Sie sind auf Seite 1von 157

A B C D E F G H J K L M N P Q

PLOT 02 - 100% CONSTRUCTION DOCUMENTS FOR TENDER


24.08.2017
STRUCTURE
11

10

Client:

MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


www.ae-7.com
1 Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
Drawing Number

14011603-02-00-SG0000
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

DRAWING LIST PLOT 02 - STRUCTURAL DRAWING LIST PLOT 02 - STRUCTURAL


SHEET NUMBER SHEET NAME SCALE REV. SHEET NUMBER SHEET NAME SCALE REV.
14011603-02-00-SG0000 COVER SHEET - STRUCTURAL N.T.S 0 BUILDING 03
14011603-02-00-SG0001 DRAWING LIST - STRUCTURAL N.T.S 0 14011603-02-03-SC1000 GROUND LEVEL - COLUMNS & WALLS SETTING OUT PLAN - OVERALL 1:200 0
14011603-02-00-SG0002 STRUCTURAL GENERAL NOTES - 01 N.T.S 0 14011603-02-03-SC1000a GROUND LEVEL - COLUMNS & WALLS SETTING OUT PLAN - PART A 1:150 0 N
10 14011603-02-00-SG0003 STRUCTURAL GENERAL NOTES - 02 N.T.S 0 14011603-02-03-SC1000b GROUND LEVEL - COLUMNS & WALLS SETTING OUT PLAN - PART B 1:150 0 KEY PLAN
14011603-02-00-SG0004 STRUCTURAL GENERAL NOTES - 03 N.T.S 0 14011603-02-03-SC1001 LEVEL 01 - COLUMNS & WALLS SETTING OUT PLAN - OVERALL 1:200 0
14011603-02-00-SG0005 STRUCTURAL GENERAL NOTES - 04 N.T.S 0 14011603-02-03-SC1001a LEVEL 01 - COLUMNS & WALLS SETTING OUT PLAN - PART A 1:150 0
14011603-02-00-SG0006 STRUCTURAL GENERAL DETAILS - 01 N.T.S 0 14011603-02-03-SC1001b LEVEL 01 - COLUMNS & WALLS SETTING OUT PLAN - PART B 1:150 0
14011603-02-00-SG0007 STRUCTURAL GENERAL DETAILS - 02 N.T.S 0 14011603-02-03-SC1002 LEVEL 02 - COLUMNS & WALLS SETTING OUT PLAN - OVERALL 1:200 0
14011603-02-00-SG0008 STRUCTURAL GENERAL DETAILS - 03 N.T.S 0 14011603-02-03-SC1002a LEVEL 02 - COLUMNS & WALLS SETTING OUT PLAN - PART A 1:150 0
14011603-02-00-SG0009 STRUCTURAL GENERAL DETAILS - 04 N.T.S 0 14011603-02-03-SC1002b LEVEL 02 - COLUMNS & WALLS SETTING OUT PLAN - PART B 1:150 0
14011603-02-00-SG0010 STRUCTURAL GENERAL DETAILS - 05 N.T.S 0 14011603-02-03-SC1003 LEVEL 03 - COLUMNS & WALLS SETTING OUT PLAN - OVERALL 1:200 0
14011603-02-00-SG0011 STRUCTURAL GENERAL DETAILS - 06 N.T.S 0 14011603-02-03-SC1003a LEVEL 03 - COLUMNS & WALLS SETTING OUT PLAN - PART A 1:150 0
14011603-02-00-SG0012 STRUCTURAL GENERAL DETAILS - 07 N.T.S 0 14011603-02-03-SC1003b LEVEL 03 - COLUMNS & WALLS SETTING OUT PLAN - PART B 1:150 0
14011603-02-00-SG0013 STRUCTURAL GENERAL DETAILS - 08 N.T.S 0 14011603-02-03-SC1004 LEVEL 04 - COLUMNS & WALLS SETTING OUT PLAN - OVERALL 1:200 0
9 14011603-02-00-SG0014 STRUCTURAL GENERAL DETAILS - 09 N.T.S 0 14011603-02-03-SC1004a LEVEL 04 - COLUMNS & WALLS SETTING OUT PLAN - PART A 1:150 0
14011603-02-00-SG0015 STRUCTURAL GENERAL DETAILS - 10 N.T.S 0 14011603-02-03-SC1004b LEVEL 04 - COLUMNS & WALLS SETTING OUT PLAN - PART B 1:150 0
14011603-02-00-SG0016 STRUCTURAL GENERAL DETAILS - 11 N.T.S 0
14011603-02-00-SG0017 STRUCTURAL GENERAL DETAILS - 12 N.T.S 0 14011603-02-03-SF1001 LEVEL 01 - FRAMING PLAN - OVERALL 1:200 0
14011603-02-00-SG0018 STRUCTURAL GENERAL DETAILS - 13 N.T.S 0 14011603-02-03-SF1001a LEVEL 01 - FRAMING PLAN - PART A 1:150 0
General Notes:
14011603-02-00-SG0019 STRUCTURAL GENERAL DETAILS - 14 N.T.S 0 14011603-02-03-SF1001b LEVEL 01 - FRAMING PLAN - PART B 1:150 0 1. DO NOT SCALE FROM THIS DRAWING.
14011603-02-00-SG0020 STRUCTURAL GENERAL DETAILS - 15 N.T.S 0 14011603-02-03-SF1002 LEVEL 02 - FRAMING PLAN - OVERALL 1:200 0
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
14011603-02-00-SG0021 STRUCTURAL GENERAL DETAILS - 16 N.T.S 0 14011603-02-03-SF1002a LEVEL 02 - FRAMING PLAN - PART A 1:150 0 NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.
14011603-02-00-SG0022 STRUCTURAL GENERAL DETAILS - 17 N.T.S 0 14011603-02-03-SF1002b LEVEL 02 - FRAMING PLAN - PART B 1:150 0
14011603-02-00-SG0023 STRUCTURAL GENERAL DETAILS - 18 N.T.S 0 14011603-02-03-SF1003 LEVEL 03 - FRAMING PLAN - OVERALL 1:200 0 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 14011603-02-00-SG0024 STRUCTURAL GENERAL DETAILS - 19 N.T.S 0 14011603-02-03-SF1003a LEVEL 03 - FRAMING PLAN - PART A 1:150 0 AT SITE.
14011603-02-00-SG0025 STRUCTURAL GENERAL DETAILS - 20 N.T.S 0 14011603-02-03-SF1003b LEVEL 03 - FRAMING PLAN - PART B 1:150 0
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
14011603-02-00-SG0026 STRUCTURAL GENERAL DETAILS - 21 N.T.S 0 14011603-02-03-SF1004 LEVEL 04 - FRAMING PLAN - OVERALL 1:200 0 ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
14011603-02-00-SG0027 STRUCTURAL GENERAL DETAILS - 22 N.T.S 0 14011603-02-03-SF1004a LEVEL 04 - FRAMING PLAN - PART A 1:150 0 AND RELEVANT SECTIONS OF THE SPECIFICATION.
14011603-02-03-SF1004b LEVEL 04 - FRAMING PLAN - PART B 1:150 0
14011603-02-00-SE0100 EXCAVATION PLAN 1:350 0 14011603-02-03-SF1005 ROOF LEVEL - FRAMING PLAN - OVERALL 1:200 0
14011603-02-00-SP0999 BASEMENT 01 LEVEL - FRAMING & PILE CAPS PLAN - OVERALL 1:350 0 14011603-02-03-SF1005a ROOF LEVEL - FRAMING PLAN - PART A 1:150 0
14011603-02-00-SP0999a BASEMENT 01 LEVEL - FRAMING & PILE CAPS PLAN - PART A 1:150 0 14011603-02-03-SF1005b ROOF LEVEL - FRAMING PLAN - PART B 1:150 0
14011603-02-00-SP0999b BASEMENT 01 LEVEL - FRAMING & PILE CAPS PLAN - PART B 1:150 0
14011603-02-00-SP0999c BASEMENT 01 LEVEL - FRAMING & PILE CAPS PLAN - PART C 1:150 0 14011603-02-03-SL1001 LEVEL 01 - LOADING PLAN 1:200 0
14011603-02-03-SL1002 LEVEL 02 - LOADING PLAN 1:200 0
7 14011603-02-00-SC0999 BASEMENT 01 LEVEL - COLUMNS & WALLS SETTING OUT PLAN - OVERALL 1:350 0 14011603-02-03-SL1003 LEVEL 03 - LOADING PLAN 1:200 0
14011603-02-00-SC0999a BASEMENT 01 LEVEL - COLUMNS & WALLS SETTING OUT PLAN - PART A 1:150 0 14011603-02-03-SL1004 LEVEL 04 - LOADING PLAN 1:200 0
14011603-02-00-SC0999b BASEMENT 01 LEVEL - COLUMNS & WALLS SETTING OUT PLAN - PART B 1:150 0 14011603-02-03-SL1005 ROOF LEVEL - LOADING PLAN 1:200 0
14011603-02-00-SC0999c BASEMENT 01 LEVEL - COLUMNS & WALLS SETTING OUT PLAN - PART C 1:150 0
14011603-02-03-S5201 CORE WALL DETAILS - 01 1:50 0
14011603-02-00-SF1000 GROUND LEVEL - FRAMING PLAN - OVERALL 1:350 0 14011603-02-03-S5202 CORE WALL DETAILS - 02 1:50 0
14011603-02-00-SF1000a GROUND LEVEL - FRAMING PLAN - PART A 1:150 0 14011603-02-03-S5203 CORE WALL DETAILS - 03 1:50 0
14011603-02-00-SF1000b GROUND LEVEL - FRAMING PLAN - PART B 1:150 0 14011603-02-03-S5204 CORE WALL DETAILS - 04 1:50 0
14011603-02-00-SF1000c GROUND LEVEL - FRAMING PLAN - PART C 1:150 0 14011603-02-03-S5205 CORE WALL DETAILS - 05 1:50 0
14011603-02-03-S5206 CORE WALL DETAILS - 06 1:50 0
6 14011603-02-00-SRB0999 BASEMENT 01 LEVEL - BOTTOM REINFRORCEMENT PLAN - OVERALL 1:350 0
14011603-02-00-SRB0999a BASEMENT 01 LEVEL - BOTTOM REINFRORCEMENT PLAN - PART A 1:150 0 14011603-02-03-S6101 COLUMN & WALL SCHEDULES - 01 1:25 0
14011603-02-00-SRB0999b BASEMENT 01 LEVEL - BOTTOM REINFRORCEMENT PLAN - PART B 1:150 0 14011603-02-03-S6102 COLUMN & WALL SCHEDULES - 02 1:25 0
14011603-02-00-SRB0999c BASEMENT 01 LEVEL - BOTTOM REINFRORCEMENT PLAN - PART C 1:150 0 14011603-02-03-S6103 COLUMN & WALL SCHEDULES - 03 1:25 0
14011603-02-00-SRT0999 BASEMENT 01 LEVEL - TOP REINFRORCEMENT PLAN - OVERALL 1:350 0 14011603-02-03-S6104 COLUMN & WALL SCHEDULES - 04 1:25 0 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
14011603-02-00-SRT0999a BASEMENT 01 LEVEL - TOP REINFRORCEMENT PLAN - PART A 1:150 0 14011603-02-03-S6105 COLUMN & WALL SCHEDULES - 05 1:25 0 AUTHORITY APPROVAL 0 08.08.2017 NS
14011603-02-00-SRT0999b BASEMENT 01 LEVEL - TOP REINFRORCEMENT PLAN - PART B 1:150 0 14011603-02-03-S6106 COLUMN & WALL SCHEDULES - 06 1:25 0 Purpose of Issue Rev. Date Appoved
14011603-02-00-SRT0999c BASEMENT 01 LEVEL - TOP REINFRORCEMENT PLAN - PART C 1:150 0 14011603-02-03-S6107 COLUMN & WALL SCHEDULES - 07 1:25 0 Client:
14011603-02-03-S6201 BEAMS SCHEDULE - 01 N.T.S 0
14011603-02-00-SR1000 GROUND LEVEL - REINFORCEMENT PLAN - OVERALL 1:350 0 14011603-02-03-S6202 BEAMS SCHEDULE - 02 N.T.S 0
14011603-02-00-SR1000a GROUND LEVEL - REINFORCEMENT PLAN - PART A 1:150 0 BUILDING 04
5 14011603-02-00-SR1000b GROUND LEVEL - REINFORCEMENT PLAN - PART B 1:150 0 14011603-02-04-SC1000 GROUND LEVEL - COLUMNS & WALLS SETTING OUT PLAN 1:150 0
MEYDAN L.L.C
14011603-02-00-SR1000c GROUND LEVEL - REINFORCEMENT PLAN - PART C 1:150 0 14011603-02-04-SC1001 LEVEL 01 - COLUMNS & WALLS SETTING OUT PLAN 1:150 0 P.O. Box 9305, Dubai , UAE.
14011603-02-04-SC1002 LEVEL 02 - COLUMNS & WALLS SETTING OUT PLAN 1:150 0 T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com
14011603-02-00-S5101 FOUNDATION DETAILS - 01 1:50 0 14011603-02-04-SC1003 LEVEL 03 - COLUMNS & WALLS SETTING OUT PLAN 1:150 0
Principal Consultant:
14011603-02-00-S5102 FOUNDATION DETAILS - 02 1:50 0 14011603-02-04-SC1004 LEVEL 04 - COLUMNS & WALLS SETTING OUT PLAN 1:150 0
14011603-02-00-S5103 FOUNDATION DETAILS - 03 1:50 0
14011603-02-00-S5104 FOUNDATION DETAILS - 04 1:25 0 14011603-02-04-SF1001 LEVEL 01 - FRAMING PLAN 1:150 0
14011603-02-00-S5105 FOUNDATION DETAILS - 05 1:25 0 14011603-02-04-SF1002 LEVEL 02 - FRAMING PLAN 1:150 0 abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
14011603-02-00-S5106 FOUNDATION DETAILS - 06 1:25 0 14011603-02-04-SF1003 LEVEL 03 - FRAMING PLAN 1:150 0 www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
14011603-02-00-S5107 FOUNDATION DETAILS - 07 1:25 0 14011603-02-04-SF1004 LEVEL 04 - FRAMING PLAN 1:150 0 PO Box 54115 Dubai, UAE
14011603-02-00-S5108 FOUNDATION DETAILS - 08 1:25 0 14011603-02-04-SF1005 ROOF LEVEL - FRAMING PLAN 1:150 0 P: +971 4 3997758 F: +971 4 3997759
4
14011603-02-00-S5109 FOUNDATION DETAILS - 09 1:25 0 Sub-Consultant:
14011603-02-00-S5301 SLAB DETAILS - 01 1:25 0 14011603-02-04-SL1001 LEVEL 01 - LOADING PLAN 1:150 0
14011603-02-00-S5302 SLAB DETAILS - 02 1:25 0 14011603-02-04-SL1002 LEVEL 02 - LOADING PLAN 1:150 0
14011603-02-00-S5303 SLAB DETAILS - 03 1:25 0 14011603-02-04-SL1003 LEVEL 03 - LOADING PLAN 1:150 0
14011603-02-00-S5304 SLAB DETAILS - 04 1:25 0 14011603-02-04-SL1004 LEVEL 04 - LOADING PLAN 1:150 0
14011603-02-00-S5305 SLAB DETAILS - 05 1:25 0 14011603-02-04-SL1005 ROOF LEVEL - LOADING PLAN 1:150 0
14011603-02-00-S5306 SLAB DETAILS - 06 AS INDICATED 0
14011603-02-00-S5501 STAIRS DETAILS - 01 1:50 0 14011603-02-04-S5201 CORE WALL DETAILS - 01 1:50 0 Project Name:
14011603-02-00-S5502 STAIRS DETAILS - 02 1:50 0 14011603-02-04-S5202 CORE WALL DETAILS - 02 1:50 0

3
14011603-02-00-S5503 STAIRS DETAILS - 03 1:50 0 14011603-02-04-S5203 CORE WALL DETAILS - 03 1:50 0 DUBAI WATER CANAL
14011603-02-00-S5504 STAIRS DETAILS - 04 1:50 0
14011603-02-00-S5505 STAIRS DETAILS - 05 AS INDICATED 0 14011603-02-04-S6101 COLUMN & WALL SCHEDULES - 01 1:25 0
SAFA A
14011603-02-00-S5506 STAIRS DETAILS - 06 1:50 0 14011603-02-04-S6102 COLUMN & WALL SCHEDULES - 02 1:25 0 DUBAI-UAE
14011603-02-00-S5507 STAIRS DETAILS - 07 1:25 0 14011603-02-04-S6103 COLUMN & WALL SCHEDULES - 03 1:25 0
14011603-02-00-S5601 RAMP DETAILS - 01 1:100 0 14011603-02-04-S6104 COLUMN & WALL SCHEDULES - 04 1:25 0
Project Description:
14011603-02-00-S5602 RAMP DETAILS - 02 1:50 0 14011603-02-04-S6105 COLUMN & WALL SCHEDULES - 05 1:25 0
14011603-02-00-S5901 WATER TANK DETAILS 1:50 0 14011603-02-04-S6106 COLUMN & WALL SCHEDULES - 06 1:25 0 MIXED USE DEVELOPMENT
14011603-02-04-S6107 COLUMN & WALL SCHEDULES - 07 1:25 0
14011603-02-00-S6001 PILE CAP SCHEDULE N.T.S 0 14011603-02-04-S6201 BEAMS SCHEDULE N.T.S 0
(RETAIL & RESIDENTIAL)
14011603-02-00-S6301 SLAB REINFORCEMENT & SCHEDULES - 01 N.T.S 0 PLOT 02 / 3435336
2 14011603-02-00-S6302 SLAB REINFORCEMENT & SCHEDULES - 02 N.T.S 0 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
Drawing Title:

DRAWING LIST - STRUCTURAL

Scale Drawn Checked Approved Size


AA MA NS
1 N.T.S A1
26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-02-00-SG0001 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11
2-11. CONCRETE GRADES SHALL BE AS FOLLOWS, UNLESS NOTED 3. NOTES OF DESIGN LOAD CRITERIA
1. GENERAL NOTES OTHERWISE:-

1-1. ALL STRUCTURAL DRAWINGS TO BE READ IN CONJUNCTION WITH RELEVANT ARCHITECT'S 3-1. GRAVITY LOADS
CONCRETE GRADE GGBS MODULUS OF
DRAWINGS, SERVICES ENGINEER'S DRAWINGS, SPECIFICATIONS AND PRELIMINARIES. ELEMENTS CEMENT SUPERIMPOSED DEAD LOAD (SDL) (kPa)
CUBIC / CYLINDER (%) ELACTICITY LIVE LOAD
(N/mm2) TYPE (Ec) Mpa
FLOOR USAGE
1-2. FOR SETTING OUT REFER TO ARCHITECTURAL DRAWINGS. FINISHES SERVICES & PARTITIONS & (LL) (kPa)
1-3. ALL DIMENSIONS ARE IN MILLIMETRES UNLESS OTHERWISE STATED.
CEILING BRICK WALLS
PILE C50 / 40 OPC 55% 29725
INACCESSIBLE LIGHT ROOF 2.50 0.50 ---- 1.00
1-4. DO NOT SCALE FROM DRAWINGS. ONLY FIGURED DIMENSIONS ON THE DRAWINGS ARE TO FOUNDATIONS / PILE CAPS C60 / 50 OPC 55% 37721
BE USED. MEMBERS ARE PLACED SYMMETRICALLY ABOUT GRIDLINES UNLESS NOTED 4.00 ---- 2.00 N
10 ACCESSIBLE ROOF 0.50 KEY PLAN
OTHERWISE. COLUMNS / SHEAR WALLS C60 / 50 OPC ---- 37721
MEP ROOF 4.50 0.50 ---- 5.00
1-5. FOR DIMENSIONS AND SETTING OUT OF NON-STRUCTURAL COLUMNS/WALLS, PARAPETS BASEMENT RETAINING WALL/ STAIRS /
C45 / 36 OPC 55% 28200
AND CLADDING WALL DETAILS, REFER TO ARCHITECTURAL / CIVIL DRAWINGS. RAMPS/UP-STANDS CHILLER ROOF 9.50 0.50 ---- 7.50
1-6. ALL LEVELS ARE MENTIONED IN (m) AND SHALL BE READ WTIH THE THE ARCHITECTURAL WATER TANK C60 / 50 OPC 55% 37721 RESIDENTIAL 1.70 5.60 2.00
0.50
DRAWINGS. BEAMS / SLABS C60 / 50 OPC ---- 37721 LOBBY ----
0.50 5.00
TRANSFER BEAMS / SLABS C60 / 50 OPC ---- 2.50
1-7. ALL STRUCTURAL WORKS SHALL COMPLY WITH THE SPECIFICATIONS, SPECIFIED 37721
STANDARD CODES AND OTHER RELEVANT UAE STANDARDS. WHERE STRUCTURAL SWIMMING POOL C60 / 50 OPC 55% 37721 CAR PARK 1.00 0.50 ---- 3.50
REQUIREMENTS ARE COVERED BY MORE THAN ONE DOCUMENT, THE STRONGEST BLINDING C25 / 20 OPC ---- ----
9 REQUIREMENTS SHALL APPLY. 4.50 0.50 ----
GYM 5.00

1-8. UNLESS OTHERWISE STATED ON THE DRAWINGS, SIZE OF STRUCTURAL MEMBERS ARE RETAILS 11.50 0.50 ---- 5.00
SHOWN AS FOLLOWS : e.g. (200) - 200mm THICK WALL UNDER, (150) - 150mm THICK SLAB.
LANDSCAPE AREA VARIOUS General Notes:
1-9. THE SUPERIMPOSED LIVE LOADS AND SUPERIMPOSED DEAD LOADS SPECIFIED AS 1. DO NOT SCALE FROM THIS DRAWING.
FACADE VARIOUS
CHARACTERISTIC LOADS. TEMPORARY LOADS DURING CONSTRUCTION MUST NOT EXCEED
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
THE SPECIFIED CHARACTERISTIC LOADS UNLESS OTHERWISE STATED ON THE DRAWING. 2-12. COVER TO ALL REINFORCEMENT TO BE AS FOLLOWS, NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
UNLESS NOTED OTHERWISE : BY THE ENGINEER.

1-10. ALL STRUCTURES SUPPORTED BY HANGER MUST REMAIN PROPPED UNTIL THE 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
8 SUPPORTING STRUCTURES ARE CAST AND HAVE GAINED THE REQUIRED STRENGTH. CONDITION COVER (mm) SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
AT SITE.

CONCRETE CAST IN WATER 100mm 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
1-11. FOR DETAILS OF ALL NON-STRUCTURAL CONCRETE ELEMENTS INCLUDING CONCRETE
CONCRETE CAST AGAINST & PERMANENTLY 75mm
AND RELEVANT SECTIONS OF THE SPECIFICATION.
SURROUNDINGS TO PIPES/DUCTS, KERBS, DRAINAGE CHANNELS, PLINTHS FOR
EXPOSED TO EARTH 3-2. WIND LOADS
MECHANICAL PLANT AND EQUIPMENT, REFER TO THE RELEVANT ARCHITECTURAL AND
SERVICES ENGINEER. PILES 75mm 3-2-1. WIND LOADS BASED ON ASCE 7-05, WITH THE FOLLOWING DATA;
FOUNDATIONS / PILE CAPS 75mm EARTH FACES, AND 50mm OTHER FACES - DESIGN WIND SPEED 45 m/s
1-12. ANY INFORMATION CONCERNING THE NATURE OF THE GROUND FROM THE AVAILABLE
SITE INVESTIGATION REPORTS IS GIVEN IN GOOD FAITH AND NO GUARANTEE IS GIVEN OF COLUMNS & SHEAR WALLS 50mm EXTERNAL, AND 40mm INTERNAL - EXPOSURE CATEGORY C
ITS ACCURACY OR APPLICABILITY THROUGHOUT THE SITE.
7 - IMPORTANCE FACTOR 1.00 (TABLE 6-1)
BASEMENT RETAINING WALLS 75mm EARTH FACES, AND 50mm OTHER FACES
1-13. THE CONTRACTOR SHALL EXERCISE ALL NECESSARY CARE AND DILIGENCE IN THE 70mm ATTACHED TO WATER - DIRECTIONALITY FACTOR 0.85 (TABLE 6-4)
EXECUTION OF THE WORKS SUCH THAT THE EXISTING BUILDINGS, ROADS, PAVEMENTS - TOPOGRAPHIC FACTOR, Kzt 1.00 (TABLE 6-4)
AND UTILITIES ARE NOT AFFECTED. SUSPENDED FLOOR SLABS / STIARS / RAMPS 40mm EXTERNAL, AND 30mm INTERNAL
- WINDWARD COEFFICIENT, cp 0.80
SUSPENDED FLOOR BEAMS / LINK BEAMS 50mm ALL SIDES - LEEWARD COEFFICIENT 0.50
1-14. PRIOR TO THE COMMENCEMENT OF THE WORKS THE CONTRACTOR SHALL SUBMIT A - LOADING CASE "ASCE7-05 ALL CASES (Fig. 9-6)
PRE-CONDITION SURVEY REPORT OF THE NEIGHBORING GROUND, ROADS AND WATER TANKS 50mm ALL SIDES
STRUCTURES SURROUNDING THE PROPOSED SITE AND THE RESULTS OF CADASTRAL - GUST FACTOR 1
SURVEY CONFIRMING THE SITE BOUNDARY LINE WITH HIS/HER OWN EXPENSES. PARAPET 30mm ALL SIDES
6
1-15. BEFORE EXCAVATIONS ARE CARRIED OUT NEAR UTILITY SERVICES BY MEANS OF 3-2-2 SEISMIC LOADS BASED ON UBC1997, WITH THE FOLLOWING DATA
MECHANICAL PLANT, THE CONTRACTOR SHALL CARRY OUT FULL AND ADEQUATE 2-13. THE MAXIMUM AGGREGATE SIZE SHALL BE 20mm FOR ALL CONCRETE MIX, UNLESS NOTED
PRELIMINARY INVESTIGATIONS BY MEANS OF HAND-DUG INSPECTION PITS. OTHERWISE
- SEISMIC ZONE 2A 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
1-16. THE CONTRACTOR SHALL LIAISE WITH UTILITY UNDERTAKERS, OBTAIN THEIR APPROVAL 2-14. THE REACTIVE ALKALI CONTENT OF CONCRETE EXPRESSED AS THE EQUIVALENT SODIUM - SEISMIC ZONE FACTOR 0.15 TABLE (16-I) AUTHORITY APPROVAL 0 08.08.2017 NS
AND PAY ALL COSTS FOR THE TREATMENT AND DISPOSAL OF SEWAGE AND OXIDE CONTENT / CUBIC METER OF CONCRETE SHOULD NOT EXCEED 3.0kg. Purpose of Issue Rev. Date Appoved
WASTEWATER FROM THE SITE TO THEIR APPROVAL. - SOIL PROFILE TYPE SC (TO BE CONFIRMED BY SOIL REPORT)
Client:
- IMPORTANCE FACTOR 1.00 TABLE (16-K)
2-15. ALL BARS TO BE HIGH YIELD DEFORMED BARS TYPE II AND CONFORM WITH BS 4449:2005
1-17. THE CONTRACTOR SHALL NOT DO OR PERMIT ANYTHING TO BE DONE WITHIN THE SITE THAT AND WITH A GUARANTEED MINIMUM YIELD STRESS OF 460 N/mm2 . - IMPORTANCE OVER STRENGTH FACTOR 4.50 FOR SHEAR WALL LATERAL SYSTEM
MAY BECOME A NUISANCE OR ANNOYANCE TO THE OCCUPANTS OF NEARBY PREMISES.
5 - SEISMIC COEFFICIENT (Ca) 0.18 TABLE (A6-Q)
2-16. UNLESS NOTED OTHERWISE, ALL LAP LENGTH AND ANCHORAGE VALUES OF - SEISMIC COEFFICIENT (Cv) 0.25 TABLE (16-R) MEYDAN L.L.C
1-18. THE CONTRACTOR SHALL PROPOSE MEASURES ON GROUNDWATER CONTROL WITHIN THE REINFORCEMENT SHALL BE IN ACCORDANCE WITH AMERICAN STANDARD (ACI 318-11) P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
SITE TO ENSURE DRY EXCAVATION IN RESPECT TO THE NATURE OF THE GROUND. E: info@dubairacingclub.com W: www.dubairacingclub.com
2-17. REINFORCEMENT CONSISTING OF EXPANDED METAL LATH OR WIRE FABRIC Principal Consultant:
1-19. THE CONTRACTOR SHALL BE RESPONSIBLE FOR GETTING APPROVAL OF EASEMENT FROM (MIN. 0.5 kg/m2 ) WITH 2mm DIAMETER WIRE AT NOT MORE THAN 100mm CENTERS OR A
RELEVANT AUTHORITY OR OWNER FOR INSTALLATION OF GROUND ANCHORS PROTRUDED CONTINUOUS ARRANGEMENT OF LINKS AT NOT MORE THAN 200mm CENTERS SHALL BE 3-4. THERMAL VARIATION
OUTSIDE SITE BOUNDARY. INCORPORATED IN THE CONCRETE COVER (BOTTOM AND SIDE FACES ONLY) AT A
DISTANCE NOT EXCEEDING 30mm FROM THE FACE. - SUPER - STRUCTURE ∆ T = +/- 20° abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com
1-20. NO ROCK REMOVAL BY BLASTING IS ALLOWED WITHOUT PRIOR APPROVAL OF THE ENGINEER - SUB - STRUCTURE ∆ T = +/- 10° Hassanicor Building, 6th Floor, Al Barsha 1
AND AUTHORITY. 2-18. ALL COUPLERS IF APPLICABLE SHALL BE SCREWED COUPLERS AND PO Box 54115 Dubai, UAE
4 WELDABLE SCREWED COUPLERS OR EQUIVALENT APPROVED AND SHALL BE CAPABLE P: +971 4 3997758 F: +971 4 3997759
OF TRANSFERRING THE FULL DESIGN TENSION, COMPRESSION CAPACITY OF THE 3-5. EARTH PRESSURE Sub-Consultant:
1-21. ALL BIDDERS / CONTRACTORS SHALL BE OBLIGED TO VISIT THE SITE AND ASSESS THE SITE CONNECTED REINFORCEMENT. THE COUPLERS SHALL BEINSTALLED ACCORDING TO THE
CONDITION PRODUCT SPECIFICATIONS. - UNIT WEIGHT OF DRY SOIL = 18kN/m3
- UNIT WEIGHT OF SATURATED SOIL = 20kN/m3
2-19. COUPLER SHALL BE USED WHERE THE REINFORCEMENT PERCENTAGE
2. NOTES ON STRUCTURAL CONCRETE AT LAPPING LOCATIONS EXCEEDS 8%. - UNIT WEIGHT OF WATER SOIL = 10kN/m3

2-1. STRUCTURAL CONCRETE NOTES TO BE READ IN CONJUNCTION WITH ALL RELEVANT 3-6. CONSTRUCTION MATERIAL DENSITIES Project Name:
ARCHITECTURAL / MEP DRAWINGS, SPECIFICATIONS, AND EMPLOYER REQUIREMENTS. DENSITY
3
MATERIAL
(kN/m3) DUBAI WATER CANAL
2-2. ALL CONCRETE WORKS SHALL CONFORM WITH ACI318-11. STEEL 78.50 SAFA A
REINFROCED CONCRETE 25 DUBAI-UAE
2-3. ALL CEMENT SHALL BE ORDINARY PORTLAND CEMENT (CEM1).
PLAIN CONCRETE 22 Project Description:
2-4. WELDING OF REINFORCEMENT IS NOT PERMITTED.
MIXED USE DEVELOPMENT
2-5. ALL AREAS WHERE CONCRETE IS TO BE PLACED MUST BE CLEANED AND FREE OF (RETAIL & RESIDENTIAL)
STANDING WATER IMMEDIATELY BEFORE PLACING OF CONCRETE.
PLOT 02 / 3435336
4. PROJECT GENERAL LIMITATIONS
2 2-6. CORROSION INHIBITOR SHALL BE PROVIDED TO THE CONCRETE MIX FOR ALL SUB BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
STRUCTURE ELEMENTS. INCLUDING PILES, EXCEPTING SHORING PILES.
4-1. THE SLABS BELOW THE TRANSFER FLOOR LEVEL ARE NOT DESIGNED TO SUPPORT Drawing Title:
OWN WEIGHT OF THE TRANSFER SLABS/ BEAMS, SO THE CONTRACTOR SHALL KEEP
2-7. FOR DETAILS OF CONCRETE FINISHES, REFER TO ARCHITECTURAL DRAWINGS. THE SCAFFLODING FROM THE FOUNDATION LEVEL UP TO TRANSFER LEVEL UNTIL 56 DAYS
AFTER CASTING TRNASFER FLOOR OR AS INSTRUCTED BY THE ENGINEER. STRUCTURAL GENERAL NOTES - 01
2-8. MASS CONCRETE FILL (PLAIN CONCRETE) SHALL COMPLY WITH ACI318-11 UNLESS NOTED
OTHERWISE. 4-2. PT SPECIALIST SHALL CONSIDER ALL THERMAL EFFECT ON PT SLABS AND BEAMS IN
COLLABORATION WITH THE MAIN CONSULTANT.
Scale Drawn Checked Approved Size
2-9. ALL R.C. ELEMENTS ARE DESIGNED TO AMERICAN STANDARD ACI 318-11 AA MA NS
1 N.T.S A1
26.05.2016 24.08.2017 24.08.2017
2-10. 75mm THICK BLINDING SHALL BE LAID UNDERNEATH FOUNDATIONS / PILE CAPS
Drawing Number Rev.

14011603-02-02-00-SG0002 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

5. NOTES ON PILES DUBAI MUNICIPALITY STAMP:


DEWATERING - THE CONSTRUCTION OF SHORING WALL AND ELS WORKS SHALL NOT INDUCE ANY ADVERSE
5-1. UNLESS OTHERWISE INDICATED ON DRAWINGS, ELEVATIONS ARE IN METERS,DIMENSIONS AND
DEWATERING SHALL BE SWITCHED OFF 28 DAYS AFTER CASTING COMPLETE THE ENTIRE EFFECT ON ADJACENT STRUCTURES, UTILITIES AND FACILITIES. A DETAILED ANALYSIS ON
REINFORCEMENT BAR SIZES IN mm THE MOVEMENT OF THE SHORING WALL AND THE ADJACENT GROUND/STRUCTURES, AND A
GROUND FLOOR SLAB AND SHALL BE APPROVED IN WRITING BY THE ENGINEER.
11
5-2. DESIGN AND CONSTRUCTION OF PILES ARE IN ACCORDANCE WITH THE BUILDING CODE DETAILED ASSESSMENT ON THE EFFECT ON ADJACENT STRUCTURE, UTILITIES AND
REQUIREMENTS FOR STRUCTURAL CONCRETE ACI 318-08 AND ALSO SHALL COMPLY ALL LOCAL Important Note: FACILITIES SHALL BE CARRIED OUT BY THE CONTRACTOR TO THE SATISFACTION OF THE
REGULATIONS/CODES OF DUBAI. ENGINEER. THE LATERAL MOVEMENT OF THE SHORING WALL SHALL BE LIMITED TO 30mm IN
HIGH STRAIN DYNAMIC LOAD TEST, LOW STRAIN INTEGRITY TEST & CROSS HOLE LOGGING
5-3. THE SPECIFIED 28 DAY CYLINDER COMPRESSIVE STRENGTH OF CONCRETE (FOR PILES) IS 40 N/mm . INTEGRITY TEST SHALL BE DONE ON THE NON WORKING COMPRESSION PILES BEFORE THE ALL CASE UNLESS OTHERWISE APPROVED BY THE ENGINEER. THE MAXIMUM ALLOWABLE
5-4. TRIAL MIXES MUST BE PERFORMED AND 28 DAY COMPRESSIVE STRENGTHS & DURABILITY EXECUTION OF THE STATIC AXIAL COMPRESSION LOAD TEST. INDUCED GROUND SETTLEMENT DUE TO THE SHORING WALL AND ELS WORKS SHALL BE
TEST RESULTS MUST BE SUBMITTED TO THE ENGINEER FOR HIS APPROVAL PRIOR TO ANY GENERALLY 50mm BUT IT SHALL NOT BE APPLIED TO STRUCTURES OR UTILITIES OF WHICH
CONCRETE WORK FOR PERMANENT WORKS. 6. NOTES FOR DESIGN OF TEMPORARY SHORING WALL,AND LATERAL MORE STRINGENT REQUIREMENT TO THE APPROVAL OF THE ENGINEER SHALL BE ADOPTED;
5-5. ALL REINFORCING STEEL BARS SHALL BE DEFORMED HIGH GRADE STEEL HAVING A MINIMUM SUPPORT SYSTEM
YIELD STRENGTH OF 460 N/mm2 TO ASTM A615. - THE LATERAL SUPPORT LAYOUT OF THE ELS WORKS DESIGNED BY THE CONTRACTOR SHALL
6-1. THE DESIGN OF TEMPORARY SHORING WALL, LATERAL SUPPORT SYSTEM AND PILING N
10 5-6. THE PILE LONGITUDINAL REINFORCEMENT SHALL EXTEND ALL OVER THE PILE FULL LENGTH. NOT OBSTRUCT THE CONSTRUCTION OF THE PERMANENT STRUCTURE WITHOUT PRIOR KEY PLAN
WORKS SHALL BE CARRIED OUT BY THE CONTRACTOR TO THE APPROVAL OF THE
5-7. THE PILE LONGITUDINAL REINFORCEMENT EXTENSION ABOVE THE CUT OFF LEVEL INDICATED IN ENGINEER, AND IF NECESSARY, RELEVANT GOVERNMENT AUTHORITIES IN DUBAI. APPROVAL BY THE ENGINEER;
THE PILE SCHEDULE SHALL NOT BE LESS THAN 50 TIMES DIA. OF THE MAIN REINFORCEMENT.
6-2. THE CONTRACTOR SHALL PREPARE AND SUBMIT IN THE TENDER THE DESIGN WITH
- THE COMBINED THICKNESS OF THE SHORING WALL INCLUDING WALL DEFLECTION,
5-8. A FULL MECHANICAL SPLICE SHALL BE USED FOR ALL LONGITUDINAL REINFORCEMENT TO DETAILED PLANS, CALCULATIONS AND EXPLANATORY NOTES. THE DRAWINGS CONSTRUCTION TOLERANCE AND ANCHOR HEAD (IF ANY SHALL NOT BE MORE THAN 1.10m
DEVELOP IN TENSION OR COMPRESSION, AS REQUIRED, AT LEAST 125% OF THE SPECIFIED INCLUDING PLANS AND SECTIONS INDICATED IN THE TENDER DRAWINGS ARE FOR UNLESS OTHERWISE AGREED BY THE ENGINEER. IN ANY CASE, THE BASEMENT AREA SHALL
YIELD STRENGTH Fy OF THE BAR. MECHANICAL COUPLERS SHALL BE TESTED IN THE INFORMATION ONLY AND IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO NOT BE SACRIFICED DUE TO CONSTRUCTION OF THE SHORING WALL;
LABORATORY IN ACCORDANCE WITH ACI 318-08. VERIFY AND UNDERTAKE HIS DESIGN.
- THE SHORING WALL AND ELS SYSTEM SHALL BE DESIGNED FOR THE HEIGHT SHOWN ON
5-9. ALL PILES SHALL BE OF CAST-IN-SITU BORED SYSTEM . 6-3. ALL TIME AND COST PERTAINING TO THE DESIGN WORKS SHALL BE SOLELY ON THE DRAWINGS.
CONTRACTOR'S EXPENSES.
5-10. NO ROCK REMOVAL BY BLASTING IS ALLOWED WITHOUT PRIOR APPROVAL OF THE ENGINEER 6-4. THE PROPOSED TEMPORARY SHORING WALL SHALL BE BASED ON THE ASSUMPTION - THE FREE LENGTH OF GROUND ANCHOR SHALL EXTEND BEYOND THE CRITICAL FAILURE
9 AND AUTHORITY. THAT TIE BACKS/ANCHORS ARE REQUIRED TO PROVIDE AS THE LATERAL SUPPORT FOR SURFACE IN THE ROCK OR SOIL MASS BEING RETAINED BY THE WALL. THE BOND LENGTH
5-11. THE CAPACITY OF THE SOIL/ROCK FOR BEARING, BOND OR FRICTION SHALL POSSESS A THE SYSTEM. HOWEVER, SHOULD THIS NOT BE POSSIBLE, ALTERNATIVES SUCH AS
MINIMUM FACTOR OF SAFETY OF 2.5 UNDER COMPRESSION AND TENSION.
SHALL BE MINIMUM OF 4m AND LOCATED A MINIMUM DEPTH OF 5m BELOW THE GROUND
CANTILEVER WALL OR INTERNAL PROPPING SYSTEMS SHALL BE CONSIDERED BY THE SURFACE "SUBJECT TO THE SOIL LAYERS & AS PER LOCAL AUTHORITY REQUIREMENTS ".
5-12. THE CONTRACTOR SHALL SUBMIT AN INSURANCE POLICY, APPROVED BY THE LOCAL CONTRACTOR AND TO SUBMIT FOR REVIEW AND ACCEPTANCE BY THE ENGINEER.
MUNICIPALITY, COVERING ALL LOCAL MUNICIPALITY REQUIREMENTS PRIOR TO WORK SELECTION OF GROUND ANCHOR INCLINATION General Notes:
6-5. THE CONTRACTOR SHALL SUBMIT WITH HIS TENDER THE FOLLOWING INFORMATION FOR
COMMENCEMENT. THE CONSIDERATION OF THE ENGINEER: SHALL CONSIDER THE LOCATION OF SUITABLE ROCK FORMATIONS, THE PRESENCE OF 1. DO NOT SCALE FROM THIS DRAWING.
5-13. ALL PILES TO HAVE A DEPTH AS SHOWN ON THE DRAWINGS AND AS RECOMMENDED BY THE BURIED UTILITIES OR OTHER GEOMETRIC CONSTRAINTS, AND CONSTRUCTABILITY OF THE 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
SOIL INVESTIGATION REPORT. HOWEVER, IT IS THE RESPONSIBILITY OF THE CONTRACTOR - DETAILED CONSTRUCTION SEQUENCE FOR AND TEMPORARY SHORING WALL
ANCHOR DRILLHOLES. GROUND ANCHORS SHALL BE LOCATED WITH AN ANGLE OF NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
TO ASCERTAIN THE DEPTH OF EACH & EVERY PILE BY CALCULATIONS BASED ON THE SOIL EXCAVATION AND LATERAL SUPPORT (ELS) WORKS INCLUDING THE TEMPORARY ROAD BY THE ENGINEER.
DIVERSION WORKS AND THE REMOVAL OF SHORING IF ANY; INCLINATION BELOW HORIZONTAL BETWEEN 15° MINIMUM AND 45° MAXIMUM AND TO
INVESTIGATION REPORT AND ON HIS OWN INVESTIGATION/FINDINGS DURING EXECUTION OF 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
THE PILING WORKS AND TO REPORT ALL DISCREPANCIES TO THE ENGINEER. - DEWATERING SYSTEM DESIGN AND THE LOCAL PUMPING TEST DESIGN SHOWING THE MINIMIZE THE EASEMENT REQUIRED; SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 - THE CONTRACTOR SHALL DEMONSTRATE THAT ANY DEWATERING FOR THE EXCAVATION AT SITE.
5-14. PILING WORKS CAN COMMENCE ONLY AFTER ALL TEST RESULTS PERFORMED ON THE LOCATIONS OF PUMPING WELLS, MONITORING WELLS AND TESTING SEQUENCES;
PRELIMINARY TEST PILES ARE REVIEWED AND APPROVED BY THE ENGINEER. - TOE STABILITY CHECK FOR TEMPORARY SHORING WALL; AND SUBSEQUENT SUBSTRUCTURE CONSTRUCTION WORKS WILL NOT CAUSE EXCESSIVE 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
5-15. THE CONTRACTOR SHOULD PROVIDE THE NECESSARY ADDITIVES AND - DESIGN CALCULATION OF TEMPORARY SHORING WALL AND ELSE WORKS WITH SETTLEMENT IN ADJACENT AREAS. IN ANY CASE, THE GROUNDWATER DRAWDOWN AND RELEVANT SECTIONS OF THE SPECIFICATION.

SUPERPLASTICIZERS IN THE CONCRETE MIX IN ORDER TO ACHIEVE THE REQUIRED NECESSARY ANALYSIS ON MOVEMENT OF SHORING WALL DUE TO OUTSIDE THE SITE SHALL BE PROPOSED BY THE CONTRACTOR AS PART OF THE
STRENGTH & DURABILITY CRITERIA. INSTALLATION, BRACED EXCAVATION AND DEWATERING AND ASSESSMENT TO DEWATERING SYSTEM DESIGN FOR REVIEW BY THE ENGINEER AND SHOULD
THE EFFECTS ON ADJACENT STRUCTURES, UTILITIES AND FACILITIES
5-16. DEWATERING CAN BE SWICHED OFF AFTER 28 DAYS FROM CASTING THE GROUND
(WHERE APPLICABLE);
DEMONSTRATE THE ASSOCIATED EFFECT ON ADJACENT GROUND AND STRUCTURES IS
FLOOR SLAB AND SHALL BE APPROVED BY THE ENGINEER. MINIMAL. THE GROUNDWATER DRAWDOWN OUTSIDE THE EARTH RETAINING WALL SHALL
- STABILITY CHECK FOR THE SHORING WALL AGAINST SLIDING, OVERTURNING AND UPLIFTING;
5-17. DESIGN SHOULD BE VERIFIED AGAINST FINAL CONDITIONS, THE CONTRACTOR SHOULD - CHECKING ON THE GEOTECHNICAL CAPACITY AND STRUCTURAL STRENGTH OF THE PILES;
BE MONITORED BY STANDPIPES/PIEZOMETERS DURING THE CONSTRUCTION PERIOD. IF
SUBMIT SHOP DRAWINGS FOR APPROVAL BEFORE FABRICATIONS. ANY ABNORMAL GROUNDWATER DRAWDOWN IS NOTED, CONTINGENCY MEASURE SUCH AS
7 - DESIGN CALCULATION OF PILING WORKS WITH NECESSARY ANALYSIS ON ANTICIPATED
5-18. PILING SUB-CONTRACTOR SHOULD SUBMIT FULL SET OF SHOP DRAWINGS AND
SETTLEMENT AND MOVEMENT OF PILING , AND ASSESSMENT TO THE EFFECTS ON THE RECHARGE WELLS WHICH SHALL BE PROPOSED BY THE CONTRACTOR AND AGREED WITH
CALCULATIONS FOR PILING WORKS FOR ENGINEER'S AND AUTHORITIES APPROVAL. PILING THE ENGINEER SHALL BE CARRIED OUT BY THE CONTRACTOR ON HIS OWN EXPENSE.
PROPOSED STRUCTURES, ADJACENT EXISTING STRUCTURES, UTILITIES AND FACILITIES
WORKS CAN COMMENCE ONLY AFTER GETTING THE REQUIRED APPROVALS.
(WHERE APPLICABLE);
5-19. CONTRACTOR SHALL DETERMINE THE CONCRETE STRENGTH AND REINFORCEMENT DETAILS 6-6. ASSUMPTIONS ON THE BOUNDARY CONDITIONS AND INTERFACING REQUIREMENTS SHALL BE
OF THE PRELIMINARY TEST PILES FOR ENGINEER'S APPROVAL. - CAL PUMPING TEST TO VERIFY THE HYDRAULIC CUT-OFF OF THE SHORING WALL SHALL
SPECIFIED AND VERIFIED WITH THE ENGINEER. IN PARTICULAR THE SURCHARGE/EXTERNAL BE DESIGNED AND CARRIED OUT PRIOR TO BASEMENT EXCAVATION. AT LEAST 3 LOCATIONS
5-20. ALL PILES SHALL BE DESIGNED TO RESIST A HORIZONTAL FORCE OF AT LEAST 5% OF THE FORCES SHALL BE CLEARLY STATED. CO-ORDINATION AMONGST THE SEQUENCE OF EXCAVATION,
VERTICAL LOAD. (U.N.O.) PILING, AND SHORING CONSTRUCTION SHALL BE INDICATED. IN THE VICINITY NEXT TO THE SHORING WALL SHALL BE SELECTED BY THE ENGINEER TO
6-7. THE CONTRACTOR'S PROPOSAL OF THE SHORING WALL AND ELSE WORKS SHALL CARRY OUT LOCAL PUMPING TESTS. THE TESTING ZONE OF EACH PUMPING TEST SHALL
5-21. FOR MORE INFORMATION AND REQUIREMENTS REFER TO SPECIFICATIONS.
COMPLY WITH THE FOLLOWING MINIMUM CRITERIA: COVER AT LEAST 5% OF THE PERIMETER OF THE SHORING WALL. THE SPACING OF THE
- THE INDUCED VIBRATION ON ADJACENT STRUCTURES/UTILITIES DUE TO THE OBSERVATION WELLS WITHIN THE BASEMENT AND STANDPIPES/PIEZOMETERS OUTSIDE THE
6 5-22. ALL WORKING AND NON WORKING TESTED PILES SHOULD BE CHOSEN BY THE CONSULTANT
ENGINEER CONSTRUCTION OF THE SHORING WALL AND ELS WORKS SHALL NOT BE MORE BASEMENT SHOULD NOT EXCEED 20m ALONG THE WALL PERIMETER.
THAN15mm/s; - TIE BACK / ANCHORS SHOULD BE TESTED IN ACCORDANCE WITH THE SPECIFICATIONS.
5-23. THE CONCRETE FOR PILES SHALL BE AS PER PROJECT SPECIFICATIONS. -CONCRETE
MIX DESIGN DETAILS & TRIAL MIX TEST RESULTS SHALL BE SUBMITTED TO ENGINEER FOR IMPORTANT NOTES 6-8. THE CONTRACTOR'S PROPOSAL OF ENABLING WORKS SHALL COMPLY WITH THE FOLLOWING 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
APPROVAL. MINIMUM CRITERIA: - AUTHORITY APPROVAL 0 08.08.2017 NS
(a) THE CONTRACTOR MUST OBTAIN ALL REQUIRED NOCS' FROM RTA AND ALL RELEVANT
5-24. THE TOTAL LENGTH OF THE PILE IS THE RESPONSIBILITY OF THE CONTRACTOR SO THAT - THE INDUCED VIBRATION ON ADJACENT STRUCTURES/UTILITIES DUE TO THE Purpose of Issue Rev. Date Appoved
AUTHORITIES FOR ENABLING WORKS.
THE PILE CAN ACHIEVE THE REQUIRED LOAD CARRYING CAPACITY & SATISFY THE CONSTRUCTION OF SHORING AND PILING SHALL NOT BE MORE THAN 15mm/s; Client:
LOADING TEST. DETAILS OF PILE LENGTH TO BE SUBMITTED TO CONSULTANTS FOR - THE AVERAGE COMPRESSIVE STRESS OF CONCRETE PILE SHAFT IMPOSED BY WORKING
APPROVAL AS PER SOIL INVESTIGATION REPORT.
LOAD SHALL NOT EXCEED 33% OF THE DESIGN GRADE STRENGTH OF THE CONCRETE.
5-25. ALL PILES SHALL BE CAPABLE OF CARRYING THE WORKING LOADS INDICATED IN THE
5 PILE SCHEDULES, ALLOWABLE VERTICAL DISPLACEMENT (SETTLEMENT) SHALL BE IN STANDARD CONDITIONS OF NOC - THE CAPACITY OF THE SOIL/ROCK FOR BEARING, BOND OR FRICTION SHALL POSSESS
MINIMUM FACTORS OF SAFETY OF 2.5 UNDER COMPRESSION AND TENSION MEYDAN L.L.C
ACCORDANCE WITH SPECIFICATION ALLOWABLE HORIZONTAL DISPLACEMENT NOT THE METHOD OF SHORING THE BASEMENT EXCAVATION IS APPROVED SUBJECT TO THE FOLLOWING: P.O. Box 9305, Dubai , UAE.
EXCEED 5mm. OF PERMANENT DEFORMATION AT WORKING LOADS. RESPECTIVELY. T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com
1. TRIAL PITS MUST BE TAKEN BY CAREFUL HAND EXCAVATION TO LOCATE THE EXISTING - CONE FAILURE SHALL BE CHECKED FOR TENSION PILE SOCKETTED INTO ROCK. THE Principal Consultant:
SERVICES BEFORE BORING OF SECANT PILES THE TRIAL PITS SHALL BE RESTRICTED TO MINIMUM FACTOR OF SAFETY AGAINST CONE FAILURE SOLELY BY SUBMERGED WEIGHT OF
PILE TESTING ROCK/SOIL MASS SHALL BE 1.1;
UNMADE AREAS AROUND THE PLOT LINE AS FAR AS POSSIBLE.
-LOAD TESTING OF PILES SHALL BE CARRIED OUT IN ACCORDANCE WITH SPECIFICATIONS, AND AS FOLLOWS : IN THE EVENT OF EXISTING PAVED AREAS AROUND THE PLOT LINE REQUIRING EXCAVATION FOR - THE ANTICIPATED ABSOLUTE SETTLEMENT, ANGULAR DISTORTION AND LATERAL MOVEMENT abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh

LOCATING SERVICES AND INSERTION OF PILES, A SEPARATE ROAD CUTTING NOC OF THE SHORING WALL AND PILING SHALL GENERALLY NOT EXCEED 25mm, 1/500 AND 30mm www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1

WILL HAVE TO BE OBTAINED FROM RTA BEFORE ANY CUTTING IS MADE.


