ARNU05G TRB4 ARNU07G TRB4 ARNU09GTRB4
ARNU12GTRB4 ARNU15G TQB4 ARNU18G TQB4 ARNU21GTQB4

ARNU05GTR TR B4 ARNU09GTR B4 ARNU12G TRB4 ARNU15GTQB4 ARNU18GTQB4 ARNU21GTQB4

ARNU05GTRB4 ARNU07GTRB4 ARNU09GTRB4 ARNU12GTR B4 ARNU15GTQB4 ARNU18GTQ B4 ARNU21GTQB4


Btu/h 9,600 12,300 19,100 24,200

Btu/h 10,900 13,600 21,500 27,300


31 / 26 / 23 40 / 31 / 25 40 / 34 / 27 70 / 53 / 43 104 / 75 / 53 120 / 80 / 62 135 / 93 / 70

9.52(3/8)
15.88(5/8)
ARNU07G TUB4 ARNU09GTUB4
ARNU12GTUB4 ARNU18GTTB4 ARNU24GTTB4

ARNU05GTRB4, ARNU07GTRB4,ARNU09GTRB4, ARNU12GTRB4, ARNU15GTQB4,


ARNU18GTQB4, ARNU21GTQB4, ARNU24GTPA4, ARNU28GTPA4,
ARNU30GTPA4, ARNU36GTNA4, ARNU42GTMA4, ARNU48GTMA4, ARNU54GTMA4

ARNU07GTU B4 TU B4 TU B4 TT B4 TTB4

ARNU07GTU B4 TU B4 TU B4 TT B4 TTB4
ARNU07GTUB4, ARNU09GTUB4, ARNU12GTUB4,
ARNU18GTTB4, ARNU24GTTB4
ARNU76GB8Z4,
VENTILATION
SOLUTION
ERV
VENTILATION
VENTILATION SOLUTION KEY FEATURES

SOLUTION
ERV

High Efficiency Heat Exchanger Exhaust Air Supply Air Bypass Ventilation
Efficiency and comfort is ensured through the high- LG ERV automatically switches the ventilation mode (Enthalpy Heat Exchange Mode / Bypass Mode) according to
efficiency energy recovery central core which recovers the indoor / outdoor temperature.
energy from the indoor air and transfers it to the fresh
incoming air without mixing airstream. Enthalpy Heat Exchange Mode (Summer / Winter) Bypass Mode (Seasonal Change)
Damper Damper
Outdoor Air Air Filter Indoor Air

Interlocking with Air Conditioning System


- LG ERV can be interlocked with air conditioners
and controlled individually.
- This function can be operated when the system is Cooling / Heating Mode
Set Temperature
connected with a remote control.

Flexibility of Installation
It’s possible to install upside down when you need only one inspection hole.

Normal installation of 2 units Reverse installation of 1 unit (Left unit)


Compulsory Exhausting System
The exhausting system using high static and sirocco fan removes contaminants effectively from indoor air. Supply
and exhaust air flows are completely separated in the total heat exchanger, LG ERV can filter out the impurities
before supplying outdoor air and make indoor air fresh and healthy.

Outdoors Indoors
Damper

Exhaust Air Return Air


Exhaust Air Supply Air

Inspection chamber
Outdoor Air Supply Air Top Low
Outdoor Air Return Air

Total Heat
Exchanger
Low Top

42 43
VENTILATION
VENTILATION SOLUTION KEY FEATURES

SOLUTION
ERV

Easy Cleaning and Filter Change Fast Ventilation Mode


It is easy and convenient to change and clean the filter. Fast ventilation mode prevents the spread of contaminants under negative indoor pressure, and makes indoor air
fresh and comfortable quickly.

Only Exhausting Fast Ventilation Mode

Exhaust
Exhausting Fan
and Supplying
Simultaneously Supply
Fan

ERV Unit Remove Side Panel

Exhausting operation causes negative indoor air


pressure, and cannot fully ventilate.

CO2 Concentration Control


Using CO2 sensor, LG ERV controls exhaust air flow automatically to keep indoor air fresh under settled CO2 concentration.

Change Filter Remove Heat Exchanger

CASE #1 CASE #2

External Static Pressure Control CO2 Sensor


New
Standard
Wired
Standard
Wired CO2 Sensor
(AHCS 100H0) Remote Remote (PES-C0RV0)
The high static pressure fan can control the air volume Air
Volume (Internal Type) Controller Controller (External Type)
depending on the length of the duct. It is also easy to
control the pressure level by using the remote controller CO2
H (ppm)
for a more flexible duct installation and easier testing.
M
L
Windows Windows Windows Windows
Closed Open Closed Open
H 2,500
M
L

External Static Pressure (mmAq) 1,000

0
ERV with CO 2 Concentration Control
Time (min)

44 45
VENTILATION
VENTILATION SOLUTION KEY FEATURES

SOLUTION
ERV

New Easy Controller Night Time Cooling


New wired remote controller is easy for usage. Discharge the indoor heat in the summer night and supply cool outdoor air to indoors. so it can save energy.

