PORTABLE DATALOGGER & ACCESSORIES
Archimede Datalogger
User Manual
rev.4 -04.07.2016-
Archimede Portable Dataloggers User Manual
INDEX
When replacing parts, use only ORIGINAL SPARE PARTS. The use of unoriginal SISGEO spare parts
may cause irregular functioning and dangers for people and objects
The product is not suitable for installations in small and/or unventilated environments, with a high
humidity range or in the presence of inflammable or explosive liquids. All the supplied instruments
and equipment are not suitable for installations in potential dangerous areas or where explosion-
proof components are used.
The electrical connections must be executed by a qualified technician, observing all the
regulations in force.
The manufacturer reserves the right to make changes, in case of any manufacturing or commercial
need, without notice. Even so, the manufacturer will attempt to ensure that user manuals are
updated in order to reflect functional product revisions.
WASTE DISPOSAL
SYMBOLOGY
Here below are reported the symbols used in this manual to alert the reader:
IDENTIFICATION PLATE
Each portable datalogger has two types of identification plates.
One of these reports the product registration Serial Number and it is positioned on the back side of
the DL.
It is important to communicate the Serial Number of the product when you are
requesting information about it.
The second plate is always located on the back side of the DL.
DL OVERVIEW
Display TFT
DL model
Archimede Datalogger
Keyboard
INTRODUCTION
Depending on the model of your portable DataLogger (DL), it is possible to read different
instruments:
Analog Digital RS485 Probe Vibrating wire
Modbus RTU
Leonardo
New Leonardo
Galileo
Archimede
LEONARDO (0CDL200UN00)
Battery charger
Battery charger
GALILEO (0CDL100VW00)
Battery charger
Rev.4 -04.07.2016- 10 | P a g e
Archimede Portable Dataloggers User Manual
ARCHIMEDE (0CDL300INCL)
Rev.4 -04.07.2016- 11 | P a g e
Archimede Portable Dataloggers User Manual
Flying cables:
• 1 MIL connector and 2 alligator clips + ground (0ECAV7P2A00)
• 1 MIL connector and 4 alligator clips + ground (0ECAV7P4A00)
• 1 MIL connector and 6 alligator clips + ground (0ECAV7P6A00)
• 2 MIL connectors M/F 7 pins (0ECAV07V200)
• IP68 external button for data storage - Archimede DL only (0CDL300REMC)
• Multiplexer measurement (0ECAV10MUX0)
During the transport it is suggested to use the shoulder bag and to avoid bumps.
Rev.4 -04.07.2016- 12 | P a g e
Archimede Portable Dataloggers User Manual
BATTERIES
Each DL is powered by an internal rechargeable NiMh battery.
If properly used, the NiMH batteries have an estimated life of at least 500 discharge cycles.
An effect known as the "memory effect", which could degrade the readout performance during the
use, may occur if batteries are left under charge for some days or if they are repeatedly and
partially discharged. In order to prevent this, it is recommended to use exclusively the battery
charger supplied with the DL and to cycle (charge and fully discharge) the batteries at least once
every two/three weeks.
Batteries should be charged only when they are completely discharged and not
before. You could charge them before only in case of extreme need.
In addition, if the DL is not going to be used for an extended period, it is preferred to store it with
the batteries fully charged.
Well charged batteries provide at least 8 hours of continuous use: this means that batteries
provide charge for more than a working day.
If the DL is not used for several months, batteries lose their capacity due to the
auto-discharge. The first time a battery charger is connected, it could signal green
after few minutes also if the batteries are not fully charged: it is advised to repeat
the charge cycle twice.
Using a good battery, a full battery charge allows a non-stop use of at least 8 hours: this means
that with a full charge it is possible to work on site for more than a working day.
BATTERY CHARGER
The supplied battery charger is controlled by a microprocessor which manages a rapid charge in
less than 3 hours.
The input voltage range is universal (90-264 V ).
This battery charger utilises a method called “–dv detection”; this method is based on the fact that
the voltage drops over the NiMH cells when batteries are fully charged. This voltage drop is
detected when the voltage has decreased of a certain percentage from the highest value and the
charge will be automatically interrupted.
If this voltage drop does not occur, the battery charger has a safety timer which will interrupt the
charge after a certain period of time to avoid batteries overcharging.
If batteries have not been used for a long period of time, the voltage could decrease in the first
part of the charge cycle. For this reason, a start-timer is built into the battery charger to prevent –
dv detection in the first minutes of the charge cycle.
Don’t take instrument readings with battery charger connected to the DL.
Rev.4 -04.07.2016- 13 | P a g e
Archimede Portable Dataloggers User Manual
Don’t use a different type of battery charger than the one supplied
(0ECAB12VNMB)
INTERNAL TEMPERATURE
If the internal temperature of the DL is more than 70°C, there is a safety system
that disconnects the battery until the temperature decreases under 70°C.
