verification, Germany
Installation and Test Guide, version 2.0

4.1.3 Self Service Mode

Before a Self Service transaction can take place, the Fuelling Point (Pump)
must be PreAuthorized:

Fig. 6 Demo POS, Fuelling Point status Idle

To PreAuthorize a Fuelling Point:


• Select Fuelling Point (Fp 1 in this example)
• Press ‘Auth’ button to preauthorize the selected Fp
• Fp 1 will now be Preauthorized like Fp 2

Make a Self Service transaction on pump 1 and the Demo POS will show the
transaction like below:

Fig. 7 Demo POS, One Current Transaction

PSS5000/TEGU/803376/01 Page 11 of 34
PSS 5000 VRM Verification, Germany
Installation and Test Guide, version 2.0

To clear the transaction, perform a Pay operation:


• Select the transaction to be paid in ‘Forecourt Overview’ pane
• Press ‘Add’ button to add the transaction to the receipt
• Select the transaction in the ‘Receipt’ pane
• Press ‘Sale OK’ for paying

Fig. 8 Demo POS, Transaction locked

Now the Fuelling Point status will return to either ‘Idle’ or ‘PreAuthorized’
depending on the ServiceMode being used.

PSS5000/TEGU/803376/01 Page 12 of 34
PSS 5000 VRM Verification, Germany
Installation and Test Guide, version 2.0

4.1.4 Fuelling Point Error handling

Fig. 9 Fuelling Error State

To Clear a Fuelling Point Error:


• Select Fuelling Point (Fp 3 in this example)
• Press ‘Clear Err.’ button to clear the error of the selected Fp

Fp 3 will now be back in Idle state like Fp 4

PSS5000/TEGU/803376/01 Page 13 of 34
PSS 5000 VRM Verification, Germany
Installation and Test Guide, version 2.0

4.1.5 Connection Lost after PSS 5000 Power Down

After a PSS 5000 power down, the connection from the Demo POS to the PSS
Forecourt will be lost.

To re-establish the connection, make a new Forecourt logon:

From the Demo POS Menu:


• Select Actions… Special… Forecourt Logon

Fig. 10 Demo POS, Manual Forecourt Logon

PSS5000/TEGU/803376/01 Page 14 of 34
PSS 5000 VRM Verification, Germany
Installation and Test Guide, version 2.0

4.2 PSS Configurator

The PSS Configurator is started from the start menu of your PC:

Start… Program Files… Doms PSS Configurator

4.2.1 Configure VRM System

The Configurator is used for additional configuring the VRM system.


Follow the instructions in the PSS Configurator User’s Guide.

PSS5000/TEGU/803376/01 Page 15 of 34
PSS 5000 VRM Verification, Germany
Installation and Test Guide, version 2.0

5 Verification Sessions
In the following test sessions the test results are checked as following:

• ‘PSS Web Menu 5.1.5.1. Vapour Recovery Monitor Test’ requires


login as User = “vrc” and password = ”password” (default).
• Vapour Recovery Errors on Nozzles are reported as Fuelling Point
Errors (FpError) to the POS system.
• Error counting is reported as ‘Consecutive unacceptable fillings’ on
‘PSS Web Menu 5.1.4.1 Vapour Recovery Monitor Status’ and in the
Site Status Log http://PssIpAddr/newevent.xml
• Evaluated Filling data is logged in the PSS event log
http://PssIpAddr/newevent.xml
• Alarm (Sound and light) is checked on the VRM Alarm panel
• Nozzle disabled is checked by observing if motor running on Pump
Simulator or real pump.

5.1 Evaluated Fillings

Only evaluated fillings are reported by the VRC box.

Definition:
An evaluated filling is a filling that:

• Lasts longer than 20 seconds


and
• Has a flow rate of min. 25 litre/minute

PSS5000/TEGU/803376/01 Page 16 of 34
PSS 5000 VRM Verification, Germany
Installation and Test Guide, version 2.0

5.1.1 Various Vapour Recovery Rates (VRR)

Purpose:
Verify, that
• All evaluated fillings must be logged in event log
• A Fuelling Point will enter a Vapour Recovery Error state when an
associated nozzle is meeting the specified error conditions
• Alarm (Acoustical as well as optical) activated

All fillings with unacceptable VRR must regardless of temperature be included


in the error counting.
The limited temperature range between +5C and +35C (both inclusive) is only
related to calibration of the VRC.
The temperature values used in the test cases are solely for having traceable
test data.

