Sie sind auf Seite 1von 2

C10G/C10200 CMTS Quick Installation

Unband the shipping container from While on pallet, depopulate the front-installed With at least one other person, lift,
What’s inside the box? 1 the shipping pallet and lift off the 2 modules, power entry modules, and fan 3 position, and secure chassis to a
cardboard box. assemblies to reduce weight. Attach and use NEBS-compliant rack.
• C10G or C10200 chassis ESD strap.
• Console cables and related Remove the accessories box. CASA SYSTEMS
CCASA
ASA
C10G
hardware, SFPs, CD-ROM 0 1 2 3 4 5 6 7 8 9 10 11 12 13

CCASA
ASA
CASA SYSTEMS
C10G

SMM US 16X4 US 16X4


SMM
DS 8X8 US 16X4 US 16X4 DS 8X8 DS 8X8 DS 8X8 DS 8X8

10/100MI

10/100MI
G0 G0

G1 G1

G2 G2

Installation references G3

G4
G3

G4

G5 G5

• C10G CMTS Hardware G6

G7

STATUS STATUS
G6

G7

STATUS STATUS STATUS STATUS STATUS STATUS STATUS

Installation Guide
ALARM ALARM ALARM ALARM ALARM ALARM ALARM ALARM
ALARM
ACTIVE ACTIVE ACTIVE ACTIVE ACTIVE ACTIVE ACTIVE ACTIVE
ACTIVE XG2 XG2

XG1 XG1

• C10200 CMTS Hardware

IOIOI

IOIOI
STATUS STATUS
ACTIVE ACTIVE
ALARM ALARM

Installation Guide
• Casa Systems -- CMTS
A
Release Notes CAS EMS
T
SYS

Observe all electrical warnings and


1 FAN TRAY 1 FAN TRAY
precautions during installation. 1 FAN TRAY OK OK
OK HS HS
HS HS HS HS

7 7 7 7
After rack installation, repopulate the front-installed
4
Attach GND cable to chassis using Panduit LCD6-14AK-L 13
5 modules, power entry modules, and fan assemblies. 6 Connect PC or terminal to SMM for local setup.
or Thomas & Bretts 54205UF 45-degree terminal lug. 14

15

CCASA

0
ASA

1
CASA SYSTEMS
C10G
2 3 4 5 6 7 8 9 10 11 12 13
SMM
Console settings:
115200 bps

10/100MI
13 12 11 10 9 8 7 6 5 4 3 SMM SMM

8 data bits
US 16X4 US 16X4 US 16X4 DS 8X8 US 16X4 DS 8X8 DS 8X8 DS 8X8 DS 8X8

10/100MI

10/100MI
G0

G1
G0

G1
G0
No parity
G2

G3
G2

G3
G1
1 stop bit
G4 G4

G2 No flow control
OR
G5 G5

-48/60 VDC nom RTN -48/60 VDC nom


-48/60 VDC nom RTN -48/60 VDC nom RTN G6 G6

4 3 2 1 4 3 2 1 44 33 22 11 4 3 2 1
G7 G7
G3

4 3 2 1 4 3 2 1 STATUS
ALARM
ACTIVE
STATUS
ALARM
ACTIVE
STATUS
ALARM
ACTIVE
STATUS
ALARM
ACTIVE
STATUS
ALARM
ACTIVE
STATUS
ALARM
ACTIVE
STATUS
ALARM
ACTIVE
STATUS
ALARM
ACTIVE
STATUS
ALARM
ACTIVE
XG2 XG2

XG1 XG1 G4

Terminal or PC
IOIOI

IOIOI

TERMINAL BLOCK COVER TERMINAL BLOCK COVER STATUS STATUS


G5

ACTIVE ACTIVE

with DB-9
ALARM ALARM

HS HS

HS Remove terminal block cover and OK


HS Remove terminal block cover and G6

OK

all cables before removing PEM all cables before removing PEM
G7
serial port.
B PEM A PEM
XG2

XG1

1 FAN TRAY HS HS OK
1 FAN TRAY HS HS OK
1 FAN TRAY HS HS OK

IOIOI
STATUS
ACTIVE
ALARM

RJ-45 to RJ-45 RJ-45 to DB-9


cable adapter
C10G/C10200 Quick Installation (cont.)

Install SFPs and connect Ethernet RJ-45 Remove terminal cover and connect DC power cabling to Power Entry
7 (copper) or LC (fiber optic) connectors into SFPs 8
Connect RF I/O cables up to upstream and
downstream ports. Tighten F-connectors 9 Modules (PEMs), See the Hardware Installation Guide for information
to 15 inch-lbs of torque. on power sources and requirements.

Apply system power when ready. Turn on local console to confirm


SMM SMM
For remote management US IO
successful. system bootup. The CASA-CMTS# prompt will display.
QAM iO
10/100MI
over Telnet/SSH, insert
10/100MI

0
Ethernet RJ-45 connector Check LEDs on SMM, QAM, DQM, Ethernet ports, and fan module for
G0
G0
into 10/100 Ethernet 1 operational status.
0
G1
G1
port. Default IP address is 2

G2
G2
192.168.2.100; subnet 3
1
G3
G3 mask is 255.255.255.0. 4

2 -48/60 VDC nom RTN


G4
G4

5
4 3 2 1 4 3 2 1
G5
G5

6
3
G6
G6
GigE and 10GigE interfaces
7
G7
G7
to routers, switches, and HS
4 HS 4 3 2 1 4 3 2 1
8
servers (DHCP, TFTP, ToD). OK

XG2
XG2

9
5 A
XG1
XG1
10

11 6
IOIOI
IOIOI

12
STATUS STATUS
ACTIVE ACTIVE
ALARM
7
ALARM
13

14
From the local console or from a remote session such as a PuTTY session over Telnet or
10 15
SSH to the default IP address 192.168.2.100 of the 10/100 Ethernet port (eth 0), perform the 11
Configure the CMTS software, interfaces, routing protocols, BPI,
load balancing, spectrum management, modulation profiles, etc.
following tasks:
Refer to the following documents, available as downloads
1. Login to the CLI using the root login and the casa password.
in PDF format from the Casa FTP site.
2. Enable the CMTS privileged mode to configure the CMTS.
running configuration. The default password is casa.
Casa Systems -- CMTS Release Notes
3. Display the CMTS software version.
Casa Systems -- C10G CMTS Hardware Installation Guide
4. Enable configuration mode.
Casa Systems -- C10200 CMTS Hardware Installation Guide
5. Change the default IP address of the CMTS management port. See the example IP address below.
Casa Systems -- CMTS Software Configuration Guide
Casa Systems -- CMTS Debugging and Diagnostics Reference
.
CASA-CMTS login> root Casa Systems -- CMTS Network Solutions Guide
Password: casa
CASA-CMTS> enable
Password: casa
CASA-CMTS# show version
Running Image: SMM Rel 6.0, Ver 2, build 13, Tue Mar 8 09:21:33 EST 2011,(mlin)
Configured boot device: net
Target IP: 192.168.2.100, Host IP: 192.168.2.100
Boot Image: casa_6000.gz.rel6.0.2.build13

CASA-CMTS# config
CASA-CMTS(config)# interface eth 6/0
CASA-CMTS(config-if-eth 6/0)# ip address 135.2.0.0 255.255.255.0

Das könnte Ihnen auch gefallen