Plastics piping systems for


water supply, and for
drainage and sewerage under
pressure — Polyethylene (PE)
http://qstandard.org/
Part 1: General
BS EN 12201-1:2011 BRITISH STANDARD

National
Nationalforeword
foreword
This British Standard is the UK implementation of EN 12201-1:2011.
ItThis British Standard
supersedes is the UK implementation
BS EN 12201-1:2003 of EN 12201-1:2011.
and BS EN 13244-1:2002, which are
It supersedes BS EN 12201-1:2003 and BS EN 13244-1:2002 which are
withdrawn.
withdrawn.
NOTE 1 There is no Part 6 in the EN 12201 series. Instead users of the BS EN 12201
NOTE
series 1 refer
should There tois no Part
Water 6 in Specification
Industry the EN 12201 series.
(WIS), Instead
4-32-08 users of
Specification for
thefusion
the BS EN 12201
jointing of series shouldpressure
polyethylene refer topipeline
Water systems
Industry Specification
using PE80 and PE100
materials, obtainable
(WIS), 4-32-08 from www.water.org.uk.
Specification for the fusionInjointing
addition,ofguidance provided by
polyethylene
the manufacturer
pressure of the
pipeline pipes and
systems fittings
using PE80 should be followed.
and PE100 materials, obtainable
from www.water.org.uk. In addition, guidance provided by the
NOTE 2 Part 7 of the EN 12201 series has been prepared as a CEN/TS to allow
manufacturer
further of theCEN/TS
development. pipes12201-7
and fittings
is not should be followed.
mandatory under the Public
Procurement Directives (2004/18/EC and 2004/17/EC).
NOTE 2 Part 7 of the EN 12201 series has been prepared as a CEN/
As
TSyet
to there
allow is no pan-European
further development.agreement on waterisquality
CEN/TS 12201-7 not mandatory
requirements, so existing
under the Public UK regulations
Procurement Directivesremain in forceand
(2004/18/EC for 2004/17/EC).
public
drinking water suppliers.
As yet there is no pan-European agreement on water quality
The following regulations
requirements, so existingapply to the approval
UK regulations of substances
remain andpublic
in force for
products used in the provision
drinking water suppliers. of public water supplies within
the United Kingdom:

a)TheEngland
following regulations
– Regulation 31apply
of Theto the approval
Water of substances
Supply (Water Quality) and
products
Regulations 2000 (Statutory Instruments 2000 No 3184)within the
used in the provision of public water supplies
United Kingdom:
b) Wales – Regulation 31 of The Water Supply (Water Quality)
Regulations
a) England 2001 (Welsh
- Regulation 31 Statutory Instrument
of The Water Supply2001 No 3911
(Water (W.323)
Quality)
Regulations 2000 (Statutory
c) Scotland – Regulation 27 of The Water Supply (Water Quality)
Instruments
(Scotland)2000 No 3184)
Regulations 2001

http://qstandard.org/
d)b) Wales
Northern Ireland – Regulation
– Regulation
Quality) (Amendment)
Regulations
(Statutory
Statutory
31 of The 30

Rules of 2001
Instrument Northern
of The
Water

Ireland
No 3911
Water
Supply SupplyQuality)
(Water (Water
2001 (Welsh Regulations (Northern Ireland) 2009
2009 No.246).
(W.323)
For further information, go to: http://www.legislation.gov.uk/browse
c) Scotland – Regulation 27 of The Water Supply (Water Quality)
(Scotland)
As Regulations
part of the regulations,2001
all pipes and fittings used to convey drinking
water supplies are required to be approved under the provisions of
d) Northern
Regulation 31,Ireland – Regulation
as applicable. 30 ofmanufacturers
In addition, The Water Supply (Water
may obtain
Quality) (Amendment)
approval under the Water Regulations Advisory Scheme (WRAS) to
Regulations
confirm (Northern
that use Ireland) 2009
of their products (Statutory
will not Rules effect
cause adverse of Northern
on water
Ireland 2009 No.246)
quality or a risk to health of consumers.

National Annex
For further NA providesgo
information, additional information on the selection and
to: http://www.legislation.gov.uk/browse
installation of piping systems and components in the UK.
As part of the regulations, all pipes and fittings used to convey
Attention is drawn to the following statutory regulation: Health & Safety
drinking water supplies are required to be approved under
at Work etc. Act 1974, and subsequent regulations.
the provisions of Regulation 31, as applicable. In addition,
manufacturers
The requirementsmay obtaininapproval
contained under
the EN 12201 the of
series Water Regulations
standards are not
Advisory Scheme (WRAS) to confirm that use of their products will
necessarily indicative of all the performance requirements, or the suitability
not cause adverse effect on water quality or a risk to health of
of pipework for the service conditions, likely to be encountered in the UK.
consumers.
The UK participation in its preparation was entrusted by
Technical
NationalCommittee
Annex NAPRI/88, Plastics
provides piping information
additional systems, to on the selection
and installation
subcommittee of piping
PRI/88/2, systems
Plastics pipingand
for components in the UK.
pressure applications.

AAttention
list of organizations
is drawn to represented on this
the following subcommittee
statutory can be
regulation: obtained
Health &
on request to its secretary.
Safety at Work etc. Act 1974, and subsequent regulations.

