BUBBLE CAP TRAY SIZING


Vapor load is defined as the vapor from the tray below.
Liquid load is defined as the liquid on the tray.

Section: 1

Equip. 1 Tray No. 2

Tray Loadings Vapor Liquid


196.455 kg/h 137.717 kg/h
58.976 m3/h 0.172 m3/h
Density 0.208 lb/ft3 49.961 lb/ft3
Tower internal diameter, ft ................ 1.000
Tray spacing, ft ................ 1.500
No. of tray liquid passes ................ 1
Downcomer dimension Width ft Length ft Area ft2
Side 0.146 0.706 0.071
Avg. weir length ft ................ 0.706
Weir height, ft ................ 0.167
Flow path length ft ................ 0.708
Flow path width ft ................ 0.909
Tray area, ft2 ................ 0.785
Tray active area ft2 ................ 0.644
% flood ................ 20.258
No. of caps ................ 3
Fractional entrainment ................ 0.008
Aeration factor ................ 0.829
Tray press loss, ft ................ 0.096
Tray press loss, atm ................ 0.002
Downcomer clearance ft ................ 0.146
Downcomer backup ft ................ 0.272
Downcomer residence time sec ............... 11.406
Downcomer apparent residence time sec ..... 63.016
Downcomer velocity ft/sec ............ 0.024
Liquid holdup m3 ................ 0.001
Liquid holdup kg ................ 1.042
Design pressure atm ................ 1.000
Joint efficiency ................ 0.850
Allowable stress atm ................ 932.230
Corrosion allowance ft ................ 0.003
Column thickness ft ................ 0.000
Bottom thickness ft ................ 0.000

Equip. 1 Tray No. 3

Tray Loadings Vapor Liquid


182.623 kg/h 123.885 kg/h
56.884 m3/h 0.153 m3/h
Density 0.200 lb/ft3 50.579 lb/ft3
Tower internal diameter, ft ................ 0.500
Tray spacing, ft ................ 1.500
No. of tray liquid passes ................ 1
Downcomer dimension Width ft Length ft Area ft2
Side 0.089 0.382 0.024
Avg. weir length ft ................ 0.382
Weir height, ft ................ 0.167
Flow path length ft ................ 0.322
Flow path width ft ................ 0.463
Tray area, ft2 ................ 0.196
Tray active area ft2 ................ 0.149
% flood ................ 77.500
No. of caps ................ 1
Fractional entrainment ................ 0.089
Aeration factor ................ 0.630
Tray press loss, ft ................ 0.171
Tray press loss, atm ................ 0.004
Downcomer clearance ft ................ 0.146
Downcomer backup ft ................ 0.353
Downcomer residence time sec ............... 5.538
Downcomer apparent residence time sec ..... 23.563
Downcomer velocity ft/sec ............ 0.064
Liquid holdup m3 ................ 0.000
Liquid holdup kg ................ 0.309
Design pressure atm ................ 1.000
Joint efficiency ................ 0.850
Allowable stress atm ................ 932.230
Corrosion allowance ft ................ 0.003
Column thickness ft ................ 0.000
Bottom thickness ft ................ 0.000

Equip. 1 Tray No. 4

Tray Loadings Vapor Liquid


173.483 kg/h 114.745 kg/h
55.712 m3/h 0.140 m3/h
Density 0.194 lb/ft3 51.191 lb/ft3
Tower internal diameter, ft ................ 0.500
Tray spacing, ft ................ 1.500
No. of tray liquid passes ................ 1
Downcomer dimension Width ft Length ft Area ft2
Side 0.089 0.382 0.024
Avg. weir length ft ................ 0.382
Weir height, ft ................ 0.167
Flow path length ft ................ 0.322
Flow path width ft ................ 0.463
Tray area, ft2 ................ 0.196
Tray active area ft2 ................ 0.149
% flood ................ 73.029
No. of caps ................ 1
Fractional entrainment ................ 0.075
Aeration factor ................ 0.633
Tray press loss, ft ................ 0.165
Tray press loss, atm ................ 0.004
Downcomer clearance ft ................ 0.146
Downcomer backup ft ................ 0.345
Downcomer residence time sec ............... 5.927
Downcomer apparent residence time sec ..... 25.747
Downcomer velocity ft/sec ............ 0.058
Liquid holdup m3 ................ 0.000
Liquid holdup kg ................ 0.307
Design pressure atm ................ 1.000
Joint efficiency ................ 0.850
Allowable stress atm ................ 932.230
Corrosion allowance ft ................ 0.003
Column thickness ft ................ 0.000
Bottom thickness ft ................ 0.000