RESPECTIVELY, UNLESS SUCH SETTLEMENT OR LATERAL MOVEMENT CAN BE TOLERATED PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4 1) STATIC AXIAL COMPRESSION LOAD TEST BY THE PROPOSED STRUCTURES AND HAS MINIMAL ADVERSE EFFECT ON THE ADJACENT Sub-Consultant:
NON WORKING TEST PILES, "250% ALLOWABLE LOAD" STRUCTURES, UTILITIES AND FACILITIES (WHERE APPLICABLE);
2. ALL EXISTING SERVICES AND ROAD STRUCTURES WILL HAVE TO BE PROTECTED AT ALL TIMES - NO BENEFICIAL GROUNDWATER UPLIFT FORCE SHALL BE CONSIDERED TO DEDUCE THE
PILE TEST TYPE ALLOWABEL LOAD TEST LOAD PILE PILE AND ANY DAMAGES TO THEM WILL BE TREATED AS VIOLATION OF LAW No.2/94 AND LOCAL
TYPE "kN" "kN" DIAMETER "mm" LENGTH "m" COMPRESSION LOAD OF THE PILE;
ORDER No. 84/94 ON THE PART OF BUILDING CONTRACTOR, AND WILL BE TREATED AS SUCH.
- THE MINIMUM FACTOR OF SAFETY OF THE SHORING WALL AGAINST SLIDING, OVERTURNING
IN ADDITION THE REIMBURSEMENT OF ALL COSTS OF REPAIRS WILL BE TO THE OWNER'S ACCOUNT.
TYPE 4
STATIC AXIAL COMPRESSION NON
4,885 12,215 750 24.00 AND UPLIFT SHALL BE 1.50
WORKING LOAD TEST
3. THIS NOC IS ISSUED AS A GENERAL TECHNICAL GUIDANCE TO THE OWNER AND DUBAI MUNICIPALITY - THE MAXIMUM CRACK WIDTH IN PILES SHALL NOT EXCEED 0.2mm Project Name:
BEARS NO RESPONSIBILITY TOWARDS ANY COLLAPSE OF SIDE WALLS OR ANY
3 TO ANY PARTY WHATSOEVER.OTHER MISHAPS OCCURRING 6-9. DESIGN OF THE SHORING WALL, ELS WORKS AND PILING SHALL COMPLY WITH ALL DUBAI WATER CANAL
2) STATIC AXIAL COMPRESSION LOAD TEST
LOCAL REGULATIONS/CODES IN DUBAI. SAFA A
WORKING TEST PILES, "150% ALLOWABLE LOAD"
1% OF THE TOTAL NUMBER OF PILES TO BE TESTED NO OBJECTION FROM AUTHORITIES N.O.C SUBJECT TO THE FOLLOWING 6-10. THE PROPOSED SHORING WALL AND ELS WORKS SHALL BE CAPABLE TO RETAIN THE LEVEL DUBAI-UAE
3) STATIC AXIAL TENSION LOAD TEST DIFFERENCE AND COPE WITH THE CONSTRUCTION ACTIVITIES UNDERTAKEN IN THE NEARBY.
1. THE CONTRACTOR MUST CARRY OUT THE WORK CAREFULLY TO AVOID DAMAGE OF EXISTING SERVICES. THE DESIGN SHALL SATISFY BOTH ULTIMATE LIMIT STATE AND SERVICEABILITY LIMIT STATE
WORKING TEST PILES, "150% ALLOWABLE LOAD" Project Description:
ONE PILE TO BE TESTED 2. PROGRAME OF THE ABOVE WORKS MUST BE COORDINATED WITH DUBAI MUNICIPALITY, CONTRACTOR IN ACCORDANCE WITH CIRIA REPORT NO. C580 UNLESS OTHERWISE AGREED BY THE ENGINEER. MIXED USE DEVELOPMENT
AND CONSULTANT WITHIN THE AREA.
PILE ALLOWABEL LOAD TEST LOAD PILE PILE 3. F.I.C DETAILS TO BE RECONFIRMED WITH DUBAI MUNICIPALITY DRAINAGE & IRRIGATION DEPARTMENT
6-11. THE SHORING WALL AND ELS WORKS SHALL BE DESIGNED TO SUPPORT THE SURCHARGE OF (RETAIL & RESIDENTIAL)
TEST TYPE
TYPE "kN" "kN" DIAMETER "mm" LENGTH "m" BEFORE FINALISING THE INTERNAL PIPE WORK.
MINIMUM 20 kPa. THE SURCHARGE CONDITION SHALL BE DESIGNED BY THE CONTRACTOR TO PLOT 02 / 3435336
2 THE APPROVAL OF THE ENGINEER AND DULY INCORPORATED IN HIS DESIGN OF THE EARTH BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
STATIC AXIAL TENSION 4. TEMPORARY HOARDING OUT WITH THE BUILDING LINE TO BE AGREED WITH DUBAI MUNICIPALITY RETAINING WALL.
TYPE 7a 1500 2,250 900 28.00 AND CONSULTANT.
WORKING LOAD TEST Drawing Title:
5. THE CONTRACTOR IS RESPONSIBLE TO PROTECT EXISTING SEWERAGE/ DRAINAGE/IRRIGATION/HOUSE 6-12. CONTRACTOR'S ATTENTION IS DRAWN TO THE POSSIBLE UNDERGROUND OBSTRUCTION
4. HIGH STRAIN DYNAMIC LOAD TEST . CONNECTION LINE. ANY DAMAGED TO THESE SERVICES WILL BE CHARGED TO CONCERN PARTY. SUCH AS FOUNDATIONS OF OLD STRUCTURES. METHOD OF OVERCOMING UNDERGROUND
WORKING TEST PILES ………. 5% WORKING PILES OF THE TOTAL NUMBER FOR EACH PLOT. 6. LEVEL OF OUR EXISTING SERVICES ARE TO BE CONFIRMED BEFORE COMMENCING THE SHORING OBSTRUCTION SHALL BE PROPOSED BY THE CONTRACTOR TO THE APPROVAL OF THE ENGINEER STRUCTURAL GENERAL NOTES - 02
5. LOW STRAIN INTEGRITY TEST (PULSE ECHO OR SONIC ECHO). AND ANCHORING OPERATIONS. 6-13. CONSTRUCTION RECORDS SHALL BE SUBMITTED TO THE ENGINEER FOR RECORD AT TIMING
WORKING TEST PILES ………. 100% WORKING PILES OF THE TOTAL NUMBER OF EACH PLOT. AGREED BY THE ENGINEER. DETAILS OF SUBMISSION SHALL BE APPROVED BY THE ENGINEER
PRIOR TO CONSTRUCTION OF WORKS. Scale Drawn Checked Approved Size
6. CROSSHOLE SONIC LOGGING INTEGRITY TEST . AA MA NS
1 WORKING TEST PILES ………. 10% WORKING PILES OF THE TOTAL NUMBER OF EACH PLOT. 6-14. THE DESIGN OF THE SHORING WALL, ELS WORKS AND PILING WORKS SHOULD BE SUBMITTED N.T.S A1
TO THE LOCAL GOVERNMENT AUTHORITIES IN DUBAI FOR APPROVAL PRIOR TO WORKS 26.05.2016 24.08.2017 24.08.2017
COMMENCEMENT, THE CONTRACTOR SHALL BE RESPONSIBLE TO RESPONSE TO ANY QUERIES Drawing Number Rev.
FROM THE GOVERNMENT AUTHORITIES AND TO THEIR SATISFACTION/APPROVAL. 14011603-02-02-00-SG0003 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11
8. ABBREVIATIONS 9. GRAPHIC SYMBOLS & REFERENCES KEYS 10. DRAWINGS ORGANIZATIONS:
AB - ADDITIONAL BOTTOM REINFORCEMENT
ADD - ADDITIONAL - REINFORCED CONCRETE
ALT - ALTERNATIVE
ARB - ARCH BEAM
AT - ADDITIONAL TOP REINFORCEMENT - BLINDING 10-1. DRAWING NUMBERING SYSTEM
B - BEAM - BREAK LINE
BLK - REINFORCED BLOCK WORK IN GENERAL CASE THE DRAWING NUMBER FOR EACH SHEET CONSISTS OF THE FOLLOWING: N
10 KEY PLAN
BOTT (B) - BOTTOM
- SLOPE
BR
BRK
-
-
BRACING
BRICK WALL 14011603 - 00 - 01 - S0000
BW - BOTH WAYS
- OPENING / SLEEVES IN THE STRUCTURAL ELEMENT
C - CONCRETE COLUMN
DRAWING GROUP NUMBER
CA - CANTILEVER BEAM
DISCIPLINE CODE
C/C - CENTERS
CHQ - CHECKERED PLATE - COMPACTED SOIL
CIP - CAST-IN-PLACE BUILDING NUMBER
9 PLOT CODE
CL - CENTER LINE
PROJECT NUMBER
DIA/Ø - DIAMETER
DWG - DRAWING - STRUCTURAL LEVEL (ELEVATION / SECTION)
DIAPH - DIAPHRAGM 10-2. BUILDING NUMBER General Notes:
DET - DETAIL
- GROUND LEVEL (ELEVATION / SECTION) 1. DO NOT SCALE FROM THIS DRAWING.
ALL BUILDINGS ARE CLASSIFIED ACCORDING TO THE FOLLOWING:
EL - EXISTING LEVEL 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
EF - EACH FACE 00 = GENERAL NOTES AND STANDARD DETAILS, BASEMENT AND GROUND BY THE ENGINEER.
EW - EACH WAY 01 = BUILDING 01
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
(E.J.) - EXPANSION JOINT - STRUCTURAL SLAB ON PLANS 02 = BUILDING 02 SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.
ELEV - ELEVATION 03 = BUILDING 03
04 = BUILDING 04 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
FL - FOUNDATIONS LEVEL ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS

FFL - FINISHED FLOOR LEVEL - SLAB THICKNESS ON PLANS 280 AND RELEVANT SECTIONS OF THE SPECIFICATION.

FGL - FINISHED GROUND LEVEL


G - GRADE OF STEEL BOLT / ANCHOR - WALL THICKNESS ON PLANS (250) 10-3. DISCIPLINE CODE
GB - GROUND BEAM
GND - GROUND ALL DRAWINGS ARE CLASSIFIED ACCORDING TO THE FOLLOWING DISCIPLINES:
HB - HIDDEN BEAM G = GENERAL DRAWINGS
HCS - HOLLOW CORE SLAB - STEP IN LEVEL ON PLANS A = ARCHITECTURE
7
HR/HL - HORIZONTAL S = STRUCTURAL ENGINEERING
(&) - AND M = MECHANICAL ENGINEERING
(@) - AT - SETTING OUT POINT E = ELECTRICAL ENGINEERING
(%) - PERCENT I = INTERIOR DESIGN
(±) - PLUS/MINUS L = LANDSCAPE
LB - LINTED BEAM
- DETAIL MARK / REFERENCE
C = CIVIL
LVL - LEVEL
10-4. DRAWING GROUP NUMBER
M - DIAMETER OF BOLT / ANCHOR
6 MAX - MAXIMUM
MIN - MINIMUM STRUCTURAL DRAWINGS ARE ORGANIZED INTO THE FOLLOWING
SECTION
GROUPS:
NTS - NOT TO SCALE
- SECTION REFERENCE 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
DRAWING No. SC1000 = COLUMN LAYOUT
P - PILE AUTHORITY APPROVAL 0 08.08.2017 NS
PB - PRE-STRESSED BEAM SF1000 = FRAMING LAYOUT Purpose of Issue Rev. Date Appoved
PC - PILE CAP SR1000 = REINFORCEMENT LAYOUT Client:
(P.C.) - PLAIN CONCRETE (BLINDING) S5000 = DETAILS
PL - STEEL PLATE - REINFORCEMENT DETAILS
S6000 = SCHEDULES
PLc - PLANTED COLUMN F1
5 PD - PEDESTAL COLUMN FAR FACE (OUTER LAYER) --- F1
PS - PUNCHING SHEAR FAR FACE (SECOND LAYER) --- F2 F2 MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
PT - POST-TENSIONING SLAB NEAR FACE (OUTER LAYER) --- N1 T: +9714 3270000 F: +9714 3270007
N1 E: info@dubairacingclub.com W: www.dubairacingclub.com
R - MILD STEEL NEAR FACE (SECOND LAYER) --- N2 Principal Consultant:
N2
(R.C.) - REINFORCED CONCRETE BOTTOM FACE (LOWER LAYER) --- B1
RFT - REINFORCEMENT
BOTTOM FACE (SECOND LAYER) --- B2 T1 T2
RW - RETAINING WALL
S - WELDING SIZE TOP FACE (UPPER LAYER) --- T1 abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com
SB - STRAP BEAM TOP FACE (SECOND LAYER) --- T2 Hassanicor Building, 6th Floor, Al Barsha 1
SB - STEEL BEAM PO Box 54115 Dubai, UAE
B1 B2 P: +971 4 3997758 F: +971 4 3997759
4 SC - STEEL COLUMN Sub-Consultant:
SG - STEEL GIRDER
S.O.G - SLAB ON GRADE DISTRIBUTION LENGTH
SOL - SETTING OUT LINE
SOP - SETTING OUT POINT
SQ - SQUARE TOTAL NO. OF BARS
4000
SSL - STRUCTURAL SLAB LEVEL (20)
STG - STAGGERED
T16@200 (AT)

Project Name:
STIFF - STIFFENER PLATE
L=4.00m

4000
(20)

3 T - TOP DUBAI WATER CANAL


T - HIGH TENSILE STEEL T16@200mm (AT)
SAFA A
TB - TIE BEAM L=4.00m
THK - THICKNESS DUBAI-UAE
TL - TOP LEVEL
T.O.C - TOP OF CONCRETE Project Description:
T.O.B - TOP OF BEAM
T.O.P - TOP OF PARAPET *C32/40 MIXED USE DEVELOPMENT
T.O.S - TOP OF STEEL - CONCRETE STRENGTH CUBE STRENGTH OF CONCRETE (RETAIL & RESIDENTIAL)
TRB - TRANSFER BEAM
CYLINDER STRENGTH OF CONCRETE
PLOT 02 / 3435336
2 TRG - TRANSFER GIRDER BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
TYP - TYPICAL
Drawing Title:
U.N.O - UNLESS NOTED OTHERWISE - SLABS SPANS AND TYPE

VR/VL - VERTICAL
THK. THK. THK. STRUCTURAL GENERAL NOTES - 03
THK.

W - WALL
WF - WITH FLOOR CANTL.
WS - WITH STAIR
ONE WAY SLAB TWO WAY SLAB CANTILEVER SLAB Scale Drawn Checked Approved Size
AA MA NS
1 N.T.S A1
26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-02-02-00-SG0004 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

N
10
11. POST-TENSIONED CONCRETE NOTES KEY PLAN

11-1. GENERAL
11-8. MISCELLANEOUS 11-23. ADDITIONAL CONCRETE REQUIREMENTS FOR POST TENSIONING
11-1-1. ALL POST-TENSIONING WORKS SHALL BE CARRIED OUT IN ACCORDANCE
WITH ACI 318-11 STRUCTURAL USE OF CONCRETE AND TR-43
a) NO DRILLING OR BREAKING OUT OF THE SLAB SHALL BE PERMITTED WITHOUT A. ALL CONCRETE TEST CYLINDERS SHALL BE SITE CURED UNDER CONDITIONS
11-1-2.
- FORMWORK SHALL BE DESIGNED TO SUPPORT THE REACTIONS DURING PRIOR APPROVAL. CONSISTENT WITH THE CONCRETE POUR.
STRESSING.
9 b) (i) SHOULD SMALL FIXINGS BE REQUIRED FOR THE SUSPENSION OF SERVICES, B. MAXIMUM SHRINKAGE STRAIN AT 56 DAYS, SHALL BE 600x10-6 MICROSTRAIN.
DRILLING INTO THE CONCRETE SHALL BE BY STANDARD 'MASONRY BIT' TYPE DRILLS ONLY
AND SHALL ONLY BE PERMITTED SUBJECT TO APPROVAL. C. TO PREVENT DAMAGE TO STRESSING TENDONS AND REINFORCEMENT, CONCRETE
11-2. STRAND PROPERTIES
PUMP LINES SHALL BE ADEQUATELY RESTRAINED AND SUPPORTED ON STOOLS General Notes:
OR TIMBER BLOCKS.
11-2-1. ALL STRANDS SHALL COMPLY WITH ACI 318-11 SEVEN WIRE STEEL STRAND FOR
PRESTRESSED CONCRETE. (ii) ALL DUCTS SHALL BE FULLY GROUTED AND DUCT POSITIONS PERMANENTLY MARKED D. SLURRY USED TO LUBRICATE CONCRETE PUMP LINES SHALL NOT BE
1. DO NOT SCALE FROM THIS DRAWING.
ON SOFFITS BEFORE ANY DRILLING COMMENCES. UNDER NO CIRCUMSTANCES SHALL ANY USED IN ANY STRUCTURAL MEMBER. 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
STRAND TYPE : SUPER DRILL BIT OR CORE BE USED WHERE THIS CAN PENETRATE STEEL (i.e. DIAMOND DRILL NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.
BIT OR DIAMOND CORE)
NOMINAL DIAMETER : 12.7 mm 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
11-24. ADDITIONAL REINFORCEMENT REQUIREMENTS FOR POST TENSIONING SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 NOMINAL AREA : 99 mm2 AT SITE.
TENSILE STRENGTH : 1770 N/mm2 A. TOP REINFORCEMENT SHALL NOT BE LAID UNTIL AFTER TENDONS
11-9 SUBMIT ALL TEST CERTIFICATES, CALCULATIONS AND WORKSHOP DRAWINGS TO 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
HAVE BEEN PLACED.
MINIMUM BREAKING L0AD : 184 kN THE ENGINEER PRIOR TO CONSTRUCTION. ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.
YOUNG'S MODULUS : 195GPa
11-10. ALL STRESSING EQUIPMENT AND GAUGES SHALL POSSESS CURRENT CALIBRATION 11-25. EXTERNAL STRESSING POCKET TREATMENT NOTES
MAX. RELAXATION AT 1000 Hrs : 2.5 %
(AT 80% Pult) CERTIFICATES AVAILABLE TO THE CONSULTING ENGINEER UPON REQUEST.
11-25-1. ALL STRESSING EQUIPMENT AND GAUGES SHALL POSSESS CURRENT CALIBRATION
CERTIFICATES AVAILABLE TO THE CONSULTING ENGINEER UPON REQUEST.
11-3. TENDON DESIGN PARAMETERS 11-11. TENDONS SHALL BE LOCATED IN ACCORDANCE WITH THE DRAWINGS TO A
VERTICAL TOLERANCE OF +/- 5.0mm. A. CUT BACK STRAND ENDS AS FAR AS POSSIBLE.
7 11-3-1. THE FRICTION PARAMETERS ASSUMED FOR THE DESIGN ARE AS FOLLOWS:
11-12. TENDONS SHALL BE SECURELY FIXED IN POSITION AT MAXIMUM 1200mm CTS. B. DEGREASE AND WIRE BRUSH STRAND ENDS AND ANCHOR POCKET AND
SLAB TENDON ALONG THE LENGTH. ALLOW TO DRY.
FRICTION COEFFICIENT u = 0.20/radian
WOBBLE FACTOR k = 0.002/m 11-13. TENDONS ARE GENERALLY TO HAVE A PARABOLIC PROFILE WITHIN SPANS UNLESS C. EPOXY COAT STRAND ENDS AND ANCHOR.
WEDGE DRAW-IN l = 6.0mm NOTED OTHERWISE, AND SHALL CONFORM TO GIVEN PROFILE POINTS.
D. FILL ANCHOR POCKET WITH NON-SHRINK GROUT
11-4. TENDON SIZES (MASTERFLOW 870 BY MDT OR SIMILAR) FLUSH WITH SLAB.
11-14. TENDON HEIGHTS GIVEN ON DRAWINGS ARE MEASURED FROM THE SOFFIT
OF BEAM AS FOLLOWS: E. IMMEDIATELY COVER GROUTED POCKET WITH PLASTIC COVER SECURELY TAPED
11-4-1. ALL TENDONS SHALL BE FORMED FROM THE STRANDS WITH THE PROPERTIE
6 STATED IN NOTE 2 ABOVE. AROUND ALL FOUR EDGES TO PROMOTE MOIST CURING OF GROUT.
AT ANCHORAGES :- TO CENTERLINE OF ANCHOR
11-4-2. ALL TENDONS SHALL BE VSL MULTISTRAND SYSTEM UNLESS OTHERWISE F. LEAVE PLASTIC COVER ON FOR 7 DAYS MINIMUM.
NOTED ON THE TENDON LAYOUT DRAWINGS, OR EQUIVALENT TO THE ELSEWHERE :- TO UNDERSIDE OF DUCT.
G. REMOVE PLASTIC AND APPLY ACRYLIC WATERPROOFING MEMBRANE, COMPATIBLE 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
ENGINEER'S APPROVAL.
11-15. TENDON PROFILES SHALL HAVE PRECEDENCE OVER OTHER WITH THE SPECIFIED PAINT SYSTEM, EXTENDING PAST THE GROUTED POCKET TO AUTHORITY APPROVAL 0 08.08.2017 NS
11-5. TENDON SET OUT REINFORCEMENT AND SERVICE CONDUITS. THE EXPOSED SLAB EDGE. Purpose of Issue Rev. Date Appoved
Client:
11-16. STRESSING PROCEDURE: H. ALLOW ACRYLIC MEMBRANE TO CURE BEFORE APPLICATION OF SPECIFIED PAINT
11-5-1. ALL TENDONS SHALL BE SET OUT TO THE POSITION AND PROFILES SPECIFIED SYSTEM OVER.
ON THE TENDON LAYOUT DRAWINGS.
i) STRESS EACH INDIVIDUAL STRAND OF ALL TENDONS TO 25% U.T.S AT APPROX. 24HRS.
5 (FCP=7/9MPa MINIMUM) AFTER COMPLETION OF POUR.
11-5-2. GENERAL: DESIGN IN ACCORDANCE WITH BS 8110-1997, CLASS 3 MEMBER, MEYDAN L.L.C
WITH A MAXIMUM CRACK WIDTH OF 0.2mm. IMPORTANT: P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
ii) FULLY STRESS TENDONS WHEN CONCRETE ATTAINS F'c=22/30 MPa. E: info@dubairacingclub.com W: www.dubairacingclub.com

a) CREEP COEFFICIENT =2.72 FOR 12.7mm DIA. STRANDS (MONO), F'c=25/35MPa. FOR 15.2mm DIA. Principal Consultant:
1. THE FINAL DESIGN & DETAILS OF PT SLABS ARE THE SOLE RESPONSIBILITY OF THE
b) SHRINKAGE STRAIN = 600x10 STRANDS OR 12.7mm DIA. STRANDS (MULTI) CONTRACTOR PT SPECIALIST . HOWEVER , THE FINAL DESIGN AND THE DETAILING
-6
c) YOUNG'S MODULUS OF CONCRETE = 29000 MPa SHALL BE SUBMITTED TO THE ENGINEER AND LOCAL AUTHORITY FOR APPROVAL.
d) ULS DESIGN LOAD SHALL BE = 1.4DL + 1.6LL + EFFECTIVE iii) JACK TENDONS TO 85% U.T.S. AND LOCK OFF.
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
PRESTRESS FORCE www.ae-7.com
iv) JACK CENTRAL TENDONS FIRST AND WORK PROGRESSIVELY OUTWARDS 2. THE CONTRACTOR PT SPECIALIST HAS TO CONSIDER ALL LOADS AND STRAINING Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
4 11-5-3. ALL VERTICAL PROFILES SHALL BE MEASURED FROM THE SLAB TOP LEVEL ON EACH SIDE. (ALTERNATING). ACTION GIVEN IN THE STRUCTURAL DRAWINGS. IN ADDITION TO THE LATERAL P: +971 4 3997758 F: +971 4 3997759

TO THE CENTERLINE OF THE TENDON DUCT EXCEPT AT STRESSING AND REACTIONS THAT SHALL BE EXTRACTED FROM 3D STRUCTURAL MODELS. Sub-Consultant:
DEAD END ANCHORAGES. (SEE NOTE 6 BELOW)
11-17. TENDON POSITION SHALL BE MARKED ON SLAB SOFFIT BY USE OF EMBEDDED
PLASTIC BUTTONS AT GRID AND MID - GRID LOCATIONS AND THE ALIGNMENTS 3. THE MAXIMUM LOND TERM DEFLECTION FOR CANTILIVER SLABS SHALL NOT EXCEED
SHALL BE PAINTED ON SLAB SOFFIT. PROPOSED ARRANGEMENT TO BE L/300 OR 20mm WHICH IS LESSER.
11-6. ANCHORAGES SUBMITTED FOR APPROVAL.

11-6-1. ALL TENDONS SHALL HAVE ANCHORAGES AS SPECIFIED ON THE TENDON 11-18. FINAL STRESSING SHALL FIRST BE APPLIED TO BEAM/BAND TENDONS, FOLLOWED 4. THE MAXIMUM LOND TERM DEFLECTION AT THE MID OF SPAN SHAL NOT EXCEED
LAYOUT DRAWING. THEN BY SLAB TENDONS. Project Name:
L/240 OR 25mm WHICH IS LESSER.

3 11-6-2. ALL ANCHORAGES SHALL BE SET OUT TO THE POSITIONS AND OFFSETS 11-19. ALTERNATIVE STAGED STRESSING OPERATIONS WHERE REQUIRED SHALL DUBAI WATER CANAL
SPECIFIED ON THE TENDON LAYOUT DRAWINGS. BE NOTED. SAFA A
5. THE MAXIMUM INCREMENTAL DEFLECTION SHALL NOT EXCEED L/480.
11-6-3. ALL VERTICAL OFFSETS SHALL BE MEASURED FROM THE SLAB TOP LEVEL TO 11-20. STRAND EXTENSIONS SHALL BE RECORDED FOLLOWING FINAL STRESSING FOR DUBAI-UAE
THE CENTERLINE OF THE ANCHORAGE. SUBMISSION TO THE ENGINEER.
6. THE PT SPECIALIST SHALL COORDINADE WITH THE ENGINEER TO CONSIDER Project Description:
11-7. DUCTS 11-21. FOLLOWING APPROVAL OF THE EXTENSIONS BY THE ENGINEER, STRAND ENDS NON-PRESTRESSING REINFORCEMENT REQUIRED DUE TO LATERAL LOADS
SHALL BE CUT OFF AND SEALED FLUSH WITH THE SURROUNDING CONCRETE "SEISMIC & WIND" AND THERMAL EFFECT AS WELL. MIXED USE DEVELOPMENT
FACE WITH A HOMOGENEOUS CEMENT MIX.
11-7-1. ALL DUCTS SHALL BE CORRUGATED STEEL WITH A MINIMUM WALL THICKNESS (RETAIL & RESIDENTIAL)
OF 0.25 mm. DUCTS SHALL BE RIGIDLY SUPPORTED BY AN APPROVED MEANS
AT NOT MORE THAN 1000 mm CENTERS. NO RIBBED HIGH GRADE BARS SHALL 11-22. GROUTING OF TENDONS SHALL OCCUR WITHIN 7 DAYS OF STRESSING PLOT 02 / 3435336
2 BE PERMITTED TO BE USED AS SUPPORTS. DUCTS SHALL BE SEALED. APPROVAL. BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
Drawing Title:

STRUCTURAL GENERAL NOTES - 04

Scale Drawn Checked Approved Size


AA MA NS
1 N.T.S A1
26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-02-02-00-SG0005 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11
C
L END SUPPORT C
L INTERMEDIATE SUPPORT C
L INTERMEDIATE SUPPORT C
L END SUPPORT

1/3 x L3 OR 1.25 L4
WHICHEVER IS GREATER
SPAN VARIES SPAN VARIES SPAN VARIES CANTILEVER SPAN VARIES

L1 (CLEAR SPAN) L2 (CLEAR SPAN) L3 (CLEAR SPAN) L4 (CLEAR SPAN)

SIDE BARS SIDE BARS SIDE BARS


TOP BARS (T)
A SIDE BARS
C
L OF SPAN C
L OF SPAN C
L OF SPAN N
----
10 ADD TOP BARS ADD TOP BARS TOP BARS (T) ADD TOP BARS TOP BARS (T) ADD TOP BARS KEY PLAN
35mm. MIN. (ET) (AT) (AT) (AT) TOP BARS (T)
75mm. MAX. 1/3 x L1 LCS 1/3 x L* 1/3 x L* LCS 1/3 x L* 1/3 x L* LTB
GREATER OF { 1/3 x L3
1.25 L4
12 x DIA.
DEPTH

MIN.150mm. LCS LCS LCS

9
BOTTOM BARS (B) BOTTOM BARS (B) BOTTOM BARS (B)

BOTTOM BARS (B)


ADD BOTTOM BARS ADD BOTTOM BARS ADD BOTTOM BARS
(AB)
1/8 x L1 50mm. 50mm. 1/8 x L2
(AB)
1/8 x L2 50mm. 50mm. 1/8 x L3
(AB)
1/8 x L3 50mm. 50mm.
General Notes:
50mm. 1/8 x L1
1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
END STIRRUPS OVER END STIRRUPS OVER END STIRRUPS OVER END STIRRUPS OVER END STIRRUPS OVER END STIRRUPS OVER BY THE ENGINEER.
SUPPORT 1/4 L1 MIN. U.N.O. STIRRUPS BALANCE 1/4 L1 MIN. U.N.O. SUPPORT 1/4 L2 MIN. U.N.O. STIRRUPS BALANCE 1/4 L2 MIN. U.N.O. SUPPORT 1/4 L3 MIN. U.N.O. STIRRUPS BALANCE 1/4 L3 MIN. U.N.O. SUPPORT END STIRRUPS
WIDETH (S1) (S2) (S1) WIDETH (S1) S2) (S1) WIDETH (S1) (S2) (S1) WIDETH (S1) 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.
TYPICAL END BAY TYPICAL INTERNAL BAY TYPICAL INTERNAL BAY ADJACENT TO CANTILEVER TYPICAL CANTILEVER

01 TYPICAL
SCALE:
GRAVITY RC. BEAM ELEVATION
N.T.S

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


AUTHORITY APPROVAL 0 08.08.2017 NS
Purpose of Issue Rev. Date Appoved

C C 2 LEGS 3 LEGS 4 LEGS 5 LEGS 6 LEGS Client:


L END SUPPORT L END SUPPORT

SPAN VARIES
5
L1 (CLEAR SPAN) MEYDAN L.L.C
03 TYPICAL STIRRUPS ARRANGEMENT P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
SCALE: N.T.S E: info@dubairacingclub.com W: www.dubairacingclub.com
A REINFORCED CONCRETE BEAM NOTES
SIDE BARS Principal Consultant:
TOP BARS (T) ----
C
L OF SPAN
ADD TOP BARS ADD TOP BARS TOP BARS SEE
NOTES: 1 TO 7 ARE TYPICAL FOR ALL BEAMS.
ADD TOP BARS abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
(ET) (AT) SCHEDULE.
35mm. MIN. (ET) www.ae-7.com
75mm. MAX. 1/3 x L1 1/3 x L* R.C. SLAB Hassanicor Building, 6th Floor, Al Barsha 1
ADDITIONAL LAYER IF CLEAR WHERE OCCURS 1.ALL DIMENSIONS ARE IN MILLIMETER, U.N.O.. PO Box 54115 Dubai, UAE
SPACING BETWEEN REBARS OF P: +971 4 3997758 F: +971 4 3997759
4
ANY LAYER EXCEED 50mm Sub-Consultant:
2.L* IS GREATER OF ADJACENT CLEAR SPAN.
12 x DIA.
DEPTH

SEE NOTE 1
SLAB THICKNESS

3.ALL TOP BARS AND BOTTOM BARS SHALL BE PLACED IN ONE LAYER
IF SPACING PERMITS.SEE TYPICAL BEAM SECTION FOR BAR SPACING
REQUIREMENTS.
T

4.PLACEMENT OF CONTINUOUS AND DISCONTINUOUS REBARS IN EACH

SEE SCHEDULE
LAYER SHALL BE IN ACCORDANCE WITH ACI 318-11M Project Name:

DEPTH
50mm. 1/8 x L1 BOTTOM BARS (B) 1/8 x L1 50mm.
SIDE BAR RECOMMENDATIONS.
3
STIRRUPS,SEE
SCHEDULE
WHERE OCCURS DUBAI WATER CANAL
5.USE END SPACING OF SHEAR REINFORCEMENT FOR ENTIRE
40mm CLEAR
CANTILEVER SPAN.
SAFA A
ADDITIONAL LAYER IF CLEAR TYP.
ADD BOTTOM BARS DUBAI-UAE
SPACING BETWEEN REBARS OF
(AB)
END STIRRUPS OVER END STIRRUPS OVER ANY LAYER EXCEED 50mm 6.WHERE GRAVITY FRAMING INTERSECTS WITH FRAME BEAMS, THE
SUPPORT 1/4 L1 MIN. U.N.O. STIRRUPS BALANCE 1/4 L1 MIN. U.N.O. SUPPORT FRAME BEAM REBAR TAKES PRECEDENCE (i.e. LOCATE IN FIRST OR
MIN. CLEAR HORIZONTAL SPACE

Project Description:
WIDETH (S1) (S2) (S1) WIDETH OUTERMOST LAYERS) U.N.O.. WHERE GRAVITY FRAMING INTERSECTS
BETWEEN BARS IS 25mm

BOTTOM BARS,
WIDTH SEE SCHEDULE SEE SCHEDULE.
OTHER GRAVITY FRAMING, THE DEEPER MEMBER REBAR TAKES MIXED USE DEVELOPMENT
PRECEDENCE OR WHERE BEAMS ARE THE SAME DEPTH,THE BEAM
WITH THE GREATEST REBAR TAKES PRECEDENCE(U.N.O.). (RETAIL & RESIDENTIAL)
PLOT 02 / 3435336
2 7.WHERE TOP REINFORCING VARIES IN ADJACENT SPANS USE THE BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
GREATER VOLUME OF REINFORCING IN BOTH SPANS.
Drawing Title:
8.SEE PLANS FOR ADD'L BEAM REINFORCEMENT NOT SHOWN ON
SCHEDULE.
STRUCTURAL GENERAL DETAILS -
NOTE:
9.STIRRUP ARRANGEMENT TO BE BASED ON EXAMPLES SHOWN ON
THIS SHEET.
01
ADD TOP BARS OUTSIDE STIRRUP CAGE WHERE 10. UPTURNED BEAMS MUST BE PLACED MONOLITHICALLY FOR FULL
NOTES IN REMARKS COLUMN IN BEAM SCHEDULE. Scale Drawn Checked Approved Size
DEPTH OF BEAMS. COLUMNS SUPPORTING UPTURNED BEAMS MUST AA MA NS
1 BE POURED MONOLITHICALLY WITH BEAMS FOR FULL DEPTH OF BEAM. N.T.S A1
26.05.2016 24.08.2017 24.08.2017

02 TYPICAL GRAVITY RC SIMPLE BEAM ELEVATION 11. ADDITIONAL TOP AND BOTTOM BARS SHALL BE PLACED IN SAME
04 TYPICAL BEAM SECTION (A) Drawing Number Rev.
SCALE: N.T.S LAYER AS TOP OR BOTTOM BARS,WHERE POSSIBE.
SCALE: N.T.S 14011603-02-02-00-SG0006 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

WALL REINFORCEMENT PER


REINFORCING PLAN N
10 KEY PLAN
BEAM STIRRUP BEAM STIRRUP
.50 TOP BAR PER SCHEDULE
50.
MAX. OF Ld AND D
50.

A
---

D
9 Ld
HORIZONTAL BARS
HORIZONTAL REINFORCEMENT
BOTTOM BAR PER BEAM SCHEDULE

General Notes:
1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

A SECTION
SCALE:
(A)
N.T.S
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

01 LINTEL
SCALE:
BEAM TYPICAL DETAILS
N.T.S

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


AUTHORITY APPROVAL 0 08.08.2017 NS
Purpose of Issue Rev. Date Appoved
Client:

5
CL MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:

WALL REINFORCEMENT
REINF. TO MATCH SLAB BEAM TOP REINFORCEMENT PER REINFORCING PLAN abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com
DISTRIBUTION REINF. BEAM SIDE BAR PER PER BEAM SCHEDULE Hassanicor Building, 6th Floor, Al Barsha 1
STD. HOOK BEAM SCHEDULE PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4 0.3L OR 1200 MIN. TYPICAL, U.N.O.
50mm MAX. Sub-Consultant:
R.C. SLAB

CONT. SLAB BOTTOM


REINF. PER PLANS
SLAB DISTRIBUTION REINF.
Project Name:
END SUPPORT BEAM BOTTOM REINF.PER
3
BEAM SCHEDULE DUBAI WATER CANAL
SAFA A
DUBAI-UAE

Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
PLOT 02 / 3435336
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
Drawing Title:

STRUCTURAL GENERAL DETAILS -


02
03 ONE
SCALE:
WAY SLAB - TYP. SECTION AT END SUPPORTS: WALLS, GIRDERS, AND BEAMS, U.N.O.
N.T.S
02 TYPICAL
SCALE:
GRAVITY BEAM TO WALL CONNECTION DETAIL
N.T.S Scale Drawn Checked Approved Size
AA MA NS
1 N.T.S A1
26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-02-02-00-SG0007 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

B
DUBAI MUNICIPALITY STAMP:
--- D
---
11
0.25 L1 0.5 L1 0.25 L1

BEAM 2
INDICATESPRIMARY

BEAM 2
BEAM1 ORIENTATION

0.5h

h
A N

0.5h
10 ---
KEY PLAN
C
--- LI
BEAM 1 BEAM 1 TYPICAL INTERNAL SPAN

BEAM 1 - PRIMARY BEAM


BEAM 2 - SECONDARY BEAM BEAM 1 - PRIMARY BEAM
BEAM 2 - SECONDARY BEAM
9

NOTE: General Notes:


WHERE REFT IS TO BE DETAILED CONTINUOUSLY 1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


LAPS IN REFT MAY OCCUR ONLY IN SHADED AREAS SHOWN NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
PRIMARY BEAM DEEPER THAN BY THE ENGINEER.

SECONDARY BEAM PRIMARY & SECONDARY BEAMS OF 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 SAME DEPTH AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

01 BEAM
SCALE:
INTERSECTION (NO COLUMN SUPPORT)
N.T.S 02 BEAM
SCALE:
LAP LOCATIONS
N.T.S

SECONDARY BEAM REFT. - T2 SECONDARY BEAM REFT. - T2 LAP LAP

PRIMARY BEAM REFT. - T1 PRIMARY BEAM REFT. - T1

6
3000

LAP 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


AUTHORITY APPROVAL 0 08.08.2017 NS
Purpose of Issue Rev. Date Appoved
Client:

PRIMARY BEAM REFT. PRIMARY BEAM REFT. -B1


5 SPLICE BAR FOR SECONDARY BEAM-B2
SECONDARY BEAM REFT. MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:

A SECTION
SCALE:
(A)
N.T.S
C SECTION
SCALE:
(C)
N.T.S 03 DETAIL
SCALE:
AT STEP IN BEAM GRATER THAN 100mm.
N.T.S abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
Sub-Consultant:

PRIMARY BEAM REFT. - T1

PRIMARY BEAM REFT. - T1 SECONDARY BEAM REFT. - T2


Project Name:

SECONDARY BEAM REFT. - T2


3
DUBAI WATER CANAL
SAFA A
DUBAI-UAE

Project Description:

MIXED USE DEVELOPMENT


300 min. 300 min. (RETAIL & RESIDENTIAL)
300 min. 300 min. PLOT 02 / 3435336
2 SECONDARY BEAM REFT. - B1 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
SECONDARY BEAM REFT.
SPLICE BAR FOR SECONDARY BEAM - B2 Drawing Title:

PRIMARY BEAM REFT. PRIMARY BEAM REFT. - B1 STRUCTURAL GENERAL DETAILS -


03

Scale Drawn Checked Approved Size


AA MA NS
1 N.T.S A1
B SECTION
SCALE:
(B)
N.T.S D SECTION
SCALE:
(D)
N.T.S
26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-02-02-00-SG0008 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

GRID GRID
N
10 KEY PLAN
CL OF COL. CL OF COL.
175 mm MAX TO COLUMN HOOK AT BEAM 175 mm MAX TO COLUMN HOOK AT BEAM
100 mm MAX TO COLUMN HOOK AT SLAB 100 mm MAX TO COLUMN HOOK AT SLAB

STD. HOOK AT STD. HOOK AT


TOP OF COLUMN TOP OF COLUMN T.O. SLAB
T.O. SLAB EL. SEE PLAN
EL. SEE PLAN
SPACING

SPACING
9 50 MAXIMUM BELOW THE 50 MAXIMUM BELOW THE
= S1

= S1
S1

S1
TIE

TIE
LOWEST HORIZ. REINFORCEMENT LOWEST HORIZ. REINFORCEMENT
"A"

"A"
OF ROOF OR FLOOR SLAB, TYP. OF ROOF OR FLOOR SLAB, TYP.

General Notes:
TIE SPACING = S2

TIE SPACING = S2
1. DO NOT SCALE FROM THIS DRAWING.
S2

S2
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
"H"

"H"
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.
TYP., U.N.O.

TYP., U.N.O.
LAP SPLICE

LAP SPLICE
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
LCS

LCS
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
SPACING

SPACING
AND RELEVANT SECTIONS OF THE SPECIFICATION.
S1

S1
= S1

= S1
TIE

TIE
"A"

"A"
T.O. SLAB T.O. SLAB
EL. SEE PLAN EL. SEE PLAN
SPACING

SPACING
S1/2

S1/2
= S1

= S1
TIE

TIE
SPACING

SPACING
FLOOR SLAB OR R.C. BEAM, TYP.
FLOOR SLAB OR R.C. BEAM, TYP.
S1

S1
= S1

= S1
TIE

TIE

1705
"A"

"A"
7

ONE EXTRA SET OF ONE EXTRA SET OF


TIES AT BAR CRANK TIES AT BAR CRANK
TIE SPACING = S2

TIE SPACING = S2
S2

S2
"H"

"H"
6
SPACING

SPACING
S1

S1
= S1

= S1
TIE

TIE

1705
"A"

"A"
T.O. SLAB T.O. SLAB 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
EL. SEE PLAN EL. SEE PLAN
AUTHORITY APPROVAL 0 08.08.2017 NS
SPACING

SPACING
S1/2

S1/2
Purpose of Issue Rev. Date Appoved
= S1

= S1
TIE

TIE Client:
SPACING

FLOOR SLAB OR R.C. BEAM, TYP. FLOOR SLAB OR R.C. BEAM, TYP.
SPACING
TIE "A"
S1

S1
= S1
TIE

= S1
"A"

5
MEYDAN L.L.C
ONE EXTRA SET OF ONE EXTRA SET OF P.O. Box 9305, Dubai , UAE.
TIES AT BAR CRANK TIES AT BAR CRANK T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com
TIE SPACING = S2

TIE SPACING = S2
S1

S2
Principal Consultant:
"H"

"H"

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


www.ae-7.com

DOWELS TO MATCH COLUMN DOWELS TO MATCH COLUMN Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
VERTICAL REINF. VERTICAL REINF. P: +971 4 3997758 F: +971 4 3997759
4
SPACING

SPACING

Sub-Consultant:
S1

TIE "A"
= S1

S1
TIE

LCS
= S1

LCS
"A"

LAP SPLICE T.O. PILE CAP OR FOOTING LAP SPLICE T.O. PILE CAP
TYP., U.N.O. EL. SEE PLAN TYP., U.N.O. EL. SEE PLAN
KICKER

KICKER
75mm.

75mm.
FOOTING DEPTH

FOOTING DEPTH
Project Name:

3
DUBAI WATER CANAL
SAFA A
DUBAI-UAE

Project Description:
NOTES: MIXED USE DEVELOPMENT
(RETAIL & RESIDENTIAL)
PLOT 02 / 3435336
1. "A" SHALL NOT BE LESS THAN "H/6" AND THE MAXIMUM
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
COLUMN DIMENSION (WIDTH, DEPTH OR DIAMETER).
Drawing Title:

2. INTERNAL CROSS TIE SIZES AND SPACING SHALL STRUCTURAL GENERAL DETAILS -
04
04 TYPICAL ROUND IMRF CONCRETE COLUMN 02 TYPICAL
SCALE:
RECTANGULAR / SQUARE IMRF COLUMN ELEVATION
N.T.S
MATCH PERIMETER TIE SIZES AND SPACING.
SCALE: N.T.S
3. "S2" SPACING IS LISTED IN COLUMN SCHEDULE. "S1" Scale Drawn Checked Approved Size
AA MA NS
1 N.T.S A1
EQUALS ONE HALF OF "S2". 26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-02-02-00-SG0009 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


COLUMN COLUMN COLUMN

DOWELS SIZE & NUMBER


11 TO MATCH LARGER OF
UPPER AND LOWER COLUMN
ADD DOWELS IF AREA
OF REINF. IN COLUMN SEE (1) WHEN OFFSET LESS
ABOVE IS LARGER THAN 75mm MAX. SEE 3B WHEN THAN 75mm
COLUMN BELOW. OFFSET LARGER THAN 75mm 0mm

ADD DOWELS IF AREA OF


REINF.

SEE COL.
KICKER S (TYP.)

SEE COL.
SEE COL.

S (TYP.)
KICKER S (TYP.)

SCHD.

SCHD.
SCHD.
IN COLUMN ABOVE IS LARGER

LAP

LAP
LAP

75
FLOOR SLAB THAN COLUMN BELOW. N
10 KEY PLAN

75

50
75

50

50
50

6 MAX. BEND BARS INTO

S MAX.
SLAB/BEAM

SEE COL.
SEE COL.

SEE COL.
SCHD.
SCHD.
1

SCHD.
LAP
LAP
150mm

LAP
MAX.

S (TYP.)

S (TYP.)
9

ADDITIONAL 2 TIES AT BOTTOM OF BEND


BEND General Notes:
MAX. SPACING 150
1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


COLUMN NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
COLUMN COLUMN
BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

01 COLUMN
SCALE:
IS OFFSET BY LESS THAN 75
N.T.S 02 COLUMN ABOVE IS SMALLER THAN COLUMN BELOW
03 COLUMN SIZE ABOVE IS LARGER THAN COLUMN BELOW 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
SCALE: N.T.S SCALE: N.T.S AND RELEVANT SECTIONS OF THE SPECIFICATION.

TYPICAL DETAIL OF VERTICAL COLUMN


7
REINFORCEMENT

6
LAP

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


COLUMN CONSTRUCTION JOINT AUTHORITY APPROVAL 0 08.08.2017 NS
Purpose of Issue Rev. Date Appoved
Client:
SLAB

TYPICAL SPANNING "S1"

5 Ta Ta
MEYDAN L.L.C
PROVIDE TIES AT

P.O. Box 9305, Dubai , UAE.


T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

TYPICAL SPANNING "S1"

TYPICAL SPANNING "S1"


Principal Consultant:

PLACE THIS PART OF CONC.

75mm KICKER

75mm KICKER
STARTER BARS

PROVIDE TIES AT

PROVIDE TIES AT
D

LAP

LAP
COLUMN MONOLITHICALLY (PROVIDE FULL
WITH
2

TENSION ANCHORAGE)
1/

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


BEAM & SLAB. CONCRETE www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
STRENGTH TO BE GREATEST PO Box 54115 Dubai, UAE
4 OF DOWELS SAME AS P: +971 4 3997758 F: +971 4 3997759

BEAM, SLAB OR COLUMN


CJ COLUMN REINF. Sub-Consultant:
2

2
1/

1/
(PROVIDE FULL
COLUMN CONSTRUCTION JOINT TENSION ANCHORAGE)

Project Name:

3
DUBAI WATER CANAL
COLUMN
SAFA A
DUBAI-UAE

Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
PLOT 02 / 3435336
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
Drawing Title:

STRUCTURAL GENERAL DETAILS -


TYPICAL DETAIL OF COLUMN AT INTERNAL COLUMN TERMINATION DETAIL 05
04 UPSET BEAM OR STEP IN FRAMED SLAB 05 WHERE COLUMN STOPS AT FLOOR LEVEL
06 COLUMN SUPPORTED ON WALL 06 PLANTED COLUMN SUPPORTED ON SLAB
SCALE: N.T.S SCALE: N.T.S
Scale Drawn Checked Approved Size
SCALE: N.T.S SCALE: N.T.S AA MA NS
1 N.T.S A1
26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-02-02-00-SG0010 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


X X H
11 SEE NOTE 1
X X X X

SEE NOTE 1 SEE NOTE 1

B
N
10 KEY PLAN

8 BARS 10 BARS
4 BARS 6 BARS 03 04 SCALE: N.T.S

01 02 CONDUITS PLACEMENT IN COLUMNS


SCALE: N.T.S

11
SCALE: N.T.S SCALE: N.T.S
SCALE: N.T.S

9
CONDUITS PLACEMENT TO CONFORM TO THE REQUIREMENTS OF
X X X X X UBC1997 AND: THE TOTAL AREA OF EMBEDDED CONDUITS SHALL NOT
X X
SEE NOTE 1 EXCEED 1% OF THE CROSS AREA (B x H) CONDUITS TO BE SECURED General Notes:
1. DO NOT SCALE FROM THIS DRAWING.
TO COLUMN TIES
. 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

SEE NOTE 1 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES

X
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

X
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

14 OR 16 BARS
12 BARS 06 SCALE: 24 BARS
07
N.T.S

05 SCALE: N.T.S SCALE: N.T.S

250 MAX.

6
P
LA

SEE NOTE 1
100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
AUTHORITY APPROVAL 0 08.08.2017 NS
Purpose of Issue Rev. Date Appoved
Client:

5
X

MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
X

T: +9714 3270000 F: +9714 3270007


E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:

ROUND COLUMN NARROW COLUMNS L SHAPED COLUMN


08 SCALE: N.T.S 09 SCALE: N.T.S 10 SCALE: N.T.S

NOTES:
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
1. TYPICAL DETAILS TO BE READ IN CONJUNCTION WITH Sub-Consultant:

COLUMN SCHEDULE.
2. FOR LAP LENGTHS AND REFER GENERAL NOTES #
00-S015.
Project Name:
3. TIE VERTICAL BARS WITH LINKS SHOWN DASHED WHEN DUBAI WATER CANAL
3 DIST. 'X' IS GREATER THAN 150mm. SAFA A
DUBAI-UAE
4. CLEAR DISTANCE BETWEEN VERTICAL BARS SHALL BE
NOT LESS: Project Description:

MIXED USE DEVELOPMENT


a) 1.40 TIMES VERTICAL BAR DIAMETER. (RETAIL & RESIDENTIAL)
b) 1.40 TIMES THE MAX. SIZE OF THE COARSE PLOT 02 / 3435336
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
AGGREGATE.
c) 40mm Drawing Title:

STRUCTURAL GENERAL DETAILS -


5. REFER COLUMN SCHEDULE FOR REINFORCEMENT 06
ARRANGEMENTS NOT SHOWN HERE.
6. PROVIDE FULL TIE FOR EVERY OTHER VERTICAL BAR. Scale Drawn
AA
Checked
MA
Approved
NS
Size

1
TYPICAL SECTIONAL N.T.S
26.05.2016 24.08.2017 24.08.2017
A1
7. ALTERNATIVE BAR ARRANGEMENT, MAY BE USED IF
REINFORCEMENT LAYOUT IN COLUMNS APPROVED BY THE CONSULTANT.
Drawing Number

14011603-02-02-00-SG0011
Rev.

0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


2N16
11
FOR SLAB DETAILS FOR SLAB DETAILS
REFER TO LAYOUTS REFER TO LAYOUTS FOR SLAB DETAILS FOR SLAB DETAILS
REFER TO LAYOUTS REFER TO LAYOUTS

LAP

LAP
N
10 KEY PLAN
LAP

LAP
9

General Notes:
1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

01 TYPICAL DETAILS AT TOP OF WALLS


02 TYPICAL WALL/SLAB JUNCTION DETAILS 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 SCALE: N.T.S SCALE: N.T.S AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

'U' BARS
AS PER SCHEDULE
7 LAP
PLACE VERTICAL
BARS IN CORNER LAP

TYPICAL

6
LAP

LAP

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


'U' BARS AUTHORITY APPROVAL 0 08.08.2017 NS

'U' BARS AS PER SCHEDULE Purpose of Issue Rev. Date Appoved

T12-300
Client:

AS PER SCHEDULE
'U' BARS
5
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
'U' BARS Sub-Consultant:

LAP AS PER SCHEDULE


'U' BARS 'U' BARS
AS PER SCHEDULE AS PER SCHEDULE VL. RFT (E.F.)
Project Name:
AS PER SCHEDULE & DETAILS
LAP

LAP

3
DUBAI WATER CANAL
SAFA A
DUBAI-UAE

HL. RFT (E.F.) Project Description:


AS PER SCHEDULE & DETAILS MIXED USE DEVELOPMENT
LAP

(RETAIL & RESIDENTIAL)


PLOT 02 / 3435336
2 'U' BARS BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
AS PER SCHEDULE LINK / STIRRUPS
TIES AS PER AS PER SCHEDULE
Drawing Title:

SCHEDULE STRUCTURAL GENERAL DETAILS -


07

Scale Drawn Checked Approved Size


AA MA NS
1 N.T.S A1
26.05.2016 24.08.2017 24.08.2017

03 TYPICAL WALL PLAN JUNCTION DETAILS 04 TYPICAL WALL SECTION Drawing Number Rev.

SCALE: N.T.S SCALE: N.T.S 14011603-02-02-00-SG0012 0


All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

SHEAR WALL SHEAR WALL DUBAI MUNICIPALITY STAMP:


SEE PLANS
OUTSIDE CORE INSIDE CORE
11

SEE SHEAR WALL DETAILS


FOR WALL REINFORCEMENT
SHEAR WALL
OUTSIDE CORE BEYOND INSIDE CORE 30 CLEAR COVER
SEE SCHEDULE FOR INTENTIONALLY TO WALLS
WALL RFT. ROUGHENED SURFACE
N
10 INTENTIONALLY COG BAR IF SLAB KEY PLAN
DOWEL BARS TO ROUGHENED SURFACE NOT CONTINUOUS
36

50
MATCH SLAB REINF'T. 36 TYP
TYP. . 36 FOR SLAB REINFORCEMENT
TYP DOWEL BARS TO SEE PLAN
SLAB RFT SLAB REINF.'T . MATCH SLAB REINF'T.
50

TYP.
1.3Ld+400(MIN.) SEE DETAIL SEE PLANS

50
SLAB RFT 1.3Ld+400(MIN.) SLAB REINF.'T
SEE PLANS SEE PLANS
9 T12

1.3Ld (MIN.)
General Notes:
1.3Ld (MIN.) 45MM
CONTINUOUS 1. DO NOT SCALE FROM THIS DRAWING.
DOWEL BARS TO SEAT

50
ALL SLAB REINF'T. TO MATCH SLAB REINF'T. ALL SLAB REINF'T. TO HOOK AT 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
HOOK AT FAR SIDE OF FAR SIDE OF BEAM BY THE ENGINEER.
TYP.

