COOLING TOWERS
DO'S
1 Check if Incomer & out going MCB is in ON position
2 Incoming Voltage shall be min 415V in all three phases
3 Check whether inlet & outlet valves are open
4 Inlet pressure of water shall be at least 1.0 Kg/ sq.cm
5 Check Sumps should be clean
6 Check no Major water leaks in the pipe line
7 Then Switch ON the Pump and Fan in Auto/ Manual mode
8 Check for abnormal noise & vibration of the Pump
9 Continue to take log readings if found O.K
10 Ensure perfect alignment of Fan blades
11 Bearings have to Grease arrange for the lubrication every 6 months
12 Check CT Fan is Heating or not
DON'TS
DO'S
DON'TS
1 Improper voltage don’t switch on the unit
2 Motor is taking more then design amps don’t switch on the unit
3 Switch off the unit incase of fire
4 If dampers(Fire/vcd) are closed don't switch the unit
5 If filters are blocked don’t switch on the unit
6 the unit should never be operated with out the filters.
7 If belts are loose are not satisfactory don’t switch on the unit
Do not pry or V-belts into the pulley grooves, if done so, belts get damaged internally
8
as a result of which belt life is affected
9 A change in ride out indicates uneven belt wear. Change belt with new set
HVAC PLANT DO'S AND DON'TS
PUMPS
DO'S
DON'TS
DO'S
DON'TS
1 Improper voltage don’t switch on the unit
2 Motor is taking more then design amps don’t switch on the unit
3 Switch off the unit incase of fire
4 If dampers(Fire/vcd) are closed don't switch the unit
5 If filters are blocked don’t switch on the unit
6 The unit should never be operated with out the filters.
7 If belts are loose are not satisfactory don’t switch on the unit
Do not pry or V-belts into the pulley grooves, if done so, belts get damaged internally
8
as a result of which belt life is affected
9 A change in ride out indicates uneven belt wear. Change belt with new set
HVAC PLANT DO'S AND DON'TS
AXIAL FANS
DO'S
DON'TS
Do not spin Ventilator Impeller faster than the maximum cataloged
Ventilator rpm. Adjustments to Ventilator speed with Variable Frequency
1 Drives (VFD) may affect motor load. If the Ventilator RPM is changed, the
motor current should be checked to make sure it is not exceeding the motor
nameplate amps.
2 Do not spin Ventilator in counter direction than prescribed on ventilator.
Do not allow the power cable to kink or come in contact with oil, grease, hot
3 surfaces or chemicals. Replace cord immediately if damaged.
4 Do not let the fan air getting blocked by any other services.
5 Always check the rotation of fan after starting the fan.
HVAC PLANT DO'S AND DON'T
1
2
3
4
5
6
7
8
9
10
1
2
3
6
HVAC PLANT DO'S AND DON'TS
DO'S
DON'TS
Check if Incomer & out going MCB is in ON position from the main
1 panel.
2 Incoming Voltage shall be min 415V in all three phases
3 Check water flows and interlocks
4 Check operational set points and current performance of the chiller
5 Check operation of all safety devices installed for the chiller
6 Check the unit alarm report when the unit does not work
6 Record operating pressures, amperages and voltage
7 Change the oil as required based upon results of the oil analysis
8 Check the correct operation of the heaters
9 Always check for the lubrication of motors/dampers/bearings (where applicable)
10 Check operation of machines/compare conditions of operation
against original commissioning data
11 Fill the maintenance visit log sheet and review with the operator
12 Make sure the fins are regularly inspected to check the degree of fouling.
DON'TS