Therefore, if after having charge the battery the DL won’t switch on, wait for the
battery cooling until it returns within an adequate temperature range.
The battery charger is activated connecting the jack to the readout and then connecting the
battery charger to the voltage line.
NOTE: To avoid malfunctioning, always insert the jack of the battery charger in
the DL before connecting the battery charger to the voltage line 90-264 VAC, 50-
60Hz. Similarly, before disconnecting the jack of the battery charger from the
readout, disconnect the battery charger from the voltage line.
The LED on the battery charger will be yellow before the fast charge starts and orange when the
carge has started. When the batteries are fully charged the LED will be green.
The battery charge does not remain connected to the DL more than 24 hours.
If the battery voltage is less than the normal one, the LED will indicate "error" by flickering green
and orange light.
LED MODE
Yellow Battery not connected
Yellow Battery initialization and analysis
Orange Fast charge
Green with intermittent yellow flash Top-off charge
Green Trickle charge
Alternating orange – green Error
Connecting the battery charger to the voltage, the LED will be orange for the first 5-7 seconds,
then it turns to yellow when the initialisation and the analysis start. If the battery is connected, the
charge will start a few seconds later, when the LED changes to orange.
When the charge process has ended, the LED will be green in about 4 second. This is only a signal
to test the service. When –dv has been detected, the start of the completion charge is indicated
with a green LED with intermittent yellow flashes. The LED will be green during compensation
charge.
Rev.4 -04.07.2016- 14 | P a g e
Archimede Portable Dataloggers User Manual
KEYBOARD
Rev.4 -04.07.2016- 15 | P a g e
Archimede Portable Dataloggers User Manual
USER INTERFACE
To switch the DL on, press the ON/OFF and INFO key pressed simultaneously, maintaining them
pressed for some second.
After a few seconds (about 5 sec.), the DL will switch on and the display will show the home page.
This page will display the type of DL and the version of the firmware. At the bottom of the display
the name of the DL will be shown up: this is a name assigned to the user, which could be used to
distinguish between different DLs.
Firmware
version
Unit Name
At the upper right corner the display shows the current status of the battery: the remaining charge
is shown by the number of bars.
Rev.4 -04.07.2016- 16 | P a g e
Archimede Portable Dataloggers User Manual
When the battery voltage drops below a certain level, the bar turns red. At
about 10.5V the DL will stop any activity, and the forced turning off is
anticipated by an acoustic signal.
To save battery consumption, after three minutes without any user activity, the
display will be switched off. After ten minutes, the DL will switch off
automatically.
To switch the DL off, press the ON/OFF key while keeping the ENTER key pressed. The DL will
display a window overlapping the current page with a charge bar at the bottom.
When the bar is completely filled, the DL will ask to release all keys and then it will switch off.
Other keys combinations are described in the Special keyboard combinations chapter.
Rev.4 -04.07.2016- 17 | P a g e
Archimede Portable Dataloggers User Manual
The user interface is composed by a series of screens with a structure and a layout similar to the
interface used in Microsoft Windows operating systems.
Screens contain different items such as lists, buttons, text boxes and check or radio buttons.
Only one of the controls on the screen is active: the actual activated control is underlined and,
normally, action is performed pressing ENTER key.
Active control
If the active control is an text control, the characters typed on the keyboard will edit its content.
Rev.4 -04.07.2016- 18 | P a g e
Archimede Portable Dataloggers User Manual
Text control
You could change the active control clicking on the PREVIOUS (scroll) and
NEXT (scroll) keys on the left side of the keyboard.
As all keys, they have an auto-repeat function when held pressed.
All elements of the user interface of the page are in a circular list so that, clicking NEXT (scroll)
when the last control is selected, the selection will move automatically to the first element of the
page. Similarly clicking PREVIOUS (scroll) on the first control, you will move to the last one.
Rev.4 -04.07.2016- 19 | P a g e
Archimede Portable Dataloggers User Manual
TEXT BOXES
A text box is used to display and digit text. When the text to be inserted is a number, either an
integral number of a decimal number, the numeric keys and the decimal point are used to directly
type digits and decimal separators.
The +/- key is used to enter a + or – sign, while the e is used for the exponent.
Pressing the +/- key the DL will show a list of characters. Pressing repeatedly
the +/- key until the character you wish to insert is selected, then wait until
the list of characters disappears and the selected character will be inserted in
the text box.
During the text editing, this insertion typology is valid for each key: press any of these keys
repeatedly to enter the desired character.
Press the DEL key to delete the character at the left of the cursor. If you hold the DEL key pressed
for about a second, the content of the test box will be deleted (quick deleting).
