This manual briefly explains the operations that need to be performed by the user in order to connect an
ETERNUS DX Disk storage system to a server running VMware® ESX via a Fibre Channel interface.
This manual should be used in conjunction with any other applicable user manuals, such as those for the
ETERNUS DX Disk storage system, server, OS, Fibre Channel cards, and drivers.
This manual references the following documents:
• Server Support Matrix
• Server Support Matrix for FC-SWITCH
• ETERNUS DX Disk storage systems User's Guide -Server Connection- (Fibre Channel) Disk Storage System
Settings (ETERNUS DX80 S2/DX90 S2, ETERNUS DX410 S2/DX440 S2, ETERNUS DX8100 S2/DX8700 S2)
• ETERNUS DX Disk storage systems Server Connection Guide (Fibre Channel) ETERNUS DX Disk Storage Sys-
tem Settings for ETERNUS DX60/DX60 S2, DX80, DX90
• ETERNUS DX Disk storage systems Server Connection Guide (Fibre Channel) ETERNUS DX Disk Storage Sys-
tem Settings for ETERNUS DX400/DX8000 series
• ETERNUS DX Disk storage systems User's Guide -Server Connection- (Fibre Channel) Fibre Channel Switch
Settings
• ETERNUS DX Disk storage systems User's Guide -Server Connection- (Fibre Channel) for VMware® ESX Driver
Settings for Fujitsu Fibre Channel Cards
• ETERNUS DX Disk storage systems User's Guide -Server Connection- (Fibre Channel) for VMware® ESX Driver
Settings for Non-Fujitsu Fibre Channel Cards
• Web GUI User's Guide
• ETERNUSmgr Install Guide
• ETERNUSmgr User Guide
• Manuals supplied with the Fibre Channel card and software
This manual is designed for use with the following ETERNUS DX Disk storage systems:
• ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk storage system
• ETERNUS DX410 S2/DX440 S2 Disk storage system
• ETERNUS DX8100 S2/DX8700 S2 Disk storage system
• ETERNUS DX60/DX80/DX90 Disk storage system
• ETERNUS DX410/DX440 Disk storage system
• ETERNUS DX8100/DX8400/DX8700 Disk storage system
Twelfth Edition
September 2013
3
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Preface
Acknowledgments
• VMware, VMware logos, Virtual SMP, and VMotion are either registered trademarks or trademarks of
VMware, Inc. in the U.S. and/or other countries.
• Microsoft, Windows, and Windows Server are either registered trademarks or trademarks of Microsoft Cor-
poration in the U.S. and/or other countries.
• Emulex is a trademark of Emulex Corp.
• QLogic is a trademark of QLogic Corp.
• Linux is a registered trademark of Linus Torvalds.
• Red Hat is a registered trademark of Red Hat, Inc. in the U.S. and other countries.
• SUSE is a registered trademark of Novell, Inc., in the United States and other countries.
• The company names, product names and service names mentioned in this document are registered trade-
marks or trademarks of their respective companies.
• Microsoft product screen shot(s) reprinted with permission from Microsoft Corporation.
4
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Preface
Naming Conventions
■ Product names
• "VMware ESX" represents the following products:
- VMware vSphere (ESXi 5.5, ESXi 5.1, ESXi 5.0, ESX 4.1, ESXi 4.1, ESX 4.0, ESXi 4.0)
- VMware Infrastructure 3 (ESX 3.5, ESXi 3.5)
• "Windows Server® 2003" represents the following products.
- Microsoft® Windows Server® 2003, Standard Edition
- Microsoft® Windows Server® 2003, Enterprise Edition
- Microsoft® Windows Server® 2003, Standard x64 Edition
- Microsoft® Windows Server® 2003, Enterprise x64 Edition
- Microsoft® Windows Server® 2003 R2, Standard Edition
- Microsoft® Windows Server® 2003 R2, Enterprise Edition
- Microsoft® Windows Server® 2003 R2, Standard x64 Edition
- Microsoft® Windows Server® 2003 R2, Enterprise x64 Edition
- Microsoft® Windows Server® 2003, Enterprise Edition for Itanium-based Systems
- Microsoft® Windows Server® 2003, Datacenter Edition for Itanium-based Systems
- Microsoft® Windows® Storage Server 2003 R2, Standard Edition
- Microsoft® Windows® Storage Server 2003 R2, Enterprise Edition
- Microsoft® Windows® Storage Server 2003 R2, Standard x64 Edition
- Microsoft® Windows® Storage Server 2003 R2, Enterprise x64 Edition
■ Other names
• "Channel Adapter" (CA) refers to a Fibre Channel interface module that is used in an ETERNUS DX Disk stor-
age system to connect to a server.