The requirements contained in the EN 12201 series of standards are


not necessarily indicative of all the performance requirements, or
the suitability of pipework for the service conditions, likely to be
encountered in the UK.
The UK participation in its preparation was entrusted to Technical
Committee PRI/88/2, Plastics piping for pressure applications.
BS EN 12201-1:2011 BRITISH STANDARD

Alist of organizations represented on this committee can be


obtained on request to its secretary.
This publication does not purport to include all the necessary
provisions of a contract. Users are responsible for its correct
application.
© BSI 2011
ISBN 978 0 580 69589 6
ICS 23.040.01; 91.140.60; 93.030
Compliance with a British Standard cannot confer immunity from
legal obligations.
This British Standard was published under the authority of the
Standards Policy and Strategy Committee on 30 November 2011.
Amendments issued since publication
Date Text affected

http://qstandard.org/
BS EN 12201-1:2011

EUROPEAN STANDARD EN 12201-1


NORME EUROPÉENNE
EUROPÄISCHE NORM September 2011

ICS 23.040.01 Supersedes EN 12201-1:2003, EN 13244-1:2002

English Version

Plastics piping systems for water supply, and for drainage and
sewerage under pressure - Polyethylene (PE) - Part 1: General

Systèmes de canalisations en plastique pour l'alimentation Kunststoff-Rohrleitungssysteme für die Wasserversorgung


en eau et pour les branchements et les collecteurs und für Entwässerungs- und Abwasserdruckleitungen -
d'assainissement avec pression - Polyéthylène (PE) - Polyethylen (PE) - Teil 1: Allgemeines
Partie 1: Généralités

This European Standard was approved by CEN on 8 July 2011.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.

This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same
status as the official versions.

http://qstandard.org/
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.

EUROPEAN COMMITTEE FOR STANDARDIZATION


COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG

Management Centre: Avenue Marnix 17, B-1000 Brussels

© 2011 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 12201-1:2011: E
worldwide for CEN national Members.
BS EN 12201-1:2011
EN 12201-1:2011 (E)

Contents Page

Foreword ...................................................................................................................................................................... 3 !
Introduction ................................................................................................................................................................. 4!
1! Scope.................................................................................................................................................................... 5!
2! Normative references ......................................................................................................................................... 5 !
3! Terms and definitions, symbols and abbreviations ........................................................................................ 7!
3.1! Terms and definitions ...................................................................................................................................... 7!
3.1.1! Geometrical characteristics .......................................................................................................................... 7!
3.1.2! Material definitions ........................................................................................................................................ 9!
3.1.3! Definitions related to material characteristics ............................................................................................ 9!
3.1.4! Definitions related to service conditions................................................................................................... 10!
3.1.5! Definitions related to joints ......................................................................................................................... 10!
3.2! Symbols .......................................................................................................................................................... 11 !
3.3! Abbreviations ................................................................................................................................................. 12!
4! Compound ......................................................................................................................................................... 12!
4.1! Material of the components .......................................................................................................................... 12!
4.2! Additives ......................................................................................................................................................... 12 !
4.3! Colour .............................................................................................................................................................. 12!

http://qstandard.org/
4.4! Characteristics ............................................................................................................................................... 13 !
4.4.1! Characteristics of the compound in the form of granules ...................................................................... 13!
4.4.2! Characteristics of the compound in the form of pipe .............................................................................. 14!
4.5! Fusion compatibility for PE 80 and PE 100 materials ................................................................................ 16!
4.6! Classification and designation ..................................................................................................................... 17!
5! Effect on water quality ...................................................................................................................................... 17!
Annex A! (normative) Pressure reduction coefficients ....................................................................................18!
Bibliography .............................................................................................................................................................. 19 !

2
BS EN 12201-1:2011
EN 12201-1:2011 (E)

Foreword
This document (EN 12201-1:2011) has been prepared by Technical Committee CEN/TC 155 “Plastics piping
systems and ducting systems”, the secretariat of which is held by NEN.

This European Standard shall be given the status of a national standard, either by publication of an identical text or
by endorsement, at the latest by March 2012, and conflicting national standards shall be withdrawn at the latest by
March 2012.

Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights.
CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights.

This document supersedes EN 12201-1:2003, EN 13244-1:2002.

System Standards are based on the results of the work being undertaken in ISO/TC 138 "Plastics pipes, fittings
and valves for the transport of fluids", which is a Technical Committee of the International Organization for
Standardization (ISO).

They are supported by separate standards on test methods to which references are made throughout the system
Standard.

The System Standards are consistent with general standards on functional requirements and on recommended
practice for installation.

EN 12201 consists of the following Parts:

 EN 12201-1, Plastics piping systems for water supply, and for drainage and sewerage under pressure —

http://qstandard.org/
Polyethylene (PE) — Part 1: General (this standard);

 EN 12201-2, Plastics piping systems for water supply, and for drainage and sewerage under pressure —
Polyethylene (PE) — Part 2: Pipes;

 EN 12201-3, Plastics piping systems for water supply, and for drainage and sewerage under pressure —
Polyethylene (PE) — Part 3: Fittings;

 EN 12201-4, Plastics piping systems for water supply, and for drainage and sewerage under pressure —
Polyethylene (PE) — Part 4: Valves for water supply systems;

 EN 12201-5, Plastics piping systems for water supply, and for drainage and sewerage under pressure —
Polyethylene (PE) — Part 5: Fitness for purpose of the system;

 CEN/TS 12201-7, Plastics piping systems for water supply — Polyethylene (PE) — Part 7: Guidance for the
assessment of conformity.

This revision is a merger of both EN 12201-1:2003 and EN 13244-1:2003. The test methods referenced have been
changed or updated as appropriate. The requirements for resistance to slow crack growth in accordance with EN
ISO 13479 have been increased, and the rating of dispersion for pigment and carbon black dispersion in
accordance with ISO 18553 has been added.

According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden,
Switzerland and the United Kingdom.

3
BS EN 12201-1:2011
EN 12201-1:2011 (E)

Introduction
The System Standard, of which this is Part 1, specifies the requirements for a piping system and its components
when made from polyethylene (PE). The piping system is intended to be used for water supply intended for human
consumption, including the conveyance of raw water prior to treatment, drainage and sewerage under pressure,
vacuum sewer systems, and water for other purposes.

In respect of potential adverse effects on the quality of water intended for human consumption, caused by the
products covered by EN 12201 (all parts):

a) this standard provides no information as to whether the products may be used without restriction in any of the
Member States of the EU or EFTA;

b) products intended for use in water supply systems must comply, when existing, with national regulations and
testing arrangements that ensure fitness for contact with drinking water.