VRR OK :

• Create 1 filling with VRR = 100% and temp 20, and check that
o POS:
- No FpError
o PSS web menu 5.1.4.1 VRM Status:
- Nozzle x ‘Status’ OK
o Event log (newevent.xml):
- Check VRC filling data

VRR too low, Fp X:

• Create 1 filling with VRR = 70% and temp 21, and check that:
o POS:
- No FpError yet
o PSS web menu 5.1.4.1 VRM Status + site_sta.xml:
- Nozzle x ‘Status’ warning
- Consecutive unacceptable filling - counter is incremented
o Event log (newevent.xml):
- Check VRC filling data

• Create 9 similar fillings (same nozzle / grade), check that:


o POS:
- FpError 3x
o Pump:
- Temporary blocked. Another fuelling not possible
o Alarm panel:
- Flashing, Sound ON until switched OFF
o PSS web menu 5.1.4.1 VRM Status + site_sta.xml:
- Nozzle x ‘Status’ error
- Consecutive unacceptable fillings - counter is incremented
o Event log (newevent.xml):
- Check VRC filling data + FpError 3x

PSS5000/TEGU/803376/01 Page 17 of 34
PSS 5000 VRM Verification, Germany
Installation and Test Guide, version 2.0

• Clear FpError from POS, and check that


o POS:
- FpError is cleared
o PSS web menu 5.1.4.1 VRM Status,
- Nozzle x ‘Status’ error
- ‘Remaining operation’ set to 72 hours
o Alarm panel:
- Flashing
o Another fuelling possible

• Perform a ‘Reset VR counters for fuelling point’ using the password


protected PSS web menu 5.1.5.1 VRC Test, check that:
o PSS web menu 5.1.4.1 VRM Status + site_sta.xml,
- Nozzle x ‘Status’ is OK
o Alarm panel:
- No alarm

VRR too high, Fp X:

• Create 1 filling with VRR = 125% and temp 22, check that
o POS: No FpError yet
o PSS web menu 5.1.4.1 VRM Status + site_sta.xml:
- Nozzle x ‘Status’ warning
- Consecutive unacceptable filling - counter is incremented

• Create 9 similar fillings (same nozzle / grade), check that


o POS:
- FpError 3x
o Pump:
- Temporary blocked. Another fuelling not possible
o Alarm panel:
- Flashing, Sound ON until switched OFF

• Clear FpError from POS, and check that


o POS:
- FpError is cleared
o PSS web menu 5.1.4.1 VRM Status + site_sta.xml:
- Nozzle ‘Status’ error
- ‘Remaining operation’ set to 72 hours
o Alarm panel:
- Flashing
o Another fuelling possible

• Perform a ‘Reset VR counters for fuelling point’ using the password


protected PSS web menu 5.1.5.1 VRC Test.

PSS5000/TEGU/803376/01 Page 18 of 34
PSS 5000 VRM Verification, Germany
Installation and Test Guide, version 2.0

Fp X with 3 grades, Nozzle X, VRR to low:

• Create 1 (Nozzle X) filling with VRR = 80% and temp 11, check that
o POS:
- No FpError yet

• Create 9 similar fillings (same nozzle / grade) check that


o POS:
- FpError 3x
o Pump:
- Temporary blocked. Another fuelling not possible
o Alarm panel:
- Flashing, Sound ON until switched OFF

• Clear FpError from POS, and check that


o POS:
- FpError is cleared
o PSS web menu 5.1.4.1 VRM Status + site_sta.xml:
- Nozzle X ‘Status’ error
- ‘Remaining operation’ set to 72 hours
o Alarm panel:
- Flashing
o Another fuelling possible

Fp X with 3 grades, Nozzle Y, VRR too low:

• Create 1 (Nozzle Y) filling with VRR = 80% and temp 12, check that
o POS:
- No FpError yet

• Create 9 similar fillings (same nozzle / grade) check that


o POS:
- FpError 3y
o Pump:
- Temporary blocked. Another fuelling not possible
o Alarm panel:
- Flashing, Sound remains OFF

• Clear FpError from POS, and check that


o POS:
- FpError is cleared
o PSS web menu 5.1.4.1 VRM Status + site_sta.xml:
- Nozzle X and Y ‘Status’ error
- ‘Remaining operation’ set to 72 hours
o Alarm panel:
- Flashing
o Another fuelling possible

PSS5000/TEGU/803376/01 Page 19 of 34
PSS 5000 VRM Verification, Germany
Installation and Test Guide, version 2.0