WALL
50

75 (TYP.) 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 CLEAR COVER AT SITE.
SEE SCHEDULE FOR
50 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
BEAM REINFORCING ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
CORK FILLING STRIP AND RELEVANT SECTIONS OF THE SPECIFICATION.

75 OR APP'D EQUIV.
(TYP.)

01 TYPICAL
SCALE:
SLAB/COREWALL CONNECTION
N.T.S 03 TYPICAL
SCALE:
LINTEL BEAM/SLAB CONNECTION
N.T.S
05 TYPICAL
SCALE:
SLAB SEAT AT SHEARWALL
N.T.S

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


SHEAR WALL SHEAR WALL AUTHORITY APPROVAL 0 08.08.2017 NS
SEE PLANS Purpose of Issue Rev. Date Appoved
OUTSIDE CORE INSIDE CORE
Client:

5 SEE SHEAR WALL DETAILS


MEYDAN L.L.C
SHEAR WALL FOR WALL REINFORCEMENT P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com
OUTSIDE CORE BEYOND INSIDE CORE
Principal Consultant:
SEE SCHEDULE FOR INTENTIONALLY SURFACE INTENTIONALLY
WALL REINF'T. ROUGHENED SURFACE ROUGHENED
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
INTENTIONALLY FOR SLAB REINFORCEMENT
www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
DOWEL BARS TO ROUGHENED SURFACE PO Box 54115 Dubai, UAE
4 MATCH SLAB REINF'T. SEE PLAN P: +971 4 3997758 F: +971 4 3997759
36 Sub-Consultant:
TYP. 36 36
SLAB RFT 1.3Ld+400(MIN.) 50 SLAB RFT TYP TYP
. . DOWEL BARS TO
TYP.

SEE PLANS SEE DETAIL


50

MATCH SLAB REINF'T.

SEE LINTEL BEAM SCHEDULE Project Name:


1.3Ld (MIN.) FOR REINFORCEMENT DUBAI WATER CANAL
3 SLAB REINF.'T
1.3Ld+400(MIN.) SEE PLANS SAFA A
1.3Ld (MIN.)
DUBAI-UAE
ALL SLAB REINF'T. TO ALL SLAB REINF'T. TO HOOK
TYP.
50

HOOK AT FAR SIDE OF SLAB REINF.'T AT FAR SIDE OF BEAM Project Description:
50 75 (TYP.) WALL SEE PLANS MIXED USE DEVELOPMENT
CLEAR COVER SEE SCHEDULE FOR (RETAIL & RESIDENTIAL)
BEAM REINFORCING PLOT 02 / 3435336
75
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
(TYP.)
Drawing Title:

STRUCTURAL GENERAL DETAILS -


08

Scale Drawn Checked Approved Size


AA MA NS
1 N.T.S A1

02 TYPICAL SLAB/COREWALL CONNECTION 04 TYPICAL


SCALE:
LINTEL BEAM/SLAB CONNECTION
N.T.S
06 LINTEL
SCALE:
BEAM DETAIL
N.T.S
26.05.2016 24.08.2017 24.08.2017
SCALE: N.T.S Drawing Number Rev.

14011603-02-02-00-SG0013 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

MIN. CLEARANCE WHERE NO LINK BEAM DUBAI MUNICIPALITY STAMP:


BETWEEN SLEEVES OCCURS ABOVE RECTANGULAR
11 OPENING ADD BARS TO
IS THE LARGER
DIAMETER 'D' MATCH CUT VERT. REINF.
NUMBER ADDED BARS AT EACH
D D
U BAR TO MATCH VERT. FACE TO EQUAL HALF U BAR TO MATCH
600 600 HORIZONTAL OR VERTICAL NUMBER OF CUT BARS PLUS 1 HORIZONTAL OR VERTICAL
TRIM BARS TO
MAX. MAX. REINFORCEMENT. REINFORCEMENT.
MATCH WALL N
10
HORIZONTAL BARS
KEY PLAN
CL (1)-T16 E.F. MIN.

FOR D>=450
ADD (1)-T16
x1.8m E.F.
9
FOR WALLS
300 & THICKER NOTES:
General Notes:
TRIM BARS.
CLASS 'B' SPLICE 1. LENGTH OF TRIM 1. DO NOT SCALE FROM THIS DRAWING.
TRIM BARS TO 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
BARS = D+1200 NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
MATCH WALL BY THE ENGINEER.
'W'
VERTICAL BARS 2. OMIT TRIM BARS 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
8 EQ. EQ. SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
AT SITE.
(1)-T16 E.F. MIN. FOR SINGLE
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
OPENINGS AND RELEVANT SECTIONS OF THE SPECIFICATION.

A SECTION (A) WHEN D<150


01 CIRCULAR
SCALE:
OPENING
N.T.S
SCALE: N.T.S

7
TENSION
ADD (2)-T16 SPLICE SPLICE SHEAR WALL

B
----
A
----

LENGTH LENGTH
x1800 E.F. WIDTH
TYP. FOR WALLS
300 & THICKER T12 STIRRUPS AT 100mm
ONE PIECE OR 2 PIECE
6 A CLOSED STIRRUP UNO 4T20 U.N.O
---- (2)-T16 FOR 900mm
OPEN WIDE OR SMALLER T.O.S 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
OPENINGS AUTHORITY APPROVAL 0 08.08.2017 NS
Purpose of Issue Rev. Date Appoved
(2)-T20 FOR WIDER
TYP.
600

Client:
OPENINGS EXCEPT
H

AS NOTED.
5
'W'=2100mm MAX. MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
30

H
T: +9714 3270000 F: +9714 3270007
'W' 600 T12 STIRRUPS E: info@dubairacingclub.com W: www.dubairacingclub.com
SHEAR WALL RFT. CL Principal Consultant:
TYP. SEE DETAILS, TYP.

4T20 U.N.O T12 AT 100 E.F. U.N.O abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com

02 RECTANGULAR OR SQUARE OPENING Hassanicor Building, 6th Floor, Al Barsha 1


PO Box 54115 Dubai, UAE
SCALE: N.T.S P: +971 4 3997758 F: +971 4 3997759
4
CONT SHEAR WALL Sub-Consultant:
TOP OF OPENING RFT. SEE DETAILS
(2)-T16 FOR 900mm T12 AT 100mm E.F. U.N.O 4T20 U.N.O
A
----

WIDE OR SMALLER
OPENINGS BEND WHERE VERTICAL
SHEAR WALL RFT. BARS BEYOND
(2)-T20 FOR WIDER ADJACENT Project Name:
SEE DETAILS, TYP.
3 OPENINGS EXCEPT OPENING HOOK HORIZONTAL
DUBAI WATER CANAL
Ld

Ld SAFA A
AS NOTED. INTERFERES T10 TIES AT 150mm BARS AT OPENING
FULL HEIGHT OF DUBAI-UAE
'W'=2100mm MAX. OPENING
(2)-T16 FOR 900mm B SECTION (B) Project Description:
DOWELS INTO
WIDE OR SMALLER
SCALE: N.T.S MIXED USE DEVELOPMENT
A SLAB OR FOOTING (RETAIL & RESIDENTIAL)
---- OPENINGS PLOT 02 / 3435336
2 OPEN (2)-T20 FOR WIDER BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
LENGTH
SPLICE

NOTE
L1

CLASS 'B' OPENINGS EXCEPT Drawing Title:

PLACE BARS IN AS NOTED.


SPLICE STRUCTURAL GENERAL DETAILS -
SAME PLANE 'W'=2100mm MAX.
09
L2

FOR WALLS L2=Ld


ADD. RFT. AS TYP. CONC.
200 OR LESS. SLAB OPENING DETAIL, Scale Drawn
AA
Checked Approved
NS
Size
MA
1 'W' N.T.S
26.05.2016 24.08.2017 24.08.2017
A1
BEND IF
04 TYPICAL SHEAR WALL BEAM DETAIL Drawing Number Rev.

03 DOOR
SCALE:
OPENING
N.T.S
NECESSARY SCALE: N.T.S
14011603-02-02-00-SG0014 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

CL OF BEAM CL OF BEAM CL OF BEAM CL OF BEAM


DUBAI MUNICIPALITY STAMP:
TEMPERATURE REINF. TEMPERATURE REINF. TEMPERATURE REINF.
WHERE REQUIRED WHERE REQUIRED WHERE REQUIRED
11 (SEE NOTE #3) (SEE NOTE #3) (SEE NOTE #3)

SLAB THICKNESS

SLAB THICKNESS

SLAB THICKNESS
1/4 L1 1/3 L 1/3 L 1/3 L 1/3 L GREATER OF (1/4 L3, 1.5 L4)

PER SCHEDULE

PER SCHEDULE

PER SCHEDULE
TOP LEFT REINF. TOP RIGHT REINF. TOP RIGHT REINF. TOP RIGHT REINF.
OF SPAN #1 OF SPAN #1 OR 'Ld' SPLICE TYPICAL OF SPAN #2 OR OF SPAN #3 OR
TOP LEFT REINF. TOP LEFT REINF. TOP LEFT REINF.
OF SPAN #2 OF SPAN #3 OF SPAN #4

STD. HOOK STD. HOOK N


10 KEY PLAN

BOTTOM REINF. BOTTOM REINF. BOTTOM REINF.


PER SLAB SCHEDULE PER SCHEDULE PER SCHEDULE
DISTRIBUTION REINF. Ldc DISTRIBUTION REINF. Ldc DISTRIBUTION REINF. Ldc DISTRIBUTION REINF.
PER SLAB SCHEDULE PER SLAB SCHEDULE PER SLAB SCHEDULE PER SCHEDULE
(SEE NOTE #1) (SEE NOTE #1) (SEE NOTE #1) (SEE NOTE #1)

9
BEAM CLEAR SPAN - L1 BEAM CLEAR SPAN - L2 BEAM CLEAR SPAN - L3 BEAM CLEAR SPAN - L4

EXTERIOR SPAN #1 EXTERIOR SPAN #2 EXTERIOR SPAN #3 CANT. SPAN #4


(WHERE OCCURS) General Notes:
1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
NOTES: AND RELEVANT SECTIONS OF THE SPECIFICATION.

1. ALL BOTTOM REINFORCEMENT SHALL BE CONTINUOUS WITH CLASS 'A' SPLICE AT SUPPORTS.
01 TYPICAL
SCALE:
SECTION AT ONE WAY GRAVITY SLAB
N.T.S
TOP DISTRIBUTION REBARS ARE ANCHORED IN END SUPPORTS WITH STD. HOOK.
2. SEE CONCRETE NOTES FOR CONCRETE COVERS.
3. PROVIDE TEMPERATURE REINF. TO MATCH SLAB DISTRIBUTION REINF. WHERE TOP OF SLAB IS EXPOSED TO WEATHER.
7
4. L IS GREATER OF ADJACENT SPAN.

CUT BARS
100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS

. AUTHORITY APPROVAL 0 08.08.2017 NS


P PLACE TRIM BARS SAME SIZE AS
.
EQ

Rev.
TY
Purpose of Issue Date Appoved
CUT BARS AT EACH FACE OF OPENING. TRIMMER BARS Client:

P. NUMBER OF TRIM BARS AT EACH FACE


.
EQ

5 TY TO EQUAL HALF OF CUT BARS PLUS 1.


MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:
LAP LAP

1 abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


www.ae-7.com
----
OPEN Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
4 U-BARS OF THE SAME Sub-Consultant:
P: +971 4 3997758 F: +971 4 3997759

DIAMETER
AS THE BARS ON TO WHICH
600
THEY LAP TYPICAL.
TYP.

TYP. ADDITIONAL DIAGONAL REINFORCEMENT


600

T16 x 1200 TOP AND BOTTOM Project Name:

AT EACH CORNER OF ALL OPENINGS DUBAI WATER CANAL


3 A SECTION
SCALE:
(A)
N.T.S SAFA A
DUBAI-UAE

Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
02 TYPICAL SLAB OPENING OVER THAN 150mm PLOT 02 / 3435336
2 SCALE: N.T.S BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
TRIMMING REFT FOR HOLES IN SLABS Drawing Title:

NOTES : 1. ALL REPLACEMENT AND DIAGONAL BARS SHOULD STRUCTURAL GENERAL DETAILS -
EXTEND AN ANCHORAGE LENGTH BEYOND THE 10
1. REINF. SIMILAR FOR CIRCULAR OPENINGS. EDGE OF THE HOLE.
2. FOR OPENINGS LARGER THAN 600mm (ANY SIDE) SEE PLAN FOR TRIM REINF.
2. HOLES LARGER THAN 900 mm IN ANY DIRECTION ARE
Scale Drawn Checked Approved Size
AA MA NS
1 3. OPENINGS LARGER THAN 600mm (ANY SIDE) NOT SHOWN ON STRUCTURAL PLANS N.T.S A1

MUST BE APPROVED BY STRUCTURAL ENGINEER PRIOR TO CONSTRUCTION. DETAILED ON THE DRAWINGS 26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-02-02-00-SG0015 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

MULTIPLE LAYERS OF RFT ARE NUMBERED IN ASCENDING ORDER FROM THE


OUTERMOST LAYER INWARDS AS SHOWN BELOW: Ld
DUBAI MUNICIPALITY STAMP:
T1 T2
11
T 4T20
T&B

T
B1 B2
N
10 KEY PLAN
S = LESS THAN 0.8T 1.5T
01 NOTATION
SCALE:
FOR PLACEMENT OF SLAB REINFORCEMENT
N.T.S
Ld
NOTES:
T1 DENOTES FIRST (OUTERMOST) LAYER OF TOP REFT.
T2 DENOTES SECOND LAYER TOP REFT.
B1 DENOTES FIRST (OUTERMOST) LAYER OF BOTTOM REFT. 05 TYPICAL
SCALE:
SLAB STEP DOWN DETAILS
N.T.S
B2 DENOTES SECOND LAYER OF BOTTOM REFT.
9

ADD 1-T10-400 TOP x 1000


CONSTRUCTION JOINT AT LONG WHEN NO TOP General Notes:
MIDSPAN ONLY REINFORCEMENT IS NOTED Ld
KEY CUT NOTE:
ON PLAN 4T20 1. DO NOT SCALE FROM THIS DRAWING.

CUT KEYS IN SLABS AS FOLLOWS: T&B 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


CL SLAB THICKNESS KEY SIZE SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.
LESS THAN 150 38 x 38
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
150 TO 250

S
38 x 39 ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.
250 TO 350 38 x 140
REFER KEY CUT NOTE 350 & THICKER 38 x 184

T
02 SLAB
SCALE:
CONTROL JOINT
N.T.S
NOTES: SAME SIZE & SPACING
7 AS PER SLAB REINF'T.
1. JOINT LOCATION TO BE APPROVED BY ENGINEER U.N.O. 1.5T
2.EXTEND SLAB REINFORCEMENT THROUGH JOINT FOR THE FULL LENGTH
STIPULATED ON PLAN AND OR TYPICAL DETAILS. Ld
S = GREATER THAN 0.8T
CL LESS THAN 1.5T

6 DOWEL BARS TO
DOWEL BARS TO MATCH SLAB REINF'T.
MATCH SLAB REINF'T.

SLAB TOP BAR


06 TYPICAL
SCALE:
SLAB STEP DOWN DETAILS
N.T.S 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
AUTHORITY APPROVAL 0 08.08.2017 NS
PER SLAB REINF. PLAN
Purpose of Issue Rev. Date Appoved
Client:
FLOOR SLAB LTB LTB CORE WALL SLAB
PER PLAN WHERE OCCURS
5
TENSION LAP MEYDAN L.L.C

75 MAX,.
TENSION LAP
TYP.

P.O. Box 9305, Dubai , UAE.


0

T: +9714 3270000 F: +9714 3270007


E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:
TYP.
0

t
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
SLAB BOTTOM BAR CORE WALL SLAB
www.ae-7.com
TENSION LAP Hassanicor Building, 6th Floor, Al Barsha 1
PER SLAB REINF. PLAN REINF. PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
3t 1.5t Sub-Consultant:

DOWEL BARS TO
MATCH SLAB REINF'T. DOWEL BARS TO MATCH SLAB REINF'T.

03 TYPICAL SLAB- WALL CONNECTION DETAIL 07 TYPICAL SLAB STEP - 75mm MAX. Project Name:

3
SCALE: N.T.S
NOTE: SEE PLANS FOR FURTHER INFORMATION.
SCALE: N.T.S DUBAI WATER CANAL
SAFA A
DUBAI-UAE
WALL
Project Description:
ADDITIONAL 0.25 L 0.5 L 0.25 L
DIAGONAL BARS AT SLAB
MIXED USE DEVELOPMENT
TOP & BOTTOM (RETAIL & RESIDENTIAL)
PLOT 02 / 3435336
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
Drawing Title:
L
STRUCTURAL GENERAL DETAILS -
EDGE BEAM
COLUMN NOTE: 11
ADDITIONAL 1. WHERE REINF'T. IS TO BE DETAILED CONTINUOUSLY LAPS IN
SLAB DIAGONAL BARS Scale Drawn Checked Approved Size
AT TOP & BOTTOM REINF'T. MAY OCCUR ONLY IN SHADED AREAS SHOWN N.T.S
AA MA NS
1 A1
26.05.2016 24.08.2017 24.08.2017

04 CORNER REFT DETAILS 08 LAP LOCATIONS Drawing Number Rev.

SCALE: N.T.S
SCALE: N.T.S 14011603-02-02-00-SG0016 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11 BEAM, SLAB OR STAIR MIX.


200 MAX.

ELECT. DWGS.
CHANNEL GRATING FOR DETAIL ROUGHEN JOINT

SEE MECH./
100 100 125 MIN.

'Ld'
REFER MECHANICAL DWGS. 25 CLR. T12 @ 200 O.C.
MIN. MIN. EACH WAY 25 CLR.

ELECT. DWGS.
SLAB TYP. SLAB

SEE MECH./
a E.F. REBAR REBAR TYP.
SUPPORT TO
HANGER WALL WALL/COLUMN SLAB
(2)T12 CONT. @300 O.C.

MAX.
b E.F. MIX

150
45° 45° EL. SEE PLAN

SLAB

MAX.
450
EL. SEE PLAN
FL. LEV.
N
10 T12 @ 300 O.C. KEY PLAN

Ld (OR LDh WITH

Ld (OR LDh WITH


STD. 90 HOOK)
ALT.

STD. 90 HOOK)
T10-200-EW, EF

01 TYPICAL
SCALE:
DETAILS OF HANGER WALL
N.T.S

TYPICAL JUNCTION DETAILS FOR COLUMNS &

TYP.

TYP.
NOTE:
02 DETAIL
SCALE:
OF DRAIN CHANNEL IN SLABS
N.T.S 03 BEAMS
SCALE:
WITH DIFFERENT GRADE OF CONCRETE
N.T.S
FOR (a) & (b) VALUES REF WALL SCHEDULE IF APPLICABLE
MACHINE BASE POURED MONOLITHIC WITH SLAB CURB WIDTH 200 MAX. 125 MIN.
20DIA. HOLES ON
ANGLE
70
ADDITIONAL BARS GALVANIZED 75x75x6 EA AT 200 CENTRES.
SLAB REINF'T 2T16 TOP & BOTTOM 6DS MIN. D2 LESS THAN 1\3 T
'L' 200 MIN.
T16

T16

70
ROUGHEN JOINT
9 'L' 'L'
W 25 CLR.

ELECT. DWGS.
t

ELECT. DWGS.
T12 @ 200 O.C.

1/3
SLAB

SEE MECH./
TYP.

SEE MECH./
EACH WAY REBAR
25 CLR.

1/3

T
SLAB CLASS 'A' SPLICE ROUGHEN JOINT
1 T12 AT 150 CENTRES

1/3
TYP. (2)T12 CONT. @300 O.C.
t

1 REBAR TYP. General Notes:


T16

D2 LESS THAN 1\3 T


T16

200 200 D1 LESS THAN 1\3 T T12 HOOKED BAR SLAB SLAB

MAX.
MAX.
WELDED TO ANGLE AT

450
EL. SEE PLAN

150
EL. SEE PLAN 1. DO NOT SCALE FROM THIS DRAWING.
500 CENTRES MAX.
SLAB REINF'T NOTE: T12 (L)-BAR AT 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
1. CONDUITS SHALL BE PLACED IN MIDDLE THIRD OF WALL THICKNESS. 150 CENTRES NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
2. DS IS THE LARGER OF D1 OR D2. VALVE PIT COVERS AND TRENCH COVERS T12 @ 300 O.C. BY THE ENGINEER.

Ld (OR LDh WITH


EACH WAY

STD. 90 HOOK)
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
8 TYPICAL RECESS DETAIL FOR SUMP PIT COVERS, SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK

Ld (OR LDh WITH


STD. 90 HOOK)
AT SITE.
06 VALVE PIT COVERS AND TRENCH COVERS

TYP.
04 TYPICAL
SCALE:
SECTION FOR U-CHANNEL OF SLAB
N.T.S 05 CONDUIT
SCALE:
PLACEMENT IN WALLS
N.T.S
SCALE: N.T.S
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS

TYP.
CURB WIDTH 200 MIN. AND RELEVANT SECTIONS OF THE SPECIFICATION.

A393 BRC FABRIC MESH MACHINE BASE POURED AFTER SLAB POUR NOTES:
TOC NOTES:

50
2 x 2-T20 FOR WALLS THICKER THAN 450 1. SEE MECHANICAL, ELECTRICAL, PLUMBING AND ARCHITECTURAL
PER 50 150 1. SEE MECHANICAL, ELECTRICAL, PLUMBING AND ARCHITECTURAL DRAWINGS FOR LOCATION AND DRAWINGS FOR LOCATION AND DIMENSIONS OF MACHINE BASE.
DIMENSIONS OF MACHINE BASE. THE CONTRACTOR SHALL COORDINATE THE PROVISION OF MACHINE THE CONTRACTOR SHALL COORDINATE THE PROVISION OF CURBS
4 SETS OF ADDITIONAL LINKS BASE DOWELS FROM THE SLAB PRIOR TO THE CONCRETING OF THE SLAB. DOWELS FROM THE SLAB PRIOR TO THE CONCRETING OF THE SLAB.
SLEEVES 200 DIA. MAX.
SPEC

HARDCORE
200 MIN.

AS

2. CLEAR COVERS TO BARS SHOWN ARE FOR INTERIOR CONDITIONS. FOR OTHER CONDITIONS
S

2. CLEAR COVERS TO BARS SHOWN ARE FOR INTERIOR CONDITIONS. FOR OTHER CONDITIONS
7 SEE CONCRETE NOTES.
900 MIN. 400 900 MIN SUB-GRADE
MIN
WATERPROOFING IF REQUIRED
REFER TO STRUCTURAL DRAWINGS FOR REINFORCEMENT
AT SLEEVES GREATER THAN 200 DIA. 50mm BLINDING
1000 GAUGE POLYTHENE SHEET

07 REINFORCEMENT
SCALE: N.T.S
AT SLEEVES THROUGH WALLS 08 TYPICAL
SCALE:
DETAILS OF GRADE SLAB (150mm)THICKNESS
N.T.S 15 TYPICAL
SCALE:
MACHINE BASE REINFORCING AT SLAB
N.T.S 16 TYPICAL
SCALE:
CONCRETE CURB REINFORCING AT SLAB
N.T.S

ISOLATION JOINT 20mm


A393 FABRIC MESH THICK COMPRESSIBLE EDGE OF OTHER
6 FILLER BOARD WITH
SEALANT TO
STRUCTURE FABRIC MESH
TOC
50

ARCHITECT'S DETAILS
TOC

50
PER 50 200

PER 50 H
2H 2H
0
2H

100% CONSTRUCTION DOCUMENTS FOR TENDER 24.08.2017 NS


SPEC

HARDCORE AUTHORITY APPROVAL 0 08.08.2017 NS

SPEC
AS

HARDCORE

AS

S
1
2 Purpose of Issue Rev. Date Appoved
SUB-GRADE SUB-GRADE Client:
WATERPROOFING IF REQUIRED
WATERPROOFING IF REQUIRED
50mm BLINDING
50mm BLINDING
1000 GAUGE POLYTHENE SHEET
5 1000 GAUGE POLYTHENE SHEET
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
09 TYPICAL
SCALE:
DETAILS OF GRADE SLAB (200mm) THICKNESS
N.T.S 10 TYPICAL
SCALE:
EDGE DETAILS OF ON GRADE SLAB
N.T.S
E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:

SAW CUT OR FORMED GROVE, SAW CUT OR FORMED GROVE,


5mm 5mm
WIDE, SEALED TO ARCHITECT'S INDUCED CRACK WIDE, SEALED TO ARCHITECT'S BUTT JOINT
DETAILS DETAILS (UNTREATED) abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
A393 FABRIC MESH 50 50 50 50 www.ae-7.com
FABRIC MESH FABRIC MESH Hassanicor Building, 6th Floor, Al Barsha 1
TOC TOC
50

50

PO Box 54115 Dubai, UAE


P: +971 4 3997758 F: +971 4 3997759
4
PER 50 H

PER 50 H

H/2

Sub-Consultant:
50

EQUAL EQUAL EQUAL EQUAL


SPEC

SPEC

HARDCORE HARDCORE
AS

AS
S

SUB-GRADE SUB-GRADE

WATERPROOFING IF REQUIRED MILD STEEL DOWEL BARS, 20mm DIA. WATERPROOFING IF REQUIRED
x
50mm BLINDING 500LG @ 300 CTS DE-BONDED OVER 50mm BLINDING
TWO THIRDS LEHGTH. (SET
1000 GAUGE POLYTHENE SHEET PERPENDICULAR TO JOINT) 1000 GAUGE POLYTHENE SHEET Project Name:

3 11 INDUCED
SCALE:
TIED JOINT (IT)
N.T.S 12 FORMED
SCALE:
DOWELLED CONTRACTION JOINT (FDC)
N.T.S
DUBAI WATER CANAL
SAFA A
SAW CUT OR FORMED GROVE, 5mm
WIDE, SEALED TO ARCHITECT'S JOINT COMPRISES COMPRESSIBLE FILLER BOARD, DUBAI-UAE
DETAILS BUTT JOINT 20mm THICK, WITH SEALANT TO ARCHITECT'S DOWEL CAP, END FILLED WITH
(UNTREATED) DETAILS COMPRESSIBLE MATERIAL
50 50 50 20 50
Project Description:
FABRIC MESH FABRIC MESH
TOC 100 20
TOC
MIXED USE DEVELOPMENT
50

50

(RETAIL & RESIDENTIAL)


PER 50 H

PER 50 H
H/2

H/2

EQUAL EQUAL PLOT 02 / 3435336


SPEC

SPEC

HARDCORE HARDCORE
AS

AS
S

2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)


SUB-GRADE SUB-GRADE
Drawing Title:
MILD STEEL DOWEL BARS, 12mm DIA.
WATERPROOFING IF REQUIRED WATERPROOFING IF REQUIRED
MILD STEEL DOWEL BARS, 20mm DIA. x
x
900 LG. @ 600 CTS. (SET
PERPENDICULAR TO JOINT)
50mm BLINDING
1000 GAUGE POLYTHENE SHEET
550 LG. @ 300 CTS. DE-BONDED OVER
TWO THIRDS LENGTH (SET
PERPENDICULAR TO JOINT)
50mm BLINDING
1000 GAUGE POLYTHENE SHEET
STRUCTURAL GENERAL DETAILS -
12
13 LONGITUDINAL
SCALE: N.T.S
JOINT (LJ) 14 EXPANSION
SCALE:
JOINT (EJ)
N.T.S

Scale Drawn Checked Approved Size


AA MA NS
1 N.T.S A1
26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-02-02-00-SG0017 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

200 OR 300
T10-300

----
D
LINKS

T10

1500 MAX. (FOR 200 THICK)


2500 MAX. (FOR 300 THICK)
T10 T10
300 1500 300 T10 T16-160 (FOR T10-300 (FOR 200
200 THICK) T16-200
T10 THICK) T16-200 E.F.

200
T10-300 E.F. E.F. (FOR 300
T12-300 T12-300 T12-300 (FOR 300 THICK)
THICK) T10-300 E.F.
C T10-300 E.F. T16-160 (FOR (FOR
T10-300 E.F. ---- 200 200 THICK) T10- N
T10

1250 MAX.
10 THICK) T16-200 250 KEY PLAN

(MIN. 750)
T10-250 E.F.

D+300
T10-250 E.F. E.F. (FOR 300 E.F. (FOR 300
100 100 THICK) THICK)
T12-300
T10-300 SLAB RFT
100

200
150

T10-300

200 MIN.750 200


mm mm TRIMMING BEAMS FOR
MANHOLE.
T8-150 T10-250
9 75 THICK
BLINDING LAYER

01 TYPICAL
SCALE:
DETAILS OF PORTIABLE PLANTER
N.T.S 02 TYPICAL
SCALE:
R.C. DETAIL OF MANHOLE
N.T.S C SECTION
SCALE:
(C)
N.T.S 06 TYPICAL
SCALE:
DETAILS OF PARAPET WALL
N.T.S
General Notes:
1. DO NOT SCALE FROM THIS DRAWING.
150
GALVANIZED T16 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.
T10 T10

80
REINF'T FOR T10 REINF'T FOR HORIZ. BARS VERT. BARS
T10 FLOOR BEAM 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
FLOOR BEAM
T10 SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 T10-300
LINKS 150x80x65 BOXOUT AT SITE.

300 300 T10-300 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
VARIES PLAN ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
T10-300
T10 AND RELEVANT SECTIONS OF THE SPECIFICATION.
150
T10-250 T10-250
T12-300 T12-300 T12-300 SPLAY BARS TOP LEVEL AT FFL
VERT. BARS

65
T10-300 E.F.
1250 MAX.

HORIZ. BARS

150 MIN.
T12-300 T10-300
GALVANIZED T16
7
ELEVATION
SLAB REINF'T FOR COVERS > 1500mm LONG (MIN. 2 HOOPS PER COVER UNIT)
T8-150 T10-250
75 THICK
BLINDING LAYER

LIFTING HOOP - IN ANY ORIENTATION


D SECTION (D) 05 TYPICAL TANK WALL CORNER DETAILS 07 TO AVOID EXPOSING OTHER REINFORCEMENT
03 TYPICAL DETAILS OF PLANTER WALL SCALE: N.T.S
SCALE: N.T.S SCALE: N.T.S
SCALE: N.T.S

6
N.
8D. MIN.
0 MI ALT. CROSS TIE
10D.MAX. 10

db
IN. END IN ALL

=6
. M AX.
----
A

D
8 .M CROSS CASES

R
0 NS

LE
100% CONSTRUCTION DOCUMENTS FOR TENDER 24.08.2017
10D TIE

AL
DETAILING 0 NS

SM
AUTHORITY APPROVAL 08.08.2017
250

5&
DIMENSION

db
. Purpose of Issue Rev. Date Appoved

T2
MIN D

100 MIN.
150 Client:

T16 & SMALLER = 6db


B
D
H

T19, T22, T25 = 12db


---- db
750
UN

65 MIN.
O

4db
T12-200 E.F. COLUMN REINFORCEMENT
5
550

T10-300 E.F. 2r OR 5mm + DIA. OF COLUMN BAR MEYDAN L.L.C


WHICHEVER IS GREATER P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
250

E: info@dubairacingclub.com W: www.dubairacingclub.com
300

Principal Consultant:
750 750 8.1 LINKS
SCALE: N.T.S 8.2 SPANDREL
SCALE:
& BEAM SUPPLEMENTARY TIE
N.T.S 8.3 STANDARD
SCALE:
180-DEGREE HOOK
N.T.S
250 UN 250
O 250 UN 250
O
T10-300 T12-200 T16 & SMALLER = 6db abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh

.
IN
T19, T22, T25 = 12db www.ae-7.com

0M
T25 & SMALLER = 6db Hassanicor Building, 6th Floor, Al Barsha 1

10
PO Box 54115 Dubai, UAE

db
100mm MIN.

=6
P: +971 4 3997758 F: +971 4 3997759
4

R
LE
Sub-Consultant:

DIMENSION
DETAILING
AL
CL BEAM 10
0M

SM
04 TYPICAL R.C. DETAIL OF SUMP PIT IN LIFT PIT B SECTION (B)
D IN

5&
SCALE: N.T.S SCALE: N.T.S
D .

T2
db db
db

Project Name:

DUBAI WATER CANAL


H

3
8.4 BEAM
SCALE:
& JOIST STIRRUP
N.T.S 8.5 COLUMN
SCALE:
& SPANDREL TIE
N.T.S 8.6 135-DEGREE
SCALE:
STIRRUP/TIE HOOK
N.T.S
SAFA A
T12-200 E.F.
DUBAI-UAE
550

T10-300 E.F.

Project Description:
DETAILING NOTES:
300

WIRE TOGETHER DIMENSION MIXED USE DEVELOPMENT

db
EACH END 1. REFERENCE ACI 318M-05.
300 750 300 2. db = BAR DIAMETER. (RETAIL & RESIDENTIAL)
PLOT 02 / 3435336

EXTENSION
3. D = DIAMETER OF BEND

100 MIN.
CLASS "B"

U.N.O.
T12-200 T10-300 D
2 SPLICE U.N.O. 12db D = 6db FOR 8 THRU 25 BARS BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
D = 8db FOR 32 THRU 36 BARS
D = 10db FOR 40 AND LARGER Drawing Title:

8.7 TIE LAP DETAIL


SCALE: N.T.S 8.8 STANDARD
SCALE:
90-DEGREE HOOK
N.T.S
STRUCTURAL GENERAL DETAILS -
13
A SECTION (A)
08 TYPICAL BAR BENDING DETAILS
SCALE: N.T.S
SCALE: N.T.S
Scale Drawn Checked Approved Size
AA MA NS
1 N.T.S A1
26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-02-02-00-SG0018 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

1-T20 BAR x 350 LONG NOTES:


DEBONDED IN POST
SUSPENDED SLAB

S019
1-T20 BAR x 350 LONG DEBONDED IN POST 1.01 ALL MASONRY CONSTRUCTION SHALL CONFORM TO BS 6073, BS 5628 AND

A
CONTROL JOINT
SPECIFICATIONS.

1.02 ALL CONTROL JOINTS ARE TO BE FILLED WITH COMPRESSIBLE EXPANDABLE


FILLER, REFER ALSO TO PROJECT SPECIFICATIONS FOR FIRE RATED WALLS. N
10 KEY PLAN
1.03 ALL WALL FINISHES MUST BE JOINTED AT THE WALL JOINTS TO PREVENT
UNCONTROLLED CRACKS IN THEM.

1.04 GREAT CARE MUST BE TAKEN TO ENSURE THAT MORTAR DROPPINGS AND
OTHER HARD MATERIALS DO NOT FALL OR REMAIN IN THE CONTROL JOINTS.
1 POLYSTYRENE TO BE PLACED IN ALL VERTICAL JOINTS DURING CONSTRUCTION
S019 IN MASONRY TO AVOID MORTAR DROPPINGS FILLING THE JOINTS.

1.05 ALL JOINTS ARE TO BE REVIEWED AND APPROVED BY THE ARCHITECT OR HIS
S019 REPRESENTATIVE PRIOR TO USE.
B
S019
9 1.06 WHERE FILLER MATERIALS ARE NOT SPECIFIED BY A TRADE NAME, THE
D
S019 CONTRACTOR SHALL SUBMIT THE NAME OF HIS PROPOSED FILLERS TO THE
B CONSULTANT FOR REVIEW PRIOR TO USE.

BCJ BCJ FIXED END CONCRETE COLUMN 1.07 THE CONTACTOR'S ATTENTION IS DRAWN TO THE MANUFACTURER'S General Notes:
SUPPORT POST SUPPORT POST REQUIREMENTS WITH REGARD TO THE POSITION OF THE FLEXIBLE ANCHORS
FOR FOR BCJ WHEN FIXED. THE MANUFACTURER'S WRITTEN RECOMMENDATIONS SHALL BE 1. DO NOT SCALE FROM THIS DRAWING.

BLOCKWORK F F BLOCKWORK FOLLOWED STRICTLY. 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
1.08 THE CONTRACTOR IS TO TAKE PARTICULAR CARE TO ENSURE THAT ALL BY THE ENGINEER.
PERPENDS AND BEDS ARE PROPERLY FILLED WITH MORTAR. 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8
1.01 REFER TO ARCHITECTURAL PLANS AND ELEVATIONS FOR LOCATIONS OF AT SITE.

CONTROL JOINTS. 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
4250 MAX. BETWEEN CONTROL JOINTS 4250 MAX. BETWEEN FIXED END AND CONTROL JOINT 1.10 PROVIDE RESTRAINT TO ALL MASONRY AT SOFFIT OF SLAB OVER AS REQUIRED. AND RELEVANT SECTIONS OF THE SPECIFICATION.

NOTES: 1.11 WHERE STARTER BARS, ANCHOR BOLTS, ETC. ARE SHOWN PROJECTING INTO
2 MASONRY, BUILD THESE TIGHTLY INTO MASONRY VOIDS WITH MASONRY GROUT.
BED JOINT REINFORCEMENT EVERY SECOND 1. BCJ. DENOTES BLOCKWORK CONTROL JOINT. REFER ARCH. PLANS FOR LOCATION
COURSE S019 1.12 PROVIDE HORIZONTAL BED JOINT REINFORCEMENT AS PER SPECIFICATIONS AND
2. WALL TIES TO BE PLACED AT 400mm VERTICAL SPACING 1000mm HORIZONTAL SPACING(STAGGERED)
(EXTERNAL SINGLE LEAF WALL ONLY) DETAILS ON DRAWINGS.
3. ALL DETAILS SHOWN ARE FOR NON LOAD BEARING BLOCKWORK (UNO)

01 TYPICAL BLOCKWORK ELEVATI0N


7 1.13 PROVIDE LINTELS OVER ALL OPENINGS OR RECESSES IN MASONRY WALLS,
SCALE: N.T.S INCLUDING THOSE FOR MECHANICAL OR ELECTRICAL SERVICES OR EQUIPMENT.
SEE TYPICAL DETAILS FOR LINTEL SIZES FOR NON-LOAD BEARING MASONRY
WALLS.
B 1.14 THE AVERAGE MATERIAL DENSITY OF MASONRY UNITS TO BE AS FOLLOWS:
HOLLOW MASONRY UNITS : 750 Kg/Cubic M
HOLLOW BLOCKWORK UNITS : 1500 Kg/Cubic M

BED JOINT REINFORCEMENT OVER LINTEL 600 LAP FORM OPENING EDGE 1.15 FIRE RATING REQUIREMENTS, SOUND AND THERMAL INSULATION PROPERTIES TO
HORIZONTAL O BE AS PER PROJECT SPECIFICATIONS.
6 REINFORCEMENT WITH GALAVANISED STEEL MESH OF 4mm DIA
1.16 CUTTING AND CHASING OF MASONRY WALLS TO BE STRICTLY IN ACCORDANCE
LONGITUDINAL WIRES WITH THE SPECIFICATION AND DM REQUIREMENTS.
AND 2.52mm DIA CROSS WIRE. LAP REIN. 150mm AT EVERY SECOND LAYER
CONCRETE LINTEL
C REINF. SYMM.
LINKS A 1.17 MORTAR MIX TO BE 1:1:6 (CEMENT:LIME:SAND) OR APPROVED EQUIVALENT. 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
AUTHORITY APPROVAL 0 08.08.2017 NS
CLEAR SPAN 1.18 TIES @400C/C TO ALL STRUCTURE COLUMN/SHEAR WALLS VERTICALLY WITH Purpose of Issue Rev. Date Appoved
MINIMUM 125MM FULL EMBEDMENT EACH SIDE OF THE ANCHOR.
Client:

03 LINTEL
SCALE:
BEAM DETAIL -1
N.T.S
1.19 DEFLECTION JOINTS @ HEADS WITH HORIZONTAL STABILIZATION BY STRUCTURAL
ANGLES ATTACHED TO U/S SIDE OF JOINT
600 600
40 DIA. OF BAR
5
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
30 mm DEFLECTION JOINT T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com
ANGLE AT OPPOSITE
SIDE OF WALL Principal Consultant:
1200
VERTICAL O
SIDES 600
C
OF DOORS S019 abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com
AND Hassanicor Building, 6th Floor, Al Barsha 1
WINDOWS TO WINDOW OR DOOR
LINKS PO Box 54115 Dubai, UAE
4 BE
CLEAR SPAN
CONCRETE FACE Sub-Consultant:
P: +971 4 3997758 F: +971 4 3997759

GROUTED

S019
A
WITH C E
C15/10 CONC. S019 CONTRACTOR TO ENSURE CORRECT S019 100x100x6x150mm ANGLE
FILL MINIMUM STARTER BARS ARE CAST INTO FIXED TO SLAB FOR
OF CONCRETE ELEMENTS AS NECESSARY MOVEMENT OF
HALF BLOCK BLOCKWALL
SSL NOTES: @ EVERY
20mm CONTROL JOINT FILLED WITH 1200 C/C
Project Name:
1. BEARING ON BLOCK WALL ON EITHER SIDE OF OPENING SHALL BE FIRE RESISTANT COMPRESSIBLE

3 04 LINTEL
SCALE:
BEAM DETAIL - 2
N.T.S
AT LEAST EQUAL TO THE OVERALL DEPTH OF THE LINTEL JOINT
FILLER TO ARCHITECTS
DUBAI WATER CANAL
BED JOINT REINFORCEMENT
2. OVERALL LINTEL DEPTHS COULD BE INCREASED SPECIFICATION. SAFA A
TO SUIT BLOCK WORK COURSING
DUBAI-UAE
LINTEL SIZE REINFORCEMENT
Project Description:
WIDTH DEPTH TOP BOTTOM LINKS
MIXED USE DEVELOPMENT
2.50M 200mm 200mm 2-T12 2-T12 T8@125 (RETAIL & RESIDENTIAL)
TYPICAL BLOCKWORK DETAIL > 2.50M 4.50M 200mm 300mm 2-T16 2-T16 T8@175 PLOT 02 / 3435336

02 WINDOW OR DOOR OPENING


2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
> 4.50M 6.50M 200mm 400mm 2-T16 2-T20 T8@200
SCALE: N.T.S ELEVATION ON NON-LOAD Drawing Title:

17 SCHEDULES OF LINTEL (UNO) 02 BEARING BLOCK WORK WALL


SCALE: N.T.S
SCALE: N.T.S
STRUCTURAL GENERAL DETAILS -
14

Scale Drawn Checked Approved Size


AA MA NS
1 N.T.S A1
26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-02-02-00-SG0019 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

T8-100 CTS 4T10

N
10 KEY PLAN

30

30
100x100x6x150mm ANGLE
FIXED TO SLAB FOR MOVEMENT 30mm DEFLECTION JOINT FILLED 30mm DEFLECTION JOINT FILLED
OF BLOCKWALL @ EVERY 1200 FIRE RESISTANT COMPRESSIBLE FIRE RESISTANT COMPRESSIBLE
C/C STAGGERED JOINT FILLER TO ARCHITECTS JOINT FILLER TO ARCHITECTS 200 x 200 POST FOR
(1 NO. ANGLE AT 600 C/C SPECIFICATION. BLOCKWORK SUPPORT POST
SPECIFICATION. 200 THK. BLOCKWORK
9 TOTAL ALTERNATIVE SIDE)

FOR FIRE COMPARTMENTS WALLS AND FOR ORDINARY PARTITIONS General Notes:
ORDINARY WALLS OF HEIGHT MORE THAN 4 METERS 1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES

B SECTION (B) SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK


8
A SECTION (A) AT SITE.
SCALE: N.T.S
SCALE: N.T.S 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

C15/10 GROUT FILLED


20 mm CONTROL JOINT FILLED
WITH FIRE RESISTANT SLEEVED METAL TIES@ 200 mm
7 CONCRETE COLUMN C/C VERTICALLY
COMPRESSIBLE JOINT FILLER

WALL TIES AT
SLIDING PLASTIC
EVERY OTHER
SLEEVED WALL TIES AT
COURSE FIXED TO
EVERYOTHER COURSE
COLUMN
FIXEDTO COLUMN
T12 VERTICAL REINFORCEMENT
6

FIXED END CONTROL JOINT IN BLOCKWALL WALL


100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
AUTHORITY APPROVAL 0 08.08.2017 NS
Purpose of Issue Rev. Date Appoved
BCJ
Client:

5
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.

C SECTION (C) D SECTION (D) E SECTION (E) T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com
SCALE: N.T.S SCALE: N.T.S SCALE: N.T.S
Principal Consultant:

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
1-T20 BAR x 350 LONG PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
DEBONDED IN POST REINFORCED Sub-Consultant:
CONCRETE BCJ

125
BLOCK WORK HEAD RESTRAINT
FLOOR SLAB
HORIZONTAL REINFORCEMENT DETAILS SHOWN ON THIS
WITH GALAVANISED STEEL DRAWING ARE APPLICABLE
MESH OF 4mm DIA WHERE FALSE CEILINGS U/S SLAB OR BEAM
LONGITUDINAL WIRES AND PRESENT. 100
2.52mm DIA CROSS WIRE. LAP FIRE RESISTANT COLUMN BARS Project Name:
20

550
REIN. 150mm AT EVERY SECOND
3 LAYER
COMPRESSIBLE JOINT DUBAI WATER CANAL
150 FILLER 1-T12 STARTER SAFA A
LAP BAR CENTRALLY DUBAI-UAE

25mm. DIA PURPOSE


Project Description:
MADE CAP WITH MIXED USE DEVELOPMENT
COMPRESSIBLE FILLER (RETAIL & RESIDENTIAL)

VARIES
PLOT 02 / 3435336
BCJ
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
COLUMN BARS Drawing Title:

STRUCTURAL GENERAL DETAILS -


15
F SECTION (F) 01 DETAIL (1) 02 DETAIL (2)
SCALE: N.T.S SCALE: N.T.S SCALE: N.T.S
Scale Drawn Checked Approved Size
AA MA NS
1 N.T.S A1
26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-02-02-00-SG0020 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

02 04
LINKS CIP SLAB LINKS CIP SLAB

N
10 KEY PLAN

750
LINKS LINKS

01 01 03 03

EQ

EQ
9

EQ

EQ
EQ

EQ
50 AS PER DESIGN General Notes:
1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

02 04

7
PS1 TYPICAL PUNCHING SHEAR DETAIL (INTERNAL COLUMN)
SCALE: 1:25
PS2 TYPICAL
SCALE:
PUNCHING SHEAR DETAIL (EDGE COLUMN)
1:25

LINKS
SLAB RFT
6

SLAB
100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
LINKS
SLAB RFT SLAB RFT 50 AUTHORITY APPROVAL 0 08.08.2017 NS
AS PER PLAN Purpose of Issue Rev. Date Appoved
Client:
SLAB

SLAB

50 50 R.C. COLUMN
5
AS PER PLAN AS PER PLAN MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:
R.C. COLUMN

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh

03 SEC. (03-03) www.ae-7.com


Hassanicor Building, 6th Floor, Al Barsha 1
SCALE: 1:25 PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
01 SEC. (01-01) Sub-Consultant:
SCALE: 1:25

LINKS LINKS
SLAB RFT SLAB RFT SLAB RFT SLAB RFT
Project Name:

DUBAI WATER CANAL


SLAB

SLAB

SLAB

SLAB
3
SAFA A
50 50 50 50
AS PER PLAN AS PER PLAN AS PER PLAN AS PER PLAN DUBAI-UAE

Project Description:

R.C. COLUMN R.C. COLUMN MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
PLOT 02 / 3435336
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
Drawing Title:
02 SEC. (02-02) 04 SEC. (04-04)
SCALE: 1:25 SCALE: 1:25
STRUCTURAL GENERAL DETAILS -
16

Scale Drawn Checked Approved Size


AA MA NS
1 N.T.S A1
26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-02-02-00-SG0021 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

1 ELASTOMERIC, CEMENT WATERPROOF COATING 1 REINJECTABLE HOSE


11 1 1 BASEMENT WALL / RETAINING WALL N
10 1
2 GEOTEXTILE 2 PROTECTION SCREED - MIN. 50mm. THICK
2 2 GEOTEXTILE
KEY PLAN
2 3 PVC WATERPROOFING MEMBRANE 2mm. THICK 3 2mm MEMBRANE WELDED TO WATER STOP 3
1 3 PVC WATERPROOFING MEMBRANE 2mm. THICK
3 4 2mm MEMBRANE WELDED TO WATER STOP 4 WATER STOP
4
4 5 WATER STOP 5 GEOTEXTILE 4 2mm MEMBRANE WELDED TO WATER STOP
5
5 2 6 BLINDING SCREED - SMOOTH FINISH 5 WATER STOP
6 HYDROSWELLING WATER BAR WITH PROPER ADHESIVE
3 1 6 6 REINJECTABLE HOSE
7 REINFORCING FIBER MESH
6 7
8 RAFT SLAB 7 PROTECTION BOARD 6mm. THICK
7 4
9 PROTECTION SCREED - MIN. 50mm. THICK 8 RAFT SLAB
5 9 PROTECTION SCREED - MIN. 50mm. THICK
10 BLINDING SCREED - SMOOTH FINISH 8
8 11 PROTECTION BOARD 6mm. THICK 1 REINJECTABLE HOSE 4 2 10 BLINDING SCREED - SMOOTH FINISH
2 PROTECTION SCREED - MIN. 50mm. THICK 9
9 6 3
3 BLINDING SCREED - SMOOTH FINISH
9 3
4 GEOTEXTILE
5
6 2
2 5 PVC WATERPROOFING MEMBRANE 2mm. THICK 10
10 3
6 BLOCKWORK
4
General Notes:
A TYPICAL
SCALE:
TERMINATION DETAIL @ WATER TANK
N.T.S B TYPICAL
SCALE:
LIFT PIT/SUMP PIT DETAIL
N.T.S C TYPICAL
SCALE:
CONSTRUCTION JOINT DETAIL
N.T.S C TERMINATION
SCALE: N.T.S
DETAIL @ PLOT LINE 1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.
1 1 1 GUNITE SMOOTH SURFACE
1 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
1 GUNITE SMOOTH SURFACE 2 2 GEOTEXTILE SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 2 3 3 PVC WATERPROOFING MEMBRANE 2mm. THICK AT SITE.
3 2 GEOTEXTILE
4 4 2mm MEMBRANE WELDED TO WATER STOP 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
4 3 PVC WATERPROOFING MEMBRANE 2mm. THICK
GROUND LEVEL 5 ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
5 4 2mm MEMBRANE WELDED TO WATER STOP 5 WATER STOP
AND RELEVANT SECTIONS OF THE SPECIFICATION.
5 WATER STOP 6 6 INJECTABLE HOSE

SHORING
6 7 PROTECTION BOARD 6mm. THICK

SHORING WALL
6 REINJECTABLE HOSE 7
2 7
7 PROTECTION BOARD 6mm THICK 8 RAFT SLAB
3 1 2 COATS OF ELASTOMERIC, CEMENT BASED
8 9 PROTECTION SCREED - MIN. 50mm. THICK
WATERPROOF COATING 8 RAFT SLAB
9 PROTECTION SCREED - MIN. 50mm. THICK 6 10 BLINDING SCREED - SMOOTH FINISH
2 WATER STOP 8
3 2mm MEMBRANE WELDED TO WATER STOP 10 BLINDING SCREED - SMOOTH FINISH 9
4 9 3
4 GEOTEXTILE 3
5
5 PVC WATERPROOFING MEMBRANE 2mm. THICK
7 6
2
6 PROTECTION BOARD 6mm. THICK 2 10
10

E TERMINATION
SCALE: N.T.S
DETAIL @ GROUND LEVEL D1 TERMINATION
SCALE: N.T.S
DETAIL @ GUNITE DIAPHRAGM WALL D2 GENERAL
SCALE:
SECTION TERMINATION DETAIL
N.T.S

8 9 1 HIGH STRENGTH FLOWABLE EPOXY GROUT


1 REINJECTABLE HOSE MIN. 50mm.
6 1
2 HIGH STRENGTH FLOWABLE EPOXY GROUT 2 PVC WATERPROOFING MEMBRANE 2mm. THICK
1 GEOTEXTILE
MIN. 50mm. 2 3 ADDITIONAL LAYER
4 2 PVC WATERPROOFING MEMBRANE 2mm. THICK 1
3 PVC WATERPROOFING MEMBRANE 2mm. THICK 3 2mm. PVC WATERPROOFING MEMBRANE
5 3 BLOCKWORK 4 PROTECTION SCREED - MIN. 50mm. THICK
2 4 PROTECTION SCREED - MIN. 50mm. THICK
4 4 0
4 PROTECTION SCREED - MIN. 50mm. THICK
5 BLINDING SCREED - SMOOTH FINISH 5 BLINDING SCREED - SMOOTH FINISH 100% CONSTRUCTION DOCUMENTS FOR TENDER 24.08.2017 NS
1 5 BLINDING SCREED - SMOOTH FINISH 5 5 6 GEOTEXTILE AUTHORITY APPROVAL 0 08.08.2017 NS
6 GEOTEXTILE
2 6 HIGH STRENGTH FLOWABLE EPOXY GROUT 4 4
3
6 7 PROFILING WITH HIGH STRENGTH, SHRINKAGE 7 7 PROFILING WITH HIGH STRENGTH, SHRINKAGE Purpose of Issue Rev. Date Appoved
MIN. 50mm. 5 5 2 COMPENSATED CEMENTITIOUS MICRO
COMPENSATED CEMENTITIOUS MICRO CONCRETE
2 7 ADDITIONAL LAYER OF 2mm PVC MEMBRANE 6 CONCRETE Client:
8 REINJECTABLE HOSE JUNCTION BOX
7 7
8 PROFILING WITH HIGH STRENGTH, SHRINKAGE 3 9 REINJECTABLE HOSE VENT PIPES
4 4 COMPENSATED CEMENTITIOUS MICRO CONCRETE 6
5 5
5 8
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
F1 TYPICAL
SCALE:
PILE WATERPROOFING DETAIL WITH INJECTION HOSE
N.T.S F2 TYPICAL
SCALE:
PILE DETAIL ABOVE BLINDING LEVEL
N.T.S
E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:
F TYPICAL
SCALE:
PILE WATERPROOFING DETAIL
N.T.S
EPOXY BONDED SEAL

HIGH STRENGTH
EPOXY BEDDING PROTECTION BOARD abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com
FILLER Hassanicor Building, 6th Floor, Al Barsha 1
GEOTEXTILE PO Box 54115 Dubai, UAE
DETAIL 'G1' P: +971 4 3997758 F: +971 4 3997759
4 WATER BAR
PVC WATERPROOFING MEMBRANE 2mm. THICK
Sub-Consultant:
1 G1 DETAIL
SCALE:
'G1'
N.T.S HIGH STRENGTH
EPOXY BEDDING
2 CONCRETE SLAB
EPOXY BONDED SEAL SOIL FILL
3 WATER STOP
4
4 FILLER
3 ADDITIONAL LAYER OF
5 2mm PVC MEMBRANE WATER BAR
1 PROTECTION SCREED - MIN. 50mm. THICK WELDED TO WATER STOP WATER STOP
6 REINJECTABLE HOSE
2 BLINDING SCREED - SMOOTH FINISH ADDITIONAL LAYER OF
PVC WATERPROOFING
Project Name:
1 3 GEOTEXTILE 2mm PVC MEMBRANE WELDED
REINJECTABLE HOSE MEMBRANE 2mm. THICK
DUBAI WATER CANAL
TO WATER STOP
2 4 PVC WATERPROOFING MEMBRANE 2mm. THICK
GEOTEXTILE
3 5 BLOCKWORK / SHUTTERING BLINDING
6 GROUND BEAM SAFA A
DUBAI-UAE
H TYPICAL
SCALE:
GROUND BEAM DETAIL
N.T.S

Project Description:

G EXPANSION
SCALE:
JOINT DETAIL VERTICAL & HORIZONTAL
N.T.S
MIXED USE DEVELOPMENT
(RETAIL & RESIDENTIAL)
PLOT 02 / 3435336
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
Drawing Title:

STRUCTURAL GENERAL DETAILS -


17

Scale Drawn Checked Approved Size


AA MA NS
1 N.T.S A1
26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-02-02-00-SG0022 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

N
10 KEY PLAN

1 4 1

PROTECTION BOARD 6mm. THICK


1 REINJECTABLE HOSE

2 WATER STOP PVC WATERPROOFING

MEMBRANE 2mm. THICK


3 2mm. PVC WATERPROOFING MEMBRANE WELDED TO WATER STOP
2 GEOTEXTILE
4 CONCRETE RAFT
WELDING

5 GEOTEXTILE

6 PVC WATERPROOFING MEMBRANE 2mm. THICK JUBILEE CLIP

JOINT SEALANT
BLINDING SCREED - SMOOTH FINISH
9
7

5
3
9
8 PROTECTION SCREED - MIN. 50mm. THICK

6
10 DEEP WELL STEEL CAP
9
7
10 POLYURETHANE SEALANT

11

15 12

13
11

12
JUBILEE CLIP

WATERPROOFING SWELLING PASTE


General Notes:
8
13 HIGH STRENGHT FLOWABLE EPOXY GROUT MIN. 50mm.
1. DO NOT SCALE FROM THIS DRAWING.
7
14 ADDITIONAL LAYER OF 2mm. PVC WATERPROOFING MEMBRANE

14
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
15 PROTECTION BOARD 6mm. THICK
PVC WATERPROOFING
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
MEMBRANE 2mm. THICK BY THE ENGINEER.