NOTE On April 2006, EC Commission set up a revised mandate (M/136) asking CEN to propose harmonised product
standards and support standards for test methods which could be used for assessing the fitness for contact with drinking water.
In parallel, EC Commission has launched processes for a regulation of construction products (CPR) to be substituted to CP
directive (89/106/EEC) and for the revision of drinking water directive (98/83/EC). If relevant, when the outputs of these
processes will be known, European Product Standards will be amended by the addition of an Annex Z under Mandate M136
which will contain formal references to the applicable requirements. Until such amendments, the current national regulations
remain applicable.

http://qstandard.org/
Requirements and test methods for components of the piping system are specified in EN 12201-2:2011, EN 12201-
3:2011 and prEN 12201-4:2011.

Characteristics for fitness for purpose are covered in EN 12201-5:2011.[1] CEN/TS 12201-7 [2] gives guidance on
the assessment of conformity.

This Part of EN 12201 covers the general aspects of the plastics piping system.

4
BS EN 12201-1:2011
EN 12201-1:2011 (E)

1 Scope
This part of EN 12201 specifies the general aspects of polyethylene (PE) pressure piping systems (mains and
service pipes) for buried or above ground applications, intended for the conveyance of water for human
consumption, raw water prior to treatment, drainage and sewerage under pressure, vacuum sewer systems, and
water for other purposes.

NOTE 1 For PE components intended for the conveyance of water intended for human consumption and raw water prior to
treatment attention is drawn to Clause 5 of this European Standard. Components manufactured for water for other purposes,
drainage and sewerage may not be suitable for water supply for human consumption.

It also specifies the test parameters for the test methods referred to in this standard.

In conjunction with Parts 2 to 5 of EN 12201, it is applicable to PE pipes, fittings, valves, their joints and to joints
with components of other materials intended to be used under the following conditions:

a) allowable operating pressure, PFA, up to 25 bar 1);

b) an operating temperature of 20 °C as a reference temperature;

c) buried in the ground;

d) sea outfalls;

http://qstandard.org/
e) laid in water;

f) above ground, including pipes suspended below bridges.

NOTE 2 For applications operating at constant temperatures greater than 20 °C and up to 40 °C, see Annex A.

EN 12201 (all parts) covers a range of allowable operating pressures and gives requirements concerning colours
and additives.

NOTE 3 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into
account their particular requirements and any relevant national guidance or regulations and installation practices or codes.

2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references,
only the edition cited applies. For undated references, the latest edition of the referenced document (including any
amendments) applies.

EN 12099, Plastics piping systems — Polyethylene piping materials and components — Determination of volatile
content

EN 12201-2:2011, Plastics piping systems for water supply, and for drainage and sewerage under pressure —
Polyethylene (PE) — Part 2: Pipes

EN 12201-3, Plastics piping systems for water supply, and for drainage and sewerage under pressure —
Polyethylene (PE) — Part 3: Fittings

1) 1 bar = 0,1 MPa = 105 Pa; 1 MPa = 1 N/mm2.

5
BS EN 12201-1:2011
EN 12201-1:2011 (E)

prEN 12201-4:2011, Plastics piping systems for water supply, and for drainage and sewerage under pressure —
Polyethylene (PE) — Part 4: Valves for water supply systems

EN ISO 472:2001, Plastics —Vocabulary (ISO 472:1999)

EN ISO 1043-1:2001, Plastics – Symbols and abbreviated terms — Part 1: Basic polymers and their special
characteristics (ISO 1043-1:2001)

EN ISO 1133, Plastics — Determination of the melt mass-flow rate (MFR) and the melt volume-flow rate (MVR) of
thermoplastics (ISO 1133:2005)

EN ISO 1167-1, Thermoplastics pipes, fittings and assemblies for the conveyance of fluids — Determination of the
resistance to internal pressure — Part 1: General method (ISO 1167-1:2006)

EN ISO 1167-2, Thermoplastics pipes, fittings and assemblies for the conveyance of fluids — Determination of the
resistance to internal pressure — Part 2: Preparation of pipe test pieces (ISO 1167-2:2006)

EN ISO 1183-1, Plastics — Methods for determining the density of non-cellular plastics — Part 1: Immersion
method, liquid pyknometer method and titration method (ISO 1183-1:2004)

EN ISO 1183-2, Plastics — Methods for determining the density of non-cellular plastics — Part 2: Density gradient
column method (ISO 1183-2:2004)

EN ISO 6259-1, Thermoplastics pipes — Determination of tensile properties — Part 1: General test method
(ISO 6259-1:1997)

prEN ISO 9080, Plastics piping and ducting systems — Determination of the long-term hydrostatic strength of
thermoplastics materials in pipe form by extrapolation (ISO/DIS 9080:2010)

http://qstandard.org/
EN ISO 12162, Thermoplastics materials for pipes and fittings for pressure applications — Classification,
designation and design coefficient (ISO 12162:2009)

EN ISO 13477, Thermoplastics pipes for the conveyance of fluids — Determination of resistance to rapid crack
propagation (RCP) — Small-scale steady-state test (S4 test) (ISO 13477:2008)

EN ISO 13478, Thermoplastics pipes for the conveyance of fluids — Determination of resistance to rapid crack
propagation (RCP) — Full-scale test (FST) (ISO 13478:2007)

EN ISO 13479, Polyolefin pipes for the conveyance of fluids — Determination of resistance to crack propagation —
Test method for slow crack growth on notched pipes (ISO 13479:2009)

EN ISO 15512, Plastics ! Determination of water content (ISO 15512:1999)

EN ISO 16871, Plastics piping and ducting systems ! Plastics pipes and fittings ! Method for exposure to direct
(natural) weathering (ISO 16871:2003)

ISO 6259-3, Thermoplastics pipes — Determination of tensile properties — Part 3: Polyolefin pipes

ISO 6964, Polyolefin pipes and fittings — Determination of carbon black content by calcination and pyrolysis —
Test method and basic specification