Fp X with 3 grades, Nozzle Z, VRR too low:

• Create 1 (Nozzle Z) filling with VRR = 80% and temp 23, check that
o POS:
- No FpError yet
o PSS web menu 5.1.4.1 VRM Status + site_sta.xml:
- Nozzle Z ‘Status’ warning
- Consecutive unacceptable filling - counter is incremented

• Create 9 similar fillings (same nozzle / grade) check that


o POS:
- FpError 3z, check also
- no additional FpError 30 is reported
- Pump: Temporary blocked. Another fuelling not possible
o Alarm panel:
- Flashing, Sound remains OFF

• Clear FpError from POS, and check that


o POS:
- FpError is cleared
o PSS web menu 5.1.4.1 VRM Status:
- Nozzle X,Y and Z ‘Status’ error
- ‘Remaining operation’ set to 72 hours
o Alarm panel:
- Flashing
o Another fuelling possible

• Perform an ‘Reset VR counters for fuelling point’ using the password


protected PSS web menu 5.1.5.1 VRC Test, check that
o On PSS web menu 5.1.4.1 VRM Status:
- All Nozzle ‘Status’ is OK

PSS5000/TEGU/803376/01 Page 20 of 34
PSS 5000 VRM Verification, Germany
Installation and Test Guide, version 2.0

Non-consecutive bad fillings

• Create 5 fillings (with same nozzle) with VRR = 120% and temp 31.

• Create 1 good filling (with same nozzle) with VRR = 100% and
temp 32. Check that:
o PSS web menu 5.1.4.1 VRM Status + site_sta.xml:
- Nozzle x ‘Status’ OK

• Create 5 fillings (with same nozzle) with VRR = 120% and temp 33.
Check that:
o PSS web menu 5.1.4.1 VRM Status + site_sta.xml:
- Nozzle x ‘Status’ warning
- Consecutive unacceptable fillings - counter is incremented
o POS:
- No FpError

• Perform a ‘Reset VR counters for fuelling point’ using the password


protected PSS web menu 5.1.5.1 VRC Test.

PSS5000/TEGU/803376/01 Page 21 of 34
PSS 5000 VRM Verification, Germany
Installation and Test Guide, version 2.0

5.2 Fillings with VRC-box Error

Customer transactions generated when Vapour Recovery Box is in error states


must always be handled as fillings with unacceptable vapour recovery rate.

1a) Verification sessions with VRC-box online, but no evaluated data


delivered within 5 seconds after Pump Filling ended:1

• Pump transaction. Don’t create any VRC filling. Check that:


o PSS web menu 5.1.4.1 VRM Status + site_sta.xml:
- Nozzle x ‘Status’ Not evaluated
o POS:
- No FpError generated

1b) Verification sessions with VRC-box online, but evaluated data


delivered too late (unexpected):2

• Create 1 filling with VRR = 100% and temp 20. Check that:
o PSS web menu 5.1.4.1 VRM Status + site_sta.xml:
- Nozzle x ‘Status’ not evaluated
o POS:
- FpError 51:Unexpected VRC Filling

• Clear FpError. Check that :


o POS:
- FpError is cleared

• Authorize Fp for another fuelling. Check that:


o Pump:
- Motor can start again

2a) Verification sessions with VRC-box going offline:

• VRC going from online to offline. Check that:


o POS:
- All VRC assigned Fps: FpError 49: VRC Offline warning

• Clear FpError(s). Check that:


o POS:
- All VRC assigned Fps: FpError(s) are cleared

1
Test case might only be possible using VRC simulator or when using real VRC with a pump filling lasting less
than 20 secs or with a flow less than 25 litres/minutes.
2
Test case might only be possible using VRC simulator

PSS5000/TEGU/803376/01 Page 22 of 34
PSS 5000 VRM Verification, Germany
Installation and Test Guide, version 2.0

2b) Verification sessions with VRC-box being offline:

• Create 1 filling. Check that:


o PSS web menu 5.1.4.1 VRM Status + site_sta.xml:
- Nozzle x ‘Status’ warning
- Consecutive unacceptable fillings - counter is incremented
o POS:
- No FpError generated

• Perform a ‘Reset VR counters for fuelling point’ using the password


protected PSS web menu 5.1.5.1 VRC Test.