WATERPROFING 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


SWELLING PASTE
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 ADDITIONAL PIECE OF MEMBRANE AT SITE.
WELDED TO THE MAIN MEMBRANE

J DEWATERING
SCALE: N.T.S
WELL WATERPROOFING DETAIL
PVC WATERPROOFING
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
MEMBRANE 2mm. THICK
AND RELEVANT SECTIONS OF THE SPECIFICATION.
GEOTEXTILE

PROTECTION BOARD 6mm. THICK

CEMENT RENDER

M PIPE PENETRATION DETAIL - ABOVE WATER LEVEL


JOINT SEALANT

SCALE: N.T.S

7 ALUMINIUM FLASHING/TERMINATION STRIP

MECHANICAL FIXING

PROTECTION BOARD 6mm. THICK

PROTECTION BOARD 6mm. THICK

LANDSCAPING / PLANTING
GEOTEXTILE

PVC WATERPROOFING

100mm. THICK RC CAP MEMBRANE 2mm. THICK

WELDING
SLOPED LIGHT WEIGHT CONCRETE,

DENSITY 13 kN/m3 JOINT SEALANT

6
JUBILEE CLIP

PVC WATERPROOFING MEMBRANE


HIGH STRENGTH FLOWABLE
2mm. THICK
EPOXY GROUT min. 50mm

GEOTEXTILE 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


CONCRETE SLAB AUTHORITY APPROVAL 0 08.08.2017 NS
Purpose of Issue Rev. Date Appoved
Client:

K WATERPROOFING
SCALE: N.T.S
DETAILS BELOW LANDSCAPING @ GROUND FLOOR WITH UPSTAND
PVC WATERPROOFING
MEMBRANE 2mm. THICK

5
MEYDAN L.L.C
WATERPROOFING
SWELLING PASTE

P.O. Box 9305, Dubai , UAE.


ADDITIONAL PIECE OF MEMBRANE
WELDED TO THE MAIN MEMBRANE
T: +9714 3270000 F: +9714 3270007
1 E: info@dubairacingclub.com W: www.dubairacingclub.com
2

3
PVC WATERPROOFING
MEMBRANE 2mm. THICK Principal Consultant:
4
GEOTEXTILE

PROTECTION BOARD 6mm. THICK

1 LANDSCAPING / PLANTING abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com
2 100mm. THICK RC CAP
Hassanicor Building, 6th Floor, Al Barsha 1
3 2mm. THICK PVC WATERPROOFING MEMBRANE PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4 4 GEOTEXTILE

5 SLOPED LIGHT WEIGHT CONCRETE, DENSITY 13 kN/m3


Sub-Consultant:
6 CONCRETE SLAB

N PIPE
SCALE:
PENETRATION DETAIL - BELOW WATER LEVEL
N.T.S
5

Project Name:

3
DUBAI WATER CANAL
SAFA A
DUBAI-UAE
L WATERPROOFING
SCALE: N.T.S
DETAILS BELOW LANDSCAPING @ GROUND FLOOR
Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
PLOT 02 / 3435336
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
Drawing Title:

STRUCTURAL GENERAL DETAILS -


18

Scale Drawn Checked Approved Size


AA MA NS
1 N.T.S A1
26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-02-02-00-SG0023 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

PRIMARY BEAM MAX SECONDARY BEAM PRIMARY BEAM SECONDARY BEAM


MAX TAPER STIFFENER PLATE SAME

50 TYP.
NOTCHLENG20 NOTCHLENG 20 THICKNESS AS BEAM FLANGE

50 TYP.
16 MINIMUM. (TOP & BOTTOM SIMILAR) N
10 TH TH KEY PLAN
N STIFFENER PLATE SAME
N THICKNESS AS BEAM FPBW
FLANGE 16
2d 75 FPBW

20
FPBW

70 TYP. d2
MINIMUM. (TOP AND

70 TYP. d2
MAX.
BOTTOM FILLET WELD

60
SIMILAR) (THICKNESS=PLATE THICKNESS)

50
FILLET WELD ALL FPBW
100 n + 12

L
ROUND

L
TYP. TOP &

D
FILLET WELD ALL ROUND (THICKNESS = BOTTOM

20
BOTH 'T') (OR
9 SIDE (THICKNESS='T') (OR
A A THICKNESS =
ERECTION BOLTS
d2 0.8T CFW THICKNESS = '0.8T' FOR '0.8T' FOR Fab.) I

d2
0.8T CFW FPBW AS REQUIRED.
Fab. ) I

50
d1 d1 50 PLATE THICKNESS CONNECTION PLATE
FIN PLATE FIN PLATE = 'T' + 6mm
W THICKNESS "T" THICKNESS "T" PLATE THICKNESS (T) = General Notes:
W BEAM WEB THICKNESS + 6 mm.

60
1. DO NOT SCALE FROM THIS DRAWING.
M20 ERECTION SECONDARY BEAM
END PROJECTION=T END PROJECTION=T BOLTS AS REQUIRED (WITH WEB THICKNESS 'T') ELEVATION 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
FPBW NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
NOTCH BOTTOM NOTCH BOTTOM NOTE BY THE ENGINEER.
FLANGE AS REQUIRED FLANGE AS REQUIRED ONE SIDED CONNECTION IS SHOWN. TWO
MAX LENGTH 'N' 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
MAX LENGTH 'N' SIDED SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 PRIMARY BEAM AT SITE.
CONNECTION IS SIMILAR.
BEAM TO BEAM 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
BOLTED BEAM TO BEAM FIN PLATE BOLTED BEAM TO BEAM FIN PLATE WELDED MOMENT CONNECTION WELDED MOMENT CONNECTION ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.
CONNECTION (SINGLE COLUMN BOLTS) CONNECTION (DOUBLE COLUMN BOLTS) N.T.S. BEAM TO COLUMN WEB
N.T.S. N.T.S. WITHOUT COVER PLATE
CL COLUMN N.T.S.
STIFFENER PLATE
TO COL. WEB
FILLET WELD
FPBW (THICKNESS=PLATE THICKNESS)
7 FPBW FPBW FPBW BEAM
FILLET WELD FIN PLATE
20 THICKNESS 'T'
20

(THICKNESS=PLATE THICKNESS)

50 TYP.
30

FILLET WELD

T1
20

20
(THICKNESS=PLATE THICKNESS)

30

30
COVER PLATES CONNECTION PLATE
CONNECTION PLATE
PLATE THICKNESS (T) =
STIFFENER PLATE SAME BEAM WEB THICKNESS + 6
100

70 TYP. 40
THICKNESS AS BEAM

30

20
n + 12
30

FLANGE FPBW TYP. TOP &


20

30
BOTTOM

20
16 MINIMUM. (TOP &

T1

0.6 D MIN.
BOTTOM 'e'(TOP & BOTTOMFPBW
ERECTION BOLTS FLANGE OFFSET)
6 SIMILAR) FPBW
AS REQUIRED. WEB CONNECTION FPBW

D
PLATE AS REQUIRED.
FOR THICKNESS OF TOP & ELEVATION
BOTTOM STIFFENER PLATE SEE NOTE 2. 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS

40
NOTE ELEVATION AUTHORITY APPROVAL 0 08.08.2017 NS
NOTES: Purpose of Issue Rev. Date Appoved
ONE SIDED CONNECTION IS SHOWN. TWO 1. WHEN TOP OR BOTTOM FLANGES ARE OFFSET AND 'e' IS GREATER THAN 75 mm 40 40 MIN.
SIDED PROVIDE STIFFENER PLATE OPPOSITE EACH FLANGE. IF 'e' IS LESS THAN OR Client:
CONNECTION IS SIMILAR. EQUAL TO 75 mm SLOPE STIFFENER PLATE BETWEEN THE OFFSET FLANGES.
WELDED MOMENT CONNECTION 2. STIFFENER PLATE SAME THICKNESS AS THICKEST FLANGE FRAMING AT THIS
PLANE. GRADE OF STIFFENER PLATE SAME AS FRAMING BEAM, 16 mm MIN.
5 BEAM TO COLUMN WEB COLUMN FLANGE/ COVER PLATE
MEYDAN L.L.C
WITH COVER PLATE WELDED MOMENT CONNECTION P.O. Box 9305, Dubai , UAE.

N.T.S. STIFFENER PLATES TO


BEAM TO COLUMN FLANGE T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com
COL. WEB & FLANGES N.T.S. Principal Consultant:
(TYP. TOP & BOTTOM)
BOLTED BEAM TO COLUMN (FLANGE)
STIFFENER PLATES
TO COL. WEB & FLANGES ALL STIFFENERS ALIGNED WITH TOP FIN PLATE CONNECTION abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
AND BOTTOM OF CONNECTION PLATE. N.T.S. www.ae-7.com
(TYPICAL TOP & BOTTOM) Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
Sub-Consultant:
STIFFENERS ALIGNED WITH TOP
AND BOTTOM OF CONNECTION PLATE

FIN PLATE TO
WEB AND
STIFFENERS

Project Name:

3
DUBAI WATER CANAL
A SAFA A
OR
DUBAI-UAE

Project Description:

SKEWED BEAM CONNECTION MIXED USE DEVELOPMENT


TO COLUMN WEB SKEWED BEAM CONNECTION (RETAIL & RESIDENTIAL)
N.T.S. TO COLUMN FLANGE
N.T.S. PLOT 02 / 3435336
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
Drawing Title:

STRUCTURAL GENERAL DETAILS -


19

Scale Drawn Checked Approved Size


AA MA NS
1 N.T.S A1
26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-02-02-00-SG0024 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

SECONDARY BEAM
MAX (450x250x16 RHS OR
PRIMARY BEAM NOTCHLENG20 500x300x16x16 FAB. RHS)
TH
N
10 N KEY PLAN

38 48
CL COLUMN
BEAM CONNECTION
PLATE AS REQUIRED

66
SECONDARY BEAM
(450x250x16 RHS)

66
FPBW

66
PRIMARY BEAM

38
9 CL BEAM CL BEAM

104
CONNECTION PLATE AS General Notes:
FIN PLATE ERECTION AID AND
65 48 THICKNESS "T"
15 (BOTH SIDE) FILLET WELD BACKING 1. DO NOT SCALE FROM THIS DRAWING.
STIFFENER PLATES STRIP
TOP & BOTTOM ERECTION BOLTS AS 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
REQUIRED BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


PLAN SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8
ELEVATION PLAN AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
BOLTED BEAM TO BEAM FIN PLATE AND RELEVANT SECTIONS OF THE SPECIFICATION.

CONNECTION
N.T.S.

CL PRIMARY BEAM
SECONDARY BEAM
n+12

7
MAIN BEAM

45°
MIN
STIFFENER PLATE

.
THICKNESS "T"
A
n+12

6 SIDES.
A

FOR CONNECTION

A
6 M20 ERECTION REFER TO TYPICAL
BOLTS AS REQUIRED. FIN PLATE DETAIL
NOTCH BEAM
IF REQUIRED. 0
20 MAX 100% CONSTRUCTION DOCUMENTS FOR TENDER 24.08.2017 NS
PLAN A-A AUTHORITY APPROVAL 0 08.08.2017 NS
Purpose of Issue Rev. Date Appoved
BEAM TO BEAM
WELDED CONNECTION BEAM SKEW (GREATER THAN 45°) Client:

N.T.S. N.T.S.
5
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com
BOLTS SHIM PLATE Principal Consultant:
C
L COLUMN

CL COLUMN TAPER STIFFENER PLATE abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
TOP AND BOTTOM www.ae-7.com
FPBW Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
CONNECTION PLATE COVER PLATE
BOLTS SPLICES PLATE Sub-Consultant:
STIFFENER PLATE CL BEAM
TOP AND BOTTOM
CL BEAM STIFFENERS

CONNECTION PLATE
AS ERECTION AID
ERECTION BOLTS AND BACKING STRIP
Project Name:
AS REQUIRED.
FPBW (TYP.) ERECTION BOLTS
3 3 SIDES STIFFENER FILLET
AS REQUIRED. DUBAI WATER CANAL
BOLTS SHIM PLATE PLATE TO COL. WELD SAFA A
DUBAI-UAE
ELELVATION SECTION PLAN PLAN Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
TYPICAL STEEL BEAM SPLICES CONNECTIONDETAIL PLOT 02 / 3435336
2 N.T.S. BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
Drawing Title:

STRUCTURAL GENERAL DETAILS -


20

Scale Drawn Checked Approved Size


AA MA NS
1 N.T.S A1
26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-02-02-00-SG0025 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

N12-200 'L' BARS EACH


SIDE OF BLOCKOUT BENT
ONE R10 TIE EXTRA DOWN INTO SLAB AFTER ONE R10 TIE EXTRA
EACH SIDE FOR 2N12 TOP & BOTTOM CONTINUOUS ONE R10 TIE EXTRA 2N12 TOP & BOTTOM CONTINUOUS STRESSING EACH SIDE FOR
4 OR 5 STRANDS 15.2Ø LAP 350, 1000 MINIMUM LENGTH EACH SIDE FOR LAP 350, 1000 MINIMUM LENGTH 4 OR 5 STRANDS 15.2Ø N
10 FOR SINGLE DUCT LOCATIONS 4 OR 5 STRANDS 15.2Ø FOR SINGLE DUCT LOCATIONS KEY PLAN
SECURE END OF DUCT
WITH DENSOTAPE
(TYPICAL)
PLACE INNERMOST BAR
1 2 HARD AGAINST SPACER

300 LAP
---- ---- PLATE AS SHOWN 1

450

400
----

ONIONS TO BE SET OUT


PLACE INNERMOST BAR USING SPACER PLATE
9 HARD AGAINST SPACER MINIMUM SPACING 75mm.
PLATE AS SHOWN
2R10 TIES AT 50mm C/C,
THEN AT 400 C/C. PLACE EXTRA N12 TOP & BOTTOM 2R10 TIES AT 50mm C/C
EXTRA N12 TOP & BOTTOM INNERMOST TIE HARD 2N12 TRIMMERS TOP E/F
FOR 4 & 5 STRANDS 15.2Ø AGAINST CASTING FOR 4 & 5 STARNDS 15.2Ø THEN AT 400 C/C X1500 LONG TYPICAL FOR
ALL PAN STRESSING
General Notes:
POCKETS INCLUDING
POCKETS IN BANDS 1. DO NOT SCALE FROM THIS DRAWING.

TYPICAL LIVE END UNSUPPORTED SLAB EDGE TYPICAL DEAD END UNSUPPORTED SLAB EDGE 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS

01 02 SCALE N.T.S
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
N.T.S
INTERNAL STRESSING SLAB POCKET DETAIL BY THE ENGINEER.
SCALE

01 SCALE N.T.S
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

370
50
450 200
7

30
GROUT TUBE

80
R10 CLOSED TIES SPACER PLATE

140
R10 CLOSED TIES

=
=
=

3N12 TOP & BOTTOM 2R10-50 TIES

=
1000 LONG MINIMUM EACH SIDE
=

200 OR CONTINUOUS 500 LAP


2N12 TOP & BOTTOM 2N12 TOP & BOTTOM WHERE REQUIRED
200 X 1000 MINIMUM
X 1000 MINIMUM
6

SECTION (1) SECTION (2) SECTION (1)


03 SCALE N.T.S 04 SCALE N.T.S 03 SCALE N.T.S

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


AUTHORITY APPROVAL 0 08.08.2017 NS
Purpose of Issue Rev. Date Appoved
Client:

600
5
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:
2N16 AT EACH ANCHOR
1 1 700

200
---- ----

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
PLACE INNERMOST BAR PLACE INNERMOST BAR PO Box 54115 Dubai, UAE
HARD AGAINST ANCHOR HARD AGAINST ANCHOR P: +971 4 3997758 F: +971 4 3997759
4 PLATE AS SHOWN PLATE AS SHOWN Sub-Consultant:

LIVE END AT POUR STRIP DETAIL TYPICAL TENDON COUPLER DETAIL 2N16 1000 LONG AT
01 01 SCALE N.T.S
SCALE N.T.S EACH ANCHOR
200 4N12 T & B,
5N12-60,
6N12-60 FOR 5N16 T & B FOR
125 BEAMS >550D BEAMS >550D
2N12 TOP & BOTTOM Project Name:
SEE PLAN FOR BAR SIZE SEE PLAN FOR BAR SIZES 1000 LONG
5N12 N16-200 U.N.O AT SLAB N16-200 U.N.O AT SLAB REFER TO LIVE
03
TYPICAL DEAD END BEAM DETAIL DUBAI WATER CANAL
40
3 N20-200 U.N.O AT BEAM N20-150 U.N.O AT BEAM END DETAIL U.N.O SCALE N.T.S

(15.2Ø STRANDS) SAFA A


DUBAI-UAE

Project Description:
25

REINFORCEMENT SIMILAR 2R10 TIES AT


MIXED USE DEVELOPMENT
5N12 TO TYPICAL LIVE END DETAIL 50 C/C EACH SIDE (RETAIL & RESIDENTIAL)
1200 NTS 1200 - POUR STRIP 1200 NTS UNLESS NOTED OTHERWISE
PLOT 02 / 3435336
2 SECTION (1) BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
02
SECTION (1)
SCALE N.T.S

02 SCALE N.T.S
Drawing Title:

STRUCTURAL GENERAL DETAILS -


21

Scale Drawn Checked Approved Size


AA MA NS
1 N.T.S A1
26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-02-02-00-SG0026 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

N
10 KEY PLAN
R10 CLOSED TIES ENDS SQUARED BY
N16-250 TOP & BOTTOM 2N12 TOP & BOTTOM
ACROSS JOINT 3000 LONG SPACER PLATE EITHER SIDE BENDING AS SHOWN

1 2
---- ----
1N16 TOP & BOTTOM LIVE OR DEAD ANCHOR
EITHER SIDE OF JOINT EITHER SIDE OF JOINT
9 LAP 450

ENDS SQUARED BY
BENDING AS SHOWN
General Notes:
TYPICAL REINFORCEMENT AT C.J. IN SLAB
02 SCALE N.T.S
1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

ALTERNATIVE LIVE END UNSUPPORTED SLAB EDGE ALTERNATIVE DEAD END UNSUPPORTED SLAB EDGE 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
8 01 SCALE N.T.S 02 SCALE N.T.S
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.
100 350 R10 HELIX OF 6 TURNS 350 50
50
AT 70 PITCH R10 HELIX OF 6 TURNS

110
4N20 TOP & BOTTOM AT 70 PITCH

110
ACROSS JOINT 3000 LONG ROUGHENED SURFACE 290 SPACER PLATE
290

1N16 TOP & BOTTOM LIVE OR DEAD ANCHOR


EITHER SIDE OF JOINT EITHER SIDE OF JOINT 3N12 TOP & BOTTOM CONTINUOUS 3N12 TOP & BOTTOM CONTINUOUS
LAP 450 LAP 350, 1000 MINIMUM LONG FOR LAP 350, 1000 MINIMUM LONG FOR
SINGLE DUCT LOCATIONS SINGLE DUCT LOCATIONS

SECTION (1)
TYPICAL REINFORCEMENT AT C.J. IN BEAMS OR THICKENING 03 SCALE N.T.S SECTION (2)
04 SCALE N.T.S 04 SCALE N.T.S

100 50 2N20 AT EACH ANCHOR


1400 200 400 600 400 200
100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
200

AUTHORITY APPROVAL 0 08.08.2017 NS


Purpose of Issue Rev. Date Appoved
Client:

3 1 2 4

200
5
2N16 1000 LONG MEYDAN L.L.C

VARIES
AT EACH ANCHOR P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
200 E: info@dubairacingclub.com W: www.dubairacingclub.com

4N12 T & B, 5N12-60, Principal Consultant:


5N16 T & B FOR 6N12-60 FOR
BEAM >550D BEAMS >550D
TYPICAL LIVE END BEAM DETAIL
04 SCALE N.T.S
1800
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com
(15.2Ø STRANDS) Hassanicor Building, 6th Floor, Al Barsha 1

STRESSING DETAILS IN SLAB BANDS (FOR 15.2mm MONO-STRANDS U.N.O.) PO Box 54115 Dubai, UAE
4 01 SCALE N.T.S
Sub-Consultant:
P: +971 4 3997758 F: +971 4 3997759

NUMBER & COMBINATION OF ANCHORS MAY VARY ( 1 SIGNIFIES ORDER OF STRESSING)


2N16
4N12 T & B, 700
5N16 T & B FOR 200 350 350 350 350 200
200

BEAMS >550D

Project Name:

3 4 2 1 3 5 DUBAI WATER CANAL

200
50 200 2N16 SAFA A
5N12-60 800 LONG

VARIES
DUBAI-UAE

TYPICAL LIVE END BEAM DETAIL AT STRESSING POCKET Project Description:


05
MIXED USE DEVELOPMENT
SCALE N.T.S

(15.2Ø STRANDS)
1800 (RETAIL & RESIDENTIAL)
PLOT 02 / 3435336
2 STRESSING DETAILS IN SLAB BANDS WITH 5 TENDONS (FOR 15.2mm MONO-STRANDS U.N.O.) BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
02 SCALE N.T.S

NUMBER & COMBINATION OF ANCHORS MAY VARY ( 1 SIGNIFIES ORDER OF STRESSING) Drawing Title:

STRUCTURAL GENERAL DETAILS -


22

Scale Drawn Checked Approved Size


AA MA NS
1 N.T.S A1
26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-02-02-00-SG0027 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


N
11

N
10 KEY PLAN

E= 491152.343
N= 2787081.093
E= 491068.889
N= 2787135.481

3.01 3.02 3.03 3.04 3.05 3.06 3.07 3.08 3.09 3.10 3.11 3.12 3.13 01 3.24 4.01 4.02 4.03 4.04 4.05 4.06 4.07 4.08 4.09 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17
PLOT LIMIT 9500 2200 9500 7750 8200 8200 8200 8200 5650 9500 9500 10500 9400 10500 8200 1200 2300 4700 4800 3400 8200 9900 8200 4100 3400 700 8200 600 2200 9500 8965
9 2200

E= 491248.550
N= 2787019.862
3.A
EXCAVATION LIMIT 4.A PLOT LIMIT

1750
4.B
General Notes:
8200

EXCAVATION LIMIT EXCAVATION LIMIT 1. DO NOT SCALE FROM THIS DRAWING.

8200
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
3.B NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.
4.C
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
8200

SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK


8 AT SITE.

8200
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
3.C ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.
4.D
8200

8200
EXCAVATION LIMIT
3.D

4.E
8200

4100
7 4.F
3.E

5600
4.G
8200

2200
4.H

3.F
8200

9500
3.G
EXCAVATION LIMIT
6 4.J
3.H
9500

PLOT LIMIT

E= 491184.840 E= 491203.414 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


3.I E= 491221.602
E= 491165.989 N= 2786999.955 N= 2786989.017
2150

N= 2786977.499 AUTHORITY APPROVAL 0 08.08.2017 NS


E= 491146.766 N= 2787010.299
3.J Purpose of Issue Date Appoved
N= 2787020.054 Rev.
E= 491127.293
N= 2787029.171 Client:
12300
9550

8200 3.23
8200
8200 3.22
8200 3.21
5 8200 3.20
3.K EXCAVATION LIMIT 8200 3.19 E= 491099.926 MEYDAN L.L.C
8200 3.18 N= 2787041.144 P.O. Box 9305, Dubai , UAE.
E= 491029.426 12300 3.17 T: +9714 3270000 F: +9714 3270007
N= 2787073.205 PLOT LIMIT 3.16 E= 491081.736 E: info@dubairacingclub.com W: www.dubairacingclub.com
E= 491043.270 E= 491050.450 E= 491072.230
3.15 N= 2787048.495
N= 2787065.401 N= 2787061.901 N= 2787052.337
3.14
Principal Consultant:
E= 491057.555
N= 2787058.437

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
Sub-Consultant:

Project Name:

3
DUBAI WATER CANAL
SAFA A
DUBAI-UAE

Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
PLOT 02 / 3435336
2 -1.525 DMD +1.325 DMD BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
Drawing Title:
-2.625 DMD +1.475 DMD

-3.025 DMD +1.675 DMD


EXCAVATION PLAN
-4.025 DMD +1.775 DMD

-4.825 DMD +2.275 DMD


Scale Drawn Checked Approved Size
AA MA NS
1 +1.075 DMD +2.975 DMD 1 : 350 A1
EXCAVATION PLAN 26.05.2016 24.08.2017 24.08.2017
1 SCALE 1 : 350 Drawing Number Rev.

14011603-02-00-SE0100 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


N
11

N
10 KEY PLAN

E= 491152.343
9 1 1 N= 2787081.093 1 1
E= 491068.889
N= 2787135.481 SP0999b SP0999a SP0999c SP0999b
3.01 3.02 3.03 3.04 3.05 3.06 3.07 3.08 3.09 3.10 3.11 3.12 3.13 01 3.24 4.01 4.02 4.03 4.04 4.05 4.06 4.07 4.08 4.09 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17
PLOT LIMIT
9500 2200 9500 7750 8200 8200 8200 8200 5650 9500 2200 9500 10500 9400 10500 8200 12002300 9500 3400 8200 9900 8200 4100 3400 700 8200 600 9500
2200
E= 491248.550
N= 2787019.862
General Notes:
3.A 1. DO NOT SCALE FROM THIS DRAWING.
4.A PLOT LIMIT

1750
4.B 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
8200

BY THE ENGINEER.

8200
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 3.B AT SITE.

4.C 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
8200

AND RELEVANT SECTIONS OF THE SPECIFICATION.

8200
3.C

4.D
8200

8200
3.D
7
4.E
8200

4100
4.F
3.E

5600
4.G
8200

2200
4.H

3.F

9500
8200

3.G

4.J
3.H 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
9500

AUTHORITY APPROVAL 0 08.08.2017 NS


PLOT LIMIT
Purpose of Issue Rev. Date Appoved
E= 491184.840 E= 491203.414 E= 491221.602 Client:
3.I E= 491165.989 N= 2786999.955 N= 2786989.017
2150

N= 2786977.499
E= 491146.766 N= 2787010.299
3.J
N= 2787020.054
E= 491127.293
5 N= 2787029.171
12300
MEYDAN L.L.C
9550

8200 3.23
8200 P.O. Box 9305, Dubai , UAE.
8200 3.22 T: +9714 3270000 F: +9714 3270007
8200 3.21 E: info@dubairacingclub.com W: www.dubairacingclub.com
3.20
3.K 8200 E= 491099.926 Principal Consultant:
8200 3.19
8200 3.18 N= 2787041.144
E= 491029.426 3.17
N= 2787073.205 PLOT LIMIT 12300 3.16 E= 491081.736
E= 491043.270 E= 491072.230
E= 491050.450 3.15 N= 2787048.495
N= 2787065.401 N= 2787052.337
3.14 N= 2787061.901
E= 491057.555 abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
N= 2787058.437 www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
Sub-Consultant:

Project Name:

3
DUBAI WATER CANAL
SAFA A
DUBAI-UAE

Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
PLOT 02 / 3435336
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
Drawing Title:

LEGEND: BASEMENT 01 LEVEL - FRAMING &


R.C. COLUMN PILE CAPS PLAN - OVERALL
R.C. WALL
PLANTED COLUMN / WALL
Scale Drawn Checked Approved Size
NOTE: AA MA NS
1 1. FOR COLUMNS & WALLS SCHEDULES REFER TO EACH BUIDLING SHEETS 1 : 350 A1
2. FOR CORE WALL DETAILS REFER TO EACH BUILDING SHEETS 08.06.2017 24.08.2017 24.08.2017
BASEMENT 01 LEVEL - FRAMING & PILE CAPS PLAN - OVERALL 3. FOR FAOUNDATION DETAILS REFER TO DWG. 00-S5101 TO DWG. 00-S5109

1
4. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 TO DWG. 00-S5507 Drawing Number Rev.
5. FOR RAMP DETAILS REFER TO DWG. 00-S5601 TO DWG. 00-S5602
SCALE 1 : 350 6. FOR WATER TANK DETAILS REFER TO DWG. 00-S5901
7. FOR EARTH PITS LOCATION REFER TO ELECTRICAL DRAWINGS 14011603-02-00-SP0999 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

1
DUBAI MUNICIPALITY STAMP:
SP0999b
3.01 3.02 3.03 3.04 3.05 3.06 3.07 3.08 3.09 3.10 3.11 3.12 N
PLOT LIMIT
11

PLOT LIMIT
Q
9500 2200 9500 7750 8200 8200 8200 8200 5650 9500 2200

3.A
600X600X400mm 2 2 2
DRAIN PIT S5106 S5106 S5106

2600

2600

2600

2600

2600

2600

2600

2600

2600
600X600X300mm
1500 DRAIN PIT

N
10 KEY PLAN

400

1500

1500

1500

1500

1500

1500

1800
3700
8200

PC3 150 PC3 PC3 750 PC3 PC3 PC3 PC3 1350 PC3 PC29
750 750 750 750
1 300
5 S5107

4250
1100
S5107
OPEINING 800X600 AT 750 750 750 750 750 A
1500 2200 2400
LEVEL -2.500 SSL
1

750
3.B

400

400

400

400

400
S5107

750

750
PC1

900
1400
PC14 PC1 PC1 PC1 PC1 PC1
PC3 PC5 PC5

90
1260
9 TRENCH
1000X300X300
8200

500mm FOUNDATION SLAB


General Notes:
-4.500 SSL
1150 300 1. DO NOT SCALE FROM THIS DRAWING.
750 750 750 750 750 2400
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS

900
800 NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
3.C BY THE ENGINEER.

750

750

750

750

750

750

900
PC3 PC1 PC1 PC1 PC1 PC1 PC6 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
PC5
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

1150 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
500mm FOUNDATION SLAB AND RELEVANT SECTIONS OF THE SPECIFICATION.
8200

PC3 PC15 -4.500 SSL


2500

750 750 750 750 750


1150 2400 300
750

3.D

400

400

400

400

400

750
1850

900

900
PC1 PC1 PC1 PC1 PC1
7 PC3 PC5 PC2
6200 300

RAMP 1
RAMP 1
PC1
8200

150
250 200
200 750 750
750

800
750

3.E
6

850
900

PC1
PC3 PC2 PC1 PC1 PC6 PC1
750 PC1
1150 2780

955
2000
750

4510

3000
1965 600X600X600mm
100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS

2500
DRAIN PIT
AUTHORITY APPROVAL 0 08.08.2017 NS
TRENCH

2500
8200

800
3650x300x300 PC5 Purpose of Issue Rev. Date Appoved

900
TRENCH 7190

2500
3450X300X300 PC5 Client:
2200
2450

-6.300 SSL
1650

PC5
2800

2800
2850

PC23

900
2000 ST3-02 PC5
5 3.F
-
MEYDAN L.L.C
750 P.O. Box 9305, Dubai , UAE.
2000

750 T: +9714 3270000 F: +9714 3270007


SUMP PIT
-4.500 SSL 2000x2000x2500 E: info@dubairacingclub.com W: www.dubairacingclub.com
700
750 900 Principal Consultant:
8200

-6.300 SSL
PC1
2800

2600

1350 400
3200
600X600X600mm 900
3.G DRAIN PIT
900
L
-7.000 SS
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
PC5 www.ae-7.com
PC9
2000

425
-4.500 SSL PC25 750 PC13 Hassanicor Building, 6th Floor, Al Barsha 1

400 550
775 PO Box 54115 Dubai, UAE
PC5 PC2 P: +971 4 3997758 F: +971 4 3997759
4 725
450

750 PC2 Sub-Consultant:


800 400

3.H
PC1
PC1
9500

1350

900
900
2880

100

PC1
750
50

1150
PC5
2
PC2
50

S5106 900
PC3 PC9 Project Name:
925 900
3.I PC5
11780

PC2
DUBAI WATER CANAL
2150

3 875 750

600
AB
NDATION SL SAFA A
500mm FOU

1300
3.J PC2 750 PC3

240
L
750 -4.500 SS 900

1300 605
PC9
DUBAI-UAE

330
780 PC3
1050 885

900 PC9
750 PC3 Project Description:
1050 1165

PC2
1
1150 PC3 S5106 MIXED USE DEVELOPMENT
1300

750
PC5
(RETAIL & RESIDENTIAL)
9550

1500

PC9 750 8200


1400

PC3
500 1600

3.22 PLOT 02 / 3435336


1050

PC3 PLOT LIMIT 8200


750 PC3 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
2 3.21
2325

1 8200
1495

1450 750
PC3 S5106 3.20
Drawing Title:
8200
PC3 3.19
LEGEND:
1880

3.K
PC12 8200
3.18
R.C. COLUMN
BASEMENT 01 LEVEL - FRAMING &
8200
S5106
1
8200
3.17
R.C. WALL
PILE CAPS PLAN - PART A
3.16
12300 PLANTED COLUMN / WALL
3.15
Scale Drawn Checked Approved Size
PLOT LIMIT NOTE: AA MA NS
1 3.14 1 : 150 A1
1. FOR COLUMNS & WALLS SCHEDULES REFER TO EACH BUIDLING SHEETS
2. FOR CORE WALL DETAILS REFER TO EACH BUILDING SHEETS
26.05.2016 24.08.2017 24.08.2017
3. FOR FAOUNDATION DETAILS REFER TO DWG. 00-S5101 TO DWG. 00-S5109
BASEMENT 01 LEVEL - FRAMING & PILE CAPS PLAN - PART A 4. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 TO DWG. 00-S5507 Drawing Number Rev.
1 SCALE 1 : 150
5. FOR RAMP DETAILS REFER TO DWG. 00-S5601 TO DWG. 00-S5602
6. FOR WATER TANK DETAILS REFER TO DWG. 00-S5901 14011603-02-00-SP0999a 0
7. FOR EARTH PIT LOCATIONS REFER TO ELECTRICAL DRAWINGS

All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

1
1
SP0999c
DUBAI MUNICIPALITY STAMP:
SP0999a
3.10 3.11 3.12 3.13 01 3.24 4.01 4.02 4.03 4.04 4.05 4.06 4.07
N
11

9500 2200 9500 10500 9400 10500 8200 1200 2300 4700 4800 3400
Q

PLOT LIMIT

3.A
2 2 4.A
S5106 S5106

2600

2600

2600

2600

2600

1750
4.B
N
10 KEY PLAN

1500

1500

1500
1800

1800
PC3
8200

1350 PC3 PC29 PC3 1350 PC29


300 2300 1450

1100

8200
2400 450

750
3.B

750
PC10
B
PC5 PC5
2 4.C
9 660 S5106
8200

500mm FOUNDATION SLAB ST3-03


- General Notes:

4825
-4.500 SSL

8200
300
1. DO NOT SCALE FROM THIS DRAWING.
2400 2450
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
3.C BY THE ENGINEER.
900

PC5 PC6 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


-6.300 SSL SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.
4.D

5475
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
600X600X600mm ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
DRAIN PIT AND RELEVANT SECTIONS OF THE SPECIFICATION.
8200

1550 PC24
2 2 2

8200
2400 300 1500 S5106 S5106 S5106
-4.500 SSL 50

300

450
3.D 750

750
900

900

PC5 PC2 PC2 PC1

300 1500

300 1500
300 1500
7 PC3 1050
1650
PC7 4.E PC3 PC29 PC30
760 250 PC3 770 PC30
550

2300
250 PC19
6
8200

4100
S5108 S5507 925
ESCALATOR PIT
PC5 PC10

1000
4250x1650x1100 -5.600 SSL

925
150
200 1500 200750 4.F

1300
750 750
725
925
800

750
3.E
825
850

900

900

5600
PC6 PC1 PC2 PC1
PC6 500mm FOUNDATION SLAB
PC10 PC10
700 -4.500 SSL 750 PC1 PC10
PC1
750

700 750
200 1500
600X600X600mm 760

1750

1650
750 PC10 0
900 100% CONSTRUCTION DOCUMENTS FOR TENDER 24.08.2017 NS

1120
DRAIN PIT
3.G
4.G AUTHORITY APPROVAL 0 08.08.2017 NS
8200

2200 Purpose of Issue Rev. Date Appoved

PC10 PC4 PC2 PC4 Client:

300
-6.300 SSL 4.H PC10 PC5

150

500
600
1500 1800
PC23
945

5 3.F
MEYDAN L.L.C
950

PC16
PC6 P.O. Box 9305, Dubai , UAE.
9500

725
235

T: +9714 3270000 F: +9714 3270007


1830 775 E: info@dubairacingclub.com W: www.dubairacingclub.com
4500
9500

900 500mm FOUNDATION SLAB Principal Consultant:


900 900 900
8200

750 -4.500 SSL 750


1500 75

PC10
425

3.I PC1
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
PC4
2150

PC9 PC2 PC2 PC6 www.ae-7.com


425

Hassanicor Building, 6th Floor, Al Barsha 1

1600

1600

1600
PC10 PC10

1000
PO Box 54115 Dubai, UAE
3.J 1
450

450

P: +971 4 3997758 F: +971 4 3997759


4 4.J
S5106 780 715 Sub-Consultant:
3.H
1
500 805 690
740

S5106 805 690


3230

1200
TRENCH PC3
2330

1200
2400X300X300 830 665 PC3
4650

1200
750 PC3
830 665

1200
PC3
9550

820 675
PC17
1200

900 PC3
1200

900 PC3 Project Name:


PC1
130
1455 215

PC5
PC2
3 750
4650 PC29 DUBAI WATER CANAL
600

PC3 PLOT LIMIT SAFA A


1300

750 PC3
240

3.K DUBAI-UAE
PC3

Project Description:

12300 MIXED USE DEVELOPMENT


8200
(RETAIL & RESIDENTIAL)
3.23
PLOT 02 / 3435336
2 3.22
BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
3.21 Drawing Title:
LEGEND:
R.C. COLUMN BASEMENT 01 LEVEL - FRAMING &
R.C. WALL PILE CAPS PLAN - PART B
PLANTED COLUMN / WALL

NOTE: Scale Drawn Checked Approved Size


1. FOR COLUMNS & WALLS SCHEDULES REFER TO EACH BUIDLING SHEETS
AA MA NS
1 2. FOR CORE WALL DETAILS REFER TO EACH BUILDING SHEETS 1 : 150 A1
3. FOR FAOUNDATION DETAILS REFER TO DWG. 00-S5101 TO DWG. 00-S5109 26.05.2016 24.08.2017 24.08.2017
BASEMENT 01 LEVEL - FRAMING & PILE CAPS PLAN - PART B 4. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 TO DWG. 00-S5507
1 5. FOR RAMP DETAILS REFER TO DWG. 00-S5601 TO DWG. 00-S5602
6. FOR WATER TANK DETAILS REFER TO DWG. 00-S5901
Drawing Number Rev.
SCALE 1 : 150 7. FOR EARTH PIT LOCATIONS REFER TO ELECTRICAL DRAWINGS 14011603-02-00-SP0999b 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


N
11

1
SP0999b

4.05 4.06 4.07 4.08 4.09 4.10 4.11 4.12 4.13 4.15 4.16 4.17

N
10 4800 3400 8200 9900 8200 4100 3400 700 8200 600 2200 9500 KEY PLAN

PLOT LIMIT
4.A
PLOT LIMIT

4.B

9 WALL REINFORCEMENT SAME


AS REINFORCEMENT AS PER
WALL IN SECTION 1/S5107
__
___
_3__
8200

S5901 1
150
S5108 General Notes:
2400

750

750
1150 PC3 1. DO NOT SCALE FROM THIS DRAWING.
1150 PC3
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
4.C NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED

750

750
PC20 600X600X300mm BY THE ENGINEER.
PC1 DRAIN PIT PC4
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
OPEINING 800X600 4 SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT LEVEL -1.350 SSL S5107 AT SITE.
750
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
8200

1500
AND RELEVANT SECTIONS OF THE SPECIFICATION.

PC27 PC3 2
600X600X400mm
2
1 S5108
DRAIN PIT

2510
S5107
S5107 2350 1150
300 1300
ST4-03
-

775

1500
4.D

PC2 600X600X300mm PC3

1170
7 600X600X400mm DRAIN PIT
DRAIN PIT
OPEINING 800X600
AT LEVEL -1.700 SSL

2 2 __
___
_1__ 600X600X300mm 4.14
OPEINING 800X600
AT LEVEL -1.350 SSL
8200

S5901
DRAIN PIT
S5106 S5106
600 600 2200 3795 TRENCH 3
600X600X300mm 600X600X400mm
600X600X600mm 200 DRAIN PIT 975 2400X300X300 S5106
DRAIN PIT DRAIN PIT 1775 250

1150

1670
1050

900
850

745 755
PC3

300

300
250

250
4.E PC30 PC1 PC1
1340

300
PC30 -6.300 SSL PC10
6 ST4-02
2300

PC19 PC19 - PC18 RAMP 2 PC3


3 975
4100

S5107 TRENCH
925 175 350mm. THICK C.I.P SLAB 2400X300X300 1150

2550
1950 1110
PC21 1340 150 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS

750 750
725
0 NS

225

225
4.F AUTHORITY APPROVAL 08.08.2017

90
4

925
725 PC8
Purpose of Issue Rev. Date Appoved
S5105 PC10 PC3
3150 950 PC1 2250
750 PC1 3 Client:
650
S5107
5600

SUMP PIT -7.000 SSL


PC10 PC2 PC2 750
5 PC1 775 2000x2000x2500 225
750
MEYDAN L.L.C
700 750

1150
150 1450
1650

1600

900 925 900 125 PC22

1200
725 PC4

1000
P.O. Box 9305, Dubai , UAE.

450

1275 225
4.G T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com
PC19 PC3
2200

Principal Consultant:

490
PC2 PC4 PC4 PC2
300

300
4.H PC4 PC8 PC10 1785 2615

150
575
600

TRENCH TRENCH
4350X300X300 4350X300X300
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
500mm FOUNDATION SLAB PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4 500mm FOUNDATION SLAB -4.500 SSL
775 125 825 Sub-Consultant:
9500

-4.500 SSL 2625


925
900 900 900 1150
900
2
S5106

PC10 PC8 PC5 PC1 PC9 PC3


PC2 PC6 PC2 PC2
1

2075

2395
1600

1600

260 1600

195 1600

1575
1450

1450

165 2640 735

1000
750
S5106 1450
4.J
1 780 715 55
780 715 Project Name:
S5106 780 715

1200

1200

1500
1200
1200

PC3 PC3 PC3


805 690 PC3 PC3
DUBAI WATER CANAL
1200

PC3 PC3
1200

3 PC3
1200

PC3 PC30 SAFA A


PLOT LIMIT
DUBAI-UAE
PLOT LIMIT

Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
PLOT 02 / 3435336
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
Drawing Title:
LEGEND:
R.C. COLUMN
BASEMENT 01 LEVEL - FRAMING &
R.C. WALL
PILE CAPS PLAN - PART C
PLANTED COLUMN / WALL
Scale Drawn Checked Approved Size
NOTE: AA MA NS
1 1. FOR COLUMNS & WALLS SCHEDULES REFER TO EACH BUIDLING SHEETS 1 : 150 A1
2. FOR CORE WALL DETAILS REFER TO EACH BUILDING SHEETS 26.05.2016 24.08.2017 24.08.2017
BASEMENT 01 LEVEL - FRAMING & PILE CAPS PLAN - PART C 3. FOR FAOUNDATION DETAILS REFER TO DWG. 00-S5101 TO DWG. 00-S5109

1 4. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 TO DWG. 00-S5507


5. FOR RAMP DETAILS REFER TO DWG. 00-S5601 TO DWG. 00-S5602
Drawing Number Rev.
SCALE 1 : 150 6. FOR WATER TANK DETAILS REFER TO DWG. 00-S5901
7. FOR EARTH PIT LOCATIONS REFER TO ELECTRICAL DRAWINGS
14011603-02-00-SP0999c 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


N
11

N
10 KEY PLAN

1 1 1 1
SC0999b SC0999a SC0999c SC0999b General Notes:
3.01 3.02 3.03 3.04 3.05 3.06 3.07 3.08 3.09 3.10 3.11 3.12 3.13 01 3.24 4.01 4.02 4.03 4.04 4.05 4.06 4.07 4.08 4.09 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17
1. DO NOT SCALE FROM THIS DRAWING.
PLOT LIMIT
9500 2200 9500 7750 8200 8200 8200 8200 5650 9500 2200 9500 10500 9400 10500 8200 1200 4700 4800 3400 8200 9900 8200 4100 3400 700 8200 600 9500
2300 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
2200 NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.
3.A
4.A PLOT LIMIT 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
4.B SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.
8200

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT

8200
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.
3.B

4.C
8200

8200
3.C

4.D
8200

8200
3.D

4.E
8200

4100
4.F
3.E

5600
4.G
8200

2200
6
4.H

3.F

9500
8200

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


3.G AUTHORITY APPROVAL 0 08.08.2017 NS
Purpose of Issue Rev. Date Appoved
4.J
3.H Client:
9500

PLOT LIMIT

5 3.I
2150

3.J
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com
12300
9550

Principal Consultant:
8200 3.23
8200
8200 3.22
8200 3.21
8200 3.20
3.K 3.19
8200 abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
8200 3.18
3.17 www.ae-7.com
12300 3.16 Hassanicor Building, 6th Floor, Al Barsha 1
PLOT LIMIT
3.15 PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4 3.14
Sub-Consultant:

Project Name:

3
DUBAI WATER CANAL
SAFA A
DUBAI-UAE

Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
PLOT 02 / 3435336
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
Drawing Title:

BASEMENT 01 LEVEL - COLUMNS &


WALLS SETTING OUT PLAN -
OVERALL
LEGEND:
R.C. COLUMN Scale Drawn Checked Approved Size
R.C. WALL AA MA NS
1 1 : 350 A1
PLANTED COLUMN / WALL 26.05.2016 24.08.2017 24.08.2017
BASEMENT 01 LEVEL- COLUMNS & WALLS SETTING OUT PLAN - OVERALL NOTE:
1
Drawing Number Rev.
SCALE 1 : 350
1. FOR COLUMNS & WALLS SCHEDULES REFER TO EACH BUIDLING SHEETS
2. FOR CORE WALL DETAILS REFER TO EACH BUILDING SHEETS 14011603-02-00-SC0999 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


3.01 3.02 3.03 3.04 3.05 3.06 3.07 3.08 3.09 3.10 1 3.11 3.12

PLOT LIMIT SC0999b N


9500 2200 9500 7750 8200 8200 8200 8200 5650 9500 2200
11
PLOT LIMIT
Q

5655
3.A

2600
2200

N
10 KEY PLAN

350
8200

2600 500 350 3250 350


350

4275
150 150 150 150 150 150 150 150 150 150
A
1400 1200

225 350
350 850 1200

250 950
250 950
250 950

175

200 200
250 950

250950
175 175
3C17

175 175
3C17 3C17 3C17 3C17
3.B

350
3C15 3C1 3C6

175
3C4

775
350
9
8200

General Notes:
350 850
150 150 150 150 150 150 150 150 150 150 1. DO NOT SCALE FROM THIS DRAWING.
300 900 1400 1200

225

125 225

175 175

175 175
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS

1200

1200

1200

1200

1200
3.C NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
3C4 3C15 3C17 3C17 3C17 3C17 3C17 3C1 3C4
125
BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
8200

8075
AND RELEVANT SECTIONS OF THE SPECIFICATION.

150 150 150 150 150 150 150 150 150 150
350 850
1200 1400 1200

250 950
250 950

250 950
175

250 950

250 950
3C17

175 175
3C17 3C17 3C17 3C17

175 175

175 175
3.D
920

920
3C4 3C15 3C1 3C4
175

4955
2675

00
7 37
3980
4875

00
385

75
9
2205

60
8200

750
66

800
00

313
38

0 0
760
350 850
31

1100 100 300 150 150 150150


44

1400 313 1400 1200


0 8050
175

125 225
706

125 225
3C1 3C17

300
3C17 3C17 3C17
175

1200

1200
3.E

1200
2

3C4 68 3C1 3C14


175
175

95
6 474 350
5

2105
48
50

175 175

1200
365 930

4150
5 3C13

4650
0

175 175
80

3C12

100 1400
109 35 7560 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
12

38
8200

0
175 175 AUTHORITY APPROVAL 0 08.08.2017 NS

100 1400
3C12
13
96 Purpose of Issue Rev. Date Appoved
150 250
__
___
_1__

100 1400
3C12
60

Client:
88

3CW3
100 1400

03-S5204
3C11

0
00

3.F 080
67
365

5 1
10505
MEYDAN L.L.C
__
___
_1__ 200 200
175 175 P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
03-S5202 3C4 E: info@dubairacingclub.com W: www.dubairacingclub.com

1200
550
8200

990 Principal Consultant:


250 150

1400
3C9
200 200

1500
3CW2
200 200

1200
3.G 3C10
200 200

1500

250 1200
3C6

1400
200 200 3C9
175 175

250 1200
3C6 abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com
175 175 3C8
1200

175 225
1500

250 1200
3C4 Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
1200

3C24 P: +971 4 3997758 F: +971 4 3997759

1200
4 225 175 3C5
3.H Sub-Consultant:
175 175
250 1200

3C5
9500

175 175
250 1200

3C4
150 150
250 1200

3C4
150 150
150 1850

3W4

175 175 3W2

1600
175 175 Project Name:

1400
3.I

1500
175 225 3C3
DUBAI WATER CANAL
2150

1400
3C3

1500
3
225 175 3C2 SAFA A
1400
3.J

1500
175 175
1400

3C2
DUBAI-UAE
1500

175 175
1400

3C1

1700
1500

150 150
3C1 Project Description:
1400

1500

1700
MIXED USE DEVELOPMENT
1600

3W1
1500

8200
9550

3.22 (RETAIL & RESIDENTIAL)


1500

8200
PLOT LIMIT 3.21 PLOT 02 / 3435336
8200 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
2 3.20
8200
3.19 Drawing Title:
2730

8200
3.18
BASEMENT 01 LEVEL - COLUMNS &
1700

3.K 8200
WALLS SETTING OUT PLAN - PART
1700

3.17
8200
3.16
LEGEND:
12300 3.15 R.C. COLUMN
A
R.C. WALL Scale Drawn Checked Approved Size
PLOT LIMIT
3.14 AA NS
MA
PLANTED COLUMN / WALL 1 : 150 A1
1
26.05.2016 24.08.2017 24.08.2017
NOTE:
Drawing Number Rev.
BASEMENT 01 LEVEL- COLUMNS & WALLS SETTING OUT PLAN - PART A 1. FOR COLUMNS & WALLS SCHEDULES REFER TO EACH BUIDLING SHEETS

14011603-02-00-SC0999a
1 SCALE 1 : 150
2. FOR CORE WALL DETAILS REFER TO EACH BUILDING SHEETS
0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


1 N
3.10 1 3.11 3.12 3.13 01 3.24 4.01 4.02 4.03 4.04 4.05 4.06 4.07
SC0999c
SC0999a
11
9500 2200 9500 10500 9400 10500 8200 1200 2300 4700 4800 3400

PLOT LIMIT

3.A
4.A

3640
2600

1750
3150
4.B
N
10 KEY PLAN
8200

8200
1400 1200 1600
175

200 200

150 150
3.B
B
__
___
_1__
3C1 3C6 3W6
175

03-S5205
9 4.C
8200

General Notes:
3CW4

8200
1. DO NOT SCALE FROM THIS DRAWING.