+/- -+()%#
. .,:;
1 1$°εµα/\
2 AB C 2 a b c
3 DEF3def
4 GHI4ghi
5 JKL5jk l
6 MNO6mno
7 PQ R S 7 p q rs
8 TUV8tuv
9 WXYZ9wxyz
0 0 ̺ (space) ! ?
Rev.4 -04.07.2016- 20 | P a g e
Archimede Portable Dataloggers User Manual
BUTTONS
Buttons are used to select an action, which often means navigating to a new screen. Just activate
the desired button and click the ENTER key.
There is any BACK or ABORT button on the screen. To return to the previous screen or abort the
current operation, just press the ESC key on the keyboard.
When no button is selected, the ENTER key is normally used to confirm the most obvious
operation: for example when a list is active, clicking the ENTER key the DL will move to the screen
following the selected item.
LISTS
Lists are used to select one of several items; when a list is active, it is possible to change the
selected item clicking the UP or DOWN keys.
The LEFT key will move to the beginning of the list and the RIGHT key will move to the end.
By clicking ENTER, the current item is selected.
You could delete an item pressing the DEL key when this item is selected, but only if you are in one
of the configuration menus and when a list box is displaying items defined by the user (for example
sites or instruments). The DL requires a confirmation to avoid accidental deleting; this doesn’t
happen if the item has no data inside.
Rev.4 -04.07.2016- 21 | P a g e
Archimede Portable Dataloggers User Manual
RADIO BUTTONS
Radio buttons are used to select one of between several options. To select an item, move the
selection on it clicking NEXT (scroll) or PREVIOUS (scroll) and press ENTER key.
TUNING BACKLIGHT
ONLINE HELP
Rev.4 -04.07.2016- 22 | P a g e
Archimede Portable Dataloggers User Manual
Read inclinometer In this section you could select an inclinometer tube and do a new
inclinometer test.
Show readings In this section you could visualize the results of the inclinometer test
performed on tubes.
Configuration In this section you could create the sites, configure inclinometer tubes and
probes used to perform readings on them.
Communication In this section you could connect to a PC using the USB port.
Utility In this section you could set date and time, select the language for the user
interface and run a checkup for the DL.
Manual reading In this section you could test any configured probe. This may be useful to
check that a probe operates correctly before starting an inclinometer read.
Rev.4 -04.07.2016- 23 | P a g e
Archimede Portable Dataloggers User Manual
CONFIGURING SITES
DLs have a permanent memory used to store configuration data, such as Probes and Inclinometer
Tubes, as well as data acquired from inclinometer tests.
Despite the memory maximum capacity is remarkable (2GB), the export and synchronization speed
of the DL connected to the PC depends on the data quantity.
We suggest to not charge excessively the DL memory and to use it only to save DL
files
All data in a DL are divided in sites: how to define sites is a user responsibility.
However, we advise to name these sites with the real name of the fields sites in
which the measurements are performed.
To view the site list , select Configuration in the main menu, then select Sites. The list of sites is
initially empty. To add a new site, make sure that the text box at the bottom of the screen is active
(you should see a flashing cursor in it) and type the name for the new site, then press ENTER.
Rev.4 -04.07.2016- 24 | P a g e
Archimede Portable Dataloggers User Manual
The name of a site, as well as the name of a Multiplexer, Switch Panel, Work
List or Inclinometer Tube, should be composed of the same characters used
for any valid file name in Microsoft Windows, in other words all the
characters except the following: < > : " / \ | ? *.
To delete a site, select it in the sites list and make sure that the site list is active, then press the DEL
key; if the site is not empty, the DL will ask to confirm the operation.
Rev.4 -04.07.2016- 25 | P a g e
Archimede Portable Dataloggers User Manual
CONFIGURING PROBES
Probes are configured globally on the DL. They are not divided into sites: this
because it is normal for a user to use probes in different sites.
To browse or edit probes, select Configuration in the Main menu, then select Probes.
The list of probes is initially empty. Later you will be able to edit any of the probes simply selecting
the probe and pressing ENTER. To define a new probe, click the New button.
Select the probe type in the list according to the probe you are using (probes type are listed in
paragraph “Instruments list”) and press ENTER.
Rev.4 -04.07.2016- 26 | P a g e
Archimede Portable Dataloggers User Manual
Digital probes require no calibration since all the parameters are already inside the
probe.
Go to paragraph “INCLINOMETER TUBES CONFIGURATION” if you are using a
digital probe.
Rev.4 -04.07.2016- 27 | P a g e
Archimede Portable Dataloggers User Manual
After editing data in this screen, press ENTER. The DL will ask you to select the calibration type.
You should select the calibration type according to the calibration report of the probe.