Equip. 1 Tray No. 5

Tray Loadings Vapor Liquid


171.054 kg/h 112.316 kg/h
55.715 m3/h 0.136 m3/h
Density 0.192 lb/ft3 51.397 lb/ft3
Tower internal diameter, ft ................ 0.500
Tray spacing, ft ................ 1.500
No. of tray liquid passes ................ 1
Downcomer dimension Width ft Length ft Area ft2
Side 0.089 0.382 0.024
Avg. weir length ft ................ 0.382
Weir height, ft ................ 0.167
Flow path length ft ................ 0.322
Flow path width ft ................ 0.463
Tray area, ft2 ................ 0.196
Tray active area ft2 ................ 0.149
% flood ................ 71.849
No. of caps ................ 1
Fractional entrainment ................ 0.072
Aeration factor ................ 0.634
Tray press loss, ft ................ 0.164
Tray press loss, atm ................ 0.004
Downcomer clearance ft ................ 0.146
Downcomer backup ft ................ 0.344
Downcomer residence time sec ............... 6.051
Downcomer apparent residence time sec ..... 26.410
Downcomer velocity ft/sec ............ 0.057
Liquid holdup m3 ................ 0.000
Liquid holdup kg ................ 0.307
Design pressure atm ................ 1.000
Joint efficiency ................ 0.850
Allowable stress atm ................ 932.230
Corrosion allowance ft ................ 0.003
Column thickness ft ................ 0.000
Bottom thickness ft ................ 0.000

Equip. 1 Tray No. 6

Tray Loadings Vapor Liquid


11404.506 kg/h 29953.281 kg/h
3756.904 m3/h 36.348 m3/h
Density 0.190 lb/ft3 51.445 lb/ft3
Tower internal diameter, ft ................ 4.500
Tray spacing, ft ................ 1.500
No. of tray liquid passes ................ 1
Downcomer dimension Width ft Length ft Area ft2
Side 0.833 3.496 2.028
Avg. weir length ft ................ 3.496
Weir height, ft ................ 0.167
Flow path length ft ................ 2.833
Flow path width ft ................ 4.182
Tray area, ft2 ................ 15.904
Tray active area ft2 ................ 11.849
% flood ................ 72.591
No. of caps ................ 74
Fractional entrainment ................ 0.002
Aeration factor ................ 0.652
Tray press loss, ft ................ 0.244
Tray press loss, atm ................ 0.006
Downcomer clearance ft ................ 0.146
Downcomer backup ft ................ 0.639
Downcomer residence time sec ............... 3.634
Downcomer apparent residence time sec ..... 8.531
Downcomer velocity ft/sec ............ 0.176
Liquid holdup m3 ................ 0.079
Liquid holdup kg ................ 65.265
Design pressure atm ................ 1.000
Joint efficiency ................ 0.850
Allowable stress atm ................ 932.230
Corrosion allowance ft ................ 0.003
Column thickness ft ................ 0.000
Bottom thickness ft ................ 0.000

