Sie sind auf Seite 1von 2

Design Parameter

BEAM

Beam A

The concrete cover designed for this beam is 40mm and the exposure class is XC3/4 which is the
grade for the concrete is C35, maximum water/cement ratio is 0.60 and the maximum cement
content is 280. Then the value for Fck and Fyk that have been design are 35kN/mm2 and 500
respectively. Main bar size that we used in this design is 20 mm of the diameter and the type of
the steel is H20. To link all the reinforcement in beam, the size of link which is 10mm of
diameter and the type of the steel is H10 has been design. The minimum percent of
reinforcement is 0.17. Based on the factors that affect the durability of this structure we
considered that the class of designation is XC3 and XC4 which is moderated humidity and cyclic
wet and dry. With the breadth of 300mm, 30mm of axis distance from soffit and 30mm axis
distance from side of the beam, the standard that have been chosen for fire resistance is R60.

Beam B

The concrete cover designed for this beam is 40mm and the exposure class is XC3/4 which is
the grade for the concrete is C35,maximum water/cement ratio is 0.60 and the maximum cement
content is 280. Then the value for Fck and Fyk that have been design are 35kN/mm2 and 500
respectively. Main bar size that we used in this design is 16 mm of the diameter and the type of
the steel is H16. To link all the reinforcement in beam, the size of link which is 10mm of
diameter and the type of the steel is H10 has been design. The minimum percent of
reinforcement is 0.17. Based on the factors that affect the durability of this structure we
considered that the class of designation is XC3 and XC4 which is moderated humidity and cyclic
wet and dry. With the breadth of 300mm, 30mm of axis distance from soffit and 30mm axis
distance from side of the beam, the standard that have been chosen for fire resistance is R60.
SLAB

The parameter of slab design has been set up with 250mm thick and 12m of span which is 6m for
short span and 6m for long span. Then the design of concrete cover for the slab is 40mm and the
exposure class is XC3/4 which is the grade for the concrete is C35, maximum water/cement ratio
is 0.60 and the maximum cement content is 280. Based on the factors that affect the durability of
this structure we considered that the class of designation is XC3 and XC4 which is moderated
humidity and cyclic wet and dry. In this slab the imposed load and weight of screed has been
designed which is 7.5kN/m2 and 1.5kN/m2. The reinforcement for x-direction in slab used is
H12 at 175mm centres and H16 at 300mm centres for y-direction. This slab was designed to
carries the following load which is 7.5kN/m2 of imposed load, 1.5kN/m2 weight of screed and
0.46kN/m2 of 20mm water proof asphalt. Considered that this is simply supported slab, the
thickness of 250mm will be considered by design of fire resistant of R60.

COLUMN

In this project we decided that the height of the structure is 4m, so the height of column that has
been design is 4m and the shape of column is square which is 500mm x 300mm. For grade of
concrete used for that column 1 and column 2 structures is C35 and the concrete cover for the
column is 40mm. Then the deep beam for the column is 550mm. Steel that has been design for
column 1are using 4H32 and 6H12 type of steel and for column 2 is 4H32. Type of link that used
for both column is H10. As the cross-section dimension of the column is 500mm x 600mm, the
resistance to fire designed for this structure was R240.