ISO 11357-6, Plastics — Differential scanning calorimetry (DSC) — Part 6: Determination of oxidation induction
time (isothermal OIT) and oxidation induction temperature (dynamic OIT)

ISO 11413:2008, Plastics pipes and fittings — Preparation of test piece assemblies between a polyethylene (PE)
pipe and an electrofusion fitting

ISO 11414:2009, Plastics pipes and fittings — Preparation of polyethylene (PE) pipe/pipe or pipe/fitting test piece
assemblies by butt fusion

6
BS EN 12201-1:2011
EN 12201-1:2011 (E)

ISO 13953, Polyethylene (PE) pipes and fittings — Determination of the tensile strength and failure mode of test
pieces from a butt-fused joint

ISO 13954, Plastics pipes and fittings ! Peel decohesion test for polyethylene (PE) electrofusion assemblies of
nominal outside diameter greater than or equal to 90 mm

ISO 18553, Method for the assessment of the degree of pigment or carbon black dispersion in polyolefin pipes,
fittings and compounds

3 Terms and definitions, symbols and abbreviations

3.1 Terms and definitions

For the purposes of this document, the terms and definitions given in EN ISO 472:2001 and EN ISO 1043-1:2001
and the following apply.

3.1.1 Geometrical characteristics

3.1.1.1
nominal size
DN/OD
numerical designation of the size of a component, other than a component designated by a thread size, which is a
convenient round number, approximately equal to the manufacturing dimension in millimetres (mm) and related to

3.1.1.2
http://qstandard.org/
the outside diameter

nominal outside diameter


dn
specified outside diameter, in millimetres, assigned to a nominal size DN/OD

3.1.1.3
outside diameter at any point
de
value of the measurement of the outside diameter through its cross-section at any point of the pipe or spigot end,
rounded to the next greater 0,1 mm

3.1.1.4
mean outside diameter
dem
value of the measurement of the outer circumference of the pipe or spigot end of a fitting in any cross section
divided by π (= 3,142), rounded to the next greater 0,1 mm

3.1.1.5
minimum mean outside diameter
dem,min
minimum value of the outside diameter as specified for a given nominal size

3.1.1.6
maximum mean outside diameter
dem,max
maximum value of the outside diameter as specified for a given nominal size

7
BS EN 12201-1:2011
EN 12201-1:2011 (E)

3.1.1.7
out-of-roundness
ovality
difference between the maximum outside diameter and the minimum outside diameter in the same cross-section of
the pipe or spigot

3.1.1.8
nominal wall thickness
en
numerical designation of the wall thickness of a component, which is a convenient round number, approximately
equal to the manufacturing dimension in millimetres

NOTE For thermoplastics components conforming to the different parts of EN 12201, the value of the nominal wall
thickness, en, is identical to the specified minimum wall thickness at any point, emin.

3.1.1.9
wall thickness at any point
e
wall thickness at any point around the circumference of a component rounded to the next greater 0,1 mm

NOTE The symbol for the wall thickness of the fittings and valves body at any point is E.

3.1.1.10
minimum wall thickness at any point
emin
minimum value of the wall thickness at any point around the circumference of a component as specified

http://qstandard.org/
3.1.1.11
maximum wall thickness at any point
emax
maximum value of the wall thickness at any point around the circumference of a component as specified

3.1.1.12
mean wall thickness
em
arithmetic mean of a number of measurements of the wall thickness, regularly spaced around the circumference
and in the same cross-section of a component, including the measured minimum and the measured maximum
values of the wall thickness in that cross-section

3.1.1.13
tolerance
permitted variation of the specified value of a quantity expressed as the difference between the permissible
maximum and permitted minimum values

3.1.1.14
wall thickness tolerance
ty
permitted difference between the wall thickness at any point, e, and the nominal wall thickness, en

NOTE en ≤ e ≤ en + t y

3.1.1.15
pipe series
S
dimensionless number for pipe designation.

NOTE The relationship between the pipe series S and the standard dimension ratio SDR is given by the following equation
as specified in ISO 4065:1996 [6].

8
BS EN 12201-1:2011
EN 12201-1:2011 (E)

SDR − 1
S=
2

3.1.1.16
standard dimension ratio
SDR
numerical designation of a pipe series, which is a convenient round number, approximately equal to the dimension
ratio of the nominal outside diameter, dn, and the nominal wall thickness, en

3.1.2 Material definitions

3.1.2.1
virgin material
material in a form such as granules that has not been subjected to use or processing other than that required for its
manufacture and to which no reprocessable or recyclable materials have been added

3.1.2.2
own reprocessable material
material prepared from clean rejected unused pipes, fittings or valves, including trimmings from the production of
pipes, fittings or valves, that will be reprocessed in a manufacturer's plant after having been previously processed
by the same manufacturer in the production of components by, for example, injection-moulding or extrusion

3.1.2.3
compound
homogenous extruded mixture of base polymer (PE) and additives, i.e. anti-oxidants, pigments, carbon black, UV-
stabilisers and others, at a dosage level necessary for the processing and use of components conforming to the

http://qstandard.org/
requirements of this standard

3.1.3 Definitions related to material characteristics

3.1.3.1
lower confidence limit of the predicted hydrostatic strength
!LPL
quantity, with the dimensions of stress, which represents the 97,5 % lower confidence limit of the predicted
hydrostatic strength at a temperature θ and time t

NOTE It is expressed in megapascals.

3.1.3.2
minimum required strength
MRS
value of !LPL at 20 °C and 50 years, rounded down to the next lower value of the R10 series when !LPL is below 10
MPa, or to the next lower value of the R20 series when !LPL is 10 MPa or greater

NOTE R10 and R20 series are the Reynard number series conforming to ISO 3:1973 [3] and ISO 497:1973 [4].