Equip. 1 Tray No. 7

Tray Loadings Vapor Liquid


11506.409 kg/h 30055.186 kg/h
3835.607 m3/h 36.478 m3/h
Density 0.187 lb/ft3 51.436 lb/ft3
Tower internal diameter, ft ................ 4.500
Tray spacing, ft ................ 1.500
No. of tray liquid passes ................ 1
Downcomer dimension Width ft Length ft Area ft2
Side 0.833 3.496 2.028
Avg. weir length ft ................ 3.496
Weir height, ft ................ 0.167
Flow path length ft ................ 2.833
Flow path width ft ................ 4.182
Tray area, ft2 ................ 15.904
Tray active area ft2 ................ 11.849
% flood ................ 73.417
No. of caps ................ 74
Fractional entrainment ................ 0.002
Aeration factor ................ 0.650
Tray press loss, ft ................ 0.246
Tray press loss, atm ................ 0.006
Downcomer clearance ft ................ 0.146
Downcomer backup ft ................ 0.642
Downcomer residence time sec ............... 3.639
Downcomer apparent residence time sec ..... 8.501
Downcomer velocity ft/sec ............ 0.176
Liquid holdup m3 ................ 0.079
Liquid holdup kg ................ 65.416
Design pressure atm ................ 1.000
Joint efficiency ................ 0.850
Allowable stress atm ................ 932.230
Corrosion allowance ft ................ 0.003
Column thickness ft ................ 0.000
Bottom thickness ft ................ 0.000

Equip. 1 Tray No. 8

Tray Loadings Vapor Liquid


11678.734 kg/h 30227.510 kg/h
3932.706 m3/h 36.706 m3/h
Density 0.185 lb/ft3 51.410 lb/ft3
Tower internal diameter, ft ................ 4.500
Tray spacing, ft ................ 1.500
No. of tray liquid passes ................ 1
Downcomer dimension Width ft Length ft Area ft2
Side 0.833 3.496 2.028
Avg. weir length ft ................ 3.496
Weir height, ft ................ 0.167
Flow path length ft ................ 2.833
Flow path width ft ................ 4.182
Tray area, ft2 ................ 15.904
Tray active area ft2 ................ 11.849
% flood ................ 74.626
No. of caps ................ 74
Fractional entrainment ................ 0.002
Aeration factor ................ 0.648
Tray press loss, ft ................ 0.248
Tray press loss, atm ................ 0.006
Downcomer clearance ft ................ 0.146
Downcomer backup ft ................ 0.647
Downcomer residence time sec ............... 3.642
Downcomer apparent residence time sec ..... 8.448
Downcomer velocity ft/sec ............ 0.178
Liquid holdup m3 ................ 0.080
Liquid holdup kg ................ 65.654
Design pressure atm ................ 1.000
Joint efficiency ................ 0.850
Allowable stress atm ................ 932.230
Corrosion allowance ft ................ 0.003
Column thickness ft ................ 0.000
Bottom thickness ft ................ 0.000

Equip. 1 Tray No. 9

Tray Loadings Vapor Liquid


11870.000 kg/h 30418.770 kg/h
4026.241 m3/h 36.963 m3/h
Density 0.184 lb/ft3 51.375 lb/ft3
Tower internal diameter, ft ................ 4.500
Tray spacing, ft ................ 1.500
No. of tray liquid passes ................ 1
Downcomer dimension Width ft Length ft Area ft2
Side 0.833 3.496 2.028
Avg. weir length ft ................ 3.496
Weir height, ft ................ 0.167
Flow path length ft ................ 2.833
Flow path width ft ................ 4.182
Tray area, ft2 ................ 15.904
Tray active area ft2 ................ 11.849
% flood ................ 75.896
No. of caps ................ 74
Fractional entrainment ................ 0.003
Aeration factor ................ 0.645
Tray press loss, ft ................ 0.251
Tray press loss, atm ................ 0.006
Downcomer clearance ft ................ 0.146
Downcomer backup ft ................ 0.652
Downcomer residence time sec ............... 3.644
Downcomer apparent residence time sec ..... 8.389
Downcomer velocity ft/sec ............ 0.179
Liquid holdup m3 ................ 0.080
Liquid holdup kg ................ 65.914
Design pressure atm ................ 1.000
Joint efficiency ................ 0.850
Allowable stress atm ................ 932.230
Corrosion allowance ft ................ 0.003
Column thickness ft ................ 0.000
Bottom thickness ft ................ 0.000