1400 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


1200 1200
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
175 175

175 175

125 175
3.C BY THE ENGINEER.
3C1 3C4 3C16
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.
4.D
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.
8200

6400
8200
1400 1200 1200 1400
175 175

175 175
175 175

175 175

3.D 1200 225 175

350
350
3C1 3C4 3C4 3C1
7

50
4C13

1450
4W17
4.E

2900 1600
8200

4100

1600 300
1500 350
4W1 4W5

4.F

1850
1400 1200 1200 1400 500 150 150 140 160
125 225

175 175

175 175

225 175
125 225

3.E 350
500

6 4C24 175 175


3C1 3C14 3C4 3C3 4C22

1400

1400
4C22

5600
4W3

1800
350

1400
4C4 4C15

1200
1200

2350
0 NS

1800

1800

1800
3C13 100% CONSTRUCTION DOCUMENTS FOR TENDER 24.08.2017
3.G 150 150 150 150 275 175 200 200 175 175 175 175 AUTHORITY APPROVAL 0 08.08.2017 NS
4.G
Purpose of Issue Rev. Date Appoved
8200

4C16

600 1200

600 1200

600 1200
4C14 4C16
2200

400 1400

400 1400

400 1400
4C22 4C22 4C1

3CW3
__
___
_1__ 4.H
Client:
03-S5204

1200 1900
5
125 175
225 125

50 1900
3.F
3W5
MEYDAN L.L.C
9500

3C4
300

P.O. Box 9305, Dubai , UAE.


4W16 T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com
175 225 Principal Consultant:
9500

175 225
200 1250

3C7
175 175
8200

200 200 175 175 175 175


150 150 140 160

1800
4W2
250 1200

4C5

1400

1400

1400
3.I 3C6 4C5 4C5
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
1600

1600 www.ae-7.com
2150

4W15 4W15
Hassanicor Building, 6th Floor, Al Barsha 1

1800

1800

1800

1800
PO Box 54115 Dubai, UAE
900

900

P: +971 4 3997758 F: +971 4 3997759


4 3.J
4.J
Sub-Consultant:
3.H
1490

300
225 225
1200
1900

4C23

1700
9550

150 150
3W3
175 175 3W2
1600

1495

Project Name:
1700
1400

DUBAI WATER CANAL


1500

3 3C3
SAFA A
1500

PLOT LIMIT

3.K
DUBAI-UAE
1700

Project Description:

12300 MIXED USE DEVELOPMENT


8200
(RETAIL & RESIDENTIAL)
3.23 PLOT 02 / 3435336
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
3.22

3.21
Drawing Title:

BASEMENT 01 LEVEL - COLUMNS &


LEGEND:
WALLS SETTING OUT PLAN - PART
R.C. COLUMN
B
R.C. WALL Scale Drawn Checked Approved Size
AA MA NS
1 PLANTED COLUMN / WALL 1 : 150 A1
26.05.2016 24.08.2017 24.08.2017
BASEMENT 01 LEVEL- COLUMNS & WALLS SETTING OUT PLAN - PART B NOTE:
1
Drawing Number Rev.
1. FOR COLUMNS & WALLS SCHEDULES REFER TO EACH BUIDLING SHEETS
SCALE 1 : 150 2. FOR CORE WALL DETAILS REFER TO EACH BUILDING SHEETS
14011603-02-00-SC0999b 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


N
11
1
SC0999b Q
4.05 4.06 4.07 4.08 4.09 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17

4800 3400 8200 9900 8200 4100 3400 700 8200 600 9500

2200

N
10 KEY PLAN
PLOT LIMIT
4.A
375 PLOT LIMIT

4.B

5085
750 C
8200

350 350 6200 350 350 750


9 50
50
1350
350 1200 350 1400 350 900 350 350
50 50 50

General Notes:

1500
1200 1400

350
4C16

175 175
750
175 175
175 175
4.C

350
4C6 1. DO NOT SCALE FROM THIS DRAWING.
1200 4C17
° 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
32 NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED

3925
3925
.4

2950
91 BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES

350
350 350
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8
8200

450

350
AT SITE.
540
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT

__
___
_1__ ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

2950
4CW2
04-S5202
1200 1200

350 350

175 175

125 175

1785 125
450
4.D
4C16 4C19
7950 350 1235 350 7010

350
6400
7

5825
8200

225 175 225 175

350
350

1050 350
1450

700 1100 2150


4W17
__
___
_1__

1800

400 1050

200 250
150 150

250 200
4.E
04-S5203 4W18
__
___
_12__
4CW3 4W17 4W8

13875
04-S5203

4100
4100

350 1950 350 225 2525 250 1850 250 1700 350

88
6 275 350 50 4CW5

.5
68
1400 2000

°
175 125

225 175
350 350
4.F
4C9 4W7
100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
175 175
225 175
350 125 225
225 175
__
___
_7__ AUTHORITY APPROVAL 0 08.08.2017 NS
04-S5203
Purpose of Issue Rev. Date Appoved
5600

4W3 4CW4
1800

1800
4W3
1400

1400

4C15 4C8 4C8 6035 3155 350


1200

Client:
3155
1800

1800

1800

1800

1800

300 300 1705


175 125 6675 1900
175 175 175 175 125 175

4
4.G 125 175 175 175 175 175

323
5
4C16 4C11 MEYDAN L.L.C
600 1200

600 1200

600 1200
4C16 4C16
450 1350

4W9
2200

400 1400

400 1400

400 1400
4C11 4C11 4C12
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
4.H E: info@dubairacingclub.com W: www.dubairacingclub.com
?
Principal Consultant:

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
9500

125 275
PO Box 54115 Dubai, UAE
125 175 125 175 175 125 P: +971 4 3997758 F: +971 4 3997759
4 175 175 175 175 200 200 200 200
4W8 4W6 Sub-Consultant:

2050
1800

1800

1800
4C5 4W4 4W4
1400

1400

1400

1400

4C5 4C2 4C2


1800

1800

1800

1800

1800

1800

1800

1800
4.J

Project Name:

1700
1700

1700
3
PLOT LIMIT
DUBAI WATER CANAL
1700

SAFA A
DUBAI-UAE

Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
PLOT 02 / 3435336
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
Drawing Title:

BASEMENT 01 LEVEL - COLUMNS &


LEGEND:
WALLS SETTING OUT PLAN - PART
R.C. COLUMN
C
R.C. WALL Scale Drawn Checked Approved Size
AA MA NS
1 PLANTED COLUMN / WALL 1 : 150 A1
26.05.2016 24.08.2017 24.08.2017
NOTE:
BASEMENT 01 LEVEL- COLUMNS & WALLS SETTING OUT PLAN - PART C Drawing Number Rev.
1 1. FOR COLUMNS & WALLS SCHEDULES REFER TO EACH BUIDLING SHEETS
2. FOR CORE WALL DETAILS REFER TO EACH BUILDING SHEETS
14011603-02-00-SC0999c
SCALE 1 : 150
0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


N
11

N
10 KEY PLAN

1 1 1 1 General Notes:
SF1000b SF1000a SF1000c SF1000b
1. DO NOT SCALE FROM THIS DRAWING.
3.01 3.02 3.03 3.04 3.05 3.06 3.07 3.08 3.09 3.10 3.11 3.12 3.13 01 3.24 4.01 4.02 4.03 4.04 4.05 4.06 4.07 4.08 4.09 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17
PLOT LIMIT 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
9500 2200 9500 7750 8200 8200 8200 8200 5650 9500 2200 9500 10500 9400 10500 8200 1200 2300 9500 3400 8200 9900 8200 4100 3400 9500 9500
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
2200 BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


3.A
4.A PLOT LIMIT SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.
4.B
8200

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

3.B

4.C
8200

RAMP 1
3.C

7 LIFT 4.D
8200

3.D

4.E
8200

4.F
3.E

6 4.G
8200

4.H
LIFT LIFT

3.F
100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
8200

AUTHORITY APPROVAL 0 08.08.2017 NS


3.G LIFT LIFT
Purpose of Issue Rev. Date Appoved

4.J Client:
3.H
9500

PLOT LIMIT

5
3.I MEYDAN L.L.C
2150

P.O. Box 9305, Dubai , UAE.


3.J T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:
12300
9550

8200 3.23
8200
8200 3.22
8200 3.21
8200 3.20 abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
3.K 3.19
8200 www.ae-7.com
8200 3.18 Hassanicor Building, 6th Floor, Al Barsha 1
3.17
12300 3.16
PO Box 54115 Dubai, UAE
PLOT LIMIT P: +971 4 3997758 F: +971 4 3997759
4 3.15
3.14 Sub-Consultant:

Project Name:

3
DUBAI WATER CANAL
SAFA A
DUBAI-UAE

Project Description:
LEGEND: MIXED USE DEVELOPMENT
R.C COLUMN CONTINUE
R.C WALL CONTINUE (RETAIL & RESIDENTIAL)
R.C COLUMN / WALL STOPPING @ FLOOR LEVEL
R.C PLANTED COLUMN / WALL @ FLOOR LEVEL
PLOT 02 / 3435336
2 UPSTAND BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
SLAB OPENING 400 C.I.P
200 C.I.P 450 C.I.P
Drawing Title:
250 C.I.P 500 C.I.P
550 C.I.P
300 C.I.P
350 C.I.P
600 C.I.P
GROUND LEVEL - FRAMING PLAN -
OVERALL
P.C. PLANTED COLUMN P.T POST TENSION
P.W. PLANTED WALL D.P DROP PANEL
C.I.P. CAST IN PLACE
NOTE:
1. FOR BEAM SCHEDULE REFER TO DWG. 01-S6201 & 02-S6201
2. FOR SLAB REINFORCMENT SCHEDULE REFER TO DWG. 00-S6301 Scale Drawn Checked Approved Size
3. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 AA MA NS
1 4. FOR P.S. & D.P. REFER TO DWG. 00-S5301 1 : 350 A1
GROUND LEVEL - FRAMING PLAN - OVERALL 5. STRUCTURAL STEEL ELEMENTS (COLUMNS,BEAMS, CONNECTIONS, 26.05.2016 24.08.2017 24.08.2017
1 SCALE 1 : 350
ETC…) ARE TO BE DESIGNED AND VERIFIED BY THE STRUCTURAL
STEEL SUPPLIER AND SUBMITTED FOR THE ENGINEER APPROVAL. Drawing Number Rev.
6. FOR THE RINFORCEMENT AROUND SLAB OPENING REFER TO
DWG. 00-S5302
7. FOR EARTH PITS LOCATION REFER TO ELECTRICAL DRAWINGS 14011603-02-00-SF1000 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

3.01 3.02 3.03 3.04 3.05 3.06 3.07 3.08 3.09 3.10
1
SF1000b 3.11 3.12
DUBAI MUNICIPALITY STAMP:
N
PLOT LIMIT
11 9500 2200 9500 7750 8200 8200 8200 8200 5650 9500 2200
TRENCH

3-GRCB32
2600 3050 1140 4100X300X300

545
PLOT LIMIT

3-GRCB32
200
3-GRB23 830 50
8300 1200 Q

600
875 625 675 825

600 1700
1500 750 350 2150 1000 150 1350

775 725 975


650 850

1700
1300 200

1480

350
925

275

600
3-GRB26

475
3-GRB26

1050 450
3.A
PC1 P.C.

875
PC1

1900

1900
1025
3-GRB26
PC8 PC1 PC10

3-GRB23
3-GRB23
3050

3-GR23
PC10
PC10

3-GRB23
PC4 600 300 1260 MAHNHOLE 600 450 N
10 KEY PLAN
3-GRB25

850 650 600X600XDEPTH


8200

350mm. THICK C.I.P SLAB MAHNHOLE P.C.

1840

3-GRB15
600X600XDEPTH MAHNHOLE 350mm. THICK C.I.P SLAB

3-GRB12
-0.600 SSL

3-GRB22
5075
300mm. THICK C.I.P SLAB 600X600XDEPTH

3200
985 1020 P.C.
+0.400 SSL -0.600 SSL
1500 900 200 1600

2600
1350 150 A

1050
900

750
3-GRB25
775 725

175 175
3.B
PC1 600 300 D.P D.P D.P D.P
__
___
_1__
900

P.S.1 P.S.1 P.S.1 P.S.1 P.S.2

750
500 500 500 500 P.C.
PC1 PC2 S5306
TRENCH 320
3-GRB23
1750X300X300
9

6100
400mm. THICK C.I.P SLAB

3-GRB16
3-GRB11
8200

16 16 -0.550 SSL
400

13585 2655 P.C. P.C.


600 2600 ST3-01 S5303 S5303

3-GRB21
200
5275

1600 3510
General Notes:

200
1600
7
4225
3825

3165
PLANTER
S5303

2150
1. DO NOT SCALE FROM THIS DRAWING.
RAMP 1
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
3.C

125

290
PLANTER NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
600 300 PLANTER P.S.3 TRENCH
1325

D.P D.P D.P D.P D.P P.C. BY THE ENGINEER.

6862
P.S.1 P.S.1 P.S.1 P.S.1 1750X300X300
500 500 500 500 550

6854
PC28
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES

7529
4400 3300 500 6 SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK

7538
8 S5303 205 AT SITE.
17950

3-GRB22
6525
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
350mm. THICK C.I.P SLAB

3-GRB12
5 ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
8200

5 S5303 6825 350 450


AND RELEVANT SECTIONS OF THE SPECIFICATION.
S5303 -0.600 SSL

550
3-GRB15
3535
200 1600 1500 300

2575
900

3-GRB26
900 900

3.D
D.P D.P D.P D.P 3-GRB14 3-GRB14 P.S.4
P.S.1 P.S.1 P.S.1 P.S.1
900

PC2 500 500 500 500


PC2

3070
7
2820

5620
0
160
3-GRB24

300mm. THICK C.I.P SLAB

3-GRB6
7251
8200

7250
3-GRB29 INV.

300mm. THICK C.I.P SLAB


-0.200 SSL 1350
PLANTER
-0.200 SSL
PLANTER
7950

1600
16
200 1600 1500 300 5 16 7950
S5303
900

3-GRB26 S5303 3-GRB6


900 900

S5303
3.E 5
D.P P.S.4
D.P D.P
900

D.P

1550
500

400 1600 300 1750


6 PC2 P.S.1 500
S5303
500 300 3200 550 1200
PC2 P.S.1 500 P.S.1 P.S.1

3-GRB13
3-GRB7 2400
3-GRB30

1700

2500
350 3650 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
3-GRB24
8200

3-GRB28 AUTHORITY APPROVAL 0 08.08.2017 NS


1200

LIFT LIFT 1000 300 OPENING 850x650 BOTTOM


Purpose of Issue Rev. Date Appoved
3-GRB28

3-GRB19
LEVEL AT +4.825

1800 1950
OPENING 850x550
Client:
3-GRB27
BOTTOM LEVEL AT +4.995
2825

200 1600

2625
100

3-LB12 3-LB11
900

1200

4650

3-GRB26
3-LB10
900 900

3-LB5 3-LB5
3.F 3-GRB4
5
2000
ICK C.I.P SL
AB MEYDAN L.L.C
900

PC2 AB 400mm. TH
PC2 ICK C.I.P SL
400

1500 300 300mm. TH -0.200 S SL


P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
LIFT LIFT -0.200 SSL E: info@dubairacingclub.com W: www.dubairacingclub.com
AB
8200

ICK C.I.P SL
300mm. TH Principal Consultant:
3-GRB19

300 1275
3-GRB24

ST3-02 -0.200 SSL


3.G 200
3-LB5 3-LB5

700
300mm. THICK C.I.P SLAB
P.S.5 P.S.7 abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh

1650
-0.200 SSL www.ae-7.com
2300 200 P.S.6 Hassanicor Building, 6th Floor, Al Barsha 1
AB
ICK C.I.P SL PO Box 54115 Dubai, UAE
400mm. TH
775

4 3-GRB26 P.S.5 P: +971 4 3997758 F: +971 4 3997759


750 750

P.S.4
3.H Sub-Consultant:
P.S.4 -0.200 SSL
725

PC11
P.S.5
9500

300 2200 2150 PC11


P.S.5 AB
3-GRB23

ICK C.I.P SL
300mm. TH
3-GRB23 P.S.4
3050 -0.200 SSL
1500 1525 350
P.S.4
1500

AB
ICK C.I.P SL
300mm. TH
3-GRB2
1500

PC5 -0.200 SSL Project Name:


3.I
PC1 3-GRB2
2450
DUBAI WATER CANAL
2150

P.C.
3 3-GRB2 P.C.
P.C.
3.J
3-GRB2
SAFA A
3-GRB25

3-GRB2 ICK C.I.P SL


AB DUBAI-UAE
300mm. TH
P SLAB -0.400 SSL
-0.2IC00K SCS.I.L
300mm. TH 3-GRB2
Project Description:
825 675 3-GRB2
3-GRB33
ICK C.I.P SL
AB MIXED USE DEVELOPMENT
300mm. TH
9550

8200
3.22 (RETAIL & RESIDENTIAL)
3400

-0.400 SSL
1300

P.C. PLOT LIMIT 8200


3.21 PLOT 02 / 3435336
23

PC4
RB

2 8200 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)


3-G

95
UB 305x305x 3.20
600

LEGEND:
1150
800 700

8200
PC1 3.19 Drawing Title:
550

95 R.C COLUMN CONTINUE SLAB OPENING


UB 305x305x 400 C.I.P
8200
25 3.18
1225 12
GROUND LEVEL - FRAMING PLAN -
R.C WALL CONTINUE 200 C.I.P 450 C.I.P
3.K
1500 1200 8200
3.17 R.C COLUMN / WALL STOPPING @ FLOOR LEVEL
1 250 C.I.P 500 C.I.P
S5303 8200
3.16 R.C PLANTED COLUMN / WALL @ FLOOR LEVEL 300 C.I.P 550 C.I.P PART A
UPSTAND 350 C.I.P 600 C.I.P
12300 3.15

NOTE: P.C. PLANTED COLUMN P.T POST TENSION Scale Drawn Checked Approved Size
PLOT LIMIT 1. FOR BEAM SCHEDULE REFER TO DWG. 03-S6201 & 04-S6201 P.W. PLANTED WALL D.P DROP PANEL
3.14 AA MA NS
2. FOR SLAB DETAILS REFER TO DWG. 00-S5301 TO DWG. 00-S5306 C.I.P. CAST IN PLACE
1 3. FOR SLAB REINFORCEMENT SCHEDULE REFER TO DWG. 00-S6301
1 : 150 A1
4. FOR STAIRS DETAILS REFER TO DWG. 00-S5501
26.05.2016 24.08.2017 24.08.2017
GROUND LEVEL - FRAMING PLAN - PART A 5. FOR P.S. & D.P. REFER TO DWG. 00-S5301

1 6. STRUCTURAL STEEL ELEMENTS (COLUMNS,BEAMS, CONNECTIONS, ETC…) ARE TO BE DESIGNED AND VERIFIED BY
Drawing Number Rev.
SCALE 1 : 150
THE STRUCTURAL STEEL SUPPLIER AND SUBMITTED FOR THE ENGINEER APPROVAL.
7. FOR THE RINFORCEMENT AROUND SLAB OPENING REFER TO DWG. 00-
8. FOR EARTH PITS LOCATION REFER TO ELECTRICAL DRAWINGS
S5302
14011603-02-00-SF1000a 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


N
11

1
Q
1
SF1000a SF1000c

3.10 3.11 3.12 3.13 01 3.24 4.01 4.02 4.03 4.04 4.05 4.06 4.07

9500 2200 9500 10500 9400 10500 8200 1200 2300 4700 4800 3400

TRENCH
4000X300X300
875 625 675 825 N
150 1350
2150 350 TRENCH KEY PLAN
10 PLOT LIMIT 350 2150 750 750 650 850 3300X150X150 1500

600
275

175
600

725 775
3-GRB26
1050 450
3.A
P.C.

1500
4.A 4-GRB17
PC1

1900
3-GRB26

350
4235

2225
PC10 PC10

565 1500
1900
PC10 4-GRB17

3-GRB23

2225
3-GRB23
55

3-GRB23
PC1

1060
1000
3-GR23
PC10 4.B

1175

1175
600 450
PC4 PC4

4-GRB15
B

4-GRB17
P.C.

3-GRB31
3-GRB22
3200
300mm. THICK C.I.P SLAB 300mm. THICK C.I.P SLAB 300mm. THICK C.I.P SLAB
P.C.
9 200
-0.050 SSL -0.200 SSL -0.200 SSL
300 1500

1050

1800
1800
3.B
__
___
_1__

1500
1800
P.S.2 P.C.
PC1 4-GRB15 PC2 4-GRB18 PC2
General Notes:

3-GRB31
S5306
300mm. THICK C.I.P SLAB 350 2150 PC8 50 1600 200

975
820

820

820
4-GRB18
1. DO NOT SCALE FROM THIS DRAWING.
4.C TRENCH
-0.400 SSL
400mm. THICK C.I.P SLAB 1750X300X300 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS

85
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
3-LB10 BY THE ENGINEER.
-0.550 SSL 760

4-GRB17
P.C. P.C.
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES

3-LB13
3-GRB21

SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK


8 AT SITE.

6400
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ST3-03 300 1500 1600 200 ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
200 ST4-01 AND RELEVANT SECTIONS OF THE SPECIFICATION.
200

1800
3.C 200
290

1800
P.S.3 D.P P.C. TRENCH
1750X300X300 PC26 PC2 4-GRB16 PC2

3-LB15
550

825

825
625
205 LIFT 4.D
3350 9400 550
3-GRB22

850 3-GRB8

350 450

4-GRB16
7
3-GRB20
300mm. THICK C.I.P SLAB
550

5150
EXPANSION JOINT 50mm -0.200 SSL
2575

3.D 150 500 175


3-GRB14 P.S.4 3-GRB8
5

400 1345

1450
4-GRB28 S5507
4.E

4-GRB7
5200

3700
350mm. THICK C.I.P SLAB

1755
4-GRB27

4-GRB4
-0.200 SSL 300mm. THICK C.I.P SLAB -0.400 SSL
300mm. THICK C.I.P SLAB
3-GRB18

4-GRB12
3-GRB6

6 -0.200 SSL 3100


12

300mm. THICK C.I.P SLAB

4-GRB12
-0.600 SSL 4-GRB29
4-GRB

4-GRB4
-0.200 SSL -0.400 SSL 1850 300

995
4-GRB28 13 4.F

300 250
100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
77

S5303
12
.9

5800 1800 AUTHORITY APPROVAL 0 08.08.2017 NS


40

3-GRB6
300mm. THICK C.I.P SLAB
°

4-GRB26 S5303
350mm. THICK C.I.P SLAB Purpose of Issue Date Appoved

4-GRB30
3.E Rev.

4-GRB6
P.S.4
1550
400 1600 300 1750

300 3200 550 1200 ESCALATOR ESCALATOR -0.600 SSL -0.200 SSL Client:
3465 250mm. THICK C.I.P SLAB

4935
3-GRB13

4-GRB24

4-GRB20
-1.500 SSL
4100

4-GRB4

4-GRB21
4-GRB24

2400 1700 PLANTER 200 5150 300 2775


2500

5 3.G -0.200 SSL


3-GRB17

4.G
4-GRB26 MEYDAN L.L.C
4-GRB11

1165
P.O. Box 9305, Dubai , UAE.
LIFT LIFT 1000 300 OPENING 850x650 BOTTOM 4-GRB4 D.P D.P T: +9714 3270000 F: +9714 3270007
4-GRB23 250mm. THICK C.I.P SLAB
15 500 500
3-GRB19

LEVEL AT +4.825 E: info@dubairacingclub.com W: www.dubairacingclub.com

4-GRB24
400 1800 ? 9 -1.500 SSL
1800 1950

4.H

4-GRB24
1800 400 S5303
3800

Principal Consultant:

2515
S5303 PLANTER
9
2625

S5303
350mm. THICK C.I.P SLAB 4-GRB22
3-LB5 3-LB5 300mm. THICK C.I.P SLAB
3.F 4-GRB26

4-GRB5
3-GRB5 -0.400 SSL
1975 200 -0.200 SSL abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
4-GRB13
3-GRB10

www.ae-7.com
350mm. THICK C.I.P SLAB 300mm. THICK C.I.P SLAB Hassanicor Building, 6th Floor, Al Barsha 1
4-GRB13
4-GRB27 PO Box 54115 Dubai, UAE
-0.400 SSL -0.600 SSL P: +971 4 3997758 F: +971 4 3997759

4-GRB29
4
Sub-Consultant:
300mm. THICK C.I.P SLAB 1400 200

4-GRB1 4-GRB2 4-GRB2


-0.600 SSL 13
4-GRB10

4-GRB28

3.I
5100

4-GRB19 4-GRB31
9715

S5303
P.S.7
1350

1350
4200 300mm. THICK C.I.P SLAB 300 350mm. THICK C.I.P SLAB
500 2580 4100 300 2960
3-GRB9

3.J ICK C.I.P SLAB


400mm. TH 4.J
445

4-GRB24

-1.500 SSL 250mm. THICK C.I.P SLAB -0.400 SSL

4-GRB25
9

4-GRB24
3.H
-0.200 SSL
4-GRB9

-1.500 SSL

2750
4-GRB27 Project Name:
55

5550 S5303 9
4-GRB23
1860

4-GRB9

PLANTER
4-GRB23

12 S5303
ICK C.I.P SL
AB 4-GRB23 DUBAI WATER CANAL
300

3 300mm. TH S5303
PLANTER 350mm. THICK C.I.P SLAB 4-GRB23

300
350mm. THICK C.I.P SLAB
SAFA A
4-GRB24

250mm. THICK C.I.P SLAB -0.400 SSL


3-GRB3
3100

300 5625 300 1135 DUBAI-UAE


-0.400 SSL -1.500 SSL
4-GRB24
4-GRB9

3-GRB2 4-GRB23 PLANTER


Project Description:
AB
ICK C.I.P SL 3100 1540
300mm. TH P.C. MIXED USE DEVELOPMENT
PLOT LIMIT
P.C.
-0.400 SSL (RETAIL & RESIDENTIAL)
3.K PLOT 02 / 3435336
2 EXPANSION JOINT 50mm LEGEND: BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
R.C COLUMN CONTINUE SLAB OPENING 400 C.I.P
Drawing Title:
12300 R.C WALL CONTINUE 200 C.I.P 450 C.I.P

8200
3.23
R.C COLUMN / WALL STOPPING @ FLOOR LEVEL 250 C.I.P 500 C.I.P GROUND LEVEL - FRAMING PLAN -
R.C PLANTED COLUMN / WALL @ FLOOR LEVEL

UPSTAND
300 C.I.P

350 C.I.P
550 C.I.P

600 C.I.P
PART B
3.22

3.21 NOTE: P.C. PLANTED COLUMN P.T POST TENSION


1. FOR BEAM SCHEDULE REFER TO DWG. 03-S6201 & 04-S6201 P.W. PLANTED WALL D.P DROP PANEL Scale Drawn Checked Approved Size
2. FOR SLAB DETAILS REFER TO DWG. 00-S5301 TO DWG. 00-S5306 C.I.P. CAST IN PLACE
3. FOR SLAB REINFORCEMENT SCHEDULE REFER TO DWG. 00-S6301
AA MA NS
1 4. FOR STAIRS DETAILS REFER TO DWG. 00-S5501
1 : 150 A1
5. FOR P.S. & D.P. REFER TO DWG. 00-S5301
26.05.2016 24.08.2017 24.08.2017

GROUND LEVEL - FRAMING PLAN - PART B


6. STRUCTURAL STEEL ELEMENTS (COLUMNS,BEAMS, CONNECTIONS, ETC…) ARE TO BE DESIGNED AND VERIFIED BY
THE STRUCTURAL STEEL SUPPLIER AND SUBMITTED FOR THE ENGINEER APPROVAL. Drawing Number Rev.
1 7. FOR THE RINFORCEMENT AROUND SLAB OPENING REFER TO DWG. 00-
14011603-02-00-SF1000b
SCALE 1 : 150 8. FOR EARTH PITS LOCATION REFER TO ELECTRICAL DRAWINGS
S5302
0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


N
11
1
SF1000b Q

4.05 4.06 4.07 4.08 4.09 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17

4800 3400 8200 9900 8200 4100 3400 700 8200 600 2200 9500

TRENCH
3300X150X150 1500 N
10 KEY PLAN
PLOT LIMIT
4.A 4-GRB17
TRENCH
250 650 650 850 3300X150X150 PLOT LIMIT

565 1500
1750

55 PC1 325 1175 1000 700 1700 PC1

1060

425
1000 500

215
4-GRB18

425
4-GRB18

925 575
4.B

325
P.C. 4-GRB17
PC1 PC4 4965 PC4

2975

2975
4-GRB17
300mm. THICK C.I.P SLAB

4-GRB18

4-GRB18
350mm. THICK C.I.P SLAB PC5 C
300mm. THICK C.I.P SLAB PC5

4-GRB17

4-GRB17
-0.800 SSL
8200

-0.050 SSL
9 -0.200 SSL

4-GRB15
__
___
_2__
1800 S5306
P.C.
325 1175 1000 1700 P.C.
4-GRB18 PC2
General Notes:
1600 200
820

740 760
4.C P.C.

765
1. DO NOT SCALE FROM THIS DRAWING.
PC1 350mm. THICK C.I.P SLAB
PC5 TRENCH 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS

2840

4-GRB17
-0.200 SSL NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
1750X300X300
4-GRB17

BY THE ENGINEER.
205
OPENING 450x600 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES

1500
350mm. THICK C.I.P SLAB BOTTOM LEVEL AT +0.600 SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK

4-GRB17
8
8200

AT SITE.
1600 200 125 1375 PC1 -0.800 SSL 1325 450
CENTERED OPENING 1200x1500 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
BOTTOM LEVEL AT +2.245 ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
1800

AND RELEVANT SECTIONS OF THE SPECIFICATION.


900
4-GRB16 PC2 ST4-03

4-LB9
200

900
825

4.D RAMP 2
4-GRB16

900
PC2 90 800
4-GRB16

4-GRB16
7 300mm. THICK C.I.P SLAB OPENING 800X600
AT LEVEL -1.350 SSL
8200

-0.200 SSL
350mm. THICK C.I.P SLAB
-0.200 SSL

500 175 250


TRENCH
1750X150X150
3000
1450

4100

100
4.E

100

550
TRENCH

1475
ST4-02
1755

LIFT 1250 450


4-GRB4

200 1750X150X150
4100

4-LB11 4-LB11

1850
6 350mm. THICK C.I.P SLAB 8
-0.200 SSL 375 950 S5303 240
200 200 1650 4-GRB4
200

1300
4.F

200

500
1200 405

425
600
200
650 600 2195

1300
PLANTER 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
350mm. THICK C.I.P SLAB

500
AUTHORITY APPROVAL 0 08.08.2017 NS

200

600

3000
4625 300

200
-0.200 SSL 8 Purpose of Issue Rev. Date Appoved

1400
5600

4-GRB8
S5303 300mm. THICK C.I.P SLAB Client:

200
4-GRB4 2400 1750 -0.200 SSL P.C. P.C.
725 1375

2200
1995
200 200
4.G
5
D.P D.P D.P MEYDAN L.L.C
2200

D.P D.P D.P 500 500 500 P.O. Box 9305, Dubai , UAE.
500 500 500 4-GRB14
T: +9714 3270000 F: +9714 3270007
4.H E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:

4-GRB4
300mm. THICK C.I.P SLAB
350mm. THICK C.I.P SLAB
-0.200 SSL abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
-0.075 SSL 350mm. THICK C.I.P SLAB
www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
9500

-0.400 SSL PO Box 54115 Dubai, UAE


P: +971 4 3997758 F: +971 4 3997759
4
4-GRB3 Sub-Consultant:
4-GRB2 4-GRB2 4-GRB2 4-GRB2 4-GRB2 4-GRB2

200
P.C.

1800
350mm. THICK C.I.P SLAB
4.J P.W.
-0.400 SSL

Project Name:

3
PLOT LIMIT DUBAI WATER CANAL
PLOT LIMIT
SAFA A
DUBAI-UAE

Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
PLOT 02 / 3435336
2 LEGEND: BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
R.C COLUMN CONTINUE SLAB OPENING 400 C.I.P
Drawing Title:
R.C WALL CONTINUE 200 C.I.P 450 C.I.P

R.C COLUMN / WALL STOPPING @ FLOOR LEVEL 250 C.I.P 500 C.I.P
GROUND LEVEL - FRAMING PLAN -
R.C PLANTED COLUMN / WALL @ FLOOR LEVEL 300 C.I.P 550 C.I.P

UPSTAND 350 C.I.P 600 C.I.P


PART C
NOTE: P.C. PLANTED COLUMN P.T POST TENSION
1. FOR BEAM SCHEDULE REFER TO DWG. 03-S6201 & 04-S6201 P.W. PLANTED WALL D.P DROP PANEL
2. FOR SLAB DETAILS REFER TO DWG. 00-S5301 TO DWG. 00-S5306 C.I.P. CAST IN PLACE Scale Drawn Checked Approved Size
3. FOR SLAB REINFORCEMENT SCHEDULE REFER TO DWG. 00-S6301 AA MA NS
1 4. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 1 : 150 A1
5. FOR P.S. & D.P. REFER TO DWG. 00-S5301 26.05.2016 24.08.2017 24.08.2017
6. STRUCTURAL STEEL ELEMENTS (COLUMNS,BEAMS, CONNECTIONS, ETC…) ARE TO BE DESIGNED AND VERIFIED BY
GROUND LEVEL - FRAMING PLAN - PART C THE STRUCTURAL STEEL SUPPLIER AND SUBMITTED FOR THE ENGINEER APPROVAL. Drawing Number Rev.
1 7. FOR THE RINFORCEMENT AROUND SLAB OPENING REFER TO DWG. 00-
14011603-02-00-SF1000c
SCALE 1 : 150
8. FOR EARTH PITS LOCATION REFER TO ELECTRICAL DRAWINGS
S5302
0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


N
11

N
10 KEY PLAN

1 1 1 1
SRB0999b SRB0999a SRB0999c SRB0999b
General Notes:
3.01 3.02 3.03 3.04 3.05 3.06 3.07 3.08 3.09 3.10 3.11 3.12 3.13 01 3.24 4.01 4.02 4.03 4.04 4.05 4.06 4.07 4.08 4.09 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17
PLOT LIMIT 1. DO NOT SCALE FROM THIS DRAWING.
9500 2200 9500 7750 8200 8200 8200 8200 5650 9500 2200 9500 10500 9400 10500 8200 12002300 9500 3400 8200 9900 8200 4100 3400 700 8200 600 9500
2200 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
3.A BY THE ENGINEER.
4.A PLOT LIMIT
4.B 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8
8200

AT SITE.

8200
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
3.B AND RELEVANT SECTIONS OF THE SPECIFICATION.

4.C
8200

8200
3.C

4.D
8200

8200
3.D

4.E
8200

4100
4.F
3.E

5600
4.G
8200

2200
6 4.H

3.F

9500
8200

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


3.G
AUTHORITY APPROVAL 0 08.08.2017 NS
4.J Purpose of Issue Rev. Date Appoved
3.H
9500

Client:
PLOT LIMIT

3.I
2150

5
3.J MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com
12300
9550

8200 3.23 Principal Consultant:


8200
8200 3.22
8200 3.21
8200 3.20
3.K 3.19
8200
8200 3.18
3.17 abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
12300 3.16 www.ae-7.com
PLOT LIMIT Hassanicor Building, 6th Floor, Al Barsha 1
3.15
PO Box 54115 Dubai, UAE
3.14 P: +971 4 3997758 F: +971 4 3997759
4
Sub-Consultant:

Project Name:

3
DUBAI WATER CANAL
SAFA A
DUBAI-UAE

Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
PLOT 02 / 3435336
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
LEGEND:
Drawing Title:
R.C COLUMN CONTINUE
R.C WALL CONTINUE BASEMENT 01 LEVEL - BOTTOM
R.C COLUMN / WALL STOPPING @ FLOOR LEVEL
R.C PLANTED COLUMN / WALL @ FLOOR LEVEL REINFRORCEMENT PLAN -
UPSTAND
SLAB OPENING OVERALL
P.C. PLANTED COLUMN
P.W. PLANTED WALL Scale Drawn Checked Approved Size
C.I.P. CAST IN PLACE AA MA NS
1 P.T POST TENSION 1 : 350 A1
D.P DROP PANEL 08.06.2017 24.08.2017 24.08.2017

BASEMENT 01 LEVEL- BOTTOM REINFORCEMENT PLAN - OVERALL


NOTE:
Drawing Number Rev.
1
1. FOR BEAM SCHEDULE REFER TO DWG. 03-S6201 TO 03-S6202 & 04-S6201

SCALE 1 : 350
2. FOR SLAB REINFORCEMENT SCHEDULE REFER TO DWG. 00-S6301
3. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 TO 00-S5507 14011603-02-00-SRB0999 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

1
SRB0999b DUBAI MUNICIPALITY STAMP:
3.01 3.02 3.03 3.04 3.05 3.06 3.07 3.08 3.09 3.10 3.11 3.12

PLOT LIMIT
N
11 9500 2200 9500 7750 8200 8200 8200 8200 5650 9500 2200

PLOT LIMIT
Q

3.A

N
10 KEY PLAN
8200

7500
AB2 AB2 AB2 AB2 AB2
AB28 AB3 AB2

8000

8000

8000
A

AB2

AB2

AB2

AB2

AB2
5500

5500

5500

AB31
AB1

AB6
5500
3.B

5500 5500 5500 5500 5500


5500 5500
6500

9 AB4 AB4 AB4 AB4

AB11
18500

AB4
8200

MESH T20@150 T&B (BW)


AB13

9000
5250 5500 General Notes:
AB2 AB2 AB2 AB2 AB2 AB2 AB22

24000

24000

24000

24000
1. DO NOT SCALE FROM THIS DRAWING.

AB2

AB2

AB2

AB2

AB2

AB2

AB2

AB5
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS

5500

5500

5500

5500

5500

5500
3.C NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

5500 5500 5500 5500 5500 5500 5500 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
7000 SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.
AB2
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
AB40

14000
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
8200

AND RELEVANT SECTIONS OF THE SPECIFICATION.

13750
AB2 AB3 AB3 AB2 AB2
AB3 AB12
AB21

AB2

AB3

AB3

AB2

AB2
5500

5500

5500

5500

5500
AB2

AB3

AB5
5500

5500
3.D

7000 5500 5500 5500 5500 5500


7 5500

AB27
MESH T20@150 T&B (BW) 500mm FOUNDATION SLAB
8200

AB2 AB3
AB2 AB22 AB2
AB14

AB2
5500

AB4

5500
AB2

AB10
11000

5500
3.E
AB15

AB18
6

AB17

6500
AB23 AB16 5500

10000
10000
AB17
4500 11500

10000
10000
100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
AB26
8200

AB2 AUTHORITY APPROVAL 0 08.08.2017 NS


11750 AB45
Purpose of Issue Rev. Date Appoved
5500 Client:
5500

5500
5500
AB2

5500

3.F AB3
5 5500
MEYDAN L.L.C

22000
AB2

AB8
8000

P.O. Box 9305, Dubai , UAE.


AB1 8500 T: +9714 3270000 F: +9714 3270007
AB4 E: info@dubairacingclub.com W: www.dubairacingclub.com
AB2
8200

AB18
AB2 Principal Consultant:

10000
AB17
AB22

10000
AB19
3.G

5500
AB2

10000

AB2
10000
AB4
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
AB17

10000
AB22 5500 www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
4000

PO Box 54115 Dubai, UAE


AB17
AB24

AB13

P: +971 4 3997758 F: +971 4 3997759


4
10000

3.H 6500 5500 5500 Sub-Consultant:


AB6
9500

5500
AB5 5500
AB3
8000

5500 AB5
4000
5500
AB3

5500 AB5
5500

6000
MESH T20@150 T&B (BW)

AB21
AB5
AB23 5500 Project Name:

6000
3.I

AB21
AB5
5500
DUBAI WATER CANAL
2150

6000
AB21
MESH T20@150 T&B (BW) AB5
3 5500
SAFA A
AB20

3.J AB5

7000
5500
AB5
AB20

DUBAI-UAE
7000

5500
AB5
AB20

7000

5500
Project Description:
AB20

7000

5500 8200
MIXED USE DEVELOPMENT
AB20

3.22
7000

8200
9550

(RETAIL & RESIDENTIAL)


8000
AB6

5500 8200
PLOT LIMIT
LEGEND: PLOT 02 / 3435336
4000 8200
5500
2 AB23 R.C COLUMN CONTINUE BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
8200 3.21
R.C WALL CONTINUE Drawing Title:
8200 3.20
R.C COLUMN / WALL STOPPING @ FLOOR LEVEL
3.K 8200 3.19 R.C PLANTED COLUMN / WALL @ FLOOR LEVEL BASEMENT 01 LEVEL - BOTTOM
12300
3.18 UPSTAND
REINFRORCEMENT PLAN - PART A
3.17 SLAB OPENING

3.16 P.C. PLANTED COLUMN


PLOT LIMIT P.W. PLANTED WALL Scale Drawn Checked Approved Size
3.15 C.I.P. CAST IN PLACE AA MA NS
1 3.14 P.T POST TENSION 1 : 150 A1
D.P DROP PANEL 08.06.2017 24.08.2017 24.08.2017

BASEMENT 01 LEVEL- BOTTOM REINFORCEMENT PLAN - PART A NOTE: Drawing Number Rev.
1 1. FOR BEAM SCHEDULE REFER TO DWG. 03-S6201 TO 03-S6202 & 04-S6201

14011603-02-00-SRB0999a 0
2. FOR SLAB REINFORCEMENT SCHEDULE REFER TO DWG. 00-S6301
SCALE 1 : 150
3. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 TO 00-S5507

All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

1 1
DUBAI MUNICIPALITY STAMP:
SRB0999a SRB0999c
N
11

Q
3.10 3.11 3.12 3.13 01 3.24 4.01 4.02 4.03 4.04 4.05 4.06 4.07

9500 2200 9500 10500 9400 10500 8200 1200 2300 4700 4800 3400

PLOT LIMIT
N
10 3.A
KEY PLAN
4.A

4.B
8200

3500
B

7500

AB45

8200
AB2 AB3

9
AB31

AB3

5500
3.B
MESH T20@150 T&B (BW)

5500 5500
General Notes:

AB8
4.C
11250 1. DO NOT SCALE FROM THIS DRAWING.
AB4
8200

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.
9000

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES

8200
AB22 SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8
24000

AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


AB5

3.C ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS

AB9
10500
AB8

AND RELEVANT SECTIONS OF THE SPECIFICATION.


AB8
5500 4000
2000
LIFT 4.D

AB40
8200

7500

8200
AB12 AB10
3500
AB10
AB5

5500

3.D

AB11

1750
9000

2000
10000 AB39
4.E AB38
3500

AB6

AB40

AB40
AB27

AB27

AB1

AB1
8200

4100

AB27
AB22

4000
5500
AB23
6 4000 8500 8000
10000

4500 4500
18000

AB2 AB6 4.F 8000


AB3 AB3
AB3 AB3
AB28
100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
AB10

AB5

5500
5500

AB27
3.E
AB45 AUTHORITY APPROVAL 0 08.08.2017 NS
5600

AB27
Purpose of Issue Rev. Date Appoved

4000
8000

4000
Client:
4000

AB33
AB3 AB2

AB33
AB33

9500

AB33

9500
9500

9500
AB24
3.G
4.G
3000
8200

AB2
AB3

5500
5500
2200

MESH T20@150 T&B (BW)


MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
4.H T: +9714 3270000 F: +9714 3270007
AB3 5500 E: info@dubairacingclub.com W: www.dubairacingclub.com
5500 5500 5500 5500
AB29 5500
Principal Consultant:
AB22

5500

3.F

500mm FOUNDATION SLAB


AB8

8500 5500
AB30

MESH T20@150 T&B (BW) abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
8500

AB5 www.ae-7.com
9500

AB3 AB2 AB3


Hassanicor Building, 6th Floor, Al Barsha 1
AB2
AB3 AB3 PO Box 54115 Dubai, UAE
8200

P: +971 4 3997758 F: +971 4 3997759


4

AB5
Sub-Consultant:

AB34
5500

5500

AB3

AB2
5500

5500
AB2

3.I 8000
AB3

AB3
5500

5500

7500
5500
5500 5500 5500 5500
3.J
4.J
5500 5500
3.H AB31
AB1
Project Name:

2500
AB5
AB32

AB5
DUBAI WATER CANAL
6000

3
SAFA A
6000
AB21
6000
AB21

8000
DUBAI-UAE
5500
5500
Project Description:
PLOT LIMIT
MIXED USE DEVELOPMENT
3.K
(RETAIL & RESIDENTIAL)
12300
LEGEND: PLOT 02 / 3435336
2 R.C COLUMN CONTINUE BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
8200
R.C WALL CONTINUE Drawing Title:
3.23 R.C COLUMN / WALL STOPPING @ FLOOR LEVEL

R.C PLANTED COLUMN / WALL @ FLOOR LEVEL BASEMENT 01 LEVEL - BOTTOM


3.21
3.22
UPSTAND
REINFRORCEMENT PLAN - PART B
SLAB OPENING

P.C. PLANTED COLUMN


P.W. PLANTED WALL Scale Drawn Checked Approved Size
C.I.P. CAST IN PLACE AA MA NS
1 P.T POST TENSION 1 : 150 A1
D.P DROP PANEL 08.06.2017 24.08.2017 24.08.2017
BASEMENT 01 LEVEL- BOTTOM REINFORCEMENT PLAN - PART B NOTE:
1 1. FOR BEAM SCHEDULE REFER TO DWG. 03-S6201 TO 03-S6202 & 04-S6201
Drawing Number Rev.
SCALE 1 : 150 2. FOR SLAB REINFORCEMENT SCHEDULE REFER TO DWG. 00-S6301
3. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 TO 00-S5507
14011603-02-00-SRB0999b 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

1
DUBAI MUNICIPALITY STAMP:
SRB0999b
N
11

4.05 4.06 4.07 4.08 4.09 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 Q

4800 3400 8200 9900 8200 4100 3400 700 8200 600 2200 9500

PLOT LIMIT N
10 4.A
PLOT LIMIT
KEY PLAN
4.B
8200

4.C
General Notes:

AB45

6500
AB7
2500 4500

5000
AB2 1. DO NOT SCALE FROM THIS DRAWING.

AB8
AB20
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
AB13 13250 NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 3000 AT SITE.

AB46
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT

AB2

10500
16000
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.
16400

4.D

2500 13250

AB46
AB42
MESH T20@150 T&B (BW)
7

AB7
AB5 AB5
AB13
13000

5500

5500

5500
AB5
AB20
AB39
4.E
AB7 AB7 2500

5000
AB40

AB40

AB43

AB37

AB42
5000

5000
5000

5500
6000
6500
4100

AB4 AB3 AB42


AB32 AB25
AB7

6500 7000 8750 3500


9500

8000
6 13000

AB3
5500
4.F

4000
AB3 AB3 AB3
AB27 AB27 AB22
AB3
AB22 AB42 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS

AB27
5600

AB27

500mm FOUNDATION SLAB

4000
AUTHORITY APPROVAL 0 08.08.2017 NS
4000

11500

9000
AB44
11000
Purpose of Issue Rev. Date Appoved
4000 4000 AB3
AB33

AB2 AB3
AB33

AB33
9500

9500
AB21 Client:
9500

9500

4.G

AB1
AB13
AB3

AB33
AB3
AB2

5500

5500
5500
2200

5000
5 MESH T20@150 T&B (BW) 9000 2500
4.H MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
5500 5500 5500 5500 5500 5500 5500 T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:
13000

AB5 AB5 AB22 AB5


9500

AB2 AB3 AB3 AB3


abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com

11000
Hassanicor Building, 6th Floor, Al Barsha 1

AB35
9000

9250

AB1
AB37
PO Box 54115 Dubai, UAE
9000

9000
AB35

AB20
AB34

AB36

AB36

P: +971 4 3997758 F: +971 4 3997759


AB2

4
5500

AB23 AB23 AB23 AB23 AB6

7000
6500

6500
Sub-Consultant:
7000
7500
7500

5500 5500 5500 7000 2500


5500 5500 5500 5500
4.J

PLOT LIMIT Project Name:

3
PLOT LIMIT DUBAI WATER CANAL
SAFA A
DUBAI-UAE

Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
LEGEND: PLOT 02 / 3435336
2 R.C COLUMN CONTINUE BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
R.C WALL CONTINUE Drawing Title:
R.C COLUMN / WALL STOPPING @ FLOOR LEVEL

R.C PLANTED COLUMN / WALL @ FLOOR LEVEL BASEMENT 01 LEVEL - BOTTOM


UPSTAND
REINFRORCEMENT PLAN - PART C
SLAB OPENING

P.C. PLANTED COLUMN


P.W. PLANTED WALL Scale Drawn Checked Approved Size
C.I.P. CAST IN PLACE AA MA NS
1 P.T POST TENSION 1 : 150 A1
D.P DROP PANEL 08.06.2017 24.08.2017 24.08.2017
NOTE:
BASEMENT 01 LEVEL- BOTTOM REINFORCEMENT PLAN - PART C 1. FOR BEAM SCHEDULE REFER TO DWG. 03-S6201 TO 03-S6202 & 04-S6201
Drawing Number Rev.
1 SCALE 1 : 150
2. FOR SLAB REINFORCEMENT SCHEDULE REFER TO DWG. 00-S6301
3. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 TO 00-S5507
14011603-02-00-SRB0999c 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


N
11

N
10 KEY PLAN

1 1 1 1 General Notes:
SRT0999b SRT0999a SRT0999c SRT0999b
1. DO NOT SCALE FROM THIS DRAWING.
3.01 3.02 3.03 3.04 3.05 3.06 3.07 3.08 3.09 3.10 3.11 3.12 3.13 01 3.24 4.01 4.02 4.03 4.04 4.05 4.06 4.07 4.08 4.09 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
PLOT LIMIT
9500 2200 9500 7750 8200 8200 8200 8200 5650 9500 2200 9500 10500 9400 10500 8200 12002300 9500 3400 8200 9900 8200 4100 3400 700 8200 600 9500 NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.
2200
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
3.A SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 4.A PLOT LIMIT AT SITE.
4.B
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
8200

ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS


AND RELEVANT SECTIONS OF THE SPECIFICATION.

8200
3.B

4.C
8200

8200
3.C
7 LIFT 4.D
8200

8200
3.D

4.E
8200

4100
4.F
3.E

5600
6
4.G
8200

2200
LIFT LIFT 4.H

3.F
100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
0 NS

9500
AUTHORITY APPROVAL 08.08.2017
8200

LIFT LIFT
3.G
Purpose of Issue Rev. Date Appoved
Client:
4.J
3.H
9500

PLOT LIMIT
5
3.I
MEYDAN L.L.C
2150

P.O. Box 9305, Dubai , UAE.