3.1.3.3
design coefficient
C
coefficient with a value greater than 1, which takes into consideration service conditions as well as properties of the
components of a piping system other than those represented in the lower confidence limit

9
BS EN 12201-1:2011
EN 12201-1:2011 (E)

3.1.3.4
design stress
σs
allowable stress for a given application at 20 °C, that is derived by dividing the MRS by dividing it by the coefficient
C, i.e.:

MRS
σS =
C
NOTE It is expressed in megapascals.

3.1.3.5
melt mass-flow rate
MFR
value relating to the viscosity of the molten material at a specified temperature and load, expressed in grams per
10 min (g/10 min)

3.1.4 Definitions related to service conditions

3.1.4.1
nominal pressure
PN
numerical designation used for reference purposes related to the mechanical characteristics of the component of a
piping system

For plastic piping systems conveying water, it corresponds to the allowable operating pressure (PFA) in bar, which

http://qstandard.org/
can be sustained with water at 20 °C with a design basis of 50 years, and based on the minimum design
coefficient:

20 × MRS
PN =
C × (SDR − 1)

NOTE Research on long term performance prediction of PE water distribution systems shows a possible service life of at
least 100 years, see Bibliography [10] and [11].

3.1.4.2
allowable operating pressure
PFA
maximum hydrostatic pressure that a component is capable of withstanding continuously in service

NOTE See Annex A.

3.1.4.3
reference temperature
temperature for which the piping system is designed

NOTE It is used as the base for further calculation when designing a piping system or parts of a piping system for
operating temperatures different from the reference temperature.

3.1.5 Definitions related to joints

3.1.5.1
butt fusion joint using heated tool
joint made by heating the planed ends of pipes or spigot end fittings, the surfaces of which match by holding them
against a flat heating plate until the PE material reaches fusion temperature, removing the heating plate quickly and
pushing the two softened ends against one another

10
BS EN 12201-1:2011
EN 12201-1:2011 (E)

3.1.5.2
electrofusion joint
joint between a PE electrofusion socket or saddle fitting and a pipe or a spigot end fitting

NOTE The electrofusion fittings are heated by the Joule effect of the heating element incorporated at their jointing
surfaces, causing the material adjacent to them to melt and the pipe and fitting surfaces to fuse.

3.1.5.3
saddle fusion joint
joint made by heating the curved surface of a saddle and the outside surface of a pipe by holding them against a
heated tool until the PE material reaches fusion temperature, quickly removing the heated tool and pushing the two
softened surfaces against each other

3.1.5.4
mechanical joint
joint made by assembling a PE pipe to an other PE pipe or any other element of the piping system that generally
includes a compression part to provide for pressure integrity, leaktightness and resistance to end loads

NOTE A support sleeve inserted into the pipe bore should be used to provide a permanent support for the PE pipe to
prevent creep in the pipe wall under radial compressive forces. The metallic parts of these fittings or valves can be assembled to
metallic pipes by screw threads, compression joints, welded or brazed flanges or by other means. The fitting or valve can allow
either a dismountable or a permanently assembled joint.

3.1.5.5
fusion compatibility
ability of two similar or dissimilar polyethylene materials to be fused together to form a joint which conforms to the
performance requirements of this standard

3.2 Symbols
http://qstandard.org/
For the purposes of this document, the following symbols apply.

C design coefficient

de outside diameter (at any point)

dem mean outside diameter

dem,max maximum mean outside diameter

dem,min minimum mean outside diameter

dn nominal outside diameter

E wall thickness (at any point) of a fitting or valve body

e wall thickness (at any point) of a pipe

em mean wall thickness

emax maximum wall thickness (at any point)

emin minimum wall thickness (at any point)

en nominal wall thickness

11
BS EN 12201-1:2011
EN 12201-1:2011 (E)

σLPL lower confidence limit of the predicted hydrostatic strength at 20 °C for 50 years

σs design stress

ty wall thickness tolerance

3.3 Abbreviations

For the purposes of this document, the following abbreviations apply.

DN/OD nominal size, outside diameter related

LPL lower predicted limit

MFR melt mass-flow rate

MRS minimum required strength

OIT oxidation induction time

PE Polyethylene

PFA allowable operating pressure

PN nominal pressure

S
http://qstandard.org/
series of preferred numbers, conforming to the Renard series

pipe series as defined in ISO 4065:1996 [6]

SDR standard dimension ratio

4 Compound

4.1 Material of the components

The pipes, fittings and valves shall be made of polyethylene compound conforming to this document.

4.2 Additives

The compound shall be made by the material producer by adding to the polyethylene base polymer only those
additives, pigments or carbon black necessary for the manufacture of pipes, fittings and valves conforming to
EN 12201-2, EN 12201-3 or prEN 12201-4:2011, as applicable for their fusibility, storage and use.

All additives used shall take into account national legislation.

4.3 Colour

The colour of the compound shall be blue (PE 80 and PE 100) or black (PE 40, PE 80 and PE 100). The carbon
black used in the production of black compound shall have an average (primary) particle size of 10 nm to 25 nm.

12
BS EN 12201-1:2011
EN 12201-1:2011 (E)

NOTE In some countries, pipes made out of non-pigmented compound in conjunction with an external peelable layer are
permitted, providing the compound conforms to the requirements of this document. If this is allowed in a country, this should be
clearly stated in the national foreword.