PSS5000/TEGU/803376/01 Page 23 of 34
PSS 5000 VRM Verification, Germany
Installation and Test Guide, version 2.0

3a) Verification sessions when VRC-Box going into Fatal error:

• Set VRC in Fatal error state (ID 108: Bit 0 = 1). Check that:
o POS:
- FpError 50: VRC Error warning

• Clear FpError. Check that:


o POS:
- FpError is cleared

3b) Verification sessions when VRC-Box reporting Fatal error:

• Create 1 filling with VRR = 100% and temp 20, VRC in error state.
Check that:
o PSS web menu 5.1.4.1 VRM Status + site_sta.xml:
- Nozzle X ‘Status’ warning
- Consecutive unacceptable filling - counter is incremented
o POS:
- No FpError yet

• Create 9 similar fillings (same nozzle / grade). Check that:


o POS:
- FpError 3x
o Pump:
- Temporary blocked. Another fuelling not possible
o Alarm Panel:
- Flashing. Sound ON until switched OFF

• Clear FpError. Check that:


o POS:
- FpError is cleared

• Perform a ‘Reset VR counters for fuelling point’ using the password


protected PSS web menu 5.1.5.1 VRC Test, check that:
o Pump:
- Not longer blocked.

PSS5000/TEGU/803376/01 Page 24 of 34
PSS 5000 VRM Verification, Germany
Installation and Test Guide, version 2.0

5.3 Fillings with Alarm Box Error

When the Alarm Box is offline or in an error state, all transactions should be
handled as VRC error transactions.

Verification session when Alarm-Box going from online to offline:

• Disconnect DIO module DSB451 (Remove DSB cable between PSS


5000 and HIM module). Check that:
o POS:
- All VRC assigned Fps: FpError 52: VR Alarm Panel Offline
warning

• Clear all VRC assigned Fps FpError(s). Check that


o POS:
- All FpError(s) are cleared

• Authorize Fp for another fuelling. Check that:


o Pump:
- Motor can be starting immediately

Verification sessions when Alarm-Box offline or in error:

• Create 1 filling with VRR = 100% and temp 20. Check that:
o PSS web menu 5.1.4.1 VRM Status + site_sta.xml:
- Nozzle X ‘Status’ warning
- Consecutive unacceptable filling - counter is incremented
o POS:
- No FpError yet

• Create 9 similar fillings (same nozzle / grade). Check that:


o POS:
- FpError 3x
o Pump:
- Temporary blocked. Another fuelling not possible
o Alarm Panel:
- Light OFF. Sound OFF

• Clear FpError. Check that:


o POS:
- FpError is cleared

• Perform a ‘Reset VR counters for fuelling point’ using the password


protected PSS web menu 5.1.5.1 VRC Test. Check that:
o Pump:
- Not longer blocked.

PSS5000/TEGU/803376/01 Page 25 of 34
PSS 5000 VRM Verification, Germany
Installation and Test Guide, version 2.0

5.4 “Time to Live with Error(s)” Error State

If a Vapour Recovery Error state has lasted more than the time specified as
‘Time to Live with Error(s)’ (Default 72 hours), the nozzle must be disabled.

• Create 10 fillings (same nozzle / grade) with VRR = 72% and temp =
20. Check that:
o POS:
- FpError 3x
o Pump:
- Temporary blocked. Another fuelling not possible

• Clear FpError. Check that:


o POS:
- FpError is cleared
o Pump:
- Another fuelling possible

• Wait 72 hours (or the time configured as ‘Time to Live with Error(s)’).
Check that:
o The nozzle is disabled (with and without clearing the
generated FpError):

• Using the defective nozzle for another filling. Check that:


o Pump: Filling not possible
o PSS web menu 5.1.4.1 VRM Status + site_sta.xml:
- Nozzle X ‘Status’ Disabled

Hastening the ‘Time to Live with Error(s)’_state can be simulated using the
password protected Service Menu:
Simulate ‘Time to Live with Error(s)’ timeout. See System Test Facilities.

• Perform a ‘Reset VR counters for fuelling point’ using the password


protected PSS web menu 5.1.5.1 VRC Test, check that:
o Pump: Using the prior defective nozzle for another filling
again possible
o PSS web menu 5.1.4.1 VRM Status + site_sta.xml:
- Nozzle X ‘Status’ OK

PSS5000/TEGU/803376/01 Page 26 of 34
PSS 5000 VRM Verification, Germany
Installation and Test Guide, version 2.0

With special VRM System Configuration (VccInterfaceType option):


Any nozzle in error => All nozzles disabled when ‘Time with Nozzle
Error(s)’ reached

VRR too low:

• Create 1 (Nozzle X) filling with VRR = 70% and temp 20, check that
o POS:
- No FpError yet
o PSS web menu 5.1.4.1 VRM Status + site_sta.xml:
- Nozzle X ‘Status’ warning
- Consecutive unacceptable filling - counter is incremented

• Create 9 similar fillings (same nozzle / grade) check that


o POS:
- FpError 3x
o Pump:
- Is blocked
o Alarm panel:
- Flashing, Sound ON until switched OFF

• Clear FpError from POS, and check that


o POS:
- FpError is cleared
o PSS web menu 5.1.4.1 VRM Status:
- Nozzle X ‘Status’ error
- ‘Remaining operation’ set to ‘Time with Nozzle Error(s)’
(default 72 hours) for all nozzles
o Alarm panel:
- Flashing

Another fuelling possible

• Await ‘Time with Nozzle Error(s)’ reached, and check


o POS:
- FpError 40 (Can’t be cleared before VR repaired)
o Pump:
- The nozzle disabled

• Perform a ‘Reset VR counters for fuelling point’ using the password


protected PSS web menu 5.1.5.1 VRC Test, check that:
o Site_sta.xml:
- Nozzle ‘Status’ is OK
o Alarm Panel:
- No alarm

PSS5000/TEGU/803376/01 Page 27 of 34
PSS 5000 VRM Verification, Germany
Installation and Test Guide, version 2.0

5.5 PSS Vapour Recovery Monitoring Data

Diagnostic information regarding the vapour recovery system should be


available:

• via PSS Web Pages,


• as XML formatted status and log files.

5.5.1 PSS Web Pages

Available information should be:

• Vapour recovery Monitoring Status


• Online List
• Device Errors

5.5.1.1 Vapour Recovery Monitoring Status

Vapour Recovery Monitoring Status (Menu 5.1.4.1):

VRM System:
• Status

VRM Controller:
• Serial Number
• Hardware version
• Firmware version
• Protocol Version
• Online
• State
• Pulser Rate

VRM Fuelling Point:


• Maintenance mode
• Start of counting (date)
• Specific Nozzle Info
o Status
o Remaining operation (when in error state)
o Consecutive unacceptable fillings
o Latest Recovery Rate
o Latest Fuel Flow
o Latest temperature

5.5.1.2 Online List

PSS Menu 5.1.1:


All devices detected online should be listed

PSS5000/TEGU/803376/01 Page 28 of 34
PSS 5000 VRM Verification, Germany
Installation and Test Guide, version 2.0

5.5.1.3 Device Errors

PSS Menu 5.1.2:


• Fuelling Point Errors
• VRC Errors

5.5.2 PSS Local Service Panel

• Online List
• Device Errors

5.5.3 Status and Log Files

XML formatted status and log can be viewed with an Internet browser:

http://PssIpAddr/site_sta.xml
http://PssIpAddr/newevent.xml

XML formatted status and event log files could be requested via TCP/IP.

The content of the XML formatted file is the similar to the Web based status.

PSS5000/TEGU/803376/01 Page 29 of 34
PSS 5000 VRM Verification, Germany
Installation and Test Guide, version 2.0

6 Test and Reset Functions


Test and reset functions can be accesses via a password protected menu of the
PSS system (Menu 5.1.5.1):

None

Reset VR counters for fuelling point

Suspend disabling of fuelling point

Simulate VR error on fuelling point


Simulate VR disabling of fuelling
point
Simulate VR disabling of nozzle 1

Simulate VR disabling of nozzle 2

Time to live with error(s) for entire VRM system: |72| hours

Check each function listed in the ‘Test and Reset’ table.

• Time To Live with Error(s) using PSS system (Menu 5.1.5.1):


Check:
o Reduced time values during test below

• Simulate VR error on fuelling point using PSS system (Menu


5.1.5.1): Check that:
o POS:
- FpError 30
o Pump:
- Temporary blocked. Another fuelling not possible
o Alarm Panel:
- Flashing. Sound ON until switched OFF.

• Clear FpError. Check that:


o POS:
- FpError is cleared

• Simulate VR disabling of fuelling point using PSS system (Menu


5.1.5.1): Check that:
o POS:
- FpError 40
o Pump:
- Blocked. Another fuelling not possible
o Alarm Panel:
- Flashing. Sound ON until switched OFF.

PSS5000/TEGU/803376/01 Page 30 of 34
PSS 5000 VRM Verification, Germany
Installation and Test Guide, version 2.0

• Try Clear FpError. Check that:


o POS:
- FpError is not cleared (still FpError 40)

• Set to None using PSS system (Menu 5.1.5.1).