T: +9714 3270000 F: +9714 3270007
3.J E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:
12300
9550

8200 3.23
8200
8200 3.22
8200 3.21
3.20 abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
3.K 8200 www.ae-7.com
8200 3.19
8200 3.18 Hassanicor Building, 6th Floor, Al Barsha 1
3.17 PO Box 54115 Dubai, UAE
12300 3.16 P: +971 4 3997758 F: +971 4 3997759
4 PLOT LIMIT
3.15
Sub-Consultant:
3.14

Project Name:

3
DUBAI WATER CANAL
SAFA A
DUBAI-UAE

Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
PLOT 02 / 3435336
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
LEGEND:
Drawing Title:
R.C COLUMN CONTINUE
R.C WALL CONTINUE BASEMENT 01 LEVEL - TOP
R.C COLUMN / WALL STOPPING @ FLOOR LEVEL
R.C PLANTED COLUMN / WALL @ FLOOR LEVEL REINFRORCEMENT PLAN -
UPSTAND
SLAB OPENING OVERALL
P.C. PLANTED COLUMN
P.W. PLANTED WALL Scale Drawn Checked Approved Size
C.I.P. CAST IN PLACE AA MA NS
1 P.T POST TENSION 1 : 350 A1
D.P DROP PANEL 08.06.2017 24.08.2017 24.08.2017

BASEMENT 01 LEVEL- TOP REINFORCEMENT PLAN - OVERALL NOTE:


Drawing Number Rev.
1
1. FOR BEAM SCHEDULE REFER TO DWG. 03-S6201 TO 03-S6202 & 04-S6201

SCALE 1 : 350
2. FOR SLAB REINFORCEMENT SCHEDULE REFER TO DWG. 00-S6301
3. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 TO 00-S5507 14011603-02-00-SRT0999 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


3.01 3.02 3.03 3.04 3.05 3.06 3.07 3.08 3.09 3.10 1 3.11 3.12

PLOT LIMIT SRT0999b N


9500 2200 9500 7750 8200 8200 8200 8200 5650 9500 2200
11
PLOT LIMIT
Q

3.A

N
10 KEY PLAN
8200

AT15
AT2
6500
AT3 AT3 AT3 AT3 AT3 AT8

AT1

7500

7500

7500

7500

7500

7500
AT26

AT26

AT26

AT26

AT26

AT21
A

AT16
AT4

10500
10500
3.B

5500 5500 5500 5500 5500


5500
6500 4500

AT4
AT3 AT3 AT3 AT46 AT3
8200

11000 MESH T20@150 T&B (BW)

21500
AT3 AT3 AT3 AT3 AT3 AT2
General Notes:

24000

24000

24000

24000
5000
1. DO NOT SCALE FROM THIS DRAWING.

AT5

AT3

AT3

AT3

AT3

AT3

AT2
5500

5500

5500

5500

5500

5500
3.C 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
AT45 BY THE ENGINEER.

AT41
4500 5500 5500 5500 5500 5500 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT32 AT SITE.

3000
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
AT22

14000
8200

ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS


AND RELEVANT SECTIONS OF THE SPECIFICATION.
AT12

3500 7500 AT3 AT3 AT3 AT3 AT3 AT2

AT45

AT3

AT3

AT3

AT3

AT3
5500

5500

5500

5500

5500
AT19

AT2

5500
3.D
3000

5500 5500 5500 5500 5500


5500
7 AT6
4000

14500

AT9
MESH T20@150 T&B (BW)
8200

500mm FOUNDATION SLAB


10000

AT8 AT3
AT13 AT3
AT11 AT3 AT22

10250
5500
AT8
3.E
5500

5500

AT25
AT24
AT8

AT24
6

6000
5500

10000
AT24
11500 AT10

10000
10000
AT53

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


8200

10000 AT3 AUTHORITY APPROVAL 0 08.08.2017 NS


AT18
Purpose of Issue Rev. Date Appoved
2500

AT44
4500

3000
AT39

AT43
5500

2800
5500
5500 AT9 Client:
AT3

AT20
5000
AT31

6000
30000

AT7 5500

3.F
2750

5 6000 5500
AT31 AT8 MEYDAN L.L.C
AT3 P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
AT3 AT3 E: info@dubairacingclub.com W: www.dubairacingclub.com
8200

AT44

AT24
AT15

3300

AT3 Principal Consultant:


2800

AT51

AT7
5000

AT24
3.G AT3

10000
AT31

5500
10000

5500
AT39 abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
AT24

5700 6500

10000
www.ae-7.com
AT51

2500

Hassanicor Building, 6th Floor, Al Barsha 1


AT24

PO Box 54115 Dubai, UAE


P: +971 4 3997758 F: +971 4 3997759
4
10000

3.H 5500 Sub-Consultant:


AT23
9500

AT3 5500
5500
AT6
5500 AT3
AT27

5500
AT3
6000

5500 AT3

8000
5500

AT26
AT3

8000
3.I 5000 4500 MESH T20@150 T&B (BW) Project Name:

AT26
AT3
5500

8000
2150

DUBAI WATER CANAL

AT26
AT3
3 5500
AT26

8000
3.J AT3
5500 SAFA A
AT3
AT23

8000

AT3
5500 DUBAI-UAE
AT26

5000
5500
8000
AT26

Project Description:
5500
8000
AT26

3.22 MIXED USE DEVELOPMENT


9550

8000
AT21

8200
(RETAIL & RESIDENTIAL)
8000

5500 8200
PLOT LIMIT LEGEND: PLOT 02 / 3435336
5500
2 8200 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
AT6 R.C COLUMN CONTINUE
3.21
8200
R.C WALL CONTINUE Drawing Title:
3.20
8200
R.C COLUMN / WALL STOPPING @ FLOOR LEVEL

BASEMENT 01 LEVEL - TOP


3.K 3.19
8200 R.C PLANTED COLUMN / WALL @ FLOOR LEVEL
3.18
8200
3.17
UPSTAND
REINFRORCEMENT PLAN - PART A
SLAB OPENING
12300
3.16
P.C. PLANTED COLUMN
PLOT LIMIT Scale Drawn Checked Approved Size
3.15 P.W. PLANTED WALL
C.I.P. CAST IN PLACE AA MA NS
1 P.T POST TENSION 1 : 150 A1
3.14 D.P DROP PANEL 08.06.2017 24.08.2017 24.08.2017

BASEMENT 01 LEVEL- TOP REINFORCEMENT PLAN - PART A


NOTE: Drawing Number Rev.
1. FOR BEAM SCHEDULE REFER TO DWG. 03-S6201 TO 03-S6202 & 04-S6201
1 SCALE 1 : 150
2. FOR SLAB REINFORCEMENT SCHEDULE REFER TO DWG. 00-S6301
3. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 TO 00-S5507
14011603-02-00-SRT0999a 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


1 1 N
SRT0999a SRT0999c
11

3.10 3.11 3.12 3.13 01 3.24 4.01 4.02 4.03 4.04 4.05 4.06 4.07

9500 2200 9500 10500 9400 10500 8200 1200 2300 4700 4800 3400

N
10 PLOT LIMIT KEY PLAN
3.A
4.A

4.B

AT5 AT6
AT5

2000

2000
8200

2000
B

AT6
7000 10750
AT22
9

8200
7500
AT3
AT18

5500
AT3
3.B
General Notes:
5500

AB4
1. DO NOT SCALE FROM THIS DRAWING.
4.C
11500 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
AT3 NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.
8200

4950
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT37 AT SITE.

8200
AT31
24000

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


8500

ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS


AND RELEVANT SECTIONS OF THE SPECIFICATION.
AB4

AT40
3.C

10300
AB4
AT38
AT43

AT38
2500
3000

11000
3000 1250
AT22 4.D

AT3
AT38
8200

2500
2250

AT19
7
11300 1250

8200
AT28 AT29
AB4

3500
AT8

5500

3.D

9000 8500

3000

3000
4.E
AT23 AT18
5000

AT3 AT3
AT8 AT22
AT13

AT13
8200

6 AT31

7000

7000
4100

AT34

6000

6000
AT46
15000 4750

9500
AT31 30000
AT30
4.F
AT3 AT3 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
AT3 AT8 AUTHORITY APPROVAL 0 08.08.2017 NS
7900

7000
AT8

3.E AT9 Purpose of Issue Rev. Date Appoved


AT25

AT5
5600

Client:

4000
MESH T20@150 T&B (BW)

AT9
AT45

13000 8000
4750

AT35 AT3 AT3

AT36
AT35

4000

9500

AT35
9500

9500

9500
5 3.G
4.G 4000 MEYDAN L.L.C
8200

AT3
P.O. Box 9305, Dubai , UAE.

AT3

5500
5500
2200

AT3 AT3 T: +9714 3270000 F: +9714 3270007


AT44 6000 E: info@dubairacingclub.com W: www.dubairacingclub.com
AT43

2800

AT25 4.H Principal Consultant:

27500
AT20

5000 5500 5500


5500 5500 5500 5500
AT31
6700
9500

3.F
MESH T20@150 T&B (BW) abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
25000

500mm FOUNDATION SLAB www.ae-7.com


Hassanicor Building, 6th Floor, Al Barsha 1
AT54

8500

AT8 PO Box 54115 Dubai, UAE


AT3
9500

AT3 AT3 AT3 AT3 P: +971 4 3997758 F: +971 4 3997759


4
AT3 AT3 Sub-Consultant:
5500
AT22
8200

AT8

5500

AT3

AT3
5500

5500
3.I 8000
5500

AT26
AT3

AT3
5500

5500
2150

7500
5500
5500 5500 5500 5500
3.J
4.J
5500 5500 5500
3.H AT31 AT1
5500 Project Name:

2500
AT3

AT14
AT1
5500
DUBAI WATER CANAL

2500
AT14
AT8 AT3
3000

3
AT14

5500
AT 41

AT3 SAFA A
6000

AT3
3000
9550

AT14
8000

5500
AT33

DUBAI-UAE
8000

3000
AT14
AT26

8000
5500 Project Description:
5500
MIXED USE DEVELOPMENT
PLOT LIMIT
LEGEND: (RETAIL & RESIDENTIAL)
3.K PLOT 02 / 3435336
R.C COLUMN CONTINUE
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
R.C WALL CONTINUE
Drawing Title:
R.C COLUMN / WALL STOPPING @ FLOOR LEVEL
12300

BASEMENT 01 LEVEL - TOP


R.C PLANTED COLUMN / WALL @ FLOOR LEVEL
8200 3.23 UPSTAND

SLAB OPENING REINFRORCEMENT PLAN - PART B


3.22
P.C. PLANTED COLUMN
3.21 P.W. PLANTED WALL
C.I.P. CAST IN PLACE Scale Drawn Checked Approved Size
P.T POST TENSION AA MA NS
1 D.P DROP PANEL 1 : 150 A1
08.06.2017 24.08.2017 24.08.2017
NOTE:
BASEMENT 01 LEVEL- TOP REINFORCEMENT PLAN - PART B 1. FOR BEAM SCHEDULE REFER TO DWG. 03-S6201 TO 03-S6202 & 04-S6201
Drawing Number Rev.
1 2. FOR SLAB REINFORCEMENT SCHEDULE REFER TO DWG. 00-S6301
SCALE 1 : 150 3. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 TO 00-S5507
14011603-02-00-SRT0999b 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


1
SRT0999b
N
11

Q
4.05 4.06 4.07 4.08 4.09 4.10 4.11 4.12 4.13 4.144.15 4.16 4.17

4800 3400 8200 9900 8200 4100 3400 700 8200 600 2200 9500

N
10 KEY PLAN
PLOT LIMIT
4.A
PLOT LIMIT

4.B

C
8200

AT14
2500
2500
General Notes:
4.C

AT48

AT47

AT45
1. DO NOT SCALE FROM THIS DRAWING.

5500
7000 5000
AT18 AT13 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.
MESH T20@150 T&B (BW)
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8200

8 AT SITE.

12000

7500
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
17000 2500 ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

AT49

AT42
AT31

4.D

20000
7

AT51
8200

AT22 AT27

5500
AT27
5500
AT22
AT14
AT4
AT52

5000

4.E
AT50

3000

AT52

AT5
5400 5500 6000
4000 2500
AT51 AT51

AT52
AT22

5500

5500
AT52
4100

5000

9500
6000

AT42
AT3 4000 13000
AT46 3000 6000 3000 AT9
6 AT17
9000

AT5 AT52
9500

AB38

10500

6000
4.F

AT9
AT8
AT3 AT8
4000 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
AT9

42000
4000 AUTHORITY APPROVAL 0 08.08.2017 NS
AT22

AT39
Purpose of Issue Rev. Date Appoved

AT2
5600

AT9

4000

Client:
AT3
4000
AT36

AT8 AT8
AT35

AT36

AT13

9500
9500

9500
9500

9500

4.G

6000

AT3
AT41
5
5500

AT3
MEYDAN L.L.C
AT3
AT8

5500
5500
2200

AT46 9000 2500 P.O. Box 9305, Dubai , UAE.


T: +9714 3270000 F: +9714 3270007
4.H E: info@dubairacingclub.com W: www.dubairacingclub.com
5500 5500 5500 5500 5500
5500 5500 Principal Consultant:

18000

AT9
500mm FOUNDATION SLAB MESH T20@150 T&B (BW)
15000

10500
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com
AT3 AT3 AT8
9500

AT3 AT3 AT3 AT12 Hassanicor Building, 6th Floor, Al Barsha 1


AT8 AT3 AT23
PO Box 54115 Dubai, UAE
AT3 AT9 P: +971 4 3997758 F: +971 4 3997759
4

10000
10000

Sub-Consultant:
AT33

AT26
AT3

AT26
5500

AT26

AT33
7000
7000
AT26

7000
7000
7500
7500

5500 5500 5500 5500 5500 21000


5500
4.J
5500
AT1
2500
AT14

Project Name:
PLOT LIMIT
3
DUBAI WATER CANAL
PLOT LIMIT SAFA A
DUBAI-UAE

Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
LEGEND:
PLOT 02 / 3435336
2 R.C COLUMN CONTINUE BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
R.C WALL CONTINUE
Drawing Title:
R.C COLUMN / WALL STOPPING @ FLOOR LEVEL

R.C PLANTED COLUMN / WALL @ FLOOR LEVEL BASEMENT 01 LEVEL - TOP


UPSTAND
REINFRORCEMENT PLAN - PART C
SLAB OPENING

P.C. PLANTED COLUMN


P.W. PLANTED WALL Scale Drawn Checked Approved Size
C.I.P. CAST IN PLACE AA MA NS
1 P.T POST TENSION 1 : 150 A1
D.P DROP PANEL 08.06.2017 24.08.2017 24.08.2017

BASEMENT 01 LEVEL- TOP REINFORCEMENT PLAN - PART C NOTE:


Drawing Number Rev.
1 1. FOR BEAM SCHEDULE REFER TO DWG. 03-S6201 TO 03-S6202 & 04-S6201
2. FOR SLAB REINFORCEMENT SCHEDULE REFER TO DWG. 00-S6301
14011603-02-00-SRT0999c
SCALE 1 : 150
3. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 TO 00-S5507 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


N
11

N
10 KEY PLAN

1 1 1 1
SR1000b SR1000a SR1000c SR1000b
General Notes:
3.01 3.02 3.03 3.04 3.05 3.06 3.07 3.08 3.09 3.10 3.11 3.12 3.13 01 3.24 4.01 4.02 4.03 4.04 4.05 4.06 4.07 4.08 4.09 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17
PLOT LIMIT 1. DO NOT SCALE FROM THIS DRAWING.
9500 2200 9500 7750 8200 8200 8200 8200 5650 9500 2200 9500 10500 9400 10500 8200 12002300 9500 3400 8200 9900 8200 4100 3400 700 8200 600 9500
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
2200 NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.
3.A
4.A PLOT LIMIT 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
4.B SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.
8200

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT

8200
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.
3.B

4.C
8200

8200
3.C
LIFT
4.D
8200

8200
3.D

4.E
8200

4100
4.F
3.E

5600
4.G
8200

2200
6 LIFT LIFT 4.H

3.F

9500
8200

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


LIFT LIFT
3.G AUTHORITY APPROVAL 0 08.08.2017 NS
Purpose of Issue Rev. Date Appoved
4.J
3.H Client:
9500

PLOT LIMIT

5 3.I
2150

3.J
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com
12300
9550

8200
Principal Consultant:
3.23
8200
8200 3.22
8200 3.21
8200 3.20
3.K 3.19
8200
8200 3.18 abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
3.17 www.ae-7.com
12300 3.16 Hassanicor Building, 6th Floor, Al Barsha 1
PLOT LIMIT
3.15 PO Box 54115 Dubai, UAE
3.14 P: +971 4 3997758 F: +971 4 3997759
4
Sub-Consultant:

Project Name:

3
DUBAI WATER CANAL
SAFA A
DUBAI-UAE

Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
PLOT 02 / 3435336
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
LEGEND:
Drawing Title:
R.C COLUMN CONTINUE
R.C WALL CONTINUE
R.C COLUMN / WALL STOPPING @ FLOOR LEVEL GROUND LEVEL - REINFORCEMENT
R.C PLANTED COLUMN / WALL @ FLOOR LEVEL
UPSTAND PLAN - OVERALL
SLAB OPENING

P.C. PLANTED COLUMN


P.W. PLANTED WALL Scale Drawn Checked Approved Size
C.I.P. CAST IN PLACE AA MA NS
1 P.T POST TENSION 1 : 350 A1
GROUND LEVEL - REINFORCEMENT PLAN - OVERALL D.P DROP PANEL 08.06.2017 24.08.2017 24.08.2017
1 SCALE 1 : 350
NOTE:
1. FOR BEAM SCHEDULE REFER TO DWG. 03-S6201 TO 03-S6202 & 04-S6201
Drawing Number Rev.
2. FOR SLAB REINFORCEMENT SCHEDULE REFER TO DWG. 00-S6301
3. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 TO 00-S5507 14011603-02-00-SR1000 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

3.01 3.02 3.03 3.04 3.05 3.06 3.07 3.08 3.09 3.10
SR1000b
3.11 3.12
DUBAI MUNICIPALITY STAMP:
PLOT LIMIT
9500 2200 9500 7750 8200 8200 8200 8200 5650 9500 2200
N
11
PLOT LIMIT
Q

3AT31
3AT10

1500
3.A 3AT31

3AT19
3AB6 3AB6
1500

5000

3AT30

2800
2800
6000 3AT30
MESH T25@150 T&B (BW)
3AT4
MESH T20@150 T&B (BW)
300mm. THICK C.I.P SLAB 4000 N
8200

10 10100 KEY PLAN

3AB10
3AT13 3AT2 3AT2 3AT2 3AT2 3AT13 3AT13 3AT4

7400

2000
3AT17
3AT21
3AT8

3AT2
A

3AT2

3AT2

3AT2

3AT2

3AT2

3AT2

3AT2
6000

6000

6000

6000

6000

6000

6000
3AT17

3AT10
3AT4
6000

6000

6000
3.B

4000
3AT 13 3AT9
3000 6000 6000 6000 6000
6000 3000 3000 6000 3000 3000
3AB6

3AB1
9

15000
8200

3AT18
3300 10000
3AT13
3AT2 3AT2 3AT2 3AT2 3AT13 3AT13 3AT4 3AT13 3AT9
General Notes:
6600

6600

8550
3AT27

3AT28

3AB6

6000
3AT2
1. DO NOT SCALE FROM THIS DRAWING.

6000

3AT10
3AT2

3AT2

3AT2

3AT2

3AT2

3AT2

3AT4

3AT2
6000

6000

6000

6000

6000

6000

6000

6000
3.C 1000
3AT18 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
3AT29 NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.
3000
6000 6000 6000 6000 3000 3000 6000 3000 3000
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 11700 AT SITE.
8200

3AT8 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


3AB8

ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS


AND RELEVANT SECTIONS OF THE SPECIFICATION.
3AT2 3AT2 3AT2 3AT2 3AT13 3AT13
3AT26

3AT20 3AT13

3AT13
MESH T25@150 T&B (BW)

3000

3000
3AT25
3000 400mm. THICK C.I.P SLAB
6000

3000

3AT2

3AT2

3AT2

3AT2

3AT2
6000

6000

6000

6000
3AT2

6000
3.D

3AT13
3AT2
14000
3AT17

3AT13
3000

3000
6000 6000 6000 6000
4000 3000 3000 3500
7 3000

MESH T25@150 T&B (BW)


11700
8200

350mm. THICK C.I.P SLAB


3AB9

3AT13
3AT2
3AT20 3AT9 3AT2 3AT2 3AT2 3AT13 3AT13 3AT7

3000
3AT10

3000 3000

5000
3AT25

6000

5000
6000

5000

3AT12
3AT26
6000

3000

6000

3AT12

3AT12
3.E

3AT2
3AT9

3AT2
3AT17

3AT2

3AT1
3000
3000
3AT9

6 6000
4000 3AT17 6000 6000 6000 4000 3000
4000

3000 3000

2750
3AT1
3AT2
MESH T20@150 T&B (BW)
3AT2
8200

3AT8 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


MESH T20@150 T&B (BW)
3AT18

3AT1
3AT2 LIFT LIFT AUTHORITY APPROVAL 0 08.08.2017 NS
1200

3AT13

3AB2
13000

4000
2500 3500 Purpose of Issue Rev. Date Appoved

3AT1

3500
3AT20 300mm. THICK C.I.P SLAB 3AT2

8000
3AT11

6000
4000
3AT17 Client:
6000 8000

3AT1
3AT25
3AT2
3AT1
4500

3AB2
3AT4

6000
4000
3AT26

6900
6000

3000

3.F

3AT10
3AT8 6000 3AT2

3AB3
3AT17

3AT1
3000
MEYDAN L.L.C

9500
3AT4
)
4000 150 T&B (BW 8000 P.O. Box 9305, Dubai , UAE.
MESH T25@
6000

LIFT LIFT 3AT4 T: +9714 3270000 F: +9714 3270007


8200

W) E: info@dubairacingclub.com W: www.dubairacingclub.com
150 T&B (B ICK C.I.P SL
AB
3500

11350
MESH T20@ 3AT4 400mm. TH Principal Consultant:

9000
3AT8

3AT7
AB
3.G ICK C.I.P SL 3AT4
300mm. TH

9000
3AT20
3AB8

3AT6
3AT4

2150
3500

9000
3AT6
3AT20

4000

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


3AT4

9000
3AT18

4000 www.ae-7.com
16500
3AT6

Hassanicor Building, 6th Floor, Al Barsha 1


9000

3AT21 PO Box 54115 Dubai, UAE


6000
1500

3AT6

3.H P: +971 4 3997758 F: +971 4 3997759


4 2500 6000 150 T&B (BW
)
MESH T20@
9000

Sub-Consultant:
9500

3AT6
3AT22

3AT2 6000
4500

AB
ICK C.I.P SL
300mm. TH 3AT2
3AT13 6000
3AT21

4000
3AT22

3AT2

9550
6000

6000

3AT1
3AT2

5000

4000
6000 3AT4 6000
1500
2500

3AT1
8000
1500

4000
3AT4 6000
3AT24

3AT3
3.I 3AT22 6000
Project Name:

4000
3AT4 6000
2150

3AT3

3AT17
4000

3AB7 3AT4 6000 DUBAI WATER CANAL


3AT3

3 3.J
4000

3AT4 6000 SAFA A


3AT3

3AB4
4000

3AT2 6000
13000

DUBAI-UAE
3AT3

)
150 T&B (BW 41000
MESH T20@
4000

6000
3AT1

6000 Project Description:


8200
3AT23 3.22
MIXED USE DEVELOPMENT
9550

8200
4000

300mm. TH
ICK C.I.P SL
AB
8200 LEGEND: (RETAIL & RESIDENTIAL)
PLOT LIMIT
3AT22

MESH T16@
150 T&B (BW
)
8200
PLOT 02 / 3435336
R.C COLUMN CONTINUE
2 1500
8200 3.21
BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
1500

R.C WALL CONTINUE


3AT22 8200 3.20 Drawing Title:
R.C COLUMN / WALL STOPPING @ FLOOR LEVEL
3.K 3.19
8200
GROUND LEVEL - REINFORCEMENT
R.C PLANTED COLUMN / WALL @ FLOOR LEVEL
3.18 UPSTAND
12300
3.17 SLAB OPENING PLAN - PART A
3.16 P.C. PLANTED COLUMN
PLOT LIMIT P.W. PLANTED WALL
3.14 3.15 Scale Drawn Checked Approved Size
C.I.P. CAST IN PLACE
P.T POST TENSION AA MA NS
1 D.P DROP PANEL 1 : 150 A1
08.06.2017 24.08.2017 24.08.2017
GROUND LEVEL - REINFORCEMENT PLAN - PART A NOTE:

1
1. FOR BEAM SCHEDULE REFER TO DWG. 03-S6201 TO 03-S6202 & 04-S6201
Drawing Number Rev.
2. FOR SLAB REINFORCEMENT SCHEDULE REFER TO DWG. 00-S6301
SCALE 1 : 150 3. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 TO 00-S5507
14011603-02-00-SR1000a 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


N
11

1 1 Q
SR1000a SR1000c

3.10 3.11 3.12 3.13 01 3.24 4.01 4.02 4.03 4.04 4.05 4.06 4.07

9500 2200 9500 10500 9400 10500 8200 1200 2300 4700 4800 3400

PLOT LIMIT
N
10 KEY PLAN
3.A
3AB6
4.A

4AT12
4AT12 4AT16

2800

1750
4AT15
4AT12

3000
3000
MESH T25@150 T&B (BW) MESH T20@150 T&B (BW)

4000
4.B

3000
3AT4
3000 9000 4AT12

3AT8
8200

11900 B
8850 3900 8850
2000

4AB6
4AB5

4AB5

8200
3AT21
9
3AT8
3AT2
4AT12 4AT7 4AT12

4000
MESH T20@150 T&B (BW)

3AT10

3AT14

4000
6000
3.B

4AT10
4AT10

4AT6
300mm. THICK C.I.P SLAB MESH T16@150 T&B (BW)
4000

6000
4000
3AT 13 3AT9
3000 General Notes:
3000 3000 9000
3000 3000

4AB7
4.C 1. DO NOT SCALE FROM THIS DRAWING.

3AT8
11000
3AB1 8700 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
15000
8200

MESH T20@150 T&B (BW) BY THE ENGINEER.

300mm. THICK C.I.P SLAB 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
3000 15500
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 3AT13 3AT9 AT SITE.

8200
6500
4AT16 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
6000

4AT16 4AT8 ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS

4AT14

4AT16

4000
AND RELEVANT SECTIONS OF THE SPECIFICATION.
3AT10

3AT17
3AT2

6000

3.C

4AT10

4AT2
4000

13400
3000 3000 2800 3000
LIFT 4.D
3AT9
8200

4AB8

7850
3750

7020
7
3AT17 21600
3AT15 3AT13

8200
MESH T25@150 T&B (BW)
3000

6000

400mm. THICK C.I.P SLAB 1950 4AB9 4AB9


3AT2

3AT2

3.D
3AT13

3000

3AT7 4AT6
3500 5500 3000
4.E

4AT8

4000
4AT6
6000

4AT6
8200

300mm. THICK C.I.P SLAB

4100
6 MESH T20@150 T&B (BW)

6000
MESH T16@150 T&B (BW)
4AB4
3AT13

3AT13 3AT7 300mm. THICK C.I.P SLAB 3AT13


4.F 6000
3000

4AB1 4AB1
3000 2000 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
4AT6
6000

MESH T20@150 T&B (BW) AUTHORITY APPROVAL 0 08.08.2017 NS


3AT2
6000

3.E
Purpose of Issue Rev. Date Appoved

4AB1
350mm. THICK C.I.P SLAB
3AT2

5600
3AT1

Client:
3000 9000 3000
MESH T16@150 T&B (BW)

4AT3
2750

4AT14 4AT6

2000

9000
21400
3AT2
250mm. THICK C.I.P SLAB 4AT4 4AT4 4AT4

4AT14

4AT6
3.G 2000 2000
5 4.G

4AT2
MEYDAN L.L.C
6000
8200

4AT2

4AT7
6000

6000
6000

2200
LIFT LIFT P.O. Box 9305, Dubai , UAE.

4AT4
3AT13 4AT8
T: +9714 3270000 F: +9714 3270007
3500

MESH T16@150 T&B (BW) E: info@dubairacingclub.com W: www.dubairacingclub.com

4AT8
3AT11 4.H 3000 3000

4000
6000
3AT9

6000 6000 Principal Consultant:


21000

21000
4000
3000 2500 350mm. THICK C.I.P SLAB
6900
3AT16
6000

3.F
3AT10
3AB3
3AT1

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


4AT1

4AT2

3AT9
9500

9500
www.ae-7.com
) MESH T16@150 T&B (BW)
150 T&B (BW 8000 5000 3000 4AT6 4AT6 4AT6 Hassanicor Building, 6th Floor, Al Barsha 1
1380 2000 MESH T20@150 T&B (BW)
MESH T25@ 4AT8 PO Box 54115 Dubai, UAE
300mm. THICK C.I.P SLAB

4AT8

4AT8

4AT8
P: +971 4 3997758 F: +971 4 3997759
4 ICK C.I.P SL
AB

4AT8
6000

400mm. TH

4000

4000

4000

4000
8200

Sub-Consultant:
4AT5 4AT5 6000 6000 6000

4AT4
10000 4000
3.I MESH T16@150 T&B (BW)
4AT2

4AT2
6000

6000
2150

250mm. THICK C.I.P SLAB 4AT4 4AB4


10000

4AT3
2000
3AB5 3000 3000
3.J 2000 2000
4.J
3AB5

VAR.
MESH T16@150 T&B (BW)
3.H )
150 T&B (BW MESH T20@150 T&B (BW)
MESH T20@ 3AT5 350mm. THICK C.I.P SLAB Project Name:
4AT2

250mm. THICK C.I.P SLAB


AB
ICK C.I.P SL DUBAI WATER CANAL
4000

300mm. TH 3AT2 MESH T20@150 T&B (BW)


3AT5

3
4000 SAFA A
4000

3AT2
9550

2000 MESH T12@150 T&B (BW)


3AT1

300mm. THICK C.I.P SLAB


4000

6000 DUBAI-UAE

Project Description:
)
150 T&B (BW
MESH T16@ 250mm. THICK C.I.P SLAB
MIXED USE DEVELOPMENT
PLOT LIMIT

LEGEND: (RETAIL & RESIDENTIAL)


3.K
PLOT 02 / 3435336
R.C COLUMN CONTINUE
2
12300
BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
R.C WALL CONTINUE
Drawing Title:
8200 R.C COLUMN / WALL STOPPING @ FLOOR LEVEL

GROUND LEVEL - REINFORCEMENT


R.C PLANTED COLUMN / WALL @ FLOOR LEVEL
3.23
UPSTAND

3.22 SLAB OPENING PLAN - PART B


3.21 P.C. PLANTED COLUMN
P.W. PLANTED WALL
C.I.P. CAST IN PLACE Scale Drawn Checked Approved Size
P.T POST TENSION AA MA NS
1 D.P DROP PANEL 1 : 150 A1
08.06.2017 24.08.2017 24.08.2017
NOTE:
1. FOR BEAM SCHEDULE REFER TO DWG. 03-S6201 TO 03-S6202 & 04-S6201
Drawing Number Rev.
GROUND LEVEL - REINFORCEMENT PLAN - PART B 2. FOR SLAB REINFORCEMENT SCHEDULE REFER TO DWG. 00-S6301

1 SCALE 1 : 150
3. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 TO 00-S5507
14011603-02-00-SR1000b 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


N
11

1
Q
SR1000b

4.05 4.06 4.07 4.08 4.09 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17

4800 3400 8200 9900 8200 4100 3400 700 8200 600 2200 9500

N
10 KEY PLAN
PLOT LIMIT
4.A

4AT12

4AT17
PLOT LIMIT

1500
3000
4.B 4AT17

3000
4AT12 4AT13 4AT15 4AT15
1500

4AT12
4AT12

4AT15

4AT15

3000
4AT8

4500
4000

3500

4500
6500 4500 4500
C

9
8200

5000 MESH T20@150 T&B (BW)


4AT12 MESH T20@150 T&B (BW)

4AB7
350mm. THICK C.I.P SLAB 300mm. THICK C.I.P SLAB
4000
4AT10

4AT13 General Notes:


3000 4AT8
1. DO NOT SCALE FROM THIS DRAWING.
4.C

4AT2

4000
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS

6500
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED

4AT8
6500 BY THE ENGINEER.
MESH T20@150 T&B (BW) 4000
4AT12 MESH T20@150 T&B (BW)

4AT1
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
300mm. THICK C.I.P SLAB SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 350mm. THICK C.I.P SLAB

9450
AT SITE.
3000
8200

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS

4AT12
4AT8 AND RELEVANT SECTIONS OF THE SPECIFICATION.
4000

3000 4000
4AT2

4AT12

6000
3000

6000
4.D

4AT9
4AT6
3000 5750

4AT12
4AB1
7 4AT8

4AB3
8200

2000 MESH T20@150 T&B (BW)


300mm. THICK C.I.P SLAB

4AB3
12050
MESH T20@150 T&B (BW)

4AT6
4AT6 4AT7
350mm. THICK C.I.P SLAB
4.E
4AT8

4AT8
4000

4000
11570
6000 6200 2800

6 MESH T20@150 T&B (BW)


4100

350mm. THICK C.I.P SLAB


4AB4 4AB4
1000 1000 1000
4AB4 4AB4
4.F 0
100% CONSTRUCTION DOCUMENTS FOR TENDER 24.08.2017 NS
4AT6 4AT6 4AT6 4AT6 AUTHORITY APPROVAL 0 08.08.2017 NS
4AT6

1600 1400
Purpose of Issue Rev. Date Appoved
Client:
5600

6000
4AT2
6000

MESH T20@150 T&B (BW) MESH T20@150 T&B (BW)

21400

4AT3
4AT6 350mm. THICK C.I.P SLAB
9000

4AT6 4AT6 4AT6


21400

21400

21400
9000

4000 2000 2100 300mm. THICK C.I.P SLAB


5 2000 2000
4.G MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
4AT7

6000

6000
4AT6
6000
6000
2200

4AT7

4AT7
T: +9714 3270000 F: +9714 3270007

4AT4
4AT7 4AT8

4AT7
4AT7

E: info@dubairacingclub.com W: www.dubairacingclub.com

4AT6
4AT6

4AT8
4AT6

4.H

4000
6000 Principal Consultant:
6000 4000

2300
4000 2000 4000 2150 1650 4350 4000

4AB1
8750
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
12000 www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
4AT6 4AT6 MESH T20@150 T&B (BW) 4AT6 4AT6 4AT6 4AT6 PO Box 54115 Dubai, UAE
9500

P: +971 4 3997758 F: +971 4 3997759


4 300mm. THICK C.I.P SLAB
4AT8
4AT8

4AT8

4AT8

4AT8

4AT8

4AT8
Sub-Consultant:

4AT8
4000

4000

4000

4000

4000

4000

4000
4AB2
6000 6000 6000 6000 6000 6000
4000

4AT4
4AB4 4AB4
2000 2000
1000 4AB4 1000

4AT3
VAR.

4.J
VAR.
VAR.

MESH T20@150 T&B (BW) Project Name:

3
DUBAI WATER CANAL
PLOT LIMIT
SAFA A
PLOT LIMIT
DUBAI-UAE

Project Description:

MIXED USE DEVELOPMENT


LEGEND: (RETAIL & RESIDENTIAL)
PLOT 02 / 3435336
R.C COLUMN CONTINUE
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
R.C WALL CONTINUE
Drawing Title:
R.C COLUMN / WALL STOPPING @ FLOOR LEVEL

GROUND LEVEL - REINFORCEMENT


R.C PLANTED COLUMN / WALL @ FLOOR LEVEL

UPSTAND

SLAB OPENING PLAN - PART C


P.C. PLANTED COLUMN
P.W. PLANTED WALL
C.I.P. CAST IN PLACE Scale Drawn Checked Approved Size
GROUND LEVEL - REINFORCEMENT PLAN - PART C P.T POST TENSION AA MA NS
1 1 SCALE 1 : 150
D.P
NOTE:
DROP PANEL 1 : 150
08.06.2017 24.08.2017 24.08.2017
A1

1. FOR BEAM SCHEDULE REFER TO DWG. 03-S6201 TO 03-S6202 & 04-S6201


Drawing Number Rev.
2. FOR SLAB REINFORCEMENT SCHEDULE REFER TO DWG. 00-S6301
3. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 TO 00-S5507
14011603-02-00-SR1000c 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

900 900 750 750 DUBAI MUNICIPALITY STAMP:


2
S5105
900 900 1800
750 750
750 750

1250
11

1250
750 1900 750

750
1

900

750
2

750
1 S5104 S5104
1

1720
2 S5105

1885
S5104
S5104

1250
S5104

750
750

1250
900

750
PC1 + PC7 PC2 + PC6 PC3 PC4 + PC5
N
10 1 2 3 4
KEY PLAN
SCALE 1 : 50 SCALE 1 : 50
SCALE 1 : 50 SCALE 1 : 50 PC8 + PC9 PC10 + PC11 PC12
8 SCALE 1 : 50
10 SCALE 1 : 50
12 SCALE 1 : 50
3.04

900 600 300

900
3.C
9

General Notes:
1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED

4200
BY THE ENGINEER.
3.04 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
900 700 200 SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.
900

3.20 900 600


750 750

3
750

S5104
2400

7
2000

1
3 S5104
4000

S5104 750 1900 750


1
S5104
450

900 2300 900


3.I 1

1100
2300

S5104

6 -4.500 SSL 750 2650 750


1550

900
-4.500 SSL

750
3.D

1100
2
3.B 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
S5104
900

AUTHORITY APPROVAL 0 08.08.2017 NS

900
900

750
Purpose of Issue Date Appoved
600

Rev.
3.J Client:
150

900 700 200 900 600 300

5 PC16
PC13 PC14 PC15 16 PC17 PC18 MEYDAN L.L.C
13 14 15 SCALE 1 : 50 17 SCALE 1 : 50 18
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
SCALE 1 : 50 SCALE 1 : 50 SCALE 1 : 50 SCALE 1 : 50 E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
Sub-Consultant:

4
S5105
4.09

1850 2865 2735 150 25 1825

Project Name:
4.14 4.15
4.07
3
750 750 650 500 100 650 DUBAI WATER CANAL
750

4.F
SAFA A

1000
4.14 4.15 DUBAI-UAE
1050
900

750 600 600 150 750 Project Description:


4.E
MIXED USE DEVELOPMENT

750
900

-6.300 SSL 1
(RETAIL & RESIDENTIAL)
750

1060

S5104
PLOT 02 / 3435336
1655

4.E -4.500 SSL


1150
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
750

-4.500 SSL
440
1400

4.C Drawing Title:


600

1
750

2
FOUNDATION DETAILS - 01
S5104
S5105
1575

1895
900

975

750

-4.500 SSL

Scale Drawn Checked Approved Size


900 25 875
AA MA NS
835 515 600 900
1 1 : 50 A1
08.06.2017 24.08.2017 24.08.2017

PC19 PC20 PC21 PC22 Drawing Number Rev.


19 20 21 22 14011603-02-00-S5101
SCALE 1 : 50 SCALE 1 : 50 SCALE 1 : 50 SCALE 1 : 50 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


3.12 3.13
660 240 2810 1000 2000 3300 150 1550
11

900
3.10 3.11

525 375 900 625 3200 3200 200 700

4
900

S5104 N
10 KEY PLAN
150

3900
750

-5.000 SSL
1050

9 3.C

25
1

900
S5103

General Notes:
3100

-6.300 SSL 1. DO NOT SCALE FROM THIS DRAWING.

1375
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
-6.300 SSL NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
850

AND RELEVANT SECTIONS OF THE SPECIFICATION.

2300
3.F
1050

900
PC23 PC24
23 SCALE 1 : 50
24 SCALE 1 : 50

6 3.03 3.04
1
S5105
0 900 2300 3000 2700 600 1700 900
100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
AUTHORITY APPROVAL 0 08.08.2017 NS
Purpose of Issue Rev. Date Appoved
Client:
900

900

5
4.01 4.02 4.03 MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
4.C E: info@dubairacingclub.com W: www.dubairacingclub.com
1900

1900

5 Principal Consultant:
S5104

1175
900 2300 150 2150 2300 2300 1450 850 350 550

3.F abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


400

www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
700

PO Box 54115 Dubai, UAE


P: +971 4 3997758 F: +971 4 3997759
4
Sub-Consultant:
1900

2300

2500

Project Name:

3 -0.400 SSL
DUBAI WATER CANAL
SAFA A
3100

-6.300 SSL DUBAI-UAE


2300

Project Description:
2500

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
PLOT 02 / 3435336
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
1850

1850

700

Drawing Title:

FOUNDATION DETAILS - 02

Scale Drawn Checked Approved Size


AA MA NS
1 1 : 50 A1
08.06.2017 24.08.2017 24.08.2017
PC25 PC26
25 1 Drawing Number Rev.
SCALE 1 : 50 SCALE 1 : 50
14011603-02-00-S5102 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

4.16 4.17
DUBAI MUNICIPALITY STAMP:
3.01 3.02
5
S5104
11 750 550 1750 550 1750 2300 3 2300 750 1550 900
900 2300 100 2200 2300 2300 2300 400 500
S5105

900
750
750

N
10 KEY PLAN

2400
-4.500 SSL
2500

-0.400 SSL

1975
9
750

750
4.D

3.C General Notes:


750

750

425
1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS

900
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.
PC27 PC28
27 SCALE 1 : 50
28 SCALE 1 : 50
2
S5105
900 900

7
900
900

PC29 + PC30
6 30 SCALE 1 : 50

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


FOR REINF. REFER FOR REINF. REFER AUTHORITY APPROVAL 0 08.08.2017 NS
TO CORE WALL DETAILS TO CORE WALL DETAILS
Purpose of Issue Rev. Date Appoved
FOR REINF. REFER FOR REINF. REFER
TO REINF. PLAN -4.50 S.S.L -4.50 S.S.L TO REINF. PLAN Client:

500
Ld
5 Ld
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:

1300
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
1500

www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
AS PER PILE CAP SCHEDULE P: +971 4 3997758 F: +971 4 3997759
4 Ld
T16@300 RINGS Sub-Consultant:
Ld -6.30 S.S.L Ld
2T32 @100mm

50MM PROTECTION Project Name:


SCREED
WATER PROOFING AS
DUBAI WATER CANAL

1900
PER PROJECT SPECT.
3
1800

75mm BLINDING SAFA A


COMPACTED FILL
95% PROCTOR TEST DUBAI-UAE
WATER PROOFING
AS PER SPEC.
PROTECTION BOARD Project Description:
BLOCK WORK 200mm MIXED USE DEVELOPMENT
50MM HIGH STRENGTH (RETAIL & RESIDENTIAL)

100
FLOWABLE EPOXY GROUT
PLOT 02 / 3435336
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)

50MM PROTECTION
Drawing Title:
SCREED
WATER PROOFING AS PILE REINFORCMENT AS PER THE PILING CONTRACTOR
PER PROJECT SPECT. COMPLYING WITH THE PROJECT SPECIFICATIONS

75mm BLINDING
FOUNDATION DETAILS - 03
COMPACTED FILL
95% PROCTOR TEST

Scale Drawn Checked Approved Size


SECTION 1 As AA MA NS
1 1 SCALE 1 : 25
indicated 08.06.2017 24.08.2017 24.08.2017
A1

AS PER PLAN AS PER PLAN AS PER PLAN AS PER PLAN AS PER PLAN Drawing Number Rev.

14011603-02-00-S5103 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

AS PER PLAN
DUBAI MUNICIPALITY STAMP:
AS PER PLAN AS PER PLAN

11 FOR COLUMN REINF. DETAILS


REFER TO COLUMNS OR WALLS SCHEDULES

FOR COLUMN / WALL REINF. DETAILS


FOR COLUMN / WALL REINF. DETAILS REFER TO COLUMN SCHEDULE
AS PER PILE CAP SCHEDULE
REFER TO COLUMN SCHEDULE
T16@300 RINGS FOR REINF. REFER
AS PER PLAN TO REINF. PLAN
T16@300 RINGS FOR REINF. REFER
AS PER PLAN TO REINF. PLAN
T16@300 RINGS FOR REINF. REFER
AS PER PLAN TO REINF. PLAN

AS PER RELATED PILE CAP SCHEDULE


Ld
Ld
N

AS PER RELATED PILE CAP SCHEDULE


10 KEY PLAN

AS PER RELATED PILE CAP SCHEDULE


WATER PROOFING
AS PER SPEC.
WATER PROOFING
PROTECTION BOARD 50MM PROTECTION AS PER SPEC.
WATER PROOFING
50MM PROTECTION SCREED
AS PER SPEC. PROTECTION BOARD
SCREED BLOCK WORK 200mm WATER PROOFING AS
WATER PROOFING AS PROTECTION BOARD PER PROJECT SPECT.
BLOCK WORK 200mm
PER PROJECT SPECT.

100
BLOCK WORK 200mm 50MM HIGH STRENGTH 75mm BLINDING
FLOWABLE EPOXY GROUT
75mm BLINDING 50MM HIGH STRENGTH

100
9 COMPACTED FILL
FLOWABLE EPOXY GROUT
50MM HIGH STRENGTH 95% PROCTOR TEST

100
COMPACTED FILL
95% PROCTOR TEST FLOWABLE EPOXY GROUT

50MM PROTECTION
SCREED General Notes:
WATER PROOFING AS 50MM PROTECTION
PILE REINFORCMENT AS PER THE PILING CONTRACTOR SCREED
50MM PROTECTION PER PROJECT SPECT. 1. DO NOT SCALE FROM THIS DRAWING.
COMPLYING WITH THE PROJECT SPECIFICATIONS
SCREED WATER PROOFING AS PILE REINFORCMENT AS PER THE PILING CONTRACTOR
75mm BLINDING PER PROJECT SPECT. COMPLYING WITH THE PROJECT SPECIFICATIONS 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
WATER PROOFING AS PILE REINFORCMENT AS PER THE PILING CONTRACTOR NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
PER PROJECT SPECT. COMPLYING WITH THE PROJECT SPECIFICATIONS COMPACTED FILL 75mm BLINDING BY THE ENGINEER.
95% PROCTOR TEST
75mm BLINDING COMPACTED FILL 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
COMPACTED FILL 95% PROCTOR TEST SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 95% PROCTOR TEST AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

AS PER PLAN AS PER PLAN AS PER PLAN AS PER PLAN


AS PER PLAN
FOR DIMENSION AND REINFORCMENT REFER TO PILE CAP SCHEDULE FOR DIMENSION AND REINFORCMENT REFER TO PILE CAP SCHEDULE
FOR DIMENSION AND REINFORCMENT REFER TO PILE CAP SCHEDULE

SECTION 1 SECTION 2 SECTION 3


7 1 SCALE 1 : 25
2 SCALE 1 : 25
3 SCALE 1 : 25

WALL WALL
THICK. AS PER PLAN THICK.

6 FOR REINF. REFER FOR REINF. REFER


TO CORE WALL DETAILS TO CORE WALL DETAILS
FOR REINF. REFER FOR REINF. REFER
TO CORE WALL DETAILS TO CORE WALL DETAILS
FOR REINF. REFER FOR REINF. REFER
TO REINF. PLAN TO REINF. PLAN ADD TOP REINF. 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
FOR REINF. REFER AUTHORITY APPROVAL 0 08.08.2017 NS
AS PER PLAN AS PER PLAN ADD TOP REINF. AS PER PLAN TO REINF. PLAN AS PER PLAN
Purpose of Issue Rev. Date Appoved
FOR REINF. REFER
TO REINF. PLAN AS PER PLAN
Client:

THICK.
SLAB
AS PER PILE CAP SCHEDULE
Ld Ld ADD TOP REINF. ADD TOP REINF.
T16@300 RINGS
AS PER PLAN

5
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
1800

T: +9714 3270000 F: +9714 3270007


E: info@dubairacingclub.com W: www.dubairacingclub.com

50MM PROTECTION 50MM PROTECTION Principal Consultant:


SCREED SCREED
WATER PROOFING AS

AS PER PLAN
WATER PROOFING AS
PER PROJECT SPECT. AS PER PILE CAP PER PROJECT SPECT.
T32 @100mm -6.30 SSL SCHEDULE
Ld Ld
75mm BLINDING 75mm BLINDING abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
COMPACTED FILL www.ae-7.com
COMPACTED FILL Hassanicor Building, 6th Floor, Al Barsha 1
95% PROCTOR TEST 95% PROCTOR TEST
PO Box 54115 Dubai, UAE
WATER PROOFING
AS PER RELATED PILE CAP SCHEDULE

P: +971 4 3997758 F: +971 4 3997759


4 AS PER SPEC.
Sub-Consultant:
PROTECTION BOARD
PROTECTION BOARD
BLOCK WORK 200mm
WATER PROOFING
AS PER SPEC.

50MM HIGH STRENGTH BLOCK WORK 200mm

100
FLOWABLE EPOXY GROUT 50MM HIGH STRENGTH
FLOWABLE EPOXY GROUT
T25@150 RINGS
Project Name:

3 50MM HIGH STRENGTH 50MM PROTECTION DUBAI WATER CANAL


FLOWABLE EPOXY GROUT SCREED
WATER PROOFING AS
SAFA A
PER PROJECT SPECT.
DUBAI-UAE
75mm BLINDING

PILE REINFORCEMENT AS PER THE PILING CONTRACTOR COMPACTED FILL


50MM PROTECTION COMPLYING WITH THE PROJECT SPECIFICATIONS 95% PROCTOR TEST Project Description:
SCREED
WATER PROOFING AS MIXED USE DEVELOPMENT
PER PROJECT SPECT.

75mm BLINDING
(RETAIL & RESIDENTIAL)
COMPACTED FILL
PLOT 02 / 3435336
95% PROCTOR TEST
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
PILE REINFORCMENT AS PER THE PILING CONTRACTOR
COMPLYING WITH THE PROJECT SPECIFICATIONS Drawing Title:
AS PER PLAN AS PER PLAN AS PER PLAN

SECTION 5 FOUNDATION DETAILS - 04


FOR DIMENSION AND REINFORCMENT REFER TO PILE CAP SCHEDULE 5 SCALE 1 : 25

SECTION 4
4 SCALE 1 : 25
Scale Drawn
AA
Checked
MA
Approved
NS
Size

1 1 : 25 A1
08.06.2017 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-02-00-S5104 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

FOR REINF. REFER FOR REINF. REFER


TO CORE WALL DETAILS TO CORE WALL DETAILS

FOR REINF. REFER FOR REINF. REFER


TO REINF. PLAN -4.50 S.S.L -4.50 S.S.L TO REINF. PLAN

WALL
THICK.
500

Ld
Ld

N
10 KEY PLAN

WATER STOP
PROTECTION BOARD AS PER SPEC.
1500

WATER PROOFING FOR REINF. REFER


AS PER SPEC. AS PER PLAN TO REINF. PLAN

AS PER PILE CAP SCHEDULE SHOTCRETE


Ld
T16@300 RINGS
Ld -6.30 S.S.L Ld SECANT PILE WALL
2T32 @100mm Ld

500
(REFER TO SHORING DETAILS)
9

AS PER SCHEDULE
T12@300 RINGS General Notes:
WATER PROOFING
AS PER SPEC. 1. DO NOT SCALE FROM THIS DRAWING.
50MM PROTECTION
SCREED PROTECTION BOARD
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
WATER PROOFING AS NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
PER PROJECT SPECT. BLOCK WORK 200mm
BY THE ENGINEER.
1800

75mm BLINDING 50MM HIGH STRENGTH 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES

100
COMPACTED FILL FLOWABLE EPOXY GROUT SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.
95% PROCTOR TEST
WATER PROOFING
AS PER SPEC. 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
PROTECTION BOARD AND RELEVANT SECTIONS OF THE SPECIFICATION.

BLOCK WORK 200mm 50MM PROTECTION


SCREED
50MM HIGH STRENGTH WATER PROOFING AS
FLOWABLE EPOXY GROUT PER PROJECT SPECT.

75mm BLINDING
COMPACTED FILL
95% PROCTOR TEST

7 50MM PROTECTION PILE REINFORCMENT AS PER


SCREED THE PILING CONTRACTOR
WATER PROOFING AS PILE REINFORCMENT AS PER THE PILING CONTRACTOR COMPLYING WITH THE PROJECT
PER PROJECT SPECT. COMPLYING WITH THE PROJECT SPECIFICATIONS SPECIFICATIONS

75mm BLINDING
COMPACTED FILL
SECTION 1 95% PROCTOR TEST

1 SCALE 1 : 25
AS PER PLAN AS PER PLAN

SECTON 2
2 SCALE 1 : 25
6 AS PER PLAN AS PER PLAN AS PER PLAN AS PER PLAN AS PER PLAN

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


AUTHORITY APPROVAL 0 08.08.2017 NS
Purpose of Issue Rev. Date Appoved
Client:
FOR REINF. REFER
TO REINF. PLAN 4.50 SSL

5
MEYDAN L.L.C

500
P.O. Box 9305, Dubai , UAE.
AS PER PLAN T: +9714 3270000 F: +9714 3270007
Ld
E: info@dubairacingclub.com W: www.dubairacingclub.com

T16@200 Principal Consultant:


T25@150
FOR REINF. REFER FOR REINF. REFER
TO CORE WALL DETAILS AS PER PILE CAP SCHEDULE TO CORE WALL DETAILS

T16@300 RINGS FOR REINF. REFER abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
-4.500 SSL TO REINF. PLAN www.ae-7.com
1300

Hassanicor Building, 6th Floor, Al Barsha 1


PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
500

Ld WATER STOP Sub-Consultant:


Ld AS PER PILE CAP SCHEDULE
AS PER SPEC.
PROTECTION BOARD
Ld T32 @100mm 6.30 SSL
WATER PROOFING
AS PER SPEC.

SHOTCRETE

50MM PROTECTION
AS PER PLAN

SCREED SECANT PILE WALL


(REFER TO SHORING DETAILS) Project Name:
WATER PROOFING AS WATER PROOFING
PER PROJECT SPECT. AS PER SPEC.
3 75mm BLINDING PROTECTION BOARD
DUBAI WATER CANAL
COMPACTED FILL
BLOCK WORK 200mm
SAFA A
1900

95% PROCTOR TEST


DUBAI-UAE
T12@300 RINGS
100

50MM HIGH STRENGTH


FLOWABLE EPOXY GROUT Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
50MM PROTECTION PLOT 02 / 3435336
SCREED
100

2 WATER PROOFING AS BLDG 03(1B+G+4) , BLDG 04(1B+G+4)


PER PROJECT SPECT.

75mm BLINDING Drawing Title:


COMPACTED FILL
PILE REINFORCMENT AS PER THE PILING CONTRACTOR
95% PROCTOR TEST
COMPLYING WITH THE PROJECT SPECIFICATIONS 50MM PROTECTION
SCREED
WATER PROOFING AS
FOUNDATION DETAILS - 05
PER PROJECT SPECT.