Outdoor ERV is turned on automatically ERV is turned off


temperature at night is when the outside is when the inside temperature is
getting low. cooler than inside. lower than set temperature.
Convenient!
• Flexible display
- Dual display with air conditioner.
- Zoom selected directory to increase legibility.

Easy! Visible!
• Navigation buttons, easy to use. • Indoor CO2 level
• Easy installation setting
ERV makes inside cooler with bypass mode
Outside Temp. like nature ventilation.
Set Temp.

Inside Temp.

Air Purifying System (3 Steps) 2%


Energy Saving
(Annually)
LG ERV can effectively remove the various harmful substances, such as micro dust and viruses.
Possible selection of the high efficiency filter(F7) for micro dust removed.

Step 2: Heat Exchanger Night Morning Time

Anti virus coating, block the breeding of harmful viruses.

* This function is operated with ‘Night Time Free Cooling’ on remote controller. (with MULTI V only)
** Energy saving ratio Can vary with condition.
*** Available only with Standard III

• Test Condition
- Office (49,000 ft2) / Occupancy : 30 / Area : London, UK
- ERV (1 000 CMH) + MULTI V 4 (12 HP) Unit Combination
- Other conditions are subject to BREEAM.
(Building Research Establishment's Environmental Assessment Method)

Step 1: Basic Filter


Installed front and behind of heat exchanger Step 3: High Efficiency Filter (F7)

Installed in front of heat exchanger. (option)