• "Fibre Channel card" refers to a Fibre Channel interface module that is normally used in a server. A "Host
Bus Adapter" (HBA) or "Channel Adapter" (CA) may be used instead, depending on the server.
• "Fibre Channel cable" refers to a cable that is used to connect an ETERNUS DX Disk storage system and a
server via a Fibre Channel interface. "FC cable", "optical fibre cable", or "multi mode Fibre Channel cable"
may be used instead, depending on the storage system.
• "VMware ESX" refers to "VMware vSphere" and "VMware Infrastructure 3", which are datacenter solutions
from VMware that virtualize the storage and networking system.
The name "VMware vSphere" and "VMware Infrastructure 3" are used in specific datacenter sections.
• Italics are used to show variables such as values and characters that appear in command parameters and
output examples.
5
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Preface
6
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Table of Contents
Chapter 1 Workflow 9
Chapter 3 Notes 15
3.5 ETERNUS DX Disk Storage System to VMware VCB Proxy Server (on Windows®) Connection Notes ..
..................................................................................................................................................... 17
3.6 Server Startup and Power Supply Control Notes............................................................................. 17
3.7 Notes on WWN Instance Management Table for the Server ......................................................... 18
3.8 System Design Sheet Notes ......................................................................................................... 18
3.9 VMware Multipath Plug-in ........................................................................................................... 18
7
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Table of Contents
8
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 1
Workflow
This section describes how to connect the ETERNUS DX Disk storage systems to a server running VMware ESX.
This manual explains how to perform various operations not referenced in other documents.
Required Documents
• Server Support Matrix
• Server Support Matrix for FC-SWITCH
• ETERNUS DX Disk storage systems User's Guide -Server Connection- (Fibre Channel) Disk Storage System
Settings (ETERNUS DX80 S2/DX90 S2, ETERNUS DX410 S2/DX440 S2, ETERNUS DX8100 S2/DX8700 S2)
• ETERNUS DX Disk storage systems Server Connection Guide (Fibre Channel) ETERNUS DX Disk Storage Sys-
tem Settings for ETERNUS DX60/DX60 S2, DX80, DX90
• ETERNUS DX Disk storage systems Server Connection Guide (Fibre Channel) ETERNUS DX Disk Storage Sys-
tem Settings for ETERNUS DX400/DX8000 series
• ETERNUS DX Disk storage systems User's Guide -Server Connection- (Fibre Channel) Fibre Channel Switch
Settings
• ETERNUS DX Disk storage systems User's Guide -Server Connection- (Fibre Channel) for VMware® ESX Driver
Settings for Fujitsu Fibre Channel Cards
• ETERNUS DX Disk storage systems User's Guide -Server Connection- (Fibre Channel) for VMware® ESX Driver
Settings for Non-Fujitsu Fibre Channel Cards
• Web GUI User's Guide
• ETERNUSmgr Install Guide
• ETERNUSmgr User Guide
• Manuals supplied with the Fibre Channel card and software
9
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 1 Workflow
Workflow
10
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 1 Workflow
11
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 1 Workflow
12
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 2
Checking the Server Environment
2.1 Hardware
• VMware ESX connection may require the use of Fibre Channel switches, depending on the version of
VMware ESX used.
Fibre Channel switches that can be connected to the ETERNUS DX Disk storage system vary depending on
the connection environment (OS or the ETERNUS DX Disk storage system). Refer to "Server Support Matrix
for FC-SWITCH" to check the available Fibre Channel switches in advance.
• Access the following documents or use the "Server Support Matrix" to determine which models are compat-
ible with which servers.