Equip. 1 Tray No. 10

Tray Loadings Vapor Liquid


12028.254 kg/h 30577.000 kg/h
4098.512 m3/h 37.178 m3/h
Density 0.183 lb/ft3 51.344 lb/ft3
Tower internal diameter, ft ................ 4.500
Tray spacing, ft ................ 1.500
No. of tray liquid passes ................ 1
Downcomer dimension Width ft Length ft Area ft2
Side 0.833 3.496 2.028
Avg. weir length ft ................ 3.496
Weir height, ft ................ 0.167
Flow path length ft ................ 2.833
Flow path width ft ................ 4.182
Tray area, ft2 ................ 15.904
Tray active area ft2 ................ 11.849
% flood ................ 76.923
No. of caps ................ 74
Fractional entrainment ................ 0.003
Aeration factor ................ 0.644
Tray press loss, ft ................ 0.253
Tray press loss, atm ................ 0.006
Downcomer clearance ft ................ 0.146
Downcomer backup ft ................ 0.656
Downcomer residence time sec ............... 3.645
Downcomer apparent residence time sec ..... 8.341
Downcomer velocity ft/sec ............ 0.180
Liquid holdup m3 ................ 0.080
Liquid holdup kg ................ 66.129
Design pressure atm ................ 1.000
Joint efficiency ................ 0.850
Allowable stress atm ................ 932.230
Corrosion allowance ft ................ 0.003
Column thickness ft ................ 0.000
Bottom thickness ft ................ 0.000
Equip. 1 Tray No. 11

Tray Loadings Vapor Liquid


12135.461 kg/h 30684.240 kg/h
4145.828 m3/h 37.324 m3/h
Density 0.183 lb/ft3 51.323 lb/ft3
Tower internal diameter, ft ................ 4.500
Tray spacing, ft ................ 1.500
No. of tray liquid passes ................ 1
Downcomer dimension Width ft Length ft Area ft2
Side 0.833 3.496 2.028
Avg. weir length ft ................ 3.496
Weir height, ft ................ 0.167
Flow path length ft ................ 2.833
Flow path width ft ................ 4.182
Tray area, ft2 ................ 15.904
Tray active area ft2 ................ 11.849
% flood ................ 77.610
No. of caps ................ 74
Fractional entrainment ................ 0.003
Aeration factor ................ 0.643
Tray press loss, ft ................ 0.255
Tray press loss, atm ................ 0.006
Downcomer clearance ft ................ 0.146
Downcomer backup ft ................ 0.660
Downcomer residence time sec ............... 3.653
Downcomer apparent residence time sec ..... 8.308
Downcomer velocity ft/sec ............ 0.181
Liquid holdup m3 ................ 0.081
Liquid holdup kg ................ 66.434
Design pressure atm ................ 1.000
Joint efficiency ................ 0.850
Allowable stress atm ................ 932.230
Corrosion allowance ft ................ 0.003
Column thickness ft ................ 0.000
Bottom thickness ft ................ 0.000

Equip. 1 Tray No. 12

Tray Loadings Vapor Liquid


12199.476 kg/h 30748.254 kg/h
4173.604 m3/h 37.411 m3/h
Density 0.182 lb/ft3 51.310 lb/ft3
Tower internal diameter, ft ................ 4.500
Tray spacing, ft ................ 1.500
No. of tray liquid passes ................ 1
Downcomer dimension Width ft Length ft Area ft2
Side 0.833 3.496 2.028
Avg. weir length ft ................ 3.496
Weir height, ft ................ 0.167
Flow path length ft ................ 2.833
Flow path width ft ................ 4.182
Tray area, ft2 ................ 15.904
Tray active area ft2 ................ 11.849
% flood ................ 78.019
No. of caps ................ 74
Fractional entrainment ................ 0.003
Aeration factor ................ 0.642
Tray press loss, ft ................ 0.256
Tray press loss, atm ................ 0.006
Downcomer clearance ft ................ 0.146
Downcomer backup ft ................ 0.661
Downcomer residence time sec ............... 3.654
Downcomer apparent residence time sec ..... 8.289
Downcomer velocity ft/sec ............ 0.181
Liquid holdup m3 ................ 0.081
Liquid holdup kg ................ 66.525
Design pressure atm ................ 1.000
Joint efficiency ................ 0.850
Allowable stress atm ................ 932.230
Corrosion allowance ft ................ 0.003
Column thickness ft ................ 0.000
Bottom thickness ft ................ 0.000