75mm BLINDING

SECTION 3
COMPACTED FILL Scale Drawn Checked Approved Size
95% PROCTOR TEST
3 1 : 25
AA MA NS
A1
1 SCALE 1 : 25
SECTION 4 PILE REINFORCMENT AS PER THE PILING CONTRACTOR
08.06.2017 24.08.2017 24.08.2017
AS PER PLAN AS PER PLAN AS PER PLAN
4 SCALE 1 : 25
COMPLYING WITH THE PROJECT SPECIFICATIONS

Drawing Number Rev.

AS PER PLAN AS PER PLAN AS PER PLAN


14011603-02-00-S5105 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

FOR REINF. REFER T20@150


TO REINF. PLAN AS PER PLAN T12@150
FOR REINF. REFER T20@150

SLAB THICK.
TO REINF. PLAN AS PER PLAN T12@150

SLAB THICK.
N
10 FOR REINF. REFER
350 T20@150 KEY PLAN
TO REINF. PLAN AS PER PLAN T12@150
WATER PROOFING AS

SLAB THICK.
PER PROJECT SPECT.
WATER PROOFING AS
75mm BLINDING PER PROJECT SPECT.

75mm BLINDING

WATER PROOFING AS
PER PROJECT SPECT.

75mm BLINDING

9 300

350
350

General Notes:
350
1. DO NOT SCALE FROM THIS DRAWING.
PROTECTION BOARD
T12@150 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
PROTECTION BOARD NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
T12@150 BY THE ENGINEER.
VAR. SSL
WATER PROOFING
AS PER SPEC. 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
WATER PROOFING SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK

300
8 AS PER SPEC. AT SITE.
PROTECTION BOARD
T16@200 SHOTCRETE
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
SHOTCRETE ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
T16@200
T20@150 WATER PROOFING
AND RELEVANT SECTIONS OF THE SPECIFICATION.
T25@150 SECANT PILE WALL T12@150 AS PER SPEC.
(REFER TO SHORING DETAILS)
T20@150 SECANT PILE WALL
(REFER TO SHORING DETAILS) T16@200 SHOTCRETE
T12@200 T20@150
WATER STOP
AS PER SPEC. T12@200
WATER STOP SECANT PILE WALL
FOR REINF. REFER AS PER PILE CAP SCHEDULE AS PER SPEC. (REFER TO SHORING DETAILS)
AS PER PLAN TO REINF. PLAN
7 FOR REINF. REFER AS PER PILE CAP SCHEDULE
AS PER PLAN TO REINF. PLAN
WATER STOP
AS PER RELATED PILE CAP SCHEDULE

AS PER SPEC.
Ld
AS PER RELATED PILE CAP SCHEDULE

FOR REINF. REFER AS PER PILE CAP SCHEDULE


Ld AS PER PLAN TO REINF. PLAN

AS PER RELATED PILE CAP SCHEDULE


Ld
T12@300 RINGS
50MM PROTECTION
SCREED T12@300 RINGS
WATER PROOFING AS 50MM PROTECTION
6 PER PROJECT SPECT. SCREED
WATER PROOFING AS
75mm BLINDING 50MM HIGH STRENGTH PER PROJECT SPECT.
100

FLOWABLE EPOXY GROUT T12@300 RINGS


COMPACTED FILL
75mm BLINDING 50MM HIGH STRENGTH 50MM PROTECTION
100

95% PROCTOR TEST 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


FLOWABLE EPOXY GROUT SCREED
COMPACTED FILL
95% PROCTOR TEST WATER PROOFING AS AUTHORITY APPROVAL 0 08.08.2017 NS
PER PROJECT SPECT.
Purpose of Issue Rev. Date Appoved
75mm BLINDING 50MM HIGH STRENGTH

100
FLOWABLE EPOXY GROUT Client:
COMPACTED FILL
95% PROCTOR TEST

5 PILE REINFORCMENT AS PER THE PILING CONTRACTOR


COMPLYING WITH THE PROJECT SPECIFICATIONS MEYDAN L.L.C
PILE REINFORCMENT AS PER THE PILING CONTRACTOR P.O. Box 9305, Dubai , UAE.
COMPLYING WITH THE PROJECT SPECIFICATIONS T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:
PILE REINFORCMENT AS PER THE PILING CONTRACTOR
COMPLYING WITH THE PROJECT SPECIFICATIONS

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
Sub-Consultant:

Project Name:

3
DUBAI WATER CANAL
SAFA A
DUBAI-UAE

BASEMENT WALL SECTION 1 BASEMENT WALL SECTION 2 BASEMENT WALL SECTION 3


1 SCALE 1 : 25
2 SCALE 1 : 25
3 SCALE 1 : 25
Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
PLOT 02 / 3435336
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
Drawing Title:

FOUNDATION DETAILS - 06

Scale Drawn Checked Approved Size


AA MA NS
1 1 : 25 A1
08.06.2017 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-02-00-S5106 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

AS PER PLAN AS PER SLAB REINF. AS PER PLAN AS PER SLAB REINF. AS PER SLAB REINF.
DUBAI MUNICIPALITY STAMP:
AS PER PLAN

SLAB THICK.

SLAB THICK.

300
11

50
300
T12@150 T12@150
T12@150 50mm TH. FIXABLE FILLER BOARD
T12@150

WATER LEVEL WATER LEVEL WATER LEVEL


WATER LEVEL

N
10 T12@150
KEY PLAN
T12@150 T12@150
T16@150
T16@150 T16@150

350
T12@150
9 T12@150
T12@150
T20@150
T20@150 T20@150
WATER STOPPER
AS PER SPEC. WATER STOPPER
WATER STOPPER
AS PER SPEC.
AS PER SPEC. General Notes:
1. DO NOT SCALE FROM THIS DRAWING.
T12@150 T12@150
50mm TH. FIXABLE FILLER BOARD
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
AS PER PLAN 350 AS PER PLAN 350
BY THE ENGINEER.

350
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
AS PER PLAN SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8

50
AT SITE.

500

500
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT

500
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

50MM PROTECTION 50MM PROTECTION


SCREED SCREED
AS PER AS PER
WATER PROOFING AS FOUNDATION REINF. WATER PROOFING AS FOUNDATION REINF. AS PER
50MM PROTECTION
PER PROJECT SPECT. PER PROJECT SPECT. FOUNDATION REINF.
SCREED
75mm BLINDING 75mm BLINDING WATER PROOFING AS
7 PER PROJECT SPECT.
COMPACTED FILL COMPACTED FILL
95% PROCTOR TEST 95% PROCTOR TEST 75mm BLINDING
COMPACTED FILL
95% PROCTOR TEST
SECTION 1-1 SECTION 2-2
1 SCALE 1 : 25
2 SCALE 1 : 25 SECTION 3-3
3 SCALE 1 : 25

AS PER PLAN AS PER PLAN AS PER PLAN AS PER SLAB REINF. 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
AUTHORITY APPROVAL 0 08.08.2017 NS
Purpose of Issue Rev. Date Appoved
VAR. AS PER RAMP REINF. 350 AS PER RAMP REINF.
VAR. Client:
SLAB THICK.

SLAB THICK.

300
WATER PROOFING AS
WATER PROOFING AS PER PROJECT SPECT.
5 PER PROJECT SPECT.
75mm BLINDING T12 @150 MEYDAN L.L.C
75mm BLINDING 350 T12 @150 P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com
WATER LEVEL WATER LEVEL WATER LEVEL WATER LEVEL Principal Consultant:

T12@150 T12@150 T12@150 abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
50mm TH. FIXABLE FILLER BOARD 50mm TH. FIXABLE FILLER BOARD www.ae-7.com
T16@150 T16@150 T16@150 Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4 PROTECTION BOARD PROTECTION BOARD
T16@200 T16@200 Sub-Consultant:
SHOTCRETE SHOTCRETE
T20@150 T20@150
WATER PROOFING WATER PROOFING
AS PER SPEC. AS PER SPEC.
SECANT PILE WALL SECANT PILE WALL
(REFER TO SHORING DETAILS) (REFER TO SHORING DETAILS)

T20@150
T12@150 T12@150 T12@150
T20@150 T20@150
Project Name:
WATER STOPPER
WATER STOPPER WATER STOPPER AS PER SPEC.

3
AS PER SPEC. AS PER SPEC.
T16 @150 DUBAI WATER CANAL
T16 @150
SAFA A
350
DUBAI-UAE

350
AS PER PLAN 350 350
Project Description:

MIXED USE DEVELOPMENT


500

500

500
(RETAIL & RESIDENTIAL)
PLOT 02 / 3435336
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
Drawing Title:
50MM PROTECTION 50MM PROTECTION 50MM PROTECTION
SCREED SCREED SCREED
AS PER AS PER AS PER
WATER PROOFING AS
PER PROJECT SPECT.
FOUNDATION REINF. WATER PROOFING AS
PER PROJECT SPECT.
FOUNDATION REINF.
WATER PROOFING AS
PER PROJECT SPECT.
FOUNDATION REINF. FOUNDATION DETAILS - 07
75mm BLINDING 75mm BLINDING 75mm BLINDING
COMPACTED FILL COMPACTED FILL COMPACTED FILL
95% PROCTOR TEST 95% PROCTOR TEST 95% PROCTOR TEST
Scale Drawn Checked Approved Size
AA MA NS
1
SECTION 4-4 SECTION 5-5 SECTION 6-6 1 : 25 A1
4 SCALE 1 : 25
5 SCALE 1 : 25
6 SCALE 1 : 25
08.06.2017 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-02-00-S5107 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

350 AS PER PLAN


DUBAI MUNICIPALITY STAMP:
AS PER PLAN 350 AS PER SLAB REINF.

SLAB THICK.
11
AS PER RAMP REINF. VAR. WATER PROOFING AS
PER PROJECT SPECT.

75mm BLINDING

WATER PROOFING AS
PER PROJECT SPECT.

75mm BLINDING

WATER LEVEL

N
10 KEY PLAN
WATER LEVEL
T12@150
50mm TH. FIXABLE FILLER BOARD
2T16 2T16 AS PER PLAN FOR REINF. REFER
T16@150
300 T12@200 TO REINF. PLAN
AS PER PLAN AS PER PLAN
PROTECTION BOARD

MAX. 400
T16@200
SHOTCRETE 50mm TH. FIXABLE FILLER BOARD

300
T20@150 T16 @150 Ld
WATER PROOFING
AS PER SPEC. T20 @150 PROTECTION BOARD Ld
SECANT PILE WALL SHOTCRETE
(REFER TO SHORING DETAILS)
T12 @150 WATER PROOFING
9
T20 @150 AS PER SPEC.
T12@150 SECANT PILE WALL
(REFER TO SHORING DETAILS)
T20@150
WATER STOPPER
AS PER SPEC. General Notes:
1. DO NOT SCALE FROM THIS DRAWING.
50MM PROTECTION
50MM PROTECTION 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
SCREED
SCREED NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
WATER STOPPER WATER PROOFING AS BY THE ENGINEER.
350 AS PER SPEC. WATER PROOFING AS PER PROJECT SPECT.
PER PROJECT SPECT. 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
75mm BLINDING SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 75mm BLINDING AT SITE.
COMPACTED FILL
COMPACTED FILL 95% PROCTOR TEST

500
95% PROCTOR TEST 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

TYPICAL DETAIL FOR MECHANICAL TYPICAL DETAIL FOR DRAIN


4

500
3 SCALE 1 : 25
PIT AT PILE CAPS
SCALE 1 : 25
TRENCH AT PILE CAP
50MM PROTECTION
SCREED
AS PER
WATER PROOFING AS
FOUNDATION REINF.
PER PROJECT SPECT. AS PER
7 FOUNDATION REINF. 50MM PROTECTION
75mm BLINDING
SCREED
COMPACTED FILL
95% PROCTOR TEST SECTION 2-2 WATER PROOFING AS
PER PROJECT SPECT.
SECTION 1-1 2
1 SCALE 1 : 25
SCALE 1 : 25 75mm BLINDING
COMPACTED FILL
95% PROCTOR TEST
500 1650 200 1300 200 1650 500
FOR REINF. REFER FOR REINF. REFER
TO REINF. PLAN AS PER PLAN TO REINF. PLAN

AS PER PLAN

250
2T16 2T16
FOR REINF. REFER FOR REINF. REFER
500
AS PER PLAN

6 TO REINF. PLAN AS PER PLAN TO REINF. PLAN T12@150


T12@150
T12@150 250 50 AS PER PLAN 50 250
1100
T12@150
500

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS

250
AUTHORITY APPROVAL 0 08.08.2017 NS
T16@100
T20@150 T20@150 T20@150 Purpose of Issue Date Appoved

50
50MM PROTECTION 50MM PROTECTION
Rev.
SCREED T20@150 T20@150
SCREED Client:
WATER PROOFING AS WATER PROOFING AS T12@100
WATER PROOFING
PER PROJECT SPECT. PER PROJECT SPECT.
AS PER SPEC.
500

50MM PROTECTION 75mm BLINDING PROTECTION BOARD 75mm BLINDING


SCREED
5 COMPACTED FILL

AS PER PLAN
COMPACTED FILL
WATER PROOFING AS
PER PROJECT SPECT.
FOR REINF. REFER
TO REINF. PLAN
95% PROCTOR TEST BLOCK WORK 200mm
95% PROCTOR TEST MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
75mm BLINDING 50mm TH. FIXABLE FILLER BOARD E: info@dubairacingclub.com W: www.dubairacingclub.com
COMPACTED FILL
95% PROCTOR TEST
Principal Consultant:

TYPICAL DETAIL FOR ESCALATOR PIT


50MM PROTECTION
SCREED

TYPICAL DETAIL FOR DRAIN PIT / TRENCH AT RAFT 500 6 SCALE 1 : 25


WATER PROOFING AS
PER PROJECT SPECT.
5

50
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
SCALE 1 : 25 75mm BLINDING www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1

250
500 2000 500 COMPACTED FILL PO Box 54115 Dubai, UAE
FOR REINF. REFER FOR REINF. REFER 95% PROCTOR TEST P: +971 4 3997758 F: +971 4 3997759
4 TO REINF. PLAN AS PER PLAN TO REINF. PLAN
Sub-Consultant:
WALL TYPICAL DETAIL FOR INTERIOR COLUMN
THICK. 9 SCALE 1 : 25 IN WATER TANKS
500

FOR REINF. REFER


FOR REINF. REFER
TO REINF. PLAN
TO CORE WALL DETAILS
250 50 AS PER PLAN 50 250
AS PER PLAN Project Name:
T16@150 T16@150
50MM PROTECTION T16@150 T16@150 50MM PROTECTION
DUBAI WATER CANAL

250
SCREED SCREED
3 T16@100
WATER PROOFING AS WATER PROOFING AS
SAFA A

50
Ld PER PROJECT SPECT. PER PROJECT SPECT.
75mm BLINDING 75mm BLINDING DUBAI-UAE
T12@100
3000

COMPACTED FILL COMPACTED FILL


95% PROCTOR TEST 95% PROCTOR TEST
Project Description:

AS PER PLAN
MIXED USE DEVELOPMENT
600
(RETAIL & RESIDENTIAL)
50mm TH. FIXABLE FILLER BOARD
PLOT 02 / 3435336
2 WATER PROOFING BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
AS PER SPEC.
PROTECTION BOARD Drawing Title:
WATER PROOFING
600

50
AS PER SPEC.
BLOCK WORK 200mm
T16@150 PROTECTION BOARD
FOUNDATION DETAILS - 08

250
BLOCK WORK 200mm

TYPICAL DETAIL FOR EXTERIOR COLUMN


500

10 SCALE 1 : 25 ATTACHED TO WATER TANKS


Scale Drawn Checked Approved Size
AA MA NS
1 1 : 25 A1
20.07.2017 24.08.2017 24.08.2017

TYPICAL SECTION IN DRAIN PIT IN ELEVATOR RAFT TYPICAL SECTION FOR SUMP PITS Drawing Number Rev.

7 SCALE 1 : 25
8 SCALE 1 : 25
14011603-02-00-S5108 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


FILLER MATERIAL AS PER SPEC.
200 VAR. 200 T10@200 T10@200
300 150
11

150

150
300
STRUCTURAL WALL

T12@150 T12@150
AS PER SITE LEVELS AS PER SITE LEVELS
T10@200 T10@200
50MM PROTECTION 50MM PROTECTION

AS PER ARCH.
MAX. 1500 mm
SELF ADHESIVE SCREED SCREED
MEMBRANE AS PER SPEC. WATER PROOFING WATER PROOFING AS WATER PROOFING AS
200 VAR. 200
AS PER SPEC. PER PROJECT SPECT. PER PROJECT SPECT.
PROTECTION BOARD 75mm BLINDING 75mm BLINDING
SELF ADHESIVE MEMBRANE AS PER SPEC.
T10@150
N
10 BLOCK WORK 200mm AS PER SITE LEVELS
T10@200
T10@150 AS PER SITE LEVELS
COMPACTED FILL
95% PROCTOR TEST
COMPACTED FILL
95% PROCTOR TEST
KEY PLAN

MAX. 400
FOR REINF. REFER FOR REINF. REFER
TO REINF. PLAN TO REINF. PLAN T10@200

S.O.G SLAB 150 UNDER WALK WAYS TYPICAL DETAIL S.O.G SLAB 150 UNDER WALK WAYS
WATER PROOFING
PLANTERS AS PER SPEC. PLANTERS
PROTECTION BOARD 3 SCALE 1 : 25
5 SCALE 1 : 25
300

300
BLOCK WORK 200mm

FILLER MATERIAL AS PER SPEC.


T10@200 T10@200
300 100

200

200
300
9 50MM PROTECTION 50MM PROTECTION
SCREED SCREED STRUCTURAL WALL
WATER PROOFING AS WATER PROOFING AS
PER PROJECT SPECT. PER PROJECT SPECT.

75mm BLINDING 75mm BLINDING


General Notes:
COMPACTED FILL COMPACTED FILL
95% PROCTOR TEST 95% PROCTOR TEST 50MM PROTECTION 50MM PROTECTION
SCREED SCREED 1. DO NOT SCALE FROM THIS DRAWING.
WATER PROOFING AS WATER PROOFING AS 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS

TYPICAL SECTION IN PLANTER - 1 TYPICAL SECTION IN PLANTER - 2


PER PROJECT SPECT. PER PROJECT SPECT. NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED

1 SCALE 1 : 25
2 SCALE 1 : 25
75mm BLINDING 75mm BLINDING
BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


COMPACTED FILL COMPACTED FILL
95% PROCTOR TEST 95% PROCTOR TEST SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


S.O.G SLAB 200 UNDER VEHICLES WAYS TYPICAL DETAIL S.O.G SLAB 200 UNDER VEHICLES WAYS ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS

4 SCALE 1 : 25
6 SCALE 1 : 25
AND RELEVANT SECTIONS OF THE SPECIFICATION.

300 600 300 50


7 250 250

WATER LEVEL WATER LEVEL

T10@200 AS PER SITE LEVELS T10@200 AS PER SITE LEVELS


T12@200 T12@150 50mm TH. FIXABLE FILLER BOARD 50mm TH. FIXABLE FILLER BOARD
WATER STOP AS

UP TO 1400mm
T16@150
UP TO 700mm

FOR REINF. REFER TO PER SPAC. FOR REINF. REFER TO


T16@150
REINFORCEMENT PLAN REINFORCEMENT PLAN
AS PER SITE LEVELS AS PER SITE LEVELS

300

300

50 300
WATER PROOFING WATER PROOFING
6 AS PER SPEC. AS PER SPEC.
400

400

PROTECTION BOARD PROTECTION BOARD

500
BLOCK WORK 200mm BLOCK WORK 200mm

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


AUTHORITY APPROVAL 0 08.08.2017 NS
300 250 300 400 250 400 Purpose of Issue Rev. Date Appoved
AS PER
50MM PROTECTION AS PER 50MM PROTECTION FOUNDATION REINF.
SCREED SCREED
Client:
FOUNDATION REINF.
WATER PROOFING AS WATER PROOFING AS 50MM PROTECTION
PER PROJECT SPECT. PER PROJECT SPECT. SCREED
75mm BLINDING 75mm BLINDING WATER PROOFING AS
5 PER PROJECT SPECT.
COMPACTED FILL COMPACTED FILL
75mm BLINDING
MEYDAN L.L.C
95% PROCTOR TEST 95% PROCTOR TEST P.O. Box 9305, Dubai , UAE.
COMPACTED FILL T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com
95% PROCTOR TEST
SECTION 1 IN RW SECTION 2 IN RW Principal Consultant:
7 SCALE 1 : 25
8 SCALE 1 : 25 TYPICAL DETAIL FOR DRAIN PIT IN DOMESTIC TANK
9 SCALE 1 : 25
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
Sub-Consultant:

200 600 200


200 600 200
INSOLUTION LAYER
INSOLUTION LAYER AS PER SITE LEVELS AS PER SPEC. AS PER SITE LEVELS WATER STOPPER
AS PER SITE LEVELS AS PER SITE LEVELS
AS PER SPEC. AS PER SPEC.
AS PER MECH. DETAILS

AS PER RAFT Project Name:


REINFORCEMENT
T12@150 T12@150
DUBAI WATER CANAL
950

370
3 T12@150
T12@150 300 600
SAFA A
T16@150

SLAB THICK.

250
WATER PROOFING WATER PROOFING T16@150 DUBAI-UAE

300
AS PER SPEC. T12@150 AS PER SPEC. T12@150 T16@150
T16@150

500
PROTECTION BOARD PROTECTION BOARD
200

300

THICK.
Project Description:

SLAB
BLOCK WORK 200mm BLOCK WORK 200mm

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
50MM PROTECTION 50MM PROTECTION 50MM PROTECTION
PLOT 02 / 3435336
50MM PROTECTION
2 SCREED SCREED SCREED SCREED BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
WATER PROOFING AS WATER PROOFING AS WATER PROOFING AS WATER PROOFING AS
PER PROJECT SPECT. PER PROJECT SPECT. PER PROJECT SPECT. PER PROJECT SPECT. T20@150
Drawing Title:
75mm BLINDING 75mm BLINDING 75mm BLINDING 75mm BLINDING
COMPACTED FILL COMPACTED FILL COMPACTED FILL COMPACTED FILL
95% PROCTOR TEST 95% PROCTOR TEST 95% PROCTOR TEST 95% PROCTOR TEST
FOUNDATION DETAILS - 09
TYPICAL DETAIL FOR MECHANICAL MANHOLE ON GRADE TYPICAL DETAIL FOR CABLE TRENCH ON GRADE TYPICAL DETAIL FOR DRAIN PIT IN WATER TANK TYPICAL SECTION IN EARTH PIT
10 SCALE 1 : 25
11 SCALE 1 : 25
12 SCALE 1 : 25
13 SCALE 1 : 25
Scale Drawn Checked Approved Size
AA MA NS
1 1 : 25 A1
20.07.2017 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-02-00-S5109 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


SCHEDULE OF PUNCHING SHEAR
3000

11 DETAIL COLUMN DIMENSION NO. OF LINKS NO. OF SPACING DETAIL AS PER PLAN
MARK B (mm) L (mm) N M ROWS (S) TYPE

SLAB THICK
P.S.1 300 1200 3 15 7 75 B

P.S.2 350 1400 3 17 8 75 A

P.S.3 350 1400 3 17 7 75 B


R.C. COLUMN
P.S.4 350 1200 3 15 7 75 A

400 1200 4 15 5 75 A
N
10 P.S.5 KEY PLAN
P.S.6 400 1400 4 17 5 75 A

P.S.7 400 1200 4 15 7 75 A

SLAB

9
02 04

50 N@S 50 50 N@S 50
SLAB
S DROP PANEL
General Notes:
1. DO NOT SCALE FROM THIS DRAWING.

S 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 T10 @S LINKS T10 @S LINKS AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

50

50
01 01 03 03

M@S

M@S
S

S
L

L
3000
7

50

50
Rows x S Rows x S
Rows x S

Rows x S
B 3000
6
B

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


02 04 AUTHORITY APPROVAL 0 08.08.2017 NS
Purpose of Issue Rev. Date Appoved
Client:

5
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com
PUNCHING SHEAR DETAILS TYPE A PUNCHING SHEAR DETAILS TYPE B
A B Principal Consultant:
NTS NTS

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
SLAB RENIF. AS PER SCHEDULE SLAB RENIF. AS PER SCHEDULE SLAB RENIF.
SLAB RENIF. PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4 LINKS LINKS
Sub-Consultant:
THICK

THICK
SLAB

SLAB

THICK
D.P
40 B 40
T10@S T10@S
AS PER D.P REINF. 40 B 40
T10@S T10@S
R.C. COLUMN
Project Name:
R.C. COLUMN
3
DUBAI WATER CANAL
SAFA A
SEC. (01-01) SEC. (03-03)
01 03 DUBAI-UAE
NTS NTS
Project Description:
AS PER SCHEDULE AS PER SCHEDULE MIXED USE DEVELOPMENT
SLAB RENIF. SLAB RENIF. SLAB RENIF. SLAB RENIF.
LINKS (RETAIL & RESIDENTIAL)
LINKS
PLOT 02 / 3435336
THICK

THICK
SLAB

SLAB

THICK
BLDG 03(1B+G+4) , BLDG 04(1B+G+4)

D.P
2
40 L 40
T10@S T10@S Drawing Title:
AS PER D.P REINF. 40 L 40
T10@S T10@S
R.C. COLUMN
SLAB DETAILS - 01
R.C. COLUMN

Scale Drawn Checked Approved Size


AA MA NS
1 N.T.S A1
SEC. (02-02) SEC. (04-04) 08.06.2017 24.08.2017 24.08.2017
02 04
Drawing Number Rev.
NTS NTS
14011603-02-00-S5301 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


200 50 200
MASTIC MATERIAL AS PER SPEC.

DIM
11

T
T FOR REINF. REFER FOR REINF. REFER FOR REINF. REFER
TO REINF. PLAN TO REINF. PLAN TO REINF. PLAN
DIM DIM DIM 3T20 T&B 3T20 T&B 3T20 T&B T10@200 T10@200
-0.400 SSL T10@200 T10@200 -0.400 SSL AS PER PLAN

3T20 T&B

3T20 T&B
T T FOR REINF. REFER

THICK.
SLAB
TO REINF. PLAN
DIM

DIM
T

T
AS PER PLAN
DIM
T 3T20 T&B 3T20 T&B 3T20 T&B

THICK.
SLAB
DETAILS AS PER BEAM SCHEDULE
DIM

N
10
POLYETHYLENE BACKING CORD AS PER SPEC. 50mm EXPANSION JOINT
KEY PLAN

TYPICAL DETAIL FOR REIN. AROUND OPENINGS IN SLABS TYPICAL DETAIL FOR EXPANSION JOINT TYPICAL DETAIL FOR BEAM BETWEEN SLABS WITH DIFFERENT LEVELS
T1 SCALE 1 : 25
T2 SCALE 1 : 25
T3 SCALE 1 : 25

9 200 300 200

AS PER ARCH.
FOR REINF. REFER T10@200 200 300 200
TO REINF. PLAN T10@200

300
T10@200
AS PER ARCH 300 FOR REINF. REFER 2T10 General Notes:

200
-0.200 SSL TO REINF. PLAN T10@200

300
1. DO NOT SCALE FROM THIS DRAWING.
200

-0.400 SSL
THICK.
SLAB

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
THICK.
SLAB

BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 FOR REINF. REFER FOR REINF. REFER AT SITE.
TO REINF. PLAN TO REINF. PLAN
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

TYPICAL DETAIL FOR UPSTAND UNDER CURTAIN WALLS TYPICAL SECTION IN TRENCH IN ARCHITECTURAL FINISH TYPICAL SECTION IN TRENCH EMBEDDED IN STRUCTURAL SLAB
T4 SCALE 1 : 25
T5 SCALE 1 : 25
T6 SCALE 1 : 25

200

AS PER ARCH.
T10@200

MAX 800
T12@200
PT SLAB

M25-G8.8
FILLET WELD
6

THICK
SLAB
PLATE
300 600 300

INSOLUTION LAYER
AS PER SPEC. RING STIRRUPS
FOR REINF. REFER FOR REINF. REFER 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
TO REINF. PLAN TO REINF. PLAN AUTHORITY APPROVAL 0 08.08.2017 NS
STEEL REINFORCEMENT (DOWELS)
AS PER SITE LEVELS AS PER SITE LEVELS 200 TYPICAL DETAIL FOR ROOF PARAPETS Purpose of Issue Rev. Date Appoved
CONCRETE PEDESTAL T10 SCALE 1 : 25 Client:
THICK.

THICK.
SLAB

SLAB

T12@150
M25-G8.8

AS PER ARCH.
T10@200
PLATE
T12@200 EPOXY PAINTED SURFACE
T12@150 T12@200 (RING STIRRUPS)
5 4T12 (DOWELS)
CONCRETE PEDESTAL
ISOLATION/ABSORPTION MATERIAL PADS MEYDAN L.L.C
AS PER MECHANICAL SPECIFICATION

310
P.O. Box 9305, Dubai , UAE.
T12@150 AS PER PLAN T: +9714 3270000 F: +9714 3270007
CONCRETE UPSTAND / PLINTHS WITH E: info@dubairacingclub.com W: www.dubairacingclub.com

VARIES
T12@200
NECESSARY REINFORCEMENT
Principal Consultant:

THICK
SLAB
300

20X30 GROOVE WITH SEALANT 150 200 VARIES 200 150


(ACCORDING TO MECH. EQUIPMENT SELECTION)
600 PT SLAB

150 50 150
PT SLAB
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
+21.400 SSL www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4

THICK
SLAB
TYPICAL DETAIL FOR MECHANICAL MANHOLE ON SLAB TYPICAL DETAIL FOR PEDESTAL TYPICAL DETAIL FOR BMU UPSTAND Sub-Consultant:
T7 SCALE 1 : 25
T8 SCALE 1 : 25
T9 SCALE 1 : 25

TYPICAL DETAIL UNDER MECHANICAL EQUIPMENTS


T11 SCALE 1 : 25

Project Name:

3
DUBAI WATER CANAL
SAFA A
WATER TANKS
LPG TANK DUBAI-UAE
500 US GALLONS CAPACITY

Project Description:

MIXED USE DEVELOPMENT


200 VARIES 200 2000 (RETAIL & RESIDENTIAL)
200 60 300 VARIES 300 60 200
400 600 400 600 400 600 400 600 400 200 200
40 40
PLOT 02 / 3435336

VARIES
(ACCORDING TO MECH. EQUIPMENT SELECTION)
8T12 500 150 700 150 500
2 EPOXY PAINTED SURFACE
+0.60m FROM SSL
BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
T12@200
T12@200 ISOLATION/ABSORPTION MATERIAL PADS
PT SLAB T12@200 T12@200 Drawing Title:
T12@200 AS PER MECHANICAL SPECIFICATION
T12@200
T12@200 T12@200
3T12 3T12 T12@200
600

T12@200 T12@200
600

T12@200 T12@200

+21.400 SSL +21.400 SSL SLAB DETAILS - 02


THICK
SLAB

Scale Drawn Checked Approved Size


PT SLAB
AA MA NS
1 1 : 25 A1
20.07.2017 24.08.2017 24.08.2017

TYPICAL WATERTANK UPSTANDS @ ROOF DETAIL TYPICAL DETAIL FOR LPG TANK RC SUPPORT TYPICAL DETAIL FOR CHILLERS Drawing Number Rev.
T12 T13 T14 14011603-02-00-S5302
SCALE 1 : 25 SCALE 1 : 25 SCALE 1 : 25 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

+6.200 SSL
1400
200 AS PER ARCH. 200
DUBAI MUNICIPALITY STAMP:

AS PER LANDSCAPE DETAILS MAX. 1600 mm


TOP REINF. OF THE BEAM SHOULD BE IMBEDDED IN ALL THE COLUMN LENGTH

AS PER LANDSCAPE DETAILS MAX. 1600 mm


200 AS PER ARCH. 200 WATER INSULATION AS
PER LANDSCAPE DETAILS
11

AS PER LANDSCAPE DETAILS MAX. 1600 mm


AS PER LANDSCAPE DETAILS MAX. 1600 mm
800
WATER INSULATION AS
PER LANDSCAPE DETAILS T10@200 T10@200
T12@200 T12@200
FOR REINF. REFER
PLANTER TO REINF. PLAN
T10@200 T10@200
T12@200 T12@200 -0.550 SSL
-0.600 SSL PLANTER
BEAM AS PER SCHEDULE
FOR REINF. REFER

SLAB THICK
SLAB THICK
TO REINF. PLAN

400
350
-0.600 SSL N
10 KEY PLAN

SLAB THICK
FOR REINF. REFER

350
TO REINF. PLAN
BEAM AS PER SCHEDULE

SECTION 5-5 SECTION 6-6


5 SCALE 1 : 25
6 SCALE 1 : 25

200 AS PER ARCH. 200

AS PER LANDSCAPE DETAILS MAX. 1600 mm

AS PER LANDSCAPE DETAILS MAX. 1600 mm


9 200 AS PER PLAN 200

AS PER LANDSCAPE DETAILS MAX. 1600 mm


AS PER LANDSCAPE DETAILS MAX. 1600 mm
COLUMN AS PER SCHEDULE WATER INSULATION AS
WATER INSULATION AS PER LANDSCAPE DETAILS
PER LANDSCAPE DETAILS
PLANTER
General Notes:

Ld
T10@200 T10@200 T10 @200 T10 @200
T12@200 T12@200 1. DO NOT SCALE FROM THIS DRAWING.
T12 @200 T12 @200
REIN . AT THE EDGE OF THE COLUMN TO BE EXTENDED ALL BEAM LENGTH 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
FOR REINF. REFER BY THE ENGINEER.
TO REINF. PLAN +0.400 SSL
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES

THICKNESS
-0.550 SSL PLANTER SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8

SLAB
AT SITE.

SLAB THICK
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT

400
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.
AS PER SLAB
REINFORCEMENT

SECTION 7-7 SECTION 8-8


7 SCALE 1 : 25
8 SCALE 1 : 25

7
WATER INSULATION AS
FFL AS PER ARCH 200 PER LANDSCAPE DETAILS 200 FFL AS PER ARCH

MAX 400
DOWELS SAME AS COLUMN REINF. T12@200 T12@200
T10@200 T10@200
-0.400 SSL -0.400 SSL

AS PER

THICK

THICK
PLAN REIN.

SLAB

SLAB
-0.200 SSL

Ld

Ld
AS PER RC SLAB RC SLAB
6 PLAN REIN. -0.400 SSL

SLAB
BEAM AS PER SCHEDULE REINF. BEAM AS PER SCHEDULE
-1.500 SSL 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
BEAM AS PER SCHEDULE AUTHORITY APPROVAL 0 08.08.2017 NS
BASEMENT WALL
Purpose of Issue Rev. Date Appoved
Client:
AS PER PLAN

5 SECTION 9-9
9 MEYDAN L.L.C
SECTION 1-1 SCALE 1 : 25 P.O. Box 9305, Dubai , UAE.
1 SCALE 1 : 25 FFL AS PER ARCH 200 WATER INSULATION AS FFL AS PER ARCH
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com
200
PER LANDSCAPE DETAILS Principal Consultant:

MAX 400
T12@200 T12@200

MAX 600
T10@200 T10@200
WATER INSULATION AS -0.400 SSL
FFL AS PER ARCH 200 200 FFL AS PER ARCH SLAB
PER LANDSCAPE DETAILS
REINF. abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
-0.600 SSL www.ae-7.com

THICK
SLAB
MAX 400

T12@200 T12@200 Hassanicor Building, 6th Floor, Al Barsha 1


PO Box 54115 Dubai, UAE

THICK
T10@200 T10@200

SLAB
-0.400 SSL -0.400 SSL P: +971 4 3997758 F: +971 4 3997759
4 SLAB
REINF. RC SLAB Sub-Consultant:
-0.600 SSL
THICK

THICK
SLAB

SLAB

BEAM AS PER SCHEDULE

RC SLAB RC SLAB
SECTION 13-13
BEAM AS PER SCHEDULE BEAM AS PER SCHEDULE 13 SCALE 1 : 25
AS PER PLAN

Project Name:

SECTION 12-12 DUBAI WATER CANAL


3 12 SCALE 1 : 25 200 AS PER ARCH. 200
SAFA A
DUBAI-UAE
SLAB
REINF.
Project Description:
AS PER LANDSCAPE DETAILS MAX. 1600 mm

+0.050 SSL

WATER INSULATION AS
MIXED USE DEVELOPMENT
250

PER LANDSCAPE DETAILS


(RETAIL & RESIDENTIAL)
300

500
AS PER ARCH.

SLAB 5T10 PLOT 02 / 3435336


REINF. T10@200 -0.400 SSL
2 -0.550 SSL
FFL AS PER ARCH FFL AS PER ARCH
BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
T12@200 PLANTER

AS PER LANDSCAPE
Drawing Title:
350

T12@150
400

DETAILS
FOR REINF. REFER T10@200
TO REINF. PLAN
FOR REINF. REFER
TO REINF. PLAN -0.600 SSL
T12@200
SLAB DETAILS - 03
BEAM AS PER SCHEDULE
SLAB THICK

BEAM AS PER SCHEDULE


350

Scale Drawn Checked Approved Size


450 500
AA MA NS
1 1 : 25 A1
20.07.2017 24.08.2017 24.08.2017
SECTION 14-14 SECTION 15-15 SECTION 16-16
14 SCALE 1 : 25
15 SCALE 1 : 25
16 SCALE 1 : 25
Drawing Number Rev.

14011603-02-00-S5303 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

+5.900 SSL AS PER PLAN AS PER PLAN P.T SLAB


AS PER PLAN P.T SLAB P.T SLAB

SLAB THICK
AS PER PLAN

25
P.T SLAB Ld

35
280

525
465
T10@200
T10@200
+5.925 SSL P.T SLAB 5T10
2T10
BEAM AS PER SCHEDULE N
BEAM AS PER SCHEDULE
10 FOR REINF. REFER
BEAM AS PER SCHEDULE KEY PLAN

280
TO REINF. PLAN 400 200 BEAM AS PER SCHEDULE
200 200 BEAM AS PER SCHEDULE
BLOCK WORK

1800
AS PER PLAN BLOCK WORK
BEAM AS PER SCHEDULE BLOCK WORK
+4.700 SSL
+4.700 SSL
+4.700 SSL
350

600
BEAM AS PER SCHEDULE
BEAM AS PER SCHEDULE
BEAM AS PER SCHEDULE
200
200
9 200

SECTION 1-1 SECTION 2-2


1 SCALE 1 : 25
2 SCALE 1 : 25
SECTION 3-3 SECTION 4-4 General Notes:
3 SCALE 1 : 25
4 SCALE 1 : 25
1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.
AS PER 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
140 AS PER PLAN P.T SLAB
+5.925 SSL P.T SLAB +5.925 SSL P.T SLAB +5.865 SSL
AS PER PLAN PLAN +5.865 SSL ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
P.T SLAB AND RELEVANT SECTIONS OF THE SPECIFICATION.

35
25

280
280

P.T SLAB P.T SLAB P.T SLAB P.T SLAB

BEAM AS PER SCHEDULE


BEAM AS PER SCHEDULE BEAM AS PER SCHEDULE BEAM AS PER SCHEDULE
200 BEAM AS PER SCHEDULE
BEAM AS PER SCHEDULE
7 BLOCK WORK
1800

BLOCK WORK BLOCK WORK BLOCK WORK


+4.700 SSL +4.700 SSL +4.700 SSL
+4.700 SSL

AS PER PLAN P.T SLAB


600

600
280
300
BEAM AS PER SCHEDULE BEAM AS PER SCHEDULE BEAM AS PER SCHEDULE
BEAM AS PER SCHEDULE

20
200 200 200 200
200

6 SECTION 5-5 SECTION 6-6 SECTION 7-7 SECTION 8-8 SECTION 9-9
5 SCALE 1 : 25
6 SCALE 1 : 25
7 SCALE 1 : 25
8 SCALE 1 : 25
9 SCALE 1 : 25

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


AUTHORITY APPROVAL 0 08.08.2017 NS
200
200 Purpose of Issue Rev. Date Appoved
Client:

T10@200
T10@200

800
T10@200

800
5 T10@200
MEYDAN L.L.C
+17.400 SSL P.O. Box 9305, Dubai , UAE.
+17.400 SSL T: +9714 3270000 F: +9714 3270007
T10@200 T10@200 E: info@dubairacingclub.com W: www.dubairacingclub.com

SLAB THICK
4T10

SLAB THICK
6T10 Principal Consultant:
AS PER PLAN P.T SLAB

Ld P.T SLAB

975
AS PER PLAN
300

AS PER PLAN P.T SLAB


600

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


525

SLAB THICK

BEAM AS PER SCHEDULE www.ae-7.com


300

BEAM AS PER SCHEDULE Hassanicor Building, 6th Floor, Al Barsha 1


350

PO Box 54115 Dubai, UAE


P: +971 4 3997758 F: +971 4 3997759
50

4 200 200
200 P.T SLAB
Sub-Consultant:

SECTION 10-10 SECTION 11-11 SECTION 12-12 SECTION 13-13 SECTION 14-14
10 SCALE 1 : 25
11 SCALE 1 : 25
12 SCALE 1 : 25
13 SCALE 1 : 25
14 SCALE 1 : 25

Project Name:
T12/200
200
3 +5.900 SSL +5.925 SSL DUBAI WATER CANAL
SAFA A

200
T10@200
T12@200 DUBAI-UAE
800

PT SLAB
P.T SLAB Project Description:
+17.400 SSL +5.925 SSL
AS PER PLAN P.T SLAB BEAM AS PER SCHEDULE MIXED USE DEVELOPMENT
(RETAIL & RESIDENTIAL)
350

Ld BLOCK WORK
300

PLOT 02 / 3435336
765

+4.700 SSL
T10@200 200
2 BEAM AS PER SCHEDULE 6T12 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
T10@200
T10@150 T12@150
625

600

AS PER PLAN P.T SLAB AS PER PLAN P.T SLAB Drawing Title:
T10@150
600

200
200

280

280
300

300
400 500 200
BEAM AS PER SCHEDULE
SLAB DETAILS - 04

20

20
200 300 250

SECTION 15-15 SECTION 16-16 SECTION 17-17


15 16 17 SECTION 18-18 SECTION 19-19 SECTION 20-20
SCALE 1 : 25 SCALE 1 : 25 SCALE 1 : 25 18 SCALE 1 : 25
19 SCALE 1 : 25
20 SCALE 1 : 25
Scale Drawn
AA
Checked
MA
Approved
NS
Size

1 1 : 25 A1
20.07.2017 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-02-00-S5304 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


200

200

11 LESS THAN 200mm


200

AS PER ARCH.
T10@200

MAX 800
T12@200
PT SLAB

AS PER ARCH.
T10@200

AS PER ARCH.

MAX 800
T10@200

MAX 800
T12@200
PT SLAB +17.400 SSL
T12@200
PT SLAB

+17.400 SSL

THICK
SLAB
+17.400 SSL
200

THICK
T10@200

SLAB
THICK
SLAB

200 N
KEY PLAN

AS PER
ARCH.
10 T12@200
200 BEAM AS PER SCHEDULE T12@200
T16@150 +16.675 SSL
T12@200

AS PER
ARCH.
T12@200
T12@200 BEAM AS PER SCHEDULE T12@200
BEAM / WALL AS PER SCHEDULE T16@150 +16.675 SSL
T12@200 T12@200
T16@150 +16.675 SSL
T12@200

600
T12@150

500 1000-1500
T12@150
AS PER PLAN
T12@150 1000-1500
SECTION 3-3
3
9 SECTION 1-1 SECTION 2-2 SCALE 1 : 25
1 SCALE 1 : 25
2 SCALE 1 : 25

General Notes:
1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
200 BY THE ENGINEER.
200
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.
AS PER ARCH.

T12@200

AS PER ARCH.
MAX 800

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


T16@200 T10@200 ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
PT SLAB
T16@200 AND RELEVANT SECTIONS OF THE SPECIFICATION.
PT SLAB
BEAM AS PER SCHEDULE
+17.400 SSL
+17.400 SSL
THICK
SLAB

THICK
SLAB
200 PT SLAB PT SLAB
200

T12@200 +21.400 SSL +21.400 SSL


BEAM AS PER SCHEDULE T12@200

AS PER
ARCH.
7 T16@150 +16.675 SSL T12@200
BEAM AS PER SCHEDULE T12@150

THICK
T12@200

SLAB
T16@150

THICK
+16.675 SSL

SLAB
600

T12@200

T12@150
350 1000-1500
1000-1500 T12@150

SECTION 4-4 SECTION 5-5 SECTION 6-6


4 SCALE 1 : 25
5 SCALE 1 : 25
6 SCALE 1 : 25
6

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


300 AUTHORITY APPROVAL 0 08.08.2017 NS
300
Purpose of Issue Rev. Date Appoved
Client:
FOR REINF. REFER
TO REINF. PLAN FOR REINF. REFER
500

T12@200 TO REINF. PLAN


500

+22.150 SSL T12@200


+22.150 SSL
5
MEYDAN L.L.C
THICK
SLAB

THICK
SLAB
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com
Ld

PT SLAB Principal Consultant:


PT SLAB
200
+21.400 SSL
+21.400 SSL
THICK
SLAB

THICK
SLAB

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


T10@200 www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1

800
T10@200
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4 FOR REINF. REFER BEAM AS PER SCHEDULE
TO WALL REINF. DETAILS BEAM AS PER SCHEDULE +21.400 SSL AS PER PLAN Sub-Consultant:

FOR REINF. REFER

260
260
TO WALL REINF. DETAILS

330
T10@200

70
2T10

70
200 P.T SLAB P.T SLAB 200 200

Project Name:

SECTION 7-7 SECTION 8-8 SECTION 9-9 SECTION 10-10 DUBAI WATER CANAL
3 7 SCALE 1 : 25
8 SCALE 1 : 25
9 SCALE 1 : 25
10 SCALE 1 : 25 SAFA A
DUBAI-UAE
200
Project Description:
T10@200 FOR REINF. REFER
TO REINF. PLAN
MIXED USE DEVELOPMENT
500

T10@200
AS PER PLAN
(RETAIL & RESIDENTIAL)
PLOT 02 / 3435336
200

2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)


VAR.
+21.400 SSL Drawing Title:
260

WALL AS PER SCHEDULE

SLAB DETAILS - 05
70

P.T SLAB

BEAM AS PER SCHEDULE


300
Scale Drawn Checked Approved Size
AA MA NS
1 1 : 25 A1
20.07.2017 24.08.2017 24.08.2017
SECTION 11-11 SECTION 12-12
11 12 Drawing Number Rev.
SCALE 1 : 25 SCALE 1 : 25
14011603-02-00-S5305 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

3.11 3.11
DUBAI MUNICIPALITY STAMP:
UB 203x133x25
3.A 3.A

100
11
3.J 3.J

UB 203x133x25

UB 203x133x25

6 6
S5306 S5306 N
10
UB 203x133x25
KEY PLAN

UC 254x254x167
200mm. THICK C.I.P SLAB

UB 203x133x25
200mm. THICK C.I.P SLAB

+3.645 SSL +4.445 SSL

UB 203x133x25
300mm. THICK P.T SLAB
3.B 3.B
+9.525 SSL

3200
UB 203x133x25

UC 254x254x167
350mm. THICK P.T SLAB +9.525 SSL

UB 203x133x25
9 MESH T12@150 T&B (BW) MESH T12@150 T&B (BW) P.C.
3.K 3.K UC 254x254x167

200
1300 8500
UC 254x254x167

3.14 3.15
+8.630 SSL General Notes:

UB 203x133x25
UB 203x133x25

UB 203x133x25

UB 203x133x25

UB 203x133x25

UB 203x133x25
130mm.STEEL DECK 1. DO NOT SCALE FROM THIS DRAWING.
3.14 3.15
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.
8 8
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
S5306 S5306 SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

3.C 3.C 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT

STEEL CANOPY AT BUILDING 03 LEVEL 02 ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
1175

3
AND RELEVANT SECTIONS OF THE SPECIFICATION.

SCALE 1 : 100
4050

4.14 4.15 4.16 4.17 4.14 4.15 4.16 4.17

ATTIC SLAB BUILDING 03 AT LEVELS +3.645 & +4.445


7 1 SCALE 1 : 100
1885

200
4.G 4.G
UB 203x133x25
4-2CB6

4.14 4.15 4.14 4.15

4.H 4.H UB 203x133x25


5750 5750

4.B 4.B
55

55

250mm. THICK C.I.P SLAB 250mm. THICK C.I.P SLAB UB 203x133x25

UC 254x254x167
4-2B2

UB 203x133x25
6
+3.645 SSL +4.445 SSL

UB 203x133x25

6 6 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


S5306 S5306 AUTHORITY APPROVAL 0 08.08.2017 NS
Purpose of Issue Rev. Date Appoved
MESH T12@150 T&B (BW) MESH T12@150 T&B (BW) UB 203x133x25
Client:
350mm. THICK P.T SLAB
130mm.STEEL DECK +8.630 SSL
+9.525 SSL
4-2B1
5 UB 203x133x25
MEYDAN L.L.C

3400

UB 203x133x25

UB 203x133x25

UB 203x133x25

UB 203x133x25

UB 203x133x25

UC 254x254x167
1950

1950

P.O. Box 9305, Dubai , UAE.


1000 300mm. THICK P.T SLAB +9.525 SSL T: +9714 3270000 F: +9714 3270007
P.C. E: info@dubairacingclub.com W: www.dubairacingclub.com
4.C 4.C UB 203x133x25 Principal Consultant:
100

100
4200 4200 4.J 4.J
UC 254x254x167

160

UB 203x133x25
2625 1700 1300

1500

1500
+8.630 SSL
ATTIC SLAB BUILDING 04 AT LEVELS +3.645 & +4.445 UB 203x133x25

2 SCALE 1 : 100
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
5 1175 5 PO Box 54115 Dubai, UAE
S5306 S5306 P: +971 4 3997758 F: +971 4 3997759
4
Sub-Consultant:

STEEL CANOPY AT BUILDING 04 LEVEL 02


4 SCALE 1 : 100

Ld Ld
Project Name:
6T10 AS PER PLAN 6T10 AS PER PLAN
AS PER PLAN

3
DUBAI WATER CANAL
SAFA A
525

525
T10@200 PT SLAB PT SLAB T10@200 PT SLAB PT SLAB DUBAI-UAE
PT SLAB
BEAM AS PER
150 1T10 150 1T10 AS PER PLAN SCHEDULE Project Description:
STEEL 150 1T10 STEEL
AS PER PLAN AS PER PLAN
125

125
T10@200 DECK BEAM AS PER STEEL AS PER PLAN T10@200 DECK MIXED USE DEVELOPMENT
125

T10@200 DECK BEAM AS PER


SCHEDULE
SCHEDULE (RETAIL & RESIDENTIAL)
PLOT 02 / 3435336
2 STEEL BEAM IN STEEL BEAM IN BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
ELEVATION CONNECTION AS PER ELEVATION
STEEL BEAM IN SUPPLIER DETAIL CONNECTION AS PER STEEL BEAM IN STEEL BEAM IN CONNECTION AS PER
ELEVATION AS PER PLAN STEEL BEAM IN SUPPLIER DETAIL ELEVATION ELEVATION Drawing Title:
AS PER PLAN SUPPLIER DETAIL
ELEVATION
STEEL STEEL
COLUMN IN STEEL COLUMN IN
ELEVATION COLUMN IN
ELEVATION
ELEVATION
SLAB DETAILS - 06

Scale Drawn Checked Approved Size


STEEL CANOPY SECTION 1 STEEL CANOPY SECTION 2 STEEL CANOPY SECTION 3 As AA MA NS
1 5 SCALE 1 : 25
6 SCALE 1 : 25
8 SCALE 1 : 25
indicated 20.07.2017 24.08.2017 24.08.2017
A1

Drawing Number Rev.

14011603-02-00-S5306 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

+21.40SSL
ROOF LEVEL

N
10 KEY PLAN

1
S5501

200
9 +17.40SSL
LOWER ROOF LEVEL
ST3-01 - GROUND LEVEL
2

200
SCALE 1 : 50 02 General Notes:
PE
TY

200
1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
TYPE 03 BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


TY ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
PE

200
02 AND RELEVANT SECTIONS OF THE SPECIFICATION.