- Search the VMware Compatibility Guide
http://www.vmware.com/resources/compatibility/search.php
• ETERNUS DX Disk storage systems support SAN Boot. For SAN Boot details, refer to "3.4 SAN Boot Notes
" (page 17).
• VMware ESX may be SAN Booted if a SAN Boot capable Fibre Channel card is used. For more details of
VMware ESX SAN Booting, refer to the following web-site and documents:
- Reference URL:
http://www.vmware.com/support/pubs/
- Reference documents:
"VMware vSphere Documentation: vSphere Storage Guide"
"VMware vSphere 4 Documentation: Fibre Channel SAN Configuration Guide"
"VMware Infrastructure 3 Documentation: Fibre Channel SAN Configuration Guide"
"VMware ESX Server 2.x Documentation: Server SAN Configuration Guide"
13
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 2 Checking the Server Environment
2.3 Connection Compatibility of ETERNUS DX Disk Storage Systems to VMware ESX
Access the following web-site to check which ETERNUS DX Disk storage system models may be connected to
VMware ESX:
• Search the VMware Compatibility Guide
http://www.vmware.com/resources/compatibility/search.php
14
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 3
Notes
Note the following issues when connecting the ETERNUS DX Disk storage system to a server.
• To ensure reliable access to the ETERNUS DX Disk storage systems, the following methods are recommen-
ded:
- Connection via multiple paths
- Balancing of active paths
- VMware multipath plug-in
VMware ESX
SN200#1 SN200#2
Fibre Channel Fibre Channel
switch switch
Cable
LUN0
Active path#1
(to LUN0)
Active path#2
LUN1
(to LUN1)
Setting up multiple access paths between the server and the ETERNUS DX Disk storage system creates a
multipath configuration. A multipath configuration provides improved access redundancy. For VMware
multipath plug-in details, refer to "3.9 VMware Multipath Plug-in " (page 18).
The recommended "Path Selection Policy" (per-LUN) setting is as follows:
• For VMware vSphere
"RoundRobin" is recommended.
15
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 3 Notes
3.2 VMware ESX Operating Notes
• Refer to the following web-site for the number of LUNs that VMware ESX can recognize.
http://www.vmware.com/support/pubs/
• When Windows® is used on the Virtual Machine, the registry will need to be modified after Windows® is
installed. For details, refer to "Chapter 10 Virtual Machine " (page 55).
• The VMware ESX's multipath function supports path failover, meaning that server access can continue un-
affected by any problems that might arise in the Fibre Channel cables or switches.
It should be noted that path failover can fail to occur when multiple SCSI sense codes are repeatedly and
simultaneously received.
• ETERNUS Multipath Driver and GR Multipath Driver do not need to be installed on a VMware ESX Virtual
Machine. The multipath function of VMware ESX provides path redundancy.
• When connecting a VMware ESX server to the ETERNUS DX Disk storage system, check that the firmware
version is as specified in the "Server Support Matrix".
• Assign Affinity Group values starting from LUN0 in ascending order. The server cannot recognize the ETER-
NUS DX Disk storage system LUNs if some other assignment order is used.
• When LUNs are shared among multiple physical servers (in a VMotion configuration, for example), an Af-
finity Group mapping should be used to ensure that each shared LUN is assigned the same LUN number
across every physical server.
• When connecting to VMware ESX with multiple paths sharing a single LUN, a Reset Group setting is re-
quired for the ETERNUS DX Disk storage system device.
• Details of dynamic recognition of LUNs added while VMware ESX is running are given in the "Chapter
11 Dynamic Recognition of LUNs Added While VMware ESX is in Use " (page 57).
16
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 3 Notes
3.4 SAN Boot Notes
When connecting a Windows®-based VMware VCB (VMware Consolidated Backup) Proxy server to an ETER-
NUS DX60/DX60 S2, DX80, DX90 or ETERNUS DX400/DX8000 series, the VMware ESX shares the LUNs, and the
ETERNUS DX60/DX60 S2, DX80, DX90 or ETERNUS DX400/DX8000 series settings must be adjusted.