Rev.4 -04.07.2016- 28 | P a g e
Archimede Portable Dataloggers User Manual
For digital probes, it is necessary to configure only Name, Notes and Decimals since the remainder
of the configuration is saved on probe memory.
If the field “Decimals” is not filled, the DL visualizes automatically a default decimal number
according to the unit of measure of the digital instrument. The number of default and maximum
digits that the DL could visualize is as follows:
For unit of measure which consider a multiplicative of sin(α) different from 1 and from 2000, you
could use a configuration function which allows to have always a different default number for
every multiplicative.
For digital probes no calibration is required because all parameters are already
configured.
With version 0.6.0 for Archimede firmware, new units of measure for digital
probes have been introduced : °, mm/m and in/ft. In addition, it is possible to
read unit of measure different from sin(α) and 20ksin(α).
The recognition of these units of measure is completely automatic, without any
configuration.
The above-mentioned units of measure and the auto-configuration system of
the decimal digits, will not work in firmware version preceding version 0.6.0.
Read paragraph “CONFIGURATION OF INCLINOMETER TUBES” if you are using a digital probe.
Rev.4 -04.07.2016- 29 | P a g e
Archimede Portable Dataloggers User Manual
The type probe calibration is normally used for biaxial inclinometers; this calibration requires two
groups of parameters, one for each axis. The parameters for each axis are the following:
• S: Sensitivity.
• E: Electrical offset.
• M: Mechanical offset.
• X: Cross axis.
• K: Multiplicative factor
The parameter "K" should be coherent with the previously selected unit. If, for example, it has
been selected 20kSen (α) as the unit of measure, it should be inserted 20000 as a parameter "K".
These parameters are used to convert the electrical measurements into physical values: Sin(α) for
example.
where “final” readings take into account the cross axis effect.
NOTE: usually the parameters of probe calibration are inserted by SISGEO if the probe is supplied
together with the DL.
Rev.4 -04.07.2016- 30 | P a g e
Archimede Portable Dataloggers User Manual
The list of available polynomials (degrees) is listed at the top of the screen. Select the polynomial
you wish to use with the UP and DOWN keys: it is possible to select one of the following families
of polynomials:
• Ax+B
• A x2 + B x + C
• A x3 + B x2 + C x + D
Once you selected the polynomial, click the NEXT button to edit the coefficients of the polynomial.
When you have finished the parameters configuration, click the Save button: the newly created
probe will be displayed in the instruments list.
NOTE: Normally the calibration parameters of the probe are set directly from SISGEO if the
probe is supplied with the DL.
Rev.4 -04.07.2016- 31 | P a g e
Archimede Portable Dataloggers User Manual
Tubes defined in the DL include the parameters describing how the physical tubes should be read.
Therefore, it could be necessary to define more tubes for the same physical tube.
For example it is possible to define a spiralometer tube and an inclinometer tube for the same
physical tube, calling them MYTUBE-SP and MYTUBE.
The DL will display a screen to select the site in which the inclinometer tube is or should be
defined; after a site is selected, it will display a list of tubes defined in the site.
When one or more tubes are listed it is possible to delete one of them by selecting it in the list and
pressing the DEL key: the DL will ask the user to confirm this operation.
It is also possible to make a copy of an existing tube by selecting it in the list and clicking the
Duplicate button: the DL will ask the name for the new tube.
The list is initially empty, so that the only possibility is to click the New button.
The DL will display a screen asking the name for the tube.
Rev.4 -04.07.2016- 32 | P a g e
Archimede Portable Dataloggers User Manual
Type the name you wish to use for the new tube and press ENTER:
The DL will ask for data for the new tube; these data include:
Unit: The unit of measure to express the tube length and step length: meters or feet
(from which it is possible to obtain the unit of measure of the axis in graphs
produced by Archimede DL)
Length: The useful length of the tube in the specified unit.
Step: The useful length of the step in the specified unit.
Azimuth: The azimuth of the tube; this parameter may be omitted.
Notes: User notes.
Enter the required data and press ENTER to save the tube definition.
Rev.4 -04.07.2016- 33 | P a g e
Archimede Portable Dataloggers User Manual
In case DL switches off during an inclinometer test, for example for a low battery, the readings
that have already been performed are saved. However, the inclinometer file closes, so it will be no
possible to perform other readings to complete the test. Anyway, it will be possible to delete the
partial test and repeat it in future.
Click Read inclinometer in the Main menu, then select the site in which the inclinometer tube is
located. The DL will show the list of the tubes defined in the site.
Select the tube you wish to use and press ENTER to proceed.
The DL will ask you to enter the number for the test, showing as pre-configured value the first
number available.
Enter a new number or simply press ENTER to proceed. You could perform up to 99 test on the
same tube.
Then the DL will ask you to specify some options on how the test should be performed. This screen
is not displayed for T-REX tests because these options are meaningless in this case.