Equip. 1 Tray No. 13

Tray Loadings Vapor Liquid


12235.056 kg/h 30783.832 kg/h
4188.906 m3/h 37.459 m3/h
Density 0.182 lb/ft3 51.303 lb/ft3
Tower internal diameter, ft ................ 4.500
Tray spacing, ft ................ 1.500
No. of tray liquid passes ................ 1
Downcomer dimension Width ft Length ft Area ft2
Side 0.833 3.496 2.028
Avg. weir length ft ................ 3.496
Weir height, ft ................ 0.167
Flow path length ft ................ 2.833
Flow path width ft ................ 4.182
Tray area, ft2 ................ 15.904
Tray active area ft2 ................ 11.849
% flood ................ 78.246
No. of caps ................ 74
Fractional entrainment ................ 0.004
Aeration factor ................ 0.641
Tray press loss, ft ................ 0.257
Tray press loss, atm ................ 0.006
Downcomer clearance ft ................ 0.146
Downcomer backup ft ................ 0.662
Downcomer residence time sec ............... 3.654
Downcomer apparent residence time sec ..... 8.278
Downcomer velocity ft/sec ............ 0.181
Liquid holdup m3 ................ 0.081
Liquid holdup kg ................ 66.579
Design pressure atm ................ 1.000
Joint efficiency ................ 0.850
Allowable stress atm ................ 932.230
Corrosion allowance ft ................ 0.003
Column thickness ft ................ 0.000
Bottom thickness ft ................ 0.000

Equip. 1 Tray No. 14

Tray Loadings Vapor Liquid


12254.021 kg/h 30802.799 kg/h
4197.030 m3/h 37.485 m3/h
Density 0.182 lb/ft3 51.299 lb/ft3
Tower internal diameter, ft ................ 4.500
Tray spacing, ft ................ 1.500
No. of tray liquid passes ................ 1
Downcomer dimension Width ft Length ft Area ft2
Side 0.833 3.496 2.028
Avg. weir length ft ................ 3.496
Weir height, ft ................ 0.167
Flow path length ft ................ 2.833
Flow path width ft ................ 4.182
Tray area, ft2 ................ 15.904
Tray active area ft2 ................ 11.849
% flood ................ 78.366
No. of caps ................ 74
Fractional entrainment ................ 0.004
Aeration factor ................ 0.641
Tray press loss, ft ................ 0.257
Tray press loss, atm ................ 0.006
Downcomer clearance ft ................ 0.146
Downcomer backup ft ................ 0.663
Downcomer residence time sec ............... 3.654
Downcomer apparent residence time sec ..... 8.272
Downcomer velocity ft/sec ............ 0.181
Liquid holdup m3 ................ 0.081
Liquid holdup kg ................ 66.608
Design pressure atm ................ 1.000
Joint efficiency ................ 0.850
Allowable stress atm ................ 932.230
Corrosion allowance ft ................ 0.003
Column thickness ft ................ 0.000
Bottom thickness ft ................ 0.000

Equip. 1 Tray No. 15

Tray Loadings Vapor Liquid


12263.808 kg/h 30812.586 kg/h
4201.219 m3/h 37.499 m3/h
Density 0.182 lb/ft3 51.297 lb/ft3
Tower internal diameter, ft ................ 4.500
Tray spacing, ft ................ 1.500
No. of tray liquid passes ................ 1
Downcomer dimension Width ft Length ft Area ft2
Side 0.833 3.496 2.028
Avg. weir length ft ................ 3.496
Weir height, ft ................ 0.167
Flow path length ft ................ 2.833
Flow path width ft ................ 4.182
Tray area, ft2 ................ 15.904
Tray active area ft2 ................ 11.849
% flood ................ 78.429
No. of caps ................ 74
Fractional entrainment ................ 0.004
Aeration factor ................ 0.641
Tray press loss, ft ................ 0.257
Tray press loss, atm ................ 0.006
Downcomer clearance ft ................ 0.146
Downcomer backup ft ................ 0.663
Downcomer residence time sec ............... 3.655
Downcomer apparent residence time sec ..... 8.269
Downcomer velocity ft/sec ............ 0.181
Liquid holdup m3 ................ 0.081
Liquid holdup kg ................ 66.623
Design pressure atm ................ 1.000
Joint efficiency ................ 0.850
Allowable stress atm ................ 932.230
Corrosion allowance ft ................ 0.003
Column thickness ft ................ 0.000
Bottom thickness ft ................ 0.000