For details on how to perform these settings, refer to the following documents:
• "ETERNUS DX Disk storage systems Server Connection Guide (Fibre Channel) ETERNUS DX Disk Storage Sys-
tem Settings for ETERNUS DX60/DX60 S2, DX80, DX90"
• "ETERNUS DX Disk storage systems Server Connection Guide (Fibre Channel) ETERNUS DX Disk Storage Sys-
tem Settings for ETERNUS DX400/DX8000 series"
Before turning the server on, check that the ETERNUS DX Disk storage systems and Fibre Channel switches
are all "Ready". If the server is turned on and they are not "Ready", the server will not be able to recognize
the ETERNUS DX Disk storage systems.
Also, when the ETERNUS DX Disk storage system power supply is being controlled by a connected server,
make sure that the ETERNUS DX Disk storage system does not shut down before the connected servers. Simi-
larly, the Fibre Channel switches must also be turned off after the connected servers have been shut down. If
turned off, data writes from the running server cannot be saved to the ETERNUS DX Disk storage systems, and
already saved data may also be affected.
17
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 3 Notes
3.7 Notes on WWN Instance Management Table for the Server
The WWN instance management table for the server is a worksheet that helps make the process of installing
an ETERNUS DX Disk storage system easy.
It is important to save the current environment after first installing the system and also after each post-in-
stallation system modification, addition, or maintenance operation. Creating an instance management table
makes installation and maintenance of the system easy. Use template instance management tables provi-
ded in "Appendix Various Management Tables (Template)" of the "ETERNUS DX Disk storage systems User's
Guide -Server Connection- (Fibre Channel) for Windows Driver Settings" for the Fibre Channel card being
used.
The system design sheet is a spreadsheet program work sheet that is used to simplify the process of instal-
ling the ETERNUS DX Disk storage system. It is important that the system details be recorded after first instal-
ling the system and also each time the system is subsequently modified, expanded, or has maintenance
work performed on it. Creating a system design sheet makes installation and maintenance of the system
easy.
For improved system reliability, installing the VMware multipath plug-in for the ETERNUS DX Disk storage
system is recommended. The VMware multipath plug-in for the ETERNUS DX Disk storage system can prevent
access from being stopped when a path fails by optimizing the VMware multipath's path fail-over function for
the ETERNUS DX Disk storage system. For setting details, refer to "8.4 Plug-in Settings" (page 40).
For details on how to obtain VMware Multi-Pathing plug-in for ETERNUS, contact your sales representative.
18
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 4
Installing and Setting Up ETERNUSmgr
If ETERNUSmgr is to be used, install it according to the directions given in the "ETERNUSmgr Install Guide".
After installation is complete, follow the instructions in "ETERNUSmgr User Guide" and set up ETERNUSmgr.
19
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 5
Setting Up the ETERNUS DX Disk Storage System
Set up the ETERNUS DX Disk storage systems using Web GUI or ETERNUSmgr.
ETERNUS DX Disk storage system setup can be performed independently of server setup. For details on how
to perform these settings, refer to the following manuals.
• "ETERNUS DX Disk storage systems User's Guide -Server Connection- (Fibre Channel) Disk Storage System
Settings (ETERNUS DX80 S2/DX90 S2, ETERNUS DX410 S2/DX440 S2, ETERNUS DX8100 S2/DX8700 S2)"
• "ETERNUS DX Disk storage systems Server Connection Guide (Fibre Channel) ETERNUS DX Disk Storage Sys-
tem Settings for ETERNUS DX60/DX60 S2, DX80, DX90"
• "ETERNUS DX Disk storage systems Server Connection Guide (Fibre Channel) ETERNUS DX Disk Storage Sys-
tem Settings for ETERNUS DX400/DX8000 series"
• "Web GUI User's Guide" or "ETERNUSmgr User Guide"
20
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 6
Setting Up the Fibre Channel Switches
Perform the settings required to connect the ETERNUS DX Disk storage systems and server via the Fibre Chan-
nel switch, according to "ETERNUS DX Disk storage systems User's Guide -Server Connection- (Fibre Channel)
Fibre Channel Switch Settings".
If the access path is set with ETERNUS SF Storage Cruiser, the Host Response settings are set to the default
values.
