Sie sind auf Seite 1von 1

ELECTRICAL GENERAL NOTES

ALL ELECTRICAL WORKS AND INSTALLATIONS HEREIN SHALL BE EXECUTED IN ACCORDANCE WITH THE LATEST
APPROVED EDITION OF THE PHILLIPINE ELECTRICAL CODE (PEC), RULES AND REGULATIONS
OF THE LOACAL AND NATIONAL AUTHORITIES CONCERNED IN THE IMPLEMENTATION OF ELECTRICAL
R REF.
LAWS AND ORDINACES AND THE LOCAL POWER UTILITY AND TELEPHONE COMPANIES.
S
S
WORMASHIP SHALL BE EQUAL TO THE BEST STANDARD PRACTICE RECOGNIZED AND ADOPTED FOR THIS
1 2 3 4 TRADE. ONLY EXPERIENCED MEN UNDER THE DIRECT SUPERVISION OF A DULY LICENSED
ELECTRICAL ENGINEER SHALL EXECUTE ALL ELECTRICAL WORKS HEREIN INCLUDE. WORKS HERIN INCLUDE. WOKS SHALL
BE NEATLY PLACED, SECURELY FASTENED AND PROPERLY FINISHD.

ALL MATERIALS USED SHALL BE NEW AND APPROVED FOR BOTH PURPOSE AND LOACTION INTENDED.

ALL WIRES TYPE TW / THW SHAL BE INSULATED FOR 600 VOLTS AND SHALL BE INSIDE RIGID
uPVC PIPES. ELECTRICAL TRADE SIZES WERE USED (A MINIMUM OF 15mm DIAMETER FOR
CONDUITS AND 3.5mm sq FOR CIRCUITS RUNS). ALL CIRCUIT BREAKERS SHALL BE BOLT-ON

NO BRANCH CIRCUIT SHALL BE HAVE A LOAD OF MORE THAN 80% OF ITS RATING.
ELECTRICAL SERVICE REQUIREMENTS SHALL BE 220 VOLTS, 1-PHASE, 60 HERTZ.
YPE AND INSIDE FACTORY STANDARD ENCLOSURES.

LEGEND:
TUBULAR WITH COMPACT FLUORESCENT BULB
REF. REFRIGERATOR OUTLET
R THREE-PRONGS COOKING RANGE OUTLET
2 CIRCUIT HOMERUN FOR APPLIANCE OUTLETS
LIGHTING LAY-OUT POWER LAY-OUT
CIRCUIT HOMERUN FOR LIGHTING
FLOOR PLAN FLOOR PLAN 1

S FLUSH TYPE WALL SWITCH


SCALE 1:50M SCALE 1:50M LPP LIGHTING & POWER PANELBOARD

TO POWER SOURCE
220V, 2P, 60 HERTZ

M PB1 SCHEDULE OF LOADS


1 - # 8.0mm² TW QUANTITY POWER SWITCH CIRCUIT
1 - # 2.0 mm² THHN PB CKT. NO.
DESCRIPTION LIGHT CO OTHERS
(WATTS) CURRENT
S1 S2 S3 3WAY
VOLTS
BREAKER PHASE CONDUIT SIZE WIRE SIZE

60AT, 2P 1 20-Watts Fluorescent Bulb 15 300 1.36 2 220 10 20mm Ø PVC PIPE 2 - 3.5mm² THHN WIRE
220 V
2 Duplex Convenience Outlet 4 720 3.27 220 10 25mm Ø PVC PIPE 2 - 5.5mm² THHN WIRE
10AT, 2P 10AT, 2P Range 1 220 40 25mm Ø PVC PIPE 2 - 5.5mm² THHN WIRE
3 8,000 36.36
1 2 Refrigerator Outlet 2 - 5.5mm² THHN WIRE
4 1 500 2.27 220 10 25mm Ø PVC PIPE
40AT, 2P 10AT, 2P
TOTAL 9,520 43.27 220 60 AT 2P 32mm Ø PVC PIPE
3 4
Ic = [ ( 0.25 x 12.0) + (43.27)] (0.80) Ip = [ ( 2.00 x 12.0) + (43.27)] (0.80)
= 37.016 Amperes = 53.816 Amperes
use 2- 8.0mm sq. THW wire + 1 - 2.0mm sq. THW wire 32mm Ø PVC Pipe use 60AT 2P 100AF 10KAIC 220V bolt-on type MCCB

SINGLE LINE DIAGRAM


DESIGNED BY: THIS DRAWING IS ISSUED FOR:
FROM THE OFFICE OF: PRC. NO. : 1518 SEAL PROJECT TITLE PROJECT OWNER: SHEET CONTENTS: AS BUILT ESTIMATE SHEET NO.

DRAFTED BY: BIDDING FABRICATION


VALIDITY : 04/24/2021
INTERIOR RENOVATION OF BUILDING PERMIT OWNER'S APPROVAL

PTR. NO. : 21399539


GERALDINE TABILINO
DATE:
CONSTRUCTION PRESENTATION E
OFELIO T. MIPARANUM ONECENTRAL MALL
DATE : 03/19/19 IMPORTANT : MEASUREMENTS ARE VERIFIED ON SITE AND ALL DISCREPANCIES
SHOULD BE REPORTED TO THE ARCHITECT. 1 1