Equip. 1 Tray No. 16

Tray Loadings Vapor Liquid


12268.435 kg/h 30817.211 kg/h
4203.220 m3/h 37.505 m3/h
Density 0.182 lb/ft3 51.296 lb/ft3
Tower internal diameter, ft ................ 4.500
Tray spacing, ft ................ 1.500
No. of tray liquid passes ................ 1
Downcomer dimension Width ft Length ft Area ft2
Side 0.833 3.496 2.028
Avg. weir length ft ................ 3.496
Weir height, ft ................ 0.167
Flow path length ft ................ 2.833
Flow path width ft ................ 4.182
Tray area, ft2 ................ 15.904
Tray active area ft2 ................ 11.849
% flood ................ 78.458
No. of caps ................ 74
Fractional entrainment ................ 0.004
Aeration factor ................ 0.641
Tray press loss, ft ................ 0.257
Tray press loss, atm ................ 0.006
Downcomer clearance ft ................ 0.146
Downcomer backup ft ................ 0.663
Downcomer residence time sec ............... 3.655
Downcomer apparent residence time sec ..... 8.268
Downcomer velocity ft/sec ............ 0.181
Liquid holdup m3 ................ 0.081
Liquid holdup kg ................ 66.630
Design pressure atm ................ 1.000
Joint efficiency ................ 0.850
Allowable stress atm ................ 932.230
Corrosion allowance ft ................ 0.003
Column thickness ft ................ 0.000
Bottom thickness ft ................ 0.000

Equip. 1 Tray No. 17

Tray Loadings Vapor Liquid


12269.424 kg/h 30818.199 kg/h
4203.730 m3/h 37.507 m3/h
Density 0.182 lb/ft3 51.295 lb/ft3
Tower internal diameter, ft ................ 4.500
Tray spacing, ft ................ 1.500
No. of tray liquid passes ................ 1
Downcomer dimension Width ft Length ft Area ft2
Side 0.833 3.496 2.028
Avg. weir length ft ................ 3.496
Weir height, ft ................ 0.167
Flow path length ft ................ 2.833
Flow path width ft ................ 4.182
Tray area, ft2 ................ 15.904
Tray active area ft2 ................ 11.849
% flood ................ 78.466
No. of caps ................ 74
Fractional entrainment ................ 0.004
Aeration factor ................ 0.641
Tray press loss, ft ................ 0.257
Tray press loss, atm ................ 0.006
Downcomer clearance ft ................ 0.146
Downcomer backup ft ................ 0.663
Downcomer residence time sec ............... 3.655
Downcomer apparent residence time sec ..... 8.267
Downcomer velocity ft/sec ............ 0.181
Liquid holdup m3 ................ 0.081
Liquid holdup kg ................ 66.631
Design pressure atm ................ 1.000
Joint efficiency ................ 0.850
Allowable stress atm ................ 932.230
Corrosion allowance ft ................ 0.003
Column thickness ft ................ 0.000
Bottom thickness ft ................ 0.000