If the Host Response settings are changed from the default values, set the Host Response again.
The following examples show configurations in which a server is connected to a Fibre Channel switch with
zoning.
The following example shows a configuration in which multiple servers are connected to multiple CAs.
ZONE4
FC switch FC switch
Cascading
CA00 CA01 CA10 CA11
line
CM0 CM1
21
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 6 Setting Up the Fibre Channel Switches
The following example shows a configuration in which a single server is connected to multiple CAs.
Server
Slot 0 Slot 1
ZONE1
ZONE3 ZONE4
ZONE2
FC switch FC switch
P0 P1 P0 P1 Cascading
line
CM0 CM1
22
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 7
Setting Up the VMware ESX Server
Set up the VMware ESX server as detailed in the "ETERNUS DX Disk storage systems User's Guide -Server Con-
nection- (Fibre Channel) for VMware® ESX Driver Settings" for the Fibre Channel card being used.
• "ETERNUS DX Disk storage systems User's Guide -Server Connection- (Fibre Channel) for VMware® ESX Driver
Settings for Fujitsu Fibre Channel Cards"
• "ETERNUS DX Disk storage systems User's Guide -Server Connection- (Fibre Channel) for VMware® ESX Driver
Settings for Non-Fujitsu Fibre Channel Cards"
23
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 8
For VMware vSphere
2 Check that the Ready LED (or equivalent) is lit on the Fibre Channel switch.
4 Check that the Ready LED is lit on the ETERNUS DX Disk storage system.
24
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 8 For VMware vSphere
8.1 Checking the LUNs
This procedure is only required when VMware vSphere contains VMware ESX 4.0/VMware ESXi 4.0.
It does not need to be performed when VMware vSphere contains VMware ESX 4.0 Update 1/VMware ESXi
4.0 Update 1 or later versions.
In this case, proceed to "8.1.4 Checking the LUNs " (page 27).
After the VMware ESX server has been installed, Asymmetric Logical Unit Access (ALUA) should be enabled
according to the following procedure.
Ignore the following error message if it appears when the preceding command is executed:
Errors:
Unable to perform unclaim. Error message was : Unable to unclaim paths. Busy
or in use devices detected.
See VMkernel logs for more information.
25
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 8 For VMware vSphere
8.1 Checking the LUNs
5 Check that the connected ETERNUS DX Disk storage system is shown when the appropriate command is
executed in the terminal:
6 Log out of the terminal, and restart the VMware ESX server.
26
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 8 For VMware vSphere
8.1 Checking the LUNs
4 Select [Rescan...].
After selecting [Rescan...], the VMware ESX should attempt to recognize the ETERNUS DX Disk stor-
age systems' LUNs again.
5 Select the virtual HBA (vmhba2 in this example) for the Fibre Channel card from the [Storage Adapters]
area.
The recognized devices will be shown in the [Details] area, as follows.
27
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 8 For VMware vSphere
8.1 Checking the LUNs
6 Connect to the VMware ESX server via the vSphere Client and check [Path Selection] for all the LUNs in
the ETERNUS Disk storage system.
When the VMware ESX server recognizes the LUNs, the active path for each LUN is automatically set.
Even though [Path Selection] is set to [Most Recently Used (VMware)], changing the [Path Selection]
for all the LUNs to [RoundRobin] is recommended.
28
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 8 For VMware vSphere
8.2 Checking the Active Paths
VMware ESX
HBA#1
SN200#1
(Fibre Channel Switch)
RAID Group#1
: LUN1
29
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 8 For VMware vSphere
8.2 Checking the Active Paths
4 Select the virtual HBA (vmhba2 in this example) for the Fibre Channel card from the [Storage Adapters]
area.
The recognized devices will be shown in the [Details] area, as follows.
30
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 8 For VMware vSphere
8.2 Checking the Active Paths
5 Select and right click the virtual device (vmhba1:C0:T0:L21 in this example) in the [Details] area. Select
[Manage Paths] from the popup menu.
6 Check the WWNs of the ETERNUS DX Disk storage systems' CA ports that are connected with the Fibre
Channel cards.