First, you should specify if the readings should be triggered manually or automatically after a pre-
configured delay.
Then you should select if the runs should be performed from the head to the end of the tube or
from the end to the head.
If you need to do spiralometer test, the system doesn’t ask you this because in these tests you
have to perform the first run “From head to end” and then to perform a run “From end to head”.
Rev.4 -04.07.2016- 35 | P a g e
Archimede Portable Dataloggers User Manual
In the following pages, the DL will ask which test should be used as a reference test. We suggest to
select the first test in the list (labeled 00). Therefore, it is possible to select any test from the list or
to click the No reference button to perform an absolute test.
The values of the reference test will be displayed during the performance of the next test. They
will also be used for graphs elaboration.
The above mentioned page will not be shown in the spiralometer test, since it is not possible to
choose the reference test.
At this point, all the parameters for the data performance have been configured. The DL will ask
which run to do firstly. The number and the type of the runs depend from the type of test:
A1B1/A3B3 An A1B1 run is performed, then the probe is extracted and rotated of
180º and an A3B3 run is performed.
A2B2/A4B4 An A2B2 run is performed, then the probe is extracted and rotated of
180º and an A4B4 run is performed.
A1B1/A2B2/A3B3/A4B4 Runs A1B1, A2B2, A3B3 and A4B4 are performed in sequence;
between each run and the next the probe is extracted and rotated 90º.
Spiralometer A head to bottom run is performed; normally a second bottom to
head run is performed.
TREX A bottom to head run is performed first; sometimes a second head to
bottom run is performed next.
These sequences are those normally performed. Anyway, you could choose to perform runs in the
order you prefer.
Rev.4 -04.07.2016- 36 | P a g e
Archimede Portable Dataloggers User Manual
The DL will suggest the first run to perform. At the end of each run, the DL will suggest the next
run. It is possible to interrupt the test at the end of a run by selecting Save and exit and pressing
ENTER.
INCLINOMETER TESTS
During the execution of a test, what is displayed in the central part of the screen depends on the
type of test. However, the upper part and the left part of the screen shows items common to all
tests.
In the upper part of the screen the Name of the probe being used and the Name of the tube are
shown. On the left the Current date and time and the Measure unit are shown. Four buttons are
also present:
It is possible to stop the test at any time. Pushing the ESC key, a confirmation request will appear.
If you confirm, the test will be deleted. Differently, holding the ESC key pushed for a few seconds,
the data will be saved and the test will be partial. You may also abort the test at any time by
pressing the ESC key: in this case no data will be saved.
During the inclinometer test, you could save a read using the external button (0CDL300REMC). This
button has the same function as the Save button. To prevent the user from inadvertently triggering
multiple readings, the external button is disabled for two seconds after each push. We advise to
wait at least three seconds between each pushing.
Rev.4 -04.07.2016- 37 | P a g e
Archimede Portable Dataloggers User Manual
You may also view data in graphical form, for inclinometer and T-REX tests: just press ENTER when
the table is displayed.
When the last read for the current run has been performed, the DL will display again the list of the
runs with the next run (corresponding run) preselected. It is also possible to select “save and exit”
to stop early the runs.
MEASURE UNIT
CHECK SUM VALUES
The top blue box displays the Check Sum values for both channels. These are the semi-sums of the
value read for the channel in the current run and in the corresponding run (A1B1 for A3B3 and
A2B2 for A4B4) at the current level, that is:
The readings of the corresponding runs should have almost identical values with an opposite sign,
so when the second of the corresponding run is performed, the check-sum values could be near to
zero. These values are available only when the corresponding reading has already been done.
The bottom blue box shows the Reference values, that are the values read in the same run and at
the same depth of the reference test and, on the right, the Current level in the tube.
The color of the unit of measurement shown in the left part of the screen alternates from black to
blue every time reading values are updated.
Rev.4 -04.07.2016- 38 | P a g e
Archimede Portable Dataloggers User Manual
When digital probe are used, it is possible to read the temperature taken inside the probe board.
To display the temperature press the Right Arrow Key, to return to the unit of measurements
press Left Arrow key.
Click Measure to record the values and proceed to the next step.
With version 0.6.0 of Archimede firmware it has been introduced the auto-
dimensioning of the font of inclinometer reading visualization, according to
decimal digits.
For this reason, the size of the read numbers could vary.
If the DL finds an incompatibility with the digital instrument (i.e. it has been selected a mono-axial
digital probe while the connected probe is bi-axial) a dialog-box will be shown:
Pushing Abort the user interrupts the inclinometer test without saving any data. Pushing Continue
the user returns to the inclinometer test screen in order to re-do it. Pushing Save the user saves
the data that have been registered.