4.4 Characteristics

4.4.1 Characteristics of the compound in the form of granules

The compound in the form of granules used for the manufacture of pipes, fittings and valves shall have
characteristics conforming to the requirements given in Table 1.

http://qstandard.org/

13
BS EN 12201-1:2011
EN 12201-1:2011 (E)

Table 1 — Characteristics of the PE compound tested in form of granules


a
Characteristics Requirements Test parameters Test method
≥ 930 kg/m
3
Compound density Test temperature 23 °C EN ISO 1183-1 and
Number of Samples Shall conform to EN ISO 1183-2
EN ISO 1183-1 and
EN ISO 1183-2
Carbon black (2 to 2,5) % by mass Shall conform to ISO 6964 ISO 6964
content (black
compound)
c
Carbon black Grade ≤ 3 Shall conform to ISO 18553 ISO 18553
dispersion (black Rating of dispersion
compound) A1,A2,A3 or B
c
Pigment dispersion Grade ≤ 3 Shall conform to ISO 18553 ISO 18553
(blue compound) Rating of dispersion
A1,A2, A3 or B
b
Water content ≤ 300 mg/kg Number of test 1 EN ISO 15512
pieces d
Volatile content ≤ 350 mg/kg Number of test 1 EN 12099
pieces d
Oxidation induction ≥ 20 min Test temperature 200 °C e ISO 11357-6
time Number of test 3 Oxygen
pieces d Test (15 +/-2) mg
atmosphere Sample
weight

http://qstandard.org/
Melt mass-flow rate (0,2 to 1,4) g/10 min Load 2,16 kg EN ISO 1133
(MFR) for PE 40 Maximum deviation Test temperature 190 °C
of ± 20 % of the Time 10 min
nominated value
f Number of test Shall conform to
d
pieces EN ISO 1133
Melt mass-flow rate (0,2 to 1,4) g/10min Load 5 kg EN ISO 1133
(MFR) for PE 80 and Maximum deviation Test temperature 190 °C
PE 100 of ± 20 % of the Time 10 min
f
nominated value Number of test Shall conform to
d
pieces EN ISO 1133
a Conformity to these requirements shall be proved by the compound manufacturer.
b Only applicable if the measured volatile content is not in conformity with its specified requirement. In case of dispute the
requirement for water content shall apply. An alternative test method ISO 760:1978 [5] may be used. The requirement applies to
the compound producer at the stage of manufacturing and to the compound user at the stage of processing (if the water content
exceeds the limit, drying is required prior to use).
c In case of dispute the test pieces for carbon black dispersion and pigment dispersion shall be prepared by the compression
method.
d The given number of test pieces indicates the quantity required to establish a value for the characteristic described in the table. The
number of test pieces required for factory production control and process control should be listed in the manufacturer’s quality plan.
For guidance see CEN/TS 12201-7 [2].
e Test may be carried out as an indirect test at 210 °C or 220 °C, providing that a clear correlation has been established. In the case
of dispute the test temperature shall be 200 °C.
f Nominated value given by the compound producer.

4.4.2 Characteristics of the compound in the form of pipe

Unless otherwise specified by the applicable test method, the test pieces shall be conditioned at (23 ± 2) °C before
testing in accordance with Table 2.

The compound in the form of pipe used for the manufacture of pipes, fittings and valves, shall have characteristics
conforming to the requirements given in Table 2.

14
BS EN 12201-1:2011
EN 12201-1:2011 (E)

Table 2 — Characteristics of the PE compound tested in the form of pipe


Characteristics Requirements a Test parameters Test method
Tensile strength for Test to failure: Pipe diameter 110 mm ISO 13953
butt-fusion b ductile: pass Pipe diameter ratio SDR 11
°
brittle: fail Test temperature 23 C
Number of test pieces c Shall conform to
ISO 13953
Slow crack growth- No failures during Test temperature 80 °C EN ISO 13479
pipe size 110 mm test period Internal test pressure
SDR11 for
PE 40 4,0 bar
PE 80 8,0 bar
PE 100 9,2 bar
Test period 500 h
Type of test Water in water
c
Number of test pieces Shall conform to
EN ISO 13479
Effect on water Shall conform to existing national regulations
quality d
Resistance to The weathered test Preconditioning EN ISO 16871
weathering pieces shall fulfil (weathering):
the requirements Cumulative radiant ≥ 3,5 GJ/m2
(Not applicable for
of the following exposure
Black compounds) c
characteristics. Number of test pieces Shall conform to
EN ISO 16871
a) Decohesion of Sample prepared in accordance with ISO 11413:2008 Jointing ISO 13954
an electrofusion
joint, 110 mm
b) Elongation at
http://qstandard.org/
condition 1: 23 °C; ≤ 33% brittle failure

Shall conform to Table 3 of EN 12201-2:2011 EN ISO 6259-1 and


break ISO 6259-3
c) Hydrostatic Shall conform to Table 3 of EN 12201-2:2011 EN ISO 1167-1 and
strength 1000 h at EN ISO 1167-2
80 °C

15
BS EN 12201-1:2011
EN 12201-1:2011 (E)

Table 2 — Characteristics of the PE compound in the form of pipe (continued)


Parameters
Characteristics Requirements Test method
Parameters Value
Resistance to rapid Arrest Pipe diameter dn 250 mm EN ISO 13477
crack propagation Pipe dimension ratio SDR 11
e,f,g Test temperature 0 °C
Test medium Air
Internal test pressure for
PE 100 10,0 bar
PE 80 8,0 bar
Number of test pieces c Shall conform to
EN ISO 13477
OR
Resistance to rapid Arrest Pipe diameter dn 500 mm EN ISO 13478
crack propagation Pipe dimension ratio SDR 11
e,f,g Test temperature 0 °C
Test medium Air
Internal test pressure for
PE 100 24,0 bar
PE 80 20,0 bar
c
Number of test pieces Shall conform to
EN ISO 13478
a Conformity to these requirements shall be proved by the compound manufacturer.
b Preparation of samples in accordance with ISO 11414:2009, normal conditions at 23 °C.
c The number of test pieces given indicate the quantity required to establish a value for the characteristic described in the table.
The number of test pieces required for factory production control and process control should be listed in the manufacturer’s

http://qstandard.org/
quality plan (for guidance see CEN/TS 12201-7 [2]).
d Test methods, parameters and requirements for all properties are under preparation. Until these European Standards are
published National Regulations shall apply (see introduction).
e To be taken into account for pipe having a wall thickness ≥ 32 mm.
f If the requirements are met, the material is qualified for the full range of pipe produced in accordance with the scope of
EN 12201 (all parts).
g If the requirements are not met for a given PE material, the critical pressure pc may be established and used to determine the
PFA for a material relative to diameter. (PFA ≤ pc, where the pc is determined in accordance with EN ISO 13478 or
PFA ≤ 3,6pc,S4 + 2,6, where pc,S4 is determined in accordance with EN ISO 13477). Attention is drawn to Note 2 in Clause 1.
Air, or a mixture of air and water (with the air content being ≥ 5 %) at a temperature of ≤ 3 °C may be used.