TYPE 03
+13.20SSL
LEVEL 03

200
7

200
02
PE
1 TY

200
S5501

ST3-01 - LEVEL 03
6 1 5 SCALE 1 : 50
TY
PE
02

200
S5501
+9.60SSL
LEVEL 02

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS

200
AUTHORITY APPROVAL 0 08.08.2017 NS
Purpose of Issue Rev. Date Appoved
ST3-01 - LEVEL 01

200
02
PE
3 TY Client:

200
SCALE 1 : 50

5 TYPE 03
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

TY
PE
Principal Consultant:
02

200

200
+6.00SSL
LEVEL 01
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759

200
4
02 Sub-Consultant:
PE
TY

200
TYPE 03

1
S5501

Project Name:
TY
PE
02 DUBAI WATER CANAL

200
3
SAFA A
ST3-01 - LEVEL 04
6 SCALE 1 : 50 TYPE 03
DUBAI-UAE

Project Description:

MIXED USE DEVELOPMENT

200
(RETAIL & RESIDENTIAL)

200
01
TY
PE PLOT 02 / 3435336
1
2 S5501 +0.00SSL BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
GROUND LEVEL

Drawing Title:

BUILDING 03
ST3-01 - LEVEL 02 STAIRS DETAILS - 01
4 SCALE 1 : 50
Scale Drawn Checked Approved Size
AA MA NS
1 1 : 50 A1
20.07.2017 24.08.2017 24.08.2017
ST3-01SECTION 1
1 Drawing Number Rev.
SCALE 1 : 50
*NOTE: 14011603-02-00-S5501 0
FOR FLIGHTS REINFORCEMENTS AND TYPES REFER TO DWG S5507
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

3.F
+21.40SSL
ROOF LEVEL DUBAI MUNICIPALITY STAMP:
1 1 1
11 S5502 S5502 S5502

N
10 KEY PLAN

200
+17.40SSL
LOWER ROOF LEVEL

200
02
PE
TY

200
General Notes:

200
1. DO NOT SCALE FROM THIS DRAWING.
TY
PE
02 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

200
+13.20SSL 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
LEVEL 03 SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

200
ST3-02 - BASEMENT 01 LEVEL ST3-02 - GROUND LEVEL ST3-02 - LEVEL 01 PE
02
2 SCALE 1 : 50
3 SCALE 1 : 50
4 SCALE 1 : 50
TY

200

200
7 TY
PE
02

200
+9.60SSL
LEVEL 02

200
02
PE
TY
6

200

200
100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
AUTHORITY APPROVAL 0 08.08.2017 NS
TY
1 1 1 PE
02 Purpose of Issue Rev. Date Appoved
S5502 S5502 S5502
Client:

200
+6.00SSL
LEVEL 01

5
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

200
02 Principal Consultant:
PE
TY

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh

200
www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1

200
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
TY Sub-Consultant:
PE
02

200
Project Name:
02

200
3 TY
PE DUBAI WATER CANAL
SAFA A
+0.00SSL
GROUND LEVEL DUBAI-UAE

200
Project Description:

MIXED USE DEVELOPMENT

200
TY
PE
(RETAIL & RESIDENTIAL)
02
PLOT 02 / 3435336
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)

200
Drawing Title:
ST3-02 - LEVEL 02 ST3-02 - LEVEL 03 ST3-02 - LEVEL 04
5 SCALE 1 : 50
6 SCALE 1 : 50
7 SCALE 1 : 50 BUILDING 03
STAIRS DETAILS - 02

200
01
PE
TY

Scale Drawn Checked Approved Size


AA MA NS
1 -4.50SSL 1 : 50 A1
BASEMENT 01 LEVEL
20.07.2017 24.08.2017 24.08.2017
Drawing Number Rev.
ST3-02 SECTION 1 14011603-02-00-S5502
1 SCALE 1 : 50
*NOTE: 0
FOR FLIGHTS REINFORCEMENTS AND TYPES REFER TO DWG S5507
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

+21.40SSL
ROOF LEVEL DUBAI MUNICIPALITY STAMP:

11

N
10 KEY PLAN

200
+17.40SSL
1 1 LOWER ROOF LEVEL
S5503 S5503

200
02
PE
TY

TYPE 03

200

200
General Notes:
TY
PE
02 1. DO NOT SCALE FROM THIS DRAWING.

200
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.
TYPE 03
+13.20SSL
ST3-03 - LEVEL 02 LEVEL 03 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES

5
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8
ST3-03 - BASEMENT 01 LEVEL AT SITE.

2 SCALE 1 : 50
SCALE 1 : 50
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT

200
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
02
PE AND RELEVANT SECTIONS OF THE SPECIFICATION.
TY

TYPE 03

200

200
7 1 1
S5503 S5503
TY
PE
02

200
+9.60SSL
LEVEL 02

200
02
PE
TY

6
TYPE 03

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS

200

200
AUTHORITY APPROVAL 0 08.08.2017 NS
Purpose of Issue Rev. Date Appoved
TY
PE
02 Client:
ST3-03 - GROUND LEVEL ST3-03 - LEVEL 03

200
+6.00SSL
3 SCALE 1 : 50
6 SCALE 1 : 50
LEVEL 01

5
MEYDAN L.L.C

200
02 P.O. Box 9305, Dubai , UAE.
PE
TY T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:

TYPE 03

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


1 1 www.ae-7.com

200
S5503 S5503 Hassanicor Building, 6th Floor, Al Barsha 1

200
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
TY Sub-Consultant:
PE
02

200
TYPE 03

Project Name:
02
DUBAI WATER CANAL

200
PE
TY
3
+0.00SSL
SAFA A
GROUND LEVEL
DUBAI-UAE

200
ST3-03 - LEVEL 01 ST3-03 - LEVEL 04 Project Description:
4 7 TY MIXED USE DEVELOPMENT

200
SCALE 1 : 50 SCALE 1 : 50 PE
02

200
(RETAIL & RESIDENTIAL)
PLOT 02 / 3435336
TYPE 03
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
Drawing Title:

BUILDING 03

200
02
PE
TY
STAIRS DETAILS - 03

200
TYPE 04
Scale Drawn Checked Approved Size
-4.50SSL AA MA NS
1 BASEMENT 01 LEVEL 1 : 50 A1
20.07.2017 24.08.2017 24.08.2017
Drawing Number Rev.
ST3-03 SECTION 1 14011603-02-00-S5503
1 SCALE 1 : 50
*NOTE: 0
FOR FLIGHTS REINFORCEMENTS AND TYPES REFER TO DWG S5507
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11
+21.40SSL
ROOF LEVEL

1
S5504

N
10 KEY PLAN

200
+17.40SSL
LOWER ROOF LEVEL

TY
PE
9 02

200
General Notes:
TYPE 03
1. DO NOT SCALE FROM THIS DRAWING.

1 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS

ST4-01 - GROUND LEVEL

200
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
S5504

200
2
BY THE ENGINEER.

SCALE 1 : 50 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.
02
PE

200
TY 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

TYPE 03
+13.20SSL
LEVEL 03

TY
PE

200
02

7
TYPE 03

200
S5504

200
ST4-01 - LEVEL 03
5 SCALE 1 : 50 PE
02
TY

200
+9.60SSL
LEVEL 02
6
TY
PE
02

200
100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
AUTHORITY APPROVAL 0 08.08.2017 NS
TYPE 03 Purpose of Issue Rev. Date Appoved
Client:

200
200
5
MEYDAN L.L.C
02
1 PE P.O. Box 9305, Dubai , UAE.
TY T: +9714 3270000 F: +9714 3270007
S5504 E: info@dubairacingclub.com W: www.dubairacingclub.com

200
+6.00SSL
LEVEL 01 Principal Consultant:

ST4-01 - LEVEL 01
3 SCALE 1 : 50
TY abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh

200
PE
02 www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
Sub-Consultant:
TYPE 03

200
200
1
S5504 02 Project Name:
PE

200
TY

3
DUBAI WATER CANAL
ST4-01 - LEVEL 04 TYPE 03 SAFA A
6 SCALE 1 : 50 DUBAI-UAE

TY
PE Project Description:

200
01

MIXED USE DEVELOPMENT


+0.00SSL
GROUND LEVEL (RETAIL & RESIDENTIAL)
PLOT 02 / 3435336
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
Drawing Title:

BUILDING 04
STAIRS DETAILS - 04
ST4-01 - LEVEL 02
4 SCALE 1 : 50
ST4-01 SECTION 1 Scale Drawn Checked Approved Size

1 1 SCALE 1 : 50 1 : 50
AA MA NS
A1
20.07.2017 24.08.2017 24.08.2017
Drawing Number Rev.

*NOTE: 14011603-02-00-S5504 0
FOR FLIGHTS REINFORCEMENTS AND TYPES REFER TO DWG S5507
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

T12@150mm

T12@150mm

200
N
10 T16@150mm KEY PLAN
T16@150mm
T8@150/STEP

200
T8/STEP

T12@150mm
T12@150mm

T16@150mm
9 T12@150mm
1 AS PER
S5505 PLAN REIN.

General Notes:
1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED

ST4-02 - BASEMENT 01 LEVEL BY THE ENGINEER.

4 SCALE 1 : 50
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.
50MM PROTECTION
ST4-02 SECTION 01 SCREED 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT

1 SCALE 1 : 25
WATER PROOFING AS
PER PROJECT SPECT.
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

75mm BLINDING
COMPACTED FILL
95% PROCTOR TEST

7 T12@150mm
200
T12@150mm

-1.212 SSL

200
T8@150/STEP
T8/STEP
T16@150mm

T16@150mm
3 2

200
6 T12@150mm
S5505 S5505
T12@150mm

-2.324 SSL
100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
AUTHORITY APPROVAL 0 08.08.2017 NS
Purpose of Issue Rev. Date Appoved

200
Client:
T16@150mm

T16@150mm

ST4-02 SECTION 02
5
2 SCALE 1 : 25
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:
T12@150mm

T12@150mm 200
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
0.000 SSL www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE

200
P: +971 4 3997758 F: +971 4 3997759
4 T8@150/STEP
Sub-Consultant:
T8/STEP
T16@150mm

T16@150mm

200
ST4-02 - GROUND LEVEL T12@150mm

5 SCALE 1 : 50 T12@150mm

-1.212 SSL Project Name:


200

3
DUBAI WATER CANAL
SAFA A
T16@150mm
DUBAI-UAE
T16@150mm

Project Description:
ST4-02 SECTION 03
3 SCALE 1 : 25
MIXED USE DEVELOPMENT
(RETAIL & RESIDENTIAL)
PLOT 02 / 3435336
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
Drawing Title:

BUILDING 04
STAIRS DETAILS - 05

Scale Drawn Checked Approved Size


As AA MA NS
1 A1
indicated 20.07.2017 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-02-00-S5505 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

+21.40SSL
ROOF LEVEL DUBAI MUNICIPALITY STAMP:

11

N
10 KEY PLAN

200
+17.40SSL
LOWER ROOF LEVEL
1 1
S5506 S5506 02
PE

200
TY

TYPE 03

200
TY
PE
02
General Notes:

200

200
1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
TYPE 03 BY THE ENGINEER.
+13.20SSL
LEVEL 03 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
8 ST4-03 - LEVEL 02 SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK

ST4-03 - BASEMENT 01 LEVEL 5 AT SITE.

2 SCALE 1 : 50 02 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT

200
SCALE 1 : 50 PE
TY ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

TYPE 03

200
TY
PE
02
7 1 1

200
S5506 S5506

+9.60SSL
LEVEL 02

200
02

200
PE
TY

6 TYPE 03

200
100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
TY
PE 0
02 AUTHORITY APPROVAL 08.08.2017 NS
Purpose of Issue Date Appoved

200
Rev.
ST4-03 - GROUND LEVEL ST4-03 - LEVEL 03 Client:
3 SCALE 1 : 50 6 +6.00SSL
LEVEL 01
SCALE 1 : 50

200
5
02
MEYDAN L.L.C

200
PE P.O. Box 9305, Dubai , UAE.
TY T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:

200
TY
PE
02
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh

200
www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
1 1 PO Box 54115 Dubai, UAE
S5506 S5506 P: +971 4 3997758 F: +971 4 3997759
4
Sub-Consultant:

200
02
PE
TY

200
200
TY Project Name:
PE
02
DUBAI WATER CANAL

200
3
+0.00SSL
SAFA A
GROUND LEVEL
DUBAI-UAE

200
ST4-03 - LEVEL 01 ST4-03 - LEVEL 04
Project Description:
4

200
SCALE 1 : 50 7 SCALE 1 : 50 02
MIXED USE DEVELOPMENT
PE
TY (RETAIL & RESIDENTIAL)
PLOT 02 / 3435336
TYPE 03
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)

200
Drawing Title:

BUILDING 04
TY
PE
02

200
STAIRS DETAILS - 06

200
TYPE 04
Scale Drawn Checked Approved Size
-4.50SSL AA MA NS
1 BASEMENT 01 LEVEL 1 : 50 A1
20.07.2017 24.08.2017 24.08.2017
Drawing Number Rev.
ST4-03 SECTION 1 14011603-02-00-S5506
1 SCALE 1 : 50
*NOTE:
FOR FLIGHTS REINFORCEMENTS AND TYPES REFER TO DWG S5507
0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11 SHEAR WALL
SHEAR WALL / BEAM

T12@150mm T12@150mm
T12@150mm

SHEAR WALL / BEAM


T8@150/STEP

200
T8@150

200
T8/STEP
T8-STEP
T16@150mm T8@150
T16@150mm
10 T8-STEP T16@150mm
00 T12@150mm
T16@150mm T12@150mm

200
T16@150mm

200
N
10 T12@150mm AS PER T16@150mm KEY PLAN

200
PLAN REIN.

T16@150mm T12@150mm

TYPE 01 TYPE 02
1 SCALE 1 : 25
2 SCALE 1 : 25
9 50MM PROTECTION
SCREED
WATER PROOFING AS
PER PROJECT SPECT.

75mm BLINDING
COMPACTED FILL
General Notes:
95% PROCTOR TEST
1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.
SHEAR WALL
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 SHEAR WALL / BEAM AT SITE.
T12@150mm
T16@150mm 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
T12@150mm
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
T8@150/STEP AND RELEVANT SECTIONS OF THE SPECIFICATION.

200
SHEAR WALL / BEAM

200
T8@150 T8/STEP
T16@150mm
T8-STEP T16@150mm
T8@150
T12@150mm T12@150mm
T8-STEP T16@150mm

200
T16@150mm
T12@150mm
200

T12@150mm AS PER
T16@150mm PLAN REIN.
200

7
T12@150mm T12@150mm

TYPE 04
4 SCALE 1 : 25 T12@150mm 50MM PROTECTION
T12@150mm SCREED
WATER PROOFING AS
6
TYPE 03 T12@150mm PER PROJECT SPECT.

3 SCALE 1 : 25
T12@150mm 75mm BLINDING
AS PER COMPACTED FILL
T12@150mm -0.400 SSL PLAN REIN. 95% PROCTOR TEST
100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
T12@150mm
AUTHORITY APPROVAL 0 08.08.2017 NS
Purpose of Issue Rev. Date Appoved
Client:

T8@150/STEP
5 T8/STEP BEAM AS PER SCHEDULE
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com
T16@150mm
Principal Consultant:
T12@150mm

250
T16@150mm 0 T16@150mm
121
T16@150mm T12@150mm

-2.205 SSL abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
T16@150mm www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
T12@150mm PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4 0
100
Sub-Consultant:

T8@150/STEP
T8/STEP
250

T12 @ 200
T12 @ 200
Project Name:

3
T12@150mm T16@150mm 300 DUBAI WATER CANAL
T12@150mm T12@150mm
0
SAFA A
105
DUBAI-UAE

Project Description:
AS PER
T12@150
PLAN REIN.
T12@150 -4.500 SSL
MIXED USE DEVELOPMENT
(RETAIL & RESIDENTIAL)
250

Ld
PLOT 02 / 3435336
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
Drawing Title:
T20@150
T20@150
T20@150
WATER PROOFING
AS PER SPEC.
50MM PROTECTION
SCREED
STAIRS DETAILS - 07
PROTECTION BOARD WATER PROOFING AS
PER PROJECT SPECT.
BLOCK WORK 200mm
75mm BLINDING
Scale Drawn Checked Approved Size
COMPACTED FILL AA MA NS
95% PROCTOR TEST 1 : 25 A1
1
20.07.2017 24.08.2017 24.08.2017
SECTION 5-5
5 Drawing Number Rev.
SCALE 1 : 25
14011603-02-00-S5507 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

N
10 KEY PLAN

4.17 4
S5602

4-GRB18

T12@150 (B)
4.B

9 300mm THICK. CIP RAMP

T12@150 (T)
4-GRB18
3.03 3 3.04

4-GRB18
S5602
General Notes:
T20@150 (B) 1. DO NOT SCALE FROM THIS DRAWING.

3-GRCB32

3-GRCB32
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.
300mm THICK. CIP RAMP
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 3.A AT SITE.

3-GRB26 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT

T12@150 (B)
3.03 3.04 3.05
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

3-GRB23
4.C

3-GRB23
3.D

T12@150 (T)
300mm THICK. CIP RAMP T25@150 (B)
7 (FOR WATER TANK SLAB)

T12@150 (T)
300mm THICK. CIP RAMP
1
T)
0(

S5107 OPEINING 800X600 AT


15

LEVEL -2.500 SSL


2@

300mm THICK. CIP RAMP


T1

T1

T12@150 (B)
CO 2@1 3.B
)

800 460
(B

NIT 50
NO (T)
0
15

US
2@
T1

6 4.D
(T)

3.E
0

T1
15

T1
CO 2@1
2@

CO 2@1 NIT 50
B)

NIT 50

T12@150 (T)
NO (T)
T1

NO (B) 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


0(

US US
15

AUTHORITY APPROVAL 0 08.08.2017 NS


2@

2 Purpose of Issue Rev. Date Appoved


T1

T12@150 (B)
S5602
T1 Client:
CO 2@1
NIT 50
NO (B)
US
300mm THICK. CIP RAMP
1
5 1
MEYDAN L.L.C
S5602
S5602 300mm THICK. CIP RAMP
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
3.C E: info@dubairacingclub.com W: www.dubairacingclub.com

T12@150 (T)
T12@150 (T) Principal Consultant:

4.E
T20@150 (B) abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com

RAMP 1 - BASEMENT 01 LEVEL


Hassanicor Building, 6th Floor, Al Barsha 1
T12@150 (T) PO Box 54115 Dubai, UAE
4 1 SCALE 1 : 100 Sub-Consultant:
P: +971 4 3997758 F: +971 4 3997759

4.F
T12@150 (T)

T12@150 (B)

T20@150 (B)

Project Name:

3
3.D
DUBAI WATER CANAL

T12@150 (B)
T12@150 (T)
SAFA A
DUBAI-UAE

Project Description:
4.G
MIXED USE DEVELOPMENT
(RETAIL & RESIDENTIAL)
PLOT 02 / 3435336
RAMP 1 - GROUND LEVEL BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
2
2 SCALE 1 : 100
4.H

Drawing Title:
RAMP 2 FROM BASEMENT 01 TO GROUND LEVEL
3 SCALE 1 : 100
RAMP DETAILS - 01

Scale Drawn Checked Approved Size


AA MA NS
1 1 : 100 A1
20.07.2017 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-02-00-S5601 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

AS PER SLAB
REINFROCEMENT -0.200 SSL
BEAM AS ER SCHEDULE AS PER SLAB
-0.600 SSL REINFROCEMENT

N
10 KEY PLAN
300 3500 300

300 3500 300


T12 @150 T12 @150 T12 @150
T12 @150

1000

1000
T12 @150 T12 @150 T12 @150 T12 @150
AS PER RAFT

300
REINFROCEMENT T12 @150 T12 @150 T12 @150 T12 @150
VAR.

1000
300
T12 @150 T12 @150

300
VAR.
300
500

300
AS PER RAFT
500

9 -4.500 SSL REINFROCEMENT

50MM PROTECTION

500
SCREED AS PER RAFT
T20@150 WATER PROOFING AS REINFROCEMENT
PER PROJECT SPECT.
75mm BLINDING
General Notes:
COMPACTED FILL 50MM PROTECTION
SCREED 1. DO NOT SCALE FROM THIS DRAWING.
95% PROCTOR TEST
WATER PROOFING AS
RAMP 1 SECTION 1-1
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
PER PROJECT SPECT. NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
1 RAMP 1 SECTION 2-2 75mm BLINDING BY THE ENGINEER.
SCALE 1 : 50
2 SCALE 1 : 50
COMPACTED FILL
95% PROCTOR TEST 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

T12 @150

300
350 350 T12 @150 T20 @150
T12 @150
7
350 T12 @150 T20 @150 50MM PROTECTION
PROTECTION BOARD SCREED
T12 @150 BLOCK WORK 200mm WATER PROOFING WATER PROOFING AS
AS PER SPEC. PER PROJECT SPECT.
T12 @150 T20 @150 75mm BLINDING
COMPACTED FILL
300

95% PROCTOR TEST

BEAM AS PER SCHEDULE


T20 @150 T20 @150
T12 @150 T12 @150 PROTECTION BOARD
WATER PROOFING
AS PER SPEC.
6 SHOTCRETE
T16 @150
T20 @150
WATER STOPPER AS PER RAFT WATER STOPPER
AS PER SPEC. REINFROCEMENT AS PER SPEC. SECANT PILE WALL 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
AS PER RAFT
-4.500 SSL (REFER TO SHORING DETAILS) 0
REINFROCEMENT AUTHORITY APPROVAL 08.08.2017 NS
50mm TH. FIXABLE FILLER BOARD
Purpose of Issue Rev. Date Appoved
Client:

50MM PROTECTION
RAMP 1 SECTION 3-3 SCREED
5
3 SCALE 1 : 50
WATER PROOFING AS
PER PROJECT SPECT. MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
75mm BLINDING T: +9714 3270000 F: +9714 3270007
COMPACTED FILL E: info@dubairacingclub.com W: www.dubairacingclub.com
95% PROCTOR TEST
Principal Consultant:

WATER PROOFING
AS PER SPEC.
PROTECTION BOARD abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com
6490 Hassanicor Building, 6th Floor, Al Barsha 1
AS PER SLAB
T12 @150 T20 @150 PO Box 54115 Dubai, UAE
REINFROCEMENT P: +971 4 3997758 F: +971 4 3997759
4 -0.400 SSL
T12 @150 T20 @150
T12 @150 Sub-Consultant:
T12 @150 T25 @150

BLOCK WORK 200mm

T16 @150
T12 @150 T20 @150
T12 @150 T25 @150
T12 @150 BEAM AS PER SCHEDULE
Project Name:
T12 @150 T20 @150
T20 @150

3 T12 @150
PROTECTION BOARD
DUBAI WATER CANAL
WATER PROOFING
SAFA A
T20 @150 AS PER SPEC.
T12 @150 SHOTCRETE DUBAI-UAE
300

SECANT PILE WALL


(REFER TO SHORING DETAILS)
WATER STOPPER WATER STOPPER
Project Description:
AS PER RAFT AS PER RAFT 50mm TH. FIXABLE FILLER BOARD
REINFROCEMENT REINFROCEMENT AS PER SPEC. AS PER SPEC.
300 -4.500 SSL
MIXED USE DEVELOPMENT
(RETAIL & RESIDENTIAL)
300
500

PLOT 02 / 3435336
500

2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)


50MM PROTECTION
SCREED
Drawing Title:
T20@150 WATER PROOFING AS
PER PROJECT SPECT.

RAMP 2 SECTION 4-4


75mm BLINDING
COMPACTED FILL RAMP DETAILS - 02
4 SCALE 1 : 50
95% PROCTOR TEST

Scale Drawn Checked Approved Size


AA MA NS
1 1 : 50 A1
20.07.2017 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-02-00-S5602 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


4.11 4.12 4.13
11 6
S5107

4.14 4.15 4.16


4.14 4.15 4.16
6 N
10 4.E KEY PLAN
S5107

MESH T16@150 T&B (BW)


3
350mm. THICK C.I.P SLAB
S5107
-4.100 SSL

4.C 4.C

WALL REINFORCEMENT SAME


AS REINFORCEMENT AS PER General Notes:
WALL IN SECTION 3/S5107
1. DO NOT SCALE FROM THIS DRAWING.

4.F 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.
3
S5107 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

WATER TANK 1 BASE LAYOUT


MESH T12@200 T&B (BW)

1 SCALE 1 : 50
350mm. THICK C.I.P SLAB
MESH T12@200 T&B (BW)
-4.100 SSL
300mm. THICK P.T SLAB
6
S5107 -0.600 SSL
7

3 3
S5107 S5107

4.11 4.12 4.13

6
4.D 4.D

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


AUTHORITY APPROVAL 0 08.08.2017 NS
Purpose of Issue Rev. Date Appoved
Client:
4.E

5
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
6 E: info@dubairacingclub.com W: www.dubairacingclub.com
S5107 Principal Consultant:

MESH T12@200 T&B (BW)

300mm. THICK P.T SLAB


3 abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
S5107 -0.600 SSL www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
3 PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4 S5107
Sub-Consultant:
3
S5107

4.F

Project Name:

3
3 DUBAI WATER CANAL
S5107
SAFA A
DUBAI-UAE

Project Description:

MIXED USE DEVELOPMENT


WATER TANK 1 SLAB LAYOUT WATER TANK 2 BASE LAYOUT WATER TANK 2 SLAB LAYOUT
2 SCALE 1 : 50
3 SCALE 1 : 50
4 SCALE 1 : 50
(RETAIL & RESIDENTIAL)
PLOT 02 / 3435336
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
Drawing Title:

WATER TANK DETAILS

Scale Drawn Checked Approved Size


AA MA NS
1 1 : 50 A1
20.07.2017 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-02-00-S5901 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

N
10 KEY PLAN

PILE CAP DIMENSIONS


CAP BOTTOM X- DIRECTION BOTTOM Y- DIRECTION REMARKS
MARK LENGTH
(mm)
WIDTH
(mm)
DEPTH
(mm)
REINFORCMENT REINFORCMENT
PC1 1500 1500 1500 T25@100mm T25@100mm --

PC2 1800 1800 1500 T25@100mm T25@100mm --


9 PC3 1500 1500 1500 --
T25@100mm T25@100mm

PC4 3400 1500 1500 T25@100mm T25@100mm --

PC5 3400 1500 1500 T32@100mm T32@100mm --


General Notes:
PC6 1800 1800 1500 T32@100mm T32@100mm --
1. DO NOT SCALE FROM THIS DRAWING.
PC7 1500 1500 1500 2T32@100mm 2T32@100mm --
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
PC8 2500 1800 1500 T25@100mm T25@100mm -- NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.
PC9 2500 1800 1500 T32@100mm T32@100mm --
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 PC10 2500 1500 1500 T25@100mm T25@100mm -- AT SITE.

PC11 2500 1500 1500 T32@100mm T32@100mm -- 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
PC12 REF. PLAN REF. PLAN 1500 T25@100mm T25@100mm -- AND RELEVANT SECTIONS OF THE SPECIFICATION.

PC13 5500 1500 1500 T25@100mm T25@100mm --

PC14 6500 1800 1500 T25@100mm T25@100mm --

PC15 10000 1800 1500 T32@100mm T32@100mm --

PC16 4150 1500 1500 2T32@100mm 2T32@100mm --

PC17 3400 2200 1500 T32@100mm T32@100mm --


7
PC18 4100 1800 1500 T32@100mm T32@100mm --

PC19 4100 1800 1500 T25@100mm T25@100mm --

PC20 REF. PLAN REF. PLAN 1500 T25@100mm T25@100mm --

PC21 9450 5350 1900 T32@100mm T32@100mm --

PC22 REF. PLAN REF. PLAN 1500 T25@100mm T25@100mm --

PC23 REF. PLAN REF. PLAN 1900 T32@100mm T32@100mm --

PC24 REF. PLAN REF. PLAN 1900 2T32@100mm 2T32@100mm --


6
PC25 REF. PLAN REF. PLAN 1900 2T32@100mm 2T32@100mm --

PC26 6400 13300 1900 2T32@100mm 2T32@100mm --

PC27 REF. PLAN REF. PLAN 1900 T32@100mm + T32@200 T32@100mm + T32@200 -- 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
AUTHORITY APPROVAL 0 08.08.2017 NS
PC28 6600 13300 1900 2T32@100mm 2T32@100mm --
Purpose of Issue Rev. Date Appoved
PC29 1800 1800 1500 T25@100mm T25@100mm --
Client:
PC31 1800 1800 1500 T32@100mm T32@100mm --

5
NOTES: MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
1.FOR TOP REINFORCEMENT SAME AS RAFT/ SLAB REINFORCEMENT REFER TO SHEETS SRT0999,SRT1000,S5101,S5102,S5103. T: +9714 3270000 F: +9714 3270007
2.FOR RAFT AT -6.300 SSL LEVEL REFER TO SECTIONS IN SHEET S5103 TO S5105 E: info@dubairacingclub.com W: www.dubairacingclub.com

3.THE PILE CAP DEPTH SHOWN IN THIS SCHEDULE SHOULD BE TAKEN FROM THE TOP OF PILE, ADDITIONAL 100mm Principal Consultant:
TO BE ADDED AS PER DETAILS IN SHEETS S5104 - S5105.

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
Sub-Consultant:

Project Name:

3
DUBAI WATER CANAL
SAFA A
DUBAI-UAE

Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
PLOT 02 / 3435336
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
Drawing Title:

PILE CAP SCHEDULE

Scale Drawn Checked Approved Size


AA MA NS
1 N.T.S A1
08.06.2017 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-02-00-S6001 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

SCHEDULE OF EXTRA BASEMENT 01 LEVEL SLAB REINFORCEMENT N


10 KEY PLAN
EXTRA TOP REINFORCEMENT EXTRA TOP REINFORCEMENT EXTRA BOTTOM REINFORCEMENT EXTRA BOTTOM REINFORCEMENT
LENGTH LENGTH LENGTH LENGTH
TYPE REINFORCEMENT SHAPE TYPE REINFORCEMENT SHAPE TYPE REINFORCEMENT SHAPE TYPE REINFORCEMENT SHAPE
(mm) (mm) (mm) (mm)

6000 9000 5500 3000


AT1 T25@150 6000 AT28 T20@150 9000 AB1 T12@150 5500 AB24 T25@150 3000

5500 7000 5500 4000


AT2 T25@150 5500 AT29 T25@150 7000 AB2 T16@150 5500 AB25 T20@150 4000

9 5500 7000 5500 3000


AT3 T16@150 5500 AT30 T25@150 7000 AB3 T20@150 5500 AB26 T20@150 3000

5500 8000 5000 4000


AT4 T32@75 5500 AT31 T32@75 8000 AB4 T12@150 5000 AB27 T16@150 4000
General Notes:
4000 7500 5500 4000
AT5 T20@150 4000 AT32 T20@150 7500 AB5 T25@150 5500 AB28 T12@150 4000 1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


3000 8000 8000 8000 NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
AT6 T32@150 3000 AT33 T20@150 8000 AB6 T25@150 8000 AB29 T20@150 8000 BY THE ENGINEER.

10000 7000 4000 8500


3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT7 T32@150 10000 AT34 T32@150 7000 AB7 T25@150 4000 AB30 T20@150 8500 AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


5500 9500 3000 8000 ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AT8 T20@150 5500 AT35 T16@150 9500 AB8 T32@150 3000 AB31 T32@150 8000 AND RELEVANT SECTIONS OF THE SPECIFICATION.

4000 9500 10500 9500


AT9 T16@150 4000 AT36 T20@150 9500 AB9 T20@150 10500 AB32 T32@75 9500

6000 11000 6500 9500


AT10 T16@150 6000 AT37 T32@75 11000 AB10 T32@150 6500 AB33 T20@150 9500

5000 3000 9500 7500


7 AT11 T16@150 5000 AT38 T32@75 3000 AB11 T32@150 9500 AB34 T20@150 7500

5000 12000 9000 7500


AT12 T25@150 5000 AT39 T32@150 12000 AB12 T25@150 9000 AB35 T25@150 7500

7000 12000 3000 6500


AT13 T16@150 7000 AT40 T16@150 12000 AB13 T16@150 3000 AB36 T20@150 6500

3000 9500 12000 7000


AT14 T16@150 3000 AT41 T32@150 9500 AB14 T20@150 12000 AB37 T32@150 7000

3000 8000 12000 12000


AT15 T20@150 3000 AT42 T16@150 8000 AB15 T25@150 12000 AB38 T12@150 12000
6
8000 2500 5000 12000
AT16 T32@150 8000 AT43 T20@150 2500 AB16 T16@150 5000 AB39 T16@150 12000

6000 5000 10000 5000 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
AT17 T25@150 6000 AT44 T20@150 5000 AB17 T16@150 10000 AB40 T32@150 5000 AUTHORITY APPROVAL 0 08.08.2017 NS
8000 5000 Purpose of Issue Rev. Date Appoved
10000 5000
AT18 T32@75 8000 AT45 T20@150 5000 AB18 T20@150 10000 AB41 T25@150 5000 Client:

7500 3000 10000 7000


AT19 T32@150 7500 AT46 T16@150 3000 AB19 T12@150 10000 AB42 T32@75 7000
5 12000 2500 7000 7000 MEYDAN L.L.C
AT20 T32@75 12000 AT47 T20@150 2500 AB20 T25@150 7000 AB43 T20@150 7000 P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
8000 2500 6000 12000
E: info@dubairacingclub.com W: www.dubairacingclub.com

AT21 T25@150 8000 AT48 T32@150 2500 AB21 T25@150 6000 AB44 T32@150 12000 Principal Consultant:

5500 8500 5500 4000


AT22 T32@150 5500 AT49 T32@75 8500 AB22 T32@150 5500 AB45 T32@150 4000
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
8000 3500 3000 4000 www.ae-7.com
AT23 T20@150 8000 AT50 T20@150 3500 AB23 T12@150 3000 AB46 T32@75 4000 Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4 10000 4000
AT24 T16@150 10000 AT51 T32@75 4000
Sub-Consultant:

6500 7000
AT25 T32@150 6500 AT52 T32@75 7000

8000 10000
AT26 T16@150 8000 AT53 T32@75 10000

6000 8500 Project Name:


AT27 T20@150 6000 AT54 T32@75 8500

3
DUBAI WATER CANAL
SAFA A
DUBAI-UAE

Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
PLOT 02 / 3435336
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
Drawing Title:

SLAB REINFORCEMENT &


SCHEDULES - 01

Scale Drawn Checked Approved Size


AA MA NS
1 N.T.S A1
08.06.2017 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-02-00-S6301 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

BUILDING -03: SCHEDULE OF EXTRA GROUND LEVEL SLAB REINFORCEMENT

EXTRA TOP REINFORCEMENT EXTRA BOTTOM REINFORCEMENT BUILDING -04: SCHEDULE OF EXTRA GROUND LEVEL SLAB REINFORCEMENT

TYPE REINFORCEMENT
LENGTH
(mm)
SHAPE TYPE REINFORCEMENT
LENGTH
(mm)
SHAPE EXTRA TOP REINFORCEMENT EXTRA BOTTOM REINFORCEMENT
N
10
4000 6000 LENGTH LENGTH
KEY PLAN
TYPE REINFORCEMENT SHAPE TYPE REINFORCEMENT SHAPE
3AT1 T25@150 4000 3AB1 T12@150 6000 (mm) (mm)

2000 5000
6000 8000 4AT1 T16@150 2000 4AB1 T12@150 5000
3AT2 T25@150 6000 3AB2 T16@150 8000

4000 6000
4000 4000 4AT2 T16@150 4000 4AB2 T12@150 6000
3AT3 T32@150 4000 3AB3 T16@150 4000
2000 6000
6000 3000 4AT3 T25@150 2000 4AB3 T16@150 6000
3AT4 T32@150 6000 3AB4 T12@150 3000

4000 12000
9 4000 10000 4AT4 T25@150 4000 4AB4 T20@150 12000
3AT5 T20@150 4000 3AB5 T16@150 10000

5000 5000
9000 3000 4AT5 T25@150 5000 4AB5 T16@150 5000
3AT6 T32@150 9000 3AB6 T25@150 3000
General Notes:
6000 4000
9000 4000 4AT6 T20@150 6000 4AB6 T25@150 4000 1. DO NOT SCALE FROM THIS DRAWING.
3AT7 T25@150 9000 3AB7 T25@150 4000
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
9000 3000
3000 5000 4AT7 T20@150 9000 4AB7 T25@150 3000
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.
3AT8 T16@150 3000 3AB8 T16@150 5000
3750 5000 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
3000 5000 4AT8 T16@150 3750 4AB8 T25@150 5000
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 3AT9 T20@150 3000 3AB9 T12@150 5000 AT SITE.

2000 7000 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
6000 4000 4AT9 T12@150 2000 4AB9 T20@150 7000
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
3AT10 T20@150 6000 3AB10 T20@150 4000 AND RELEVANT SECTIONS OF THE SPECIFICATION.

4000
5000 4AT10 T12@150 4000
3AT11 T20@150 5000
7500
5000 4AT11 T12@150 7500
3AT12 T25@150 5000
3000
3000 4AT12 T12@150 3000
7 3AT13 T25@150 3000
6500
4000 4AT13 T16@150 6500
3AT14 T16@150 4000

6000 6000
4AT14 T25@150 6000
3AT15 T25@150 6000
4500
9000 4AT15 T32@150 4500
3AT16 T20@150 9000

6000 9000
4AT16 T32@150 9000
3AT17 T16@150 6000
6
1500
3000 4AT17 T20@100 1500
3AT18 T32@150 3000

5000 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


3AT19 T20@150 5000 AUTHORITY APPROVAL 0 08.08.2017 NS
Purpose of Issue Rev. Date Appoved
4000
3AT20 T16@150 4000 Client:

2500
3AT21 T25@150 2500
5
1500 MEYDAN L.L.C
3AT22 T12@150 1500 P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com
2000
3AT23 T12@150 2000
Principal Consultant:

5000
3AT24 T25@150 5000
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
3000 www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
3AT25 T12@150 3000 PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4 5000 Sub-Consultant:
3AT26 T16@150 5000

8500
3AT27 T32@150 8500

11000
3AT28 T32@150 11000

12000 Project Name:


3AT29 T32@150 12000

3 5000
DUBAI WATER CANAL
3AT30 T32@150 5000 SAFA A
1500 DUBAI-UAE
3AT31 T20@100 1500

Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
PLOT 02 / 3435336
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
Drawing Title:

SLAB REINFORCEMENT &


SCHEDULES - 02

Scale Drawn Checked Approved Size


AA MA NS
1 N.T.S A1
08.08.2017 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-02-00-S6302 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


N
11

PLOT LIMIT 3.01


N
10 3.02 3.03 KEY PLAN
9500
2200 3.04
1
9500 3.05 1
3.A 03-SC1000b
7750 3.06 03-SC1000a
8200 3.07
8200 3.08
8200 3.09
8200

8200 3.10
PLOT LIMIT
5650 3.11 3.12
9500
2200 3.13
9 9500
3.B

General Notes:
8200

1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.
3.C
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.
8200

3.D

7
8200

3.E
8200

3.F
100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
AUTHORITY APPROVAL 0 08.08.2017 NS
Purpose of Issue Rev. Date Appoved
8200

Client:
3.G

5
3.H
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
9500

E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:

3.I abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


www.ae-7.com
2150

Hassanicor Building, 6th Floor, Al Barsha 1


PO Box 54115 Dubai, UAE
3.J P: +971 4 3997758 F: +971 4 3997759
4
Sub-Consultant:
9550

Project Name:
3.K
3
DUBAI WATER CANAL
SAFA A
PLOT LIMIT
DUBAI-UAE
PLOT LIMIT
12300 8200 8200 8200 8200 8200 8200 8200 12300 Project Description:

3.14 3.15 3.16 3.17 3.18 3.19 3.20 3.21 3.22 3.23
MIXED USE DEVELOPMENT
(RETAIL & RESIDENTIAL)
PLOT 02 / 3435336
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)

BUILDING 03
Drawing Title:

GROUND LEVEL - COLUMNS &


LEGEND: WALLS SETTING OUT PLAN -
R.C. COLUMN OVERALL
R.C. WALL Scale Drawn Checked Approved Size
AA MA NS
1 PLANTED COLUMN / WALL 1 : 200 A1
26.05.2016 24.08.2017 24.08.2017

GROUND LEVEL - COLUMNS & WALLS SETTING OUT PLAN - OVERALL NOTE: Drawing Number Rev.
1 1. FOR COLUMNS & WALLS SCHEDULES REFER TO DWG NO. 03-S6101 TO 03-S6106
14011603-02-03-SC1000
SCALE 1 : 200
2. FOR CORE WALL DETAILS REFER TO DWG NO. 03-S5201 TO 03-S5206
0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

PLOT LIMIT 3.01 DUBAI MUNICIPALITY STAMP:


3.02 N
3.03

11 3.04
1
3.05 03-SC1000b Q
3.A
9500 3.06
1800

125 175
2200
3.07
3W11 250 50 9500
50 250

175

1825 175
7750 3.08
3W12 1100
3W13

300 125
PLOT LIMIT

2875
8200

8200
3C22
8200
N
10 8200 KEY PLAN

3.B

1400 A

175 175
3C19 1200

175 175
1200

175 175
3C20
3C4 1200

175 175
8200

3C15

3.C 3CW1
__
___
_1__ General Notes:
03-S5201
1. DO NOT SCALE FROM THIS DRAWING.

150 150
1200 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
1200

125 225
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
3C21 BY THE ENGINEER.
3C4 1200

125 225
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
8200

3C15 SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK


8 AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

3.D

1400
175 175

3C19 1200
175 175

1200
3C20 175 175
3C4 1200

175 175
8200

7 3C15

3.E

1400
175 175

3C19 1200
175 175

1200
175 175

3C20
6 3C4 1400
175 175
8200

3C1

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


AUTHORITY APPROVAL 0 08.08.2017 NS
Purpose of Issue Rev. Date Appoved
3.F
Client:
1400
175 175

3C19 1200
175 175

125 225 175 175 175 175


8200

5 3C20
MEYDAN L.L.C

100 1400

100 1400
100 1400
3C11 3C12 3C12 P.O. Box 9305, Dubai , UAE.
3.G T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

3CW2
__
___
_2__ Principal Consultant:
03-S5202

3.H abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


www.ae-7.com
1900
9500

125 175

Hassanicor Building, 6th Floor, Al Barsha 1


PO Box 54115 Dubai, UAE
3W9 2100 P: +971 4 3997758 F: +971 4 3997759
125 175

4 175 175 200 200 200 200


250 150 Sub-Consultant:
3W10

1400
1200

1200

1200
3C24 3C8 3C9 3C10
1500

1500

1500

1500
1350 1750 200 2900 150 150
3.I 175 175 225 175
300 600

175 175 175 225


300
2150

150 1850

250 1200
250 1200

250 1200

250 1200

3C18 3W8 3W4 3C4 3C4 3C5

3.J 3C5 Project Name:

3
DUBAI WATER CANAL
SAFA A
DUBAI-UAE
9550

300 3950
Project Description:
275 125 150 150 225 175
175 175 175 175 175 225
MIXED USE DEVELOPMENT
3W1
1600

1600

(RETAIL & RESIDENTIAL)


1400

1400

1400

1400

3W7 3C1 3C1 3C2 3C2


1400

3PC9
PLOT 02 / 3435336
1500

1500

1500

1500

1500

1500
1300

2 3.K
BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
175

4850
800

800

UB 305x305x95 UB 305x305x95
BUILDING 03
Drawing Title:
1200 875
UB 305x305x95

GROUND LEVEL - COLUMNS &


LEGEND:
PLOT LIMIT WALLS SETTING OUT PLAN - PART
R.C. COLUMN
PLOT LIMIT
A
R.C. WALL
12300 8200 8200 8200 8200 Scale Drawn Checked Approved Size
PLANTED COLUMN / WALL AA MA NS
1 3.15 3.16 3.17 3.18 3.19 1 : 150 A1
3.14 26.05.2016 24.08.2017 24.08.2017
NOTE:
Drawing Number Rev.
GROUND LEVEL - COLUMNS & WALLS SETTING OUT PLAN - PART A
1. FOR COLUMNS & WALLS SCHEDULES REFER TO DWG NO. 03-S6101 TO 03-S6106
2. FOR CORE WALL DETAILS REFER TO DWG NO. 03-S5201 TO 03-S5206
1 SCALE 1 : 150
14011603-02-03-SC1000a 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


N
11 3.05 1
03-SC1000a
3.06
Q
8200 3.07

8200 3.08

8200 3.09
PLOT LIMIT
3.A 8200 3.10

5650 3.11
3.12
9500
N
10 2200 3.13 KEY PLAN
9500

350 125
1200

8200
250
3550
250 50

500 100
3C23 50 250

175

175
3PC1
1800 B

125 175
2875

2875
3.B 3W11

3W12
3W12
9 250
3550
250

500
3PC1
3PC1

2650
1400 General Notes:

175 175
250
8200

2600
1200

250 250
3C1

200 200
1. DO NOT SCALE FROM THIS DRAWING.
3PC1
3C6 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
1600

150 150
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.
3W6
3.C
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
250
3550 SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 250 AT SITE.

500
3PC1

500
3PC1 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

3575

3750
1400

175 175
8200

150 350
3C1 3PC1 1200 3CW4

175 175
1200

125 175
3C4
3C16 __
___
_2__
03-S5205

3.D
7

1400

175 175
8200

3C1 1200

175 175
1200

175 175
3C4
3C4 1400

175 175
6 3C1
3.E

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


AUTHORITY APPROVAL 0 08.08.2017 NS
Purpose of Issue Rev. Date Appoved
125 225 1400
8200

Client:
3C1 1200

125 225
175 175 175 175 175 175 1200

175 175
1200 350 3C14
100 1400

100 1400

100 1400

3C4 1400

175 175
3C12
1200

5 3C12 3C12 3C13


3.G 3C3 MEYDAN L.L.C
3.F P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:

3CW3
__
___
_2__
9500

03-S5204 abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


8200

www.ae-7.com
200 200 200 200 Hassanicor Building, 6th Floor, Al Barsha 1
250 150 175 175 1200

225 125
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4 1900
1400

1400

3C9
1200

1200

3C4 3C4

125 175
3C9 3C10 Sub-Consultant:
3W5
3.H
1500

1500

1500

1500

3.I 225 175 175 175 200 200 175 225


175 225 200 200
2150

250 1200
250 1200

250 1200
250 1200

250 1200

200 1250
3C5 3C4 3C6 3C6 3C7
3.J 3C5

Project Name:

3
DUBAI WATER CANAL
SAFA A
9550

DUBAI-UAE
225 175 125 225
150 150
175 225 175 175 200 3775 175 175
Project Description:
1900

3W3
1600

3W2
1400

1400

1400

1400

3C2
3C2 3C3 3C3 MIXED USE DEVELOPMENT
1500 500

3PC10 4000 200


(RETAIL & RESIDENTIAL)
1500

1500

1500

1500

1500

1500
100 400

3.K PLOT 02 / 3435336


500 670

3PC10
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
4000 200 3PC10

BUILDING 03
Drawing Title:

GROUND LEVEL - COLUMNS &


PLOT LIMIT
LEGEND: WALLS SETTING OUT PLAN - PART
8200 8200 8200 8200 12300 R.C. COLUMN
B
R.C. WALL Scale Drawn Checked Approved Size
3.18 3.19 3.20 3.21 3.22 3.23
AA MA NS
1 : 150 A1
GROUND LEVEL - COLUMNS & WALLS SETTING OUT PLAN - PART B
1 PLANTED COLUMN / WALL
26.05.2016 24.08.2017 24.08.2017
1 SCALE 1 : 150 NOTE: Drawing Number Rev.
1. FOR COLUMNS & WALLS SCHEDULES REFER TO DWG NO. 03-S6101 TO 03-S6106
2. FOR CORE WALL DETAILS REFER TO DWG NO. 03-S5201 TO 03-S5206
14011603-02-03-SC1000b 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


N
11

PLOT LIMIT 3.01

3.02 3.03
9500
3.04
2200 1
3.A 9500 3.05 1
03-SC1001b
03-SC1001a N
10 7750 3.06
KEY PLAN
8200 3.07
8200 3.08
8200 3.09

8200
3.10
PLOT LIMIT 8200
5650 3.11 3.12
9500
3.13
2200
3.B 9500

9
8200

General Notes:
3.C 1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


8200

SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK


8 AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.
3.D
8200

7
3.E
8200

3.F
6
8200

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


3.G AUTHORITY APPROVAL 0 08.08.2017 NS
Purpose of Issue Rev. Date Appoved
Client:
3.H
9500

5
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

3.I Principal Consultant:


2150

3.J

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
9550

Sub-Consultant:

3.K

Project Name:

3
PLOT LIMIT DUBAI WATER CANAL
PLOT LIMIT
12300 8200 8200 8200 8200 8200 8200 8200 12300 SAFA A
DUBAI-UAE
3.14 3.15 3.16 3.17 3.18 3.19 3.20 3.21 3.22 3.23

Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
PLOT 02 / 3435336
2 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)
Drawing Title:

BUILDING 03
LEVEL 01 - COLUMNS & WALLS
LEGEND: SETTING OUT PLAN - OVERALL
R.C. COLUMN
Scale Drawn Checked Approved Size
R.C. WALL AA MA NS
1 1 : 200 A1
PLANTED COLUMN / WALL 26.05.2016 24.08.2017 24.08.2017
LEVEL 01 - COLUMNS & WALLS SETTING OUT PLAN - OVERALL
1 SCALE 1 : 200
NOTE: Drawing Number Rev.
1. FOR COLUMNS & WALLS SCHEDULES REFER TO DWG NO. 03-S6101 TO 03-S6106
2. FOR CORE WALL DETAILS REFER TO DWG NO. 03-S5201 TO 03-S5206 14011603-02-03-SC1001 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

PLOT LIMIT 3.01 DUBAI MUNICIPALITY STAMP:


3.02
3.03
N
9500
11 3.04
2200
3.A 9500 3.05 1
03-SC1001b Q
3.06
1800 7750

125 175
200 50 3.07
3W11 8200
50 200

175

1825 175
8200
3.08
3W12 1100

300 125
PLOT LIMIT

2875
3W13 8200

8200
3C22

N
10 KEY PLAN
3.B

1400

125 125
A
3C19 1200

125 125
1200

125 125
3C20
3C4 1400

125 125
8200

3C15

3.C
3CW1 __
___
_2__ General Notes:
03-S5201
1. DO NOT SCALE FROM THIS DRAWING.
1200

150 150
1200

125 125
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
3C21 NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
3C4 1400 BY THE ENGINEER.

125 125
8200

3C15 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

3.D

1400
125 125

3C19 1200
125 125

1200

125 125
3C20
3C4 1400

125 125
8200

7 3C15

3.E

1400
125 125

3C19 1200
125 125

1200
125 125

3C20
3C4 125 125 1400
6
8200

3C1

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


AUTHORITY APPROVAL 0 08.08.2017 NS
3.F Purpose of Issue Rev. Date Appoved

1400
Client:
125 125

3C19 1200
125 125

125 125 125 125 125 125


8200

3C20
5
MEYDAN L.L.C

100 1400

100 1400
100 1400
3C11 3C12 3C12
P.O. Box 9305, Dubai , UAE.
3.G T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

__
___
_3__ Principal Consultant:
03-S5202
3CW2

3.H
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
9500

1900 www.ae-7.com
125 125

Hassanicor Building, 6th Floor, Al Barsha 1


3W9 2100 PO Box 54115 Dubai, UAE
125 125

125 125 P: +971 4 3997758 F: +971 4 3997759


4 125 125 125 125 225 125
3W10 Sub-Consultant:

1400
3C8 3C9
1200

1200

1200
3C24 3C10
1500

1500

1500

1500
1350 1950 200 2900

3.I 125125 125 125 125 125 125 175 175 125
300 600

300
2150

250 1200

250 1200
3C4
250 1200

250 1200

3C18 3W8
150 1450

3W4 3C4 3C5 3C5


3.J
Project Name:

3
DUBAI WATER CANAL
SAFA A
DUBAI-UAE
9550

125 175
Project Description:
275 125 125 125
125 125 125 125 175 125
MIXED USE DEVELOPMENT
1600

1600

1400

1400

1400

1400
3W7 3W1 3C1 3C1 3C2 3C2
(RETAIL & RESIDENTIAL)
PLOT 02 / 3435336
1500
175 1500

1500

1500

1500

1500

1200 875
200 50

2 3.K 4850 BLDG 03(1B+G+4) , BLDG 04(1B+G+4)


800

800

UB 305x305x95 300 3003PC7


UB 305x305x95 UB 305x305x95 Drawing Title:

BUILDING 03
PLOT LIMIT LEVEL 01 - COLUMNS & WALLS
LEGEND:
PLOT LIMIT SETTING OUT PLAN - PART A
R.C. COLUMN
12300 8200 8200 8200 8200
R.C. WALL Scale Drawn Checked Approved Size
AA MA NS
1 3.14 3.15 3.16 3.17 3.18 3.19 PLANTED COLUMN / WALL 1 : 150 A1
26.05.2016 24.08.2017 24.08.2017
NOTE:
LEVEL 01 - COLUMNS & WALLS SETTING OUT PLAN - PART A Drawing Number Rev.
1 SCALE 1 : 150
1. FOR COLUMNS & WALLS SCHEDULES REFER TO DWG NO. 03-S6101 TO 03-S6106
2. FOR CORE WALL DETAILS REFER TO DWG NO. 03-S5201 TO 03-S5206 14011603-02-03-SC1001a 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


3.05
1
3.06 03-SC1001a N
11 8200 3.07

8200 3.08
Q
8200 3.09
PLOT LIMIT
8200 3.10
3.A
5650 3.11
3.12
9500
2200 3.13
9500
N
KEY PLAN

8200
10

300 125
1200
200 50
3C23 50 200

175

175
1800

125 175
2875

2875
3.B 3W12 3W11
3W12
B

9
8200

1400

125 125
3C1 1200

125 125
3C6 General Notes:
1600

125 125
1. DO NOT SCALE FROM THIS DRAWING.
3.C 3W6
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.
8200

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT

125 125
1400 ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS

__
___
_3__
AND RELEVANT SECTIONS OF THE SPECIFICATION.
3CW4
3C1 1200

125 125
1200

125 175
03-S5205
3C4
3C16

3.D

7
8200

1400

125 125
3C1 1200

125 125
1200

125 125
3C4
3C4 1400

125 125
3.E 3C1

6
8200

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


1400

125 125
AUTHORITY APPROVAL 0 08.08.2017 NS
3C1 1200

125 125
125 125 125 125 125 125 1200 Purpose of Issue Rev. Date Appoved

125 125
1200 300 3C14
Client:
100 1400

100 1400

100 1400

3C12 3C12 3C4 1400

125 125
3C12

1200
3C13
3.F 3.G
3C3

5
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.

5300
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com
3CW3
__
___
_3__ Principal Consultant:
8200

9500

03-S5204

125 125 225 125 125 125 125 125 1200

125 125
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
1400
1400

3C9 3C9 3C4 1900


1200
1200

3C10

125 125
3C4 www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
3.H 3W5 PO Box 54115 Dubai, UAE
1500

1500
1500

1500

P: +971 4 3997758 F: +971 4 3997759


4
3.I 125125 125 225
Sub-Consultant:
125 175 175 125 125 125 125 125
2150

250 1200

250 1200

250 1200

250 1200

250 1200

200 1250
3C5 3C5 3C4 3C6 3C6 3C7