From firmware version 0.6.0 it has been introduced new log for the
measurements that are out of range. These measurements appear as “+OFV”
or “-OFV”, in case the value exceeds in positive or negative the electric range
of measure.
Rev.4 -04.07.2016- 39 | P a g e
Archimede Portable Dataloggers User Manual
If the DL can’t read the connected digital probe a dialog box will be shown:
Pushing Abort, the user interrupts the inclinometer test without saving any data. Pushing
Continue, the user returns to the inclinometer test screen in order to re-perform it. Pushing Save,
the user saves the data that have been registered.
In this case check the connections between the DL and the inclinometer probe.
Rev.4 -04.07.2016- 40 | P a g e
Archimede Portable Dataloggers User Manual
SPIRALOMETER TESTS
When performing a spiralometer test, the screen looks as follows:
MEASURE UNIT
CHECK SUM VALUES
CURRENT LEVEL
The top blue box displays the Check sum value; it is the halved sum of the current run and the
matching run at the current level. The corresponding readings should be approximately identical
but with opposite sign, so that the check-sum value should be close to zero; this value is only
available when the matching run has already been performed.
The bottom blue box shows the Current level in the tube.
Rev.4 -04.07.2016- 41 | P a g e
Archimede Portable Dataloggers User Manual
T-REX TEST
When performing a TREX test, the screen looks as follows:
MEASURE UNIT
CURRENT VALUES IN mV
The top blue box displays the Current values read in mV on both channels of the TREX probe.
When a ring is detected, both values are include in a range between 1000mV and 9000mV.
The bottom blue box displays the Current Level of the probe inside the tube and the Reference
value read in the same run and at the same depth of the reference test.
At the center the current value is shown. This is displayed only when both rings have been
detected: a single value is calculated from the two channels of the T-REX. The values read on the
two channels are converted in millimeters and their difference is shown.
Rev.4 -04.07.2016- 42 | P a g e
Archimede Portable Dataloggers User Manual
When a valid value is displayed, you could click the Read button to record the current value.
The DL will store the value and get ready for the next level.
It is possible to visualized data of an inclinometer test at any moment during the test, pushing the
Data button in the window.
From the Main menu, you could visualize the acquired data for any test. Select Show readings in
the Main menu.
The DL will first ask you to select the site, then the inclinometer tube. At this point, a list of tests
performed on the tube will be shown.
You could delete tests from this window by pressing the DEL key. The DL will
ask you to confirm the operation.
Select the test you wish to browse and click ENTER. The DL will display all the data acquired in a
single run.
Rev.4 -04.07.2016- 43 | P a g e
Archimede Portable Dataloggers User Manual
To view data of other runs, press the PREVIOUS (scroll) and NEXT (scroll) keys.
When the user performs an inclinometer test, it is necessary to make a distinction between the
reference test (usually the first test performed, which measures are therefore absolute) and the
other tests in which, what matters is usually the difference between the current values and the
values recorded in the reference test (relative measures).
The graphs for these two options are slightly different.
The graph for the reference test on the left is labeled as ABSOLUTE, while the graphs for the other
tests display a label indicating the test being used as reference. The reference test (or the fact that
a test is absolute) is selected when starting the test and cannot be changed later.
In the absolute graph on the left the blue line represents the inclinometer tube as seen from the
top (the center corresponds to the start of the tube).
In the relative graph the offset of the reference test is subtracted before drawing the graph and
the line represents the movement of the tube from the original position as seen from the bottom
(the center corresponds to the end of the tube
Rev.4 -04.07.2016- 44 | P a g e
Archimede Portable Dataloggers User Manual
Push ENTER again to view a different representation of the same data. This time the line
represents the displacement of the tube from the vertical line for the first absolute graph and
from the reference measurement for the second relative graph.
Again, the reference zero is the top of the tube for the first graph and the bottom for the second.
Please note that only the absolute value of the displacement is represented. Direction is not
represented. Refer to the first graph to view the direction of the displacement.
In all the case it is displayed only a line for each tube: in case more runs have been performed,
their values are put together to obtain a single value represented in the graph.
In case of relative graphs, all the available runs from both the reference test and the current test
are used. For example, if runs A1B1/A2B2/A3B3/A4B4 have been performed in the reference test
and runs A1B1/A3B3 have been performed in the current test, only runs A1B1/A3B3 of both
graphs will be used.
Press ENTER again to view the same data in tabular form again.
Rev.4 -04.07.2016- 45 | P a g e
Archimede Portable Dataloggers User Manual
Rev.4 -04.07.2016- 46 | P a g e
Archimede Portable Dataloggers User Manual
T-REX Graph
When the user performs a T-REX inclinometer test, it is necessary to make a distinction between
the reference test (usually the first test performed, which measures are therefore absolute) and
the other tests in which, what matters is usually the difference between the current values and
the values recorded in the reference test (relative measures).