46 47
VENTILATION
VENTILATION SOLUTION SPECIFICATION

SOLUTION
ERV
LZ-H025GBA4 / LZ-H035GBA4 / LZ-H050GBA4 LZ-H080GBA4 / LZ-H100GBA4
LZ-H150GBA4 / LZ-H200GBA4

Model LZ-H025GBA4 LZ-H035GBA4 LZ-H050GBA4 Model LZ-H080GBA4 LZ-H100GBA4 LZ-H150GBA4 LZ-H200GBA4


Nominal Capacity CMH (CFM) 250 (147) 350 (206) 500 (294) Nominal Capacity CMH (CFM) 800 (471) 1,000 (589) 1,500 (883) 2,000 (1,177)
Power Supply Ø / V / Hz 1 / 220~240 / 50, 60 Power Supply Ø / V / Hz 1 / 220~240 / 50, 60
Step - SUPER-HIGH / HIGH / LOW Step - SUPER-HIGH / HIGH / LOW
Current SH / H / L Amps 0.70 / 0.60 / 0.42 1.10 / 0.95 / 0.60 1.92 / 1.58 / 0.79 Current SH / H / L Amps 2.77 / 2.16 / 1.44 3.41 / 2.90 / 1.76 5.60 / 5.40 / 2.90 6.80 / 5.90 / 3.60
Power Input SH / H / L W 97 / 78 / 52 180 / 163 / 88 240 / 220 / 90 Power Input SH / H / L W 390 / 280 / 187 480 / 385 / 210 780 / 540 / 377 960 / 770 / 420
250 / 250 / 150 350 / 350 / 210 500 / 500 / 320 800 / 800 / 660 1,000 / 1,000 / 800 1,500 / 1,500 / 1,200 2,000 / 2,000 / 1,600
Air Flow SH / H / L CMH (CFM) Air Flow SH / H / L CMH (CFM)
(147 / 147 / 88) (206 / 206 / 123) (294 / 294 / 124) (471 / 471 / 388) (589 / 589 / 471) (883 / 883 / 706) (1,177 / 1,177 / 942)
ERV Mode 100 / 70 / 50 150 / 130 / 100 150 / 100 / 50 ERV Mode 200 / 110 / 60 160 / 90 / 50 200 / 110 / 60 160 / 90 / 50
External Static Pressure SH / H / L Pa (inWTR) External Static Pressure SH / H / L Pa (inWTR)
(0.40 / 0.28 / 0.20) (0.60 / 0.52 / 0.40) (0.60 / 0.40 / 0.20) (0.80 / 0.44 / 0.24) (0.64 / 0.36 / 0.20) (0.80 / 0.44 / 0.24) (0.64 / 0.36 / 0.20)
SH / H / L % 80 / 80 / 83 75 / 75 / 77 78 / 78 / 79 SH / H / L % 79 / 79 / 82 77 / 77 / 78 79 / 79 / 82 77 / 77 / 78
Heating (SH / H / L) % 70 / 70 / 72 68 / 68 / 70 73 / 73 / 75 Heating (SH / H / L) % 72 / 72 / 74 70 / 70 / 72 72 / 72 / 74 70 / 70 / 72
Cooling (SH / H / L) % 66 / 66 / 68 63 / 63 / 65 66 / 66 / 69 Cooling (SH / H / L) % 63 / 63 / 66 59 / 59 / 63 63 / 63 / 66 59 / 59 / 63
Noise Level (Sound Level, 1.5m) SH / H / L dB (A) 29 / 28 / 24 32 / 30 / 27 34 / 32 / 25 Noise Level (Sound Level, 1.5m) SH / H / L dB (A) 40 / 37 / 31 41 / 38 / 32 43 / 40 / 34 44 / 41 / 35
Step - SUPER-HIGH / HIGH / LOW Step - SUPER-HIGH / HIGH / LOW
Current SH / H / L Amps 0.70 / 0.60 / 0.42 1.10 / 0.95 / 0.60 1.92 / 1.58 / 0.79 Current SH / H / L Amps 2.77 / 2.16 / 1.44 3.41 / 2.90 / 1.76 5.60 / 5.40 / 2.90 6.80 / 5.90 / 3.60
Power Input SH / H / L W 97 / 78 / 52 180 / 163 / 88 240 / 220 / 90 Power Input SH / H / L W 390 / 280 / 187 480 / 385 / 210 780 / 540 / 377 960 / 770 / 420
250 / 250 / 150 350 / 350 / 210 500 / 500 / 320 800 / 800 / 660 1,000 / 1,000 / 800 1,500 / 1,500 / 1,200 2,000 / 2,000 / 1,600
Bypass Mode Air Flow SH / H / L CMH (CFM) Bypass Mode Air Flow SH / H / L CMH (CFM)
(147 / 147 / 88) (206 / 206 / 123) (294 / 294 / 124) (471 / 471 / 388) (589 / 589 / 471) (883 / 883 / 706) (1,177 / 1,177 / 942)
100 / 70 / 50 150 / 130 / 100 150 / 100 / 50 200 / 110 / 60 160 / 90 / 50 200 / 110 / 60 160 / 90 / 50
External Static Pressure SH / H / L Pa (inWTR) External Static Pressure SH / H / L Pa (inWTR)
(0.40 / 0.28 / 0.20) (0.60 / 0.52 / 0.40) (0.60 / 0.40 / 0.20) (0.80 / 0.44 / 0.24) (0.64 / 0.36 / 0.20) (0.80 / 0.44 / 0.24) (0.64 / 0.36 / 0.20)
Noise Level (Sound Level, 1.5m) SH / H / L dB (A) 29 / 29 / 25 32 / 30 / 27 35 / 33 / 25 Noise Level (Sound Level, 1.5m) SH / H / L dB (A) 41 / 38 / 32 41 / 39 / 33 44 / 41 / 35 44 / 42 / 36
Heat Exchanger Type - Heat Exchanger Type -
Net Weight kg 44 44 44 Net Weight kg 62 140
Dimension WxHxD mm 988 x 273 x 1,014 988 x 273 x 1,014 988 x 273 x 1,014 Dimension WxHxD mm 1,062 x 365 x 1,140 1,313 x 738 x 1,140
Qty EA 4 Qty EA 4 4+2
Duct work* Duct work*
Size (Ø) mm Ø200 Size (Ø) mm Ø250 Ø250 + Ø350
Qty EA 1 Qty EA 1 2
Supply Air Fan Supply Air Fan
Type - Direct-Drive (Sirocco Fan) Type - Direct-Drive (Sirocco Fan)
Qty EA 1 Qty EA 1 2
Exhaust Air Fan Exhaust Air Fan
Type - Direct-Drive (Sirocco Fan) Type - Direct-Drive (Sirocco Fan)
Qty EA 2 2 Qty EA 2 4
Filters (Default) Type - Filters (Default) Type -
Size (W x H x D) mm 855 x 10 x 160 855 x 6 x 230 Size (W x H x D) mm 1,056 x 6 x 212.5
Model - AHFT035H0 AHFT050H0 Model - AHFT100H0
Qty EA 2 2 Qty EA 2 4
Filters (Optional) Filters (Optional)
Type - F7 F7 Type - F7
Size (W x H x D) mm 423.5 x 132 x 25 425 x 194 x 25 Size (W x H x D) mm 520 x 192 x 25
Dry Contact PDRYCB000 Dry Contact PDRYCB000