• Clear FpError. Check that:


o POS:
- FpError is cleared

• Simulate VR disabling of nozzle x using PSS system (Menu


5.1.5.1):
o POS:
- FpError 4x
o Pump:
- Temporary blocked. Another fuelling not possible
o Alarm Panel:
- Flashing. Sound ON until switched OFF.

• Clear FpError. Check that:


o POS:
- FpError is cleared

• Set to None using PSS system (Menu 5.1.5.1)

• Simulate VR disabling of fuelling point using PSS system (Menu


5.1.5.1):
o Alarm Panel:
- Flashing. Sound ON until switched OFF.

• Suspend disabling of fuelling point using PSS system (Menu


5.1.5.1): Check that:
o POS:
- FpError 40
o Pump:
- Blocked. Another fuelling not possible
o Alarm Panel:
- Constant light. Sound still OFF

• POS: Clear FpError. Check that:


o POS:
- FpError is cleared
o Pump:
- Another filling possible

PSS5000/TEGU/803376/01 Page 31 of 34
PSS 5000 VRM Verification, Germany
Installation and Test Guide, version 2.0

• Make 10 fillings (same nozzle x) with VRR = 70% and temp 20.
• On Alarm Panel: Switch sound OFF
• On POS: Clear FpError.
• Await ‘Time To Live with Error(s). Check that:
o POS:
- FpError 4x

• Suspend disabling of fuelling point using PSS system (Menu


5.1.5.1): Check that:
o POS:
- FpError 40
o Pump:
- Blocked. Another fuelling not possible
o Alarm Panel:
- Constant light. Sound still OFF

• POS: Clear FpError. Check that:


o POS:
- FpError is cleared
o Pump:
- Another filling possible

• Perform a ‘Reset VR counters for fuelling point’ using the password


protected PSS web menu 5.1.5.1 VRC Test.

PSS5000/TEGU/803376/01 Page 32 of 34
PSS 5000 VRM Verification, Germany
Installation and Test Guide, version 2.0

7 Fp Error Codes (Reported to POS)


VRM errors are reported in two levels:

• After 10 consecutive fillings (same Fuelling Point, same nozzle)


FpErrorCode 3x is generated. This error can be cleared – and the Fp
will be operational for another ‘Time To Live With Error(s)’ Default
72 hours

• ‘Time To Live With Error(s)’ timeout (without repairing the VRC


device) FpErrorCode 4x is generated. This error code can be cleared –
but the nozzle will remain disabled.

FpErrorCode (DEC2)

/* Read when fuelling point is idle */


30: Vapour Recovery Error, all nozzles in error state
31: Vapour Recovery Error, nozzles 1 in error state
32: Vapour Recovery Error, nozzles 2 in error state
33: Vapour Recovery Error, nozzles 3 in error state
34: Vapour Recovery Error, nozzles 4 in error state
35: Vapour Recovery Error, nozzles 5 in error state
36: Vapour Recovery Error, nozzles 6 in error state
37: Vapour Recovery Error, nozzles 7 in error state
38: Vapour Recovery Error, nozzles 8 in error state

/* Read when fuelling point is idle */


40: Vapour Recovery Error, all nozzles disabled
41: Vapour Recovery Error, nozzles 1 disabled
42: Vapour Recovery Error, nozzles 2 disabled
43: Vapour Recovery Error, nozzles 3 disabled
44: Vapour Recovery Error, nozzles 4 disabled
45: Vapour Recovery Error, nozzles 5 disabled
46: Vapour Recovery Error, nozzles 6 disabled
47: Vapour Recovery Error, nozzles 7 disabled
48: Vapour Recovery Error, nozzles 8 disabled

/* Read when fuelling point is idle */


49: Vapour Recovery Controller Offline (Warning)
50: Vapour Recovery Controller Error (Warning)
51: Vapour Recovery Controller Unexpected Filling (Warning)
52: Vapour Recovery Alarm Panel Offline (Warning)

PSS5000/TEGU/803376/01 Page 33 of 34
PSS 5000 VRM Verification, Germany
Installation and Test Guide, version 2.0

History
Date Rev. Init. Comments
2003-04-04 00 JoJ First revision (Preliminary)
Major changes reflecting changed system specifications after first
2003-05-27 01 JoJ
test with Fafnir equipment.

PSS5000/TEGU/803376/01 Page 34 of 34