The graphs for these two options are slightly different.
The graph for the reference test on the left is labeled as ABSOLUTE, while the graphs for the other
tests display a label indicating the test being used as reference. The reference test (or the fact that
a test is absolute) is selected when starting the test and cannot be changed later.
In the absolute graph on the left the blue line represents the difference between the distance of
the reference magnetic rings and the ideal value of one meter.
In the relative graph the offset of the reference test is subtracted before drawing the graph and
the line represents the lengthening of the tube at each depth from the original state.
If both an UP and a DOWN runs have been performed, they will be drawn as different lines (blue
for UP and green for DOWN).
For relative graphs a line is drawn only if the relative data is available both in the current and in
the reference test.
Rev.4 -04.07.2016- 47 | P a g e
Archimede Portable Dataloggers User Manual
MANUAL READING
You may read probes without starting a new test, in order to check that they are correctly
working. Select Manual Reading in the Main menu, then select the probe you wish to test. The DL
will show the values being read.
During the reading of a digital probe, pressing the RIGHT key it is possible to display the
temperature revealed on the electronic board of the same probe.
Reading
Rev.4 -04.07.2016- 48 | P a g e
Archimede Portable Dataloggers User Manual
If the DL finds an incompatibility with the digital instrument (i.e. it has been selected a mono-axial
digital probe while the connected probe is bi-axial) a dialog-box will be shown :
If the DL can’t read the connected digital probe a dialog box will be shown:
Rev.4 -04.07.2016- 49 | P a g e
Archimede Portable Dataloggers User Manual
This same connector is used to connect the external button used to save
instruments readings. These two uses are not compatible: when an external
button is connected, the USB cable cannot be used and connecting an USB cable
when the DL expects a button will cause the PC to issue a warning stating that
the USB detection failed.
The first time Smart Manager interfaces with the DL, it could be necessary to wait
few minutes for the synchronization.
Rev.4 -04.07.2016- 50 | P a g e
Archimede Portable Dataloggers User Manual
Rev.4 -04.07.2016- 51 | P a g e
Archimede Portable Dataloggers User Manual
Click the Remote management button. The DL will display the initial splash screen.
When it starts, click the Connect button at the top of the displayed window on the PC:
Rev.4 -04.07.2016- 52 | P a g e
Archimede Portable Dataloggers User Manual
When you use SmartRemote, the DL is slightly slower than usual. This is normal and it is due to the
fact that the screen must be transmitted to the PC.
The DL is fully operative when it is used with SmartRemote, except for the USB
Disk and USB Calibration. These functions in the Communication menu are
disabled.
In addition, during the instruments readings, the external button could not be
used.
Click Remote management off button in the Communication menu to terminate SmartRemote mode.
Rev.4 -04.07.2016- 53 | P a g e
Archimede Portable Dataloggers User Manual
UTILITIES
The utilities menu includes commands necessary to set the DL clock, to run a self-test and to
change the user interface language. Click the Utility button in the main menu.
To change the current date and time click one of the arrow keys. Initially, a cursor will be displayed
on the first digit of the hours field.
Rev.4 -04.07.2016- 54 | P a g e
Archimede Portable Dataloggers User Manual
You could move the cursor using the arrow keys or change the present data/time typing the new
value using the numeric keys.
When you have finished to edit, you may either commit the new value by pressing ENTER or
discard with ESC.
CHECKING DL STATUS
Click the Unit status button in the Utilities menu to check the current status. The DL will display a
list of the tests being performed and mark each test for success or failure.
No key should be pressed during the DL self-test. Therefore, if you hold a key
pressed. the keyboard test will fail.
Rev.4 -04.07.2016- 55 | P a g e
Archimede Portable Dataloggers User Manual
The DL will return to the previous screen with the newly selected language.
If you find a DL set in language that you cannot understand, from any screen of the user interface
press ESC for a few seconds till the DL reverts to the main menu, then press the 5 button followed
by the 3 button, then select your language.