4.5 Fusion compatibility for PE 80 and PE 100 materials

4.5.1 The compounds conforming to Table 1 shall be fusible. This shall be demonstrated by the compound
manufacturer for each compound of his own product range by checking that the requirement for the failure mode in
a tensile test given in Table 3 is fulfilled for a butt fusion joint prepared by using the parameters as specified in
Annex A of ISO 11414:2009 at an ambient temperature of (23 ± 2) °C from pipes both manufactured from that
compound.

4.5.2 Compounds conforming to Table 1 are considered fusible to each other. If requested, the compound
manufacturer shall demonstrate this by checking that the requirement for the failure mode in a tensile test given in
Table 3 is fulfilled for a butt fusion joint prepared by using the parameters as specified in Annex A of
ISO 11414:2009 at an ambient temperature of (23 ± 2) °C from two pipes manufactured from the compounds from
his own range covered by this request.

NOTE This clause is not applicable to PE 40 materials. Pipes in these materials are joined using mechanical fittings.

16
BS EN 12201-1:2011
EN 12201-1:2011 (E)

Table 3 ! Characteristic of compound in the form of butt fusion joint


Characteristic Requirement a Test parameters Test method
Parameter Value
Determination of the Test to failure: Test temperature 23 °C ISO 13953
failure mode in a tensile Ductile – pass Number of test pieces b Shall conform to
test on buttfusion weld ISO 13953
Brittle − fail
(dn : 110 mm - SDR 11)
a The conformity to these requirements shall be proved by the compound producer.
b The numbers of test pieces given indicate the numbers required to establish a value for the characteristic described in the Table.
The numbers of test pieces required for factory production control and process control should be listed in the manufacturer’s quality
plan. For guidance see CEN/TS 12201-7 [2].

4.6 Classification and designation

Compounds shall be designated by the type of PE material. The level of minimum required strength (MRS) shall
conform to Table 4 when tested in the form of pipe.

Table 4 — Material designation and corresponding maximum design stress values


a
Minimum required strength (MRS) σs
Designation
MPa MPa
PE 100 10,0 8,0
PE 80 8,0 6,3

http://qstandard.org/
PE 40 4,0 3,2
a
The design stress σs is derived from the MRS by application of the design
coefficient C = 1,25.
NOTE A higher value for C can be used, for example if C = 1,6 this gives a
design stress of 5,0 MPa for PE 80 materials. A higher value for C can also be
obtained by choosing a higher PN class.

The compound shall be evaluated in accordance with prEN ISO 9080 from pressure tests on pipe in accordance
with EN ISO 1167-1 and EN ISO 1167-2 performed on pipe at least at three temperatures, where two of the
temperatures are fixed to 20 °C and 80 °C, and a third temperature is free between 30 °C and 70 °C, to find the
!LPL. The MRS-value shall be derived from the !LPL and the compound shall be classified by the compound
producer in accordance with EN ISO 12162.

At 80 °C, there shall be no knee detected in the regression curve at t < 5000 h.

The conformity of the designation of the compound to the classification given in Table 4 shall be demonstrated by
the compound producer.

Where fittings are manufactured from the same compound as pipes, then the material classification shall be the
same as for pipes.

For the classification of a compound intended only for the manufacture of fittings, test pieces in the form of
extruded pipe made from the compound shall be used.

5 Effect on water quality


For compounds intended to be used for components in contact with water for human consumption, attention is
drawn to the requirements of national regulations.

17
BS EN 12201-1:2011
EN 12201-1:2011 (E)

Annex A
(normative)

Pressure reduction coefficients

When a PE piping system is to be operated at a continuous constant temperature higher than 20 °C, up to 40 °C, a
pressure reduction coefficient as given in Table A.1 applies.

Table A.1 — Pressure reduction coefficients for PE 100 and PE 80 piping systems
a
Temperature Coefficient
20 °C 1,00
30 °C 0,87
40 °C 0,74
a
For other temperatures between each step, interpolation is
permitted (see also ISO 13761:1996 [7]).
NOTE Unless analysis according to prEN ISO 9080
demonstrates that less reduction is applicable, in which case higher
factors and hence higher pressures may be applied.

http://qstandard.org/
The allowable operating pressure (PFA) is derived from the following equation:

PFA = fT × fA × PN

where

fT is the coefficient in Table A.1;

fA is the derating factor (or uprating factor) related to the application (for the conveyance of water fA = 1);

PN is the nominal pressure taken as a value.

18
BS EN 12201-1:2011
EN 12201-1:2011 (E)

Bibliography

[1] EN 12201-5, Plastics piping systems for water supply, and for drainage and sewerage under pressure —
Polyethylene (PE) — Part 5: Fitness for purpose of the system

[2] CEN/TS 12201-7, Plastics piping systems for water supply — Polyethylene (PE) — Part 7: Guidance for the
assessment of conformity

[3] ISO 3:1973, Preferred numbers — Series of preferred numbers

[4] ISO 497:1973, Guide to the choice of series of preferred numbers and of series containing more rounded
values of preferred numbers

[5] ISO 760:1978, Determination of water — Karl Fischer method (General method)

[6] ISO 4065:1996, Thermoplastics pipes — Universal wall thickness table

[7] ISO 13761:1996, Plastics pipes and fittings ! Pressure reduction factors for polyethylene pipeline systems for
use at temperatures above 20 degrees C

[8] Council Directive 89/106/EEC of 21 December 1988 on the approximation of laws, regulations and
administrative provisions of the Member States relating to construction products, OJ L 40, 11.2.1989, pp. 12-
26