Note : 1. ERV mode : Total Heat Recovery Ventilation mode Note : 1. ERV mode : Total Heat Recovery Ventilation mode
2. * : Refer to dimensional drawings. 2. * : Refer to dimensional drawings.
3. Noise level : 3. Noise level :
- The operating conditions are assumed to be standard - The operating conditions are assumed to be standard
- Sound measured at 1.5m below the center the body. - Sound measured at 1.5m below the center the body.
- Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed. - Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed.
- The sound level at the air discharge port is about 8 dB(A) higher than the unit's operating sound. - The sound level at the air discharge port is about 8 dB(A) higher than the unit's operating sound.
4. Temperature and Enthalpy Exchange Efficiency at cooling 4. Temperature and Enthalpy Exchange Efficiency at cooling
Indoor Temperature : 26.5°C DB, 64.5% RH, Outdoor Temperature : 34.5°C DB, 75% RH Indoor Temperature : 26.5°C DB, 64.5% RH, Outdoor Temperature : 34.5°C DB, 75% RH
5. Temperature and Enthalpy Exchange Efficiency at heating 5. Temperature and Enthalpy Exchange Efficiency at heating
Indoor Temperature : 20.5°C DB, 59.5% RH, Outdoor Temperature : 5°C DB, 65% RH Indoor Temperature : 20.5°C DB, 59.5% RH, Outdoor Temperature : 5°C DB, 65% RH
6. Temperature Exchange efficiency is tested at heating condition. 6. Temperature Exchange efficiency is tested at heating condition.
7. F7 Filter is 2 pieces in 1 filter package 7. F7 Filter is 2 pieces in 1 filter package

Premium Standard III Standard II CO2 Sensor Premium Standard III Standard II CO2 Sensor

PREMTA000 PREMTA000
PREMTB100 PREMTBB10 PREMTBB01 PREMTB001 PES-C0RV0 AHCS100H0 PREMTB100 PREMTBB10 PREMTBB01 PREMTB001 PES-C0RV0 AHCS100H0
PREMTA000A PREMTA000A
(External Type) (Internal Type) (External Type) (Internal Type)
PREMTA000B PREMTA000B

48 49
VENTILATION
VENTILATION SOLUTION SPECIFICATION

SOLUTION
ERV

LZ-H025GBA4 Ventilation
LZ-H100GBA4 Ventilation

Exchange Efficiency (%)


200 90 90
External Static Pressure (Pa)

External Static Pressure (Pa)


Super-High 500 Super-High
180 85 85
High High
160 Low 80 Low 80
400
140 75 75
120 70 70
300
100 65 65
80 60 60
200
60 55 55
40 50 100 50
20 45 45
40 40
0 100 200 300 400 500 0 100 200 300 400 500 0 200 400 600 800 1,000 1,200 500 700 900 1,100 1,300
Air Volume (m3/h) Air Volume (m3/h) Air Volume (m3/h) Air Volume (m3/h)

LZ-H035GBA4 Ventilation
90
LZ-H150GBA4 Ventilation

Exchange Efficiency (%)


External Static Pressure (Pa)

90

External Static Pressure (Pa)


Super-High 500 Super-High
400 High 85 85
High
Low 80 Low 80
350 400
75 75
300
70 70
250 300
65 65
200 60 60
200
150 55 55
100 50 50
100
50 45 45
40 40
0 100 200 300 400 500 0 100 200 300 400 500 0 400 800 1,200 1,600 2,000 1,000 1,200 1,400 1.600 1,800 2,000 2,200
Air Volume (m3/h) Air Volume (m3/h) Air Volume (m3/h) Air Volume (m3/h)

LZ-H050GBA4 Ventilation
LZ-H200GBA4 Ventilation
External Static Pressure (Pa)

Exchange Efficiency (%)

90

Exchange Efficiency (%)


400 Super-High 90

External Static Pressure (Pa)


500 Super-High
High 85 85
High
Low 80 Low 80
300 400
75 75
70 70
300
200 65 65
60 60
200
55 55
100
50 50
100
45 45
40 40
0 100 200 300 400 500 600 700 800 0 100 200 300 400 500 600 700 800 0 500 1,000 1,500 2,000 2,500 1,000 1,200 1,400 1.600 1,800 2,000 2,200
Air Volume (m3/h) Air Volume (m3/h)
Air Volume (m3/h) Air Volume (m3/h)

LZ-H080GBA4 Ventilation
External Static Pressure (Pa)

Exchange Efficiency (%)

500 90
Super-High
High 85
400 Low 80
75
300 70
65
200 60
55
100
50
45
40
0 200 400 600 800 1,000 1,200 500 600 700 800 900 1,000 1,100 1,200
Air Volume (m3/h) Air Volume (m3/h)

50 51