Rev.4 -04.07.2016- 56 | P a g e
Archimede Portable Dataloggers User Manual
TROUBLE SHOOTING
Problem Cause Recommended action
A connector from the DL internal battery Connect the battery-charger and try to turn the DL
DL does not switch on
disconnected on. If the DL turns on contact SISGEO's assistance
Battery's temperature overcomes 70°C, Wait at least 30 minutes to allow the battery to
internal security system stops the power become colder and go back in the appropriate
circuit temperature range
Check DL battery level ( available in menu Utilities -> Unit Status d irectly on DL )
The battery is not correctly recharged. Battery-recharger LED The battery-charger could have not correctly Repeat the charge procedure, checking the LED colour
does not perform the foreseen colorur sequence ( as in DL sequence. Insert always first the jack in the DL and
detected the battery
manual) then the plug in the network plug
Battery's temperature overcomes 70°C, Wait at least 30 minutes to allow the battery to
internal security system stops the power become colder and go back in the appropriate
circuit temperature range
DL showed "Calibration file is not valid" The calibration file is lost or damaged Call SISGEO for assistance
The connections to the instruments are Reconnect the instrument properly and repeat the
incorrect reading
Rev.4 -04.07.2016- 57 | P a g e
Archimede Portable Dataloggers User Manual
The MEMS inclinometer sensor of the digital Bring the probe within the limits of the inclinometer
DL displays the message "+OVF"
probe is out of the electric range range
The MEMS inclinometer sensor of the digital Bring the probe within the limits of the inclinometer
DL display the message "-OVF"
probe is out of the electric range range
Rev.4 -04.07.2016- 58 | P a g e
Archimede Portable Dataloggers User Manual
ASSISTANCE
Sisgeo S.r.l. is aware of the importance covered by the after-sales assistant service, therefore
Sisgeo Technical Support is structured to offer the following services:
RECALIBRATION
SISGEO suggests the recalibration of portable datalogger every 2 years from the purchase date o
from the last recalibration.
Recalibration could be done only by SISGEO at its laboratory.
Repairs and/or recalibrations should always be carried out at SISGEO factory or by personnel
trained and authorized by SISGEO. In case of repair and/or recalibration please send us the
device and every accessory in the container provided, in order to prevent damage from shocks
during transport.
This procedure involves the filling out of the form on our website "www.sisgeo.com" to the link
"assistance - repairs"; once inserted the request, a confirmation with the related authorization
code will be sent to the e-mail address indicated.
The material has to be packed properly and sent in door to door basis (freight to
client charge) to:
SISGEO S.r.l.
Via F. Serpero, 4/F1 - 20060 MASATE (MI)
Attn. to Technical Assistance Office
Tel. +39-02-95764130 - Fax: +39-02-95762011 - e-mail: assistance@sisgeo.com
PHONE ASSISTANCE
Telephone support for installation, configuration of equipment, measurement systems and
Software.
TRAINING
Possibility of training at our Factory or at site related to the installation procedures, the system
configuration and the use of measurement systems.
Rev.4 -04.07.2016- 59 | P a g e
Archimede Portable Dataloggers User Manual
INSTRUMENTS LIST
PROBES/DIGITAL PROBES
CODE NAME SUPPLY SIGNAL UNIT DECIMAL
T-REX removable
REX451XX ±12V 10000mV mm 2
extensometer
Digital horizontal
S241DH30 inclinometer probe 24V digital 20000 Sinα 0
±30°
Mono-axial digital
S241DV30 24V digital 20000 Sinα 0
probe
Horizontal
S241HH30 inclinometer probe ±12V ±5000mV Degrees 0
±30°
S241SHXX Horizontal probe ±12V ±5000mV Degrees 0
Digital horizontal
S242DH30 inclinometer probe 24V digital 20000 Sinα 0
±30°
Biax Digital
S242DVXX 24V digital 20000 Sinα 0
inclinometer probe
S242HVXX Inclinometer probe ±7V ±5000mV 20000 Sinα 0
S242SHXX Horizontal probe ±12V ±5000mV Degrees 0
Servo-inclinometer
S242SVXX ±12V ±5000mV 20000 Sinα 0
probe
S30PR12X Spiralmeter probe ±2.5V ±400mV Degrees 2
Tilt probe for cased
S310PV2X ±2.5V ±5000mV 20000 Sinα 0
borehole
Tilli portable
SCLIN45X ±12V ±5000mV Degrees 3
tiltmeter
Rev.4 -04.07.2016- 60 | P a g e
Portable Dataloggers User Manual
SWITCH OFF
To switch the DL off, keep the ON/OFF key pressed
and press the ENTER key till the DL switches off.
EMERGENCY RESET
Should the DL become unresponsive, press the keys
OFF and DEL keys at the same time: the DL should
reset immediately.
FIRMWARE UPGRADE
To upgrade firmware, switch the DL off, then press
the following keys at the same time: 1, 3, 9 and
ENTER. While keeping them pressed press the
ON/OFF key till the DL switches on.
The DL will display a blue screen and will be ready for
firmware upgrade.
Read “Smart Manager” manual for detail
Rev.4 -04.07.2016- 61 | P a g e
Portable Dataloggers User Manual
If, for example, with a new firmware, it has been changed the power supply of a instrument, this
one will be powered with the power supply set in the old firmware. If you want to use the new
power supply it is necessary to remove the instrument from the datalogger and re-insert it
Rev.4 -04.07.2016- 62 | P a g e