The following connection would be displayed for the current configuration example:
• HBA#1 to ETERNUS DX Disk storage system CM#0 CA#0 Port#0
31
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 8 For VMware vSphere
8.2 Checking the Active Paths
32
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 8 For VMware vSphere
8.2 Checking the Active Paths
4 If the virtual HBA (vmhba2 in this example) for the Fibre Channel card is selected from the [Storage
Adapters] area,
the recognized devices will be shown in the [Details] area, as follows.
5 Right click the virtual device in the [Details] area and select [Manage Paths].
33
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 8 For VMware vSphere
8.2 Checking the Active Paths
6 Check the WWNs of the ETERNUS DX Disk storage systems' CA ports that are connected with the Fibre
Channel cards.
The following connection would be displayed for the current configuration example:
• RAID Group#0:LUN0 has the following access paths:
- HBA#1 to ETERNUS DX Disk storage system CM#0 CA#0 Port#0
- HBA#2 to ETERNUS DX Disk storage system CM#1 CA#0 Port#0
34
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 8 For VMware vSphere
8.2 Checking the Active Paths
35
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 8 For VMware vSphere
8.2 Checking the Active Paths
- ETERNUS DX Disk storage system CM#0 CA#0 Port#0 to HBA#1 is the "Active (I/O)" path
- ETERNUS DX Disk storage system CM#1 CA#0 Port#0 to HBA#2 is the "Active (I/O)" path
- ETERNUS DX Disk storage system CM#0 CA#0 Port#0 to HBA#3 is the "Active (I/O)" path
- ETERNUS DX Disk storage system CM#1 CA#0 Port#0 to HBA#4 is the "Active (I/O)" path
36
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 8 For VMware vSphere
8.3 Setting Up the Volumes
- 4-path configuration LUN active paths can be checked in the following window:
37
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 8 For VMware vSphere
8.3 Setting Up the Volumes
38
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 8 For VMware vSphere
8.3 Setting Up the Volumes
8 Select the [Maximum file size] and click the [Next] button.
9 The settings are displayed. Check them, and click the [Finish] button if they are correct.
11 To check or change the settings of the created volume, select the matching LUN in the [Storage] area.
Click the [Properties...] link after the volume details are displayed in the [Details] area.
39
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 8 For VMware vSphere
8.4 Plug-in Settings
Set up VMware Multi-Pathing plug-in for ETERNUS by following "Software Information", which is a manual
that is provided with the VMware Multi-Pathing plug-in for ETERNUS.
40
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 9
For VMware Infrastructure 3
This chapter describes the VMware Infrastructure 3 setup procedures. Refer to "Chapter 8 For VMware vSphere
" (page 24) for the VMware vSphere setup procedures.
2 Check that the Ready LED (or equivalent) is lit on the Fibre Channel switch.
4 Check that the Ready LED is lit on the ETERNUS DX Disk storage system.
41
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 9 For VMware Infrastructure 3
9.1 Checking the LUNs
4 Select [Rescan...].
After selecting [Rescan...], the VMware ESX should attempt to recognize the ETERNUS DX Disk stor-
age systems' LUNs again.
5 Select the virtual HBA (vmhba2 in this example) for the Fibre Channel card from the [Storage Adapters]
area.
The recognized devices will be shown in the [Details] area, as follows.
42
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 9 For VMware Infrastructure 3
9.2 Checking the Active Paths
Check the active paths to improve of the access performance by the server.
Example of each type of configuration and the corresponding active path setting operations follow.
VMware ESX
HBA#1
SN200#1
(Fibre Channel Switch)
RAID Group#1
: LUN1
43
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 9 For VMware Infrastructure 3
9.2 Checking the Active Paths
4 If the virtual HBA (vmhba2 in this example) for the Fibre Channel card is selected from the [Storage
Adapters] area,
the recognized devices will be shown in the [Details] area, as follows.
5 Right click the virtual device (vmhba2:0:1 in this example) in the [Details] area and select [Manage
Paths].
6 Check the WWNs of the ETERNUS DX Disk storage systems' CA ports that are connected with the Fibre
Channel cards.