[9] Council Directive 98/83/EC of 3 November 1998 on the quality of water intended for human consumption, OJ

http://qstandard.org/
L 330, 5.12.1998, pp. 32-54

[10] Schulte U., Hessel J., Restlebensdauer von Kunststoffrohren nach einer Betriebszeit von 41 Jahren, 3R
international (45), Heft 9/2006

[11] Hoang E.M., Lowe D. (Exova UK) "Lifetime prediction of a blue PE100 water pipe", Polymer Degradation and
Stability, 93, Issue 8 (August 2008), pp. 1496-1503

19
BS EN 12201-1:2011 BRITISH STANDARD

National Annex (informative) Additional information on the selection


and installation of piping systems and
components in the UK
The responsible UK committee gives the following advice concerning
the selection and installation of piping systems and components
conforming to this British Standard.
a) Water supply companies and other entities deemed to be
within the scope of the Public Procurement Directives (PPD)
are obliged to use BS EN 12201-1:2011, BS EN 12201-2:2011,
BS EN 12201-3:2011, BS EN 12201-4:2011 and BS EN 12201-5:2011,
produced under European Union mandate, if they wish to
purchase PE pipe systems or components within the PPD scope.
b) CE Marking against the Construction Products Directive
does apply to pipes and fittings within the scope of
BS EN 12201-1:2011, BS EN 12201-2:2011 and BS EN 12201-3:2011
and to valves within the scope of BS EN 12201-4:2011.
c) Where there are options, care should be taken to ensure that
agreement is established between suppliers and purchasers,
e.g. in terms of colour, size, physical characteristics and Quality
Assurance.
d) For colour, it is the practice of UK water companies to use
blue PE pipes for water for human consumption, to facilitate
identification of buried water pipelines, in accordance with the
recommendations of the National Joint Utilities Group (NJUG)

http://qstandard.org/
concerning the colour coding of pipelines and other services.
Pipes for water for human consumption, installed above ground,
are black.
e) To comply with health and safety requirements for safe handling
of PE pipes supplies as coils or on drums, guidance should be
sought from the national network distributors.
f) This British Standard requires the critical pressure for rapid
crack propagation (RCP) as measured in accordance with
BS ISO 13477:2008 to be equal to or greater than the maximum
operation pressure (PFA) in BS EN 12201-1:2011, Table 2.
g) Requirements for slow crack growth (SCG) are specified in
BS EN 12201-2:2011, Table 4. The PE pipe compound is to be
tested in pipe form in accordance with BS EN ISO 13479:2009,
with a test period of 500 h. It is established practice in the UK to
use a test period of 1 000 h.

20  •  © BSI 2011


http://qstandard.org/

This page deliberately left blank


http://qstandard.org/

This page deliberately left blank


NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW

British Standards Institution (BSI)


BSI is the national body responsible for preparing British Standards and other
standards-related publications, information and services.
BSI is incorporated by Royal Charter. British Standards and other standardization
products are published by BSI Standards Limited.

About us Revisions
We bring together business, industry, government, consumers, innovators Our British Standards and other publications are updated by amendment or revision.
and others to shape their combined experience and expertise into standards We continually improve the quality of our products and services to benefit your
-based solutions. business. If you find an inaccuracy or ambiguity within a British Standard or other
The knowledge embodied in our standards has been carefully assembled in BSI publication please inform the Knowledge Centre.
a dependable format and refined through our open consultation process.
Organizations of all sizes and across all sectors choose standards to help Copyright
them achieve their goals. All the data, software and documentation set out in all British Standards and
other BSI publications are the property of and copyrighted by BSI, or some person
Information on standards or entity that owns copyright in the information used (such as the international
We can provide you with the knowledge that your organization needs standardization bodies) and has formally licensed such information to BSI for
to succeed. Find out more about British Standards by visiting our website at commercial publication and use. Except as permitted under the Copyright, Designs
bsigroup.com/standards or contacting our Customer Services team or and Patents Act 1988 no extract may be reproduced, stored in a retrieval system
Knowledge Centre. or transmitted in any form or by any means – electronic, photocopying, recording
or otherwise – without prior written permission from BSI. Details and advice can
Buying standards be obtained from the Copyright & Licensing Department.

http://qstandard.org/
You can buy and download PDF versions of BSI publications, including British
and adopted European and international standards, through our website at Useful Contacts:
bsigroup.com/shop, where hard copies can also be purchased. Customer Services
If you need international and foreign standards from other Standards Development Tel: +44 845 086 9001
Organizations, hard copies can be ordered from our Customer Services team. Email (orders): orders@bsigroup.com
Email (enquiries): cservices@bsigroup.com
Subscriptions
Subscriptions
Our range of subscription services are designed to make using standards
Tel: +44 845 086 9001
easier for you. For further information on our subscription products go to
Email: subscriptions@bsigroup.com
bsigroup.com/subscriptions.
With British Standards Online (BSOL) you’ll have instant access to over 55,000 Knowledge Centre
British and adopted European and international standards from your desktop. Tel: +44 20 8996 7004
It’s available 24/7 and is refreshed daily so you’ll always be up to date. Email: knowledgecentre@bsigroup.com
You can keep in touch with standards developments and receive substantial
Copyright & Licensing
discounts on the purchase price of standards, both in single copy and subscription
format, by becoming a BSI Subscribing Member. Tel: +44 20 8996 7070
Email: copyright@bsigroup.com
PLUS is an updating service exclusive to BSI Subscribing Members. You will
automatically receive the latest hard copy of your standards when they’re
revised or replaced.
To find out more about becoming a BSI Subscribing Member and the benefits
of membership, please visit bsigroup.com/shop.
With a Multi-User Network Licence (MUNL) you are able to host standards
publications on your intranet. Licences can cover as few or as many users as you
wish. With updates supplied as soon as they’re available, you can be sure your
documentation is current. For further information, email bsmusales@bsigroup.com.

BSI Group Headquarters


389 Chiswick High Road London W4 4AL UK

Das könnte Ihnen auch gefallen