Equip. 1 Tray No. 18

Tray Loadings Vapor Liquid


12265.820 kg/h 30814.600 kg/h
4202.419 m3/h 37.503 m3/h
Density 0.182 lb/ft3 51.295 lb/ft3
Tower internal diameter, ft ................ 4.500
Tray spacing, ft ................ 1.500
No. of tray liquid passes ................ 1
Downcomer dimension Width ft Length ft Area ft2
Side 0.833 3.496 2.028
Avg. weir length ft ................ 3.496
Weir height, ft ................ 0.167
Flow path length ft ................ 2.833
Flow path width ft ................ 4.182
Tray area, ft2 ................ 15.904
Tray active area ft2 ................ 11.849
% flood ................ 78.445
No. of caps ................ 74
Fractional entrainment ................ 0.004
Aeration factor ................ 0.641
Tray press loss, ft ................ 0.257
Tray press loss, atm ................ 0.006
Downcomer clearance ft ................ 0.146
Downcomer backup ft ................ 0.663
Downcomer residence time sec ............... 3.655
Downcomer apparent residence time sec ..... 8.268
Downcomer velocity ft/sec ............ 0.181
Liquid holdup m3 ................ 0.081
Liquid holdup kg ................ 66.626
Design pressure atm ................ 1.000
Joint efficiency ................ 0.850
Allowable stress atm ................ 932.230
Corrosion allowance ft ................ 0.003
Column thickness ft ................ 0.000
Bottom thickness ft ................ 0.000

Equip. 1 Tray No. 19

Tray Loadings Vapor Liquid


12248.678 kg/h 30797.455 kg/h
4196.220 m3/h 37.481 m3/h
Density 0.182 lb/ft3 51.295 lb/ft3
Tower internal diameter, ft ................ 4.500
Tray spacing, ft ................ 1.500
No. of tray liquid passes ................ 1
Downcomer dimension Width ft Length ft Area ft2
Side 0.833 3.496 2.028
Avg. weir length ft ................ 3.496
Weir height, ft ................ 0.167
Flow path length ft ................ 2.833
Flow path width ft ................ 4.182
Tray area, ft2 ................ 15.904
Tray active area ft2 ................ 11.849
% flood ................ 78.347
No. of caps ................ 74
Fractional entrainment ................ 0.004
Aeration factor ................ 0.641
Tray press loss, ft ................ 0.257
Tray press loss, atm ................ 0.006
Downcomer clearance ft ................ 0.146
Downcomer backup ft ................ 0.663
Downcomer residence time sec ............... 3.654
Downcomer apparent residence time sec ..... 8.273
Downcomer velocity ft/sec ............ 0.181
Liquid holdup m3 ................ 0.081
Liquid holdup kg ................ 66.598
Design pressure atm ................ 1.000
Joint efficiency ................ 0.850
Allowable stress atm ................ 932.230
Corrosion allowance ft ................ 0.003
Column thickness ft ................ 0.000
Bottom thickness ft ................ 0.000

Equip. 1 Tray No. 20

Tray Loadings Vapor Liquid


12248.678 kg/h 18548.779 kg/h
4196.220 m3/h 22.571 m3/h
Density 0.182 lb/ft3 51.302 lb/ft3
Tower internal diameter, ft ................ 4.500
Tray spacing, ft ................ 1.500
No. of tray liquid passes ................ 1
Downcomer dimension Width ft Length ft Area ft2
Side 0.833 3.496 2.028
Avg. weir length ft ................ 3.496
Weir height, ft ................ 0.167
Flow path length ft ................ 2.833
Flow path width ft ................ 4.182
Tray area, ft2 ................ 15.904
Tray active area ft2 ................ 11.849
% flood ................ 71.180
No. of caps ................ 74
Fractional entrainment ................ 0.014
Aeration factor ................ 0.641
Tray press loss, ft ................ 0.227
Tray press loss, atm ................ 0.006
Downcomer clearance ft ................ 0.146
Downcomer backup ft ................ 0.554
Downcomer residence time sec ............... 5.078
Downcomer apparent residence time sec ..... 13.738
Downcomer velocity ft/sec ............ 0.109
Liquid holdup m3 ................ 0.065
Liquid holdup kg ................ 53.333
Design pressure atm ................ 1.000
Joint efficiency ................ 0.850
Allowable stress atm ................ 932.230
Corrosion allowance ft ................ 0.003
Column thickness ft ................ 0.000
Bottom thickness ft ................ 0.000

Total column pressure drop = 0.106 atm