The following connection would be displayed for the current configuration example:
44
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 9 For VMware Infrastructure 3
9.2 Checking the Active Paths
VMware ESX
HBA#1 HBA#2
SN200#1 SN200#2
(Fibre Channel Switch) (Fibre Channel Switch)
Active
RAID Group#1
Path
: LUN1
45
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 9 For VMware Infrastructure 3
9.2 Checking the Active Paths
4 Select the virtual HBA (vmhba2 in this example) for the Fibre Channel card from the [Storage Adapters]
area.
The recognized devices will be shown in the [Details] area, as follows.
46
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 9 For VMware Infrastructure 3
9.2 Checking the Active Paths
5 Right click the virtual device in the [Details] area and select [Manage Paths].
47
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 9 For VMware Infrastructure 3
9.2 Checking the Active Paths
6 Check the WWNs of the ETERNUS DX Disk storage systems' CA ports that are connected with the Fibre
Channel cards.
The following connection would be displayed for the current configuration example:
• RAID Group#0:LUN0 has the following access paths:
- HBA#1 to ETERNUS DX Disk storage system CM#0 CA#0 Port#0
- HBA#2 to ETERNUS DX Disk storage system CM#1 CA#0 Port#0
48
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 9 For VMware Infrastructure 3
9.2 Checking the Active Paths
49
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 9 For VMware Infrastructure 3
9.2 Checking the Active Paths
8 To balance the access paths in this example, the RAID Group#1:LUN1 active paths must be switched.
To change an active path, select a new virtual HBA (vmhba3 in this example) for the LUN in its [Man-
age Paths] dialog.
9 Select the [Preferred] checkbox and click the [OK] button to change the preferred path.
50
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 9 For VMware Infrastructure 3
9.2 Checking the Active Paths
10 Check that [*] is displayed in the [Preferred] column for the preferred virtual HBA path (vmhba3:0:1 in
the following example) in the [Manage Paths] dialog, and click the [OK] button.
11 Select [Manage Paths] again to check that the path has been changed. "Active" should be displayed in
the [Status] column for the preferred path, as shown below.
51
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 9 For VMware Infrastructure 3
9.3 Setting Up the Volumes
52
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 9 For VMware Infrastructure 3
9.3 Setting Up the Volumes
8 Select the [Maximum file size] and click the [Next] button.
9 The settings are displayed. Check them, and click the [Finish] button if they are correct.
53
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 9 For VMware Infrastructure 3
9.3 Setting Up the Volumes
11 To check or change the settings of the created volume, select the matching LUN in the [Storage] area.
Click the [Properties...] link after the volume details are displayed in the [Details] area.
54
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 10
Virtual Machine
This chapter describes the notes on the Virtual Machine and its settings.
To configure the Virtual Machine, access the following web-site and check the "Guest Operation System In-
stallation Guide".
• Guest Operation System Installation Guide
http://partnerweb.vmware.com/GOSIG/home.html
2 In the [Run] dialog box, type "regedit", and then click the [OK] button.
Registry Editor starts.
\HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\Disk
55
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 10 Virtual Machine
10.2 For Linux
• If the "TimeOutValue" key does not exist, add a registry key with the following values:
• The "Name" field is case-sensitive.
Name TimeOutValue
Type REG_DWORD
Radix Hexadecimal
Data 3C
5 If any registry values were added or modified, reboot the server. The modified settings will be enabled
after the reboot.
56
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
Chapter 11
Dynamic Recognition of LUNs Added While
VMware ESX is in Use
When adding LUNs while VMware ESX is in use (recognizing LUNs dynamically), first assign the added vol-
umes to an ETERNUS DX Disk storage system Host Affinity Group, and then LUNs should be recognized with
the "Rescan" operation via the VMware Infrastructure Client (Infrastructure 3) or vSphere Client, respectively
described in "8.1 Checking the LUNs " (page 24) and "9.1 Checking the LUNs " (page 41).
57
ETERNUS DX Disk storage systems User's Guide -Server Connection-(Fibre Channel) for VMware® ESX
Copyright 2013 FUJITSU LIMITED
P3AM-3922-12ENZ0
ETERNUS DX Disk storage systems User's Guide -Server Connection-
(Fibre Channel) for VMware® ESX
P3AM-3922-12ENZ0