Sie sind auf Seite 1von 2

Anchorage and lap lengths according to EC2 based on fyk = 600 Mpa

Bond Reinforcement in tension, bar diameter, f (mm) Rein't in


condition 8 10 12 16 20 25 32 40 comp'n
Concrete class C20/25
Good 330 450 580 830 1100 1420 1800 2450 56f
Anchorage Straight bars only
Poor 460 630 820 1190 1550 2020 2580 3510 80f
length, lbd, in
Good 450 570 690 900 1130 1420 1800 2450 56f
mm Other bars
Poor 640 810 980 1300 1610 2020 2580 3510 80f
50% lapped in Good 450 620 800 1170 1530 1970 2520 3440 79f
Lap length, l0, one location (a6 Poor 640 880 1140 1660 2180 2820 3600 4900 113f
in mm 100% lapped in Good 480 660 860 1240 1640 2120 2700 3680 84f
one location (a6 Poor 620 950 1220 1780 2330 2790 3870 5250 120f
Concrete class C25/30
Good 280 390 500 720 940 1220 1560 2120 48f
Anchorage Straight bars only
Poor 400 540 700 1020 1350 1740 2220 3020 70f
length, lbd, in
Good 390 500 590 780 980 1220 1560 2120 48f
mm Other bars
Poor 560 700 840 1120 1400 1740 2220 3020 70f
50% lapped in Good 390 530 690 1000 1310 1710 2180 2960 68f
Lap length, l0, one location (a6 Poor 560 760 990 1430 1880 2430 3110 4230 97f
in mm 100% lapped in Good 410 570 740 1070 1410 1830 2330 3170 73f
one location (a6 Poor 590 820 1050 1530 2010 2610 3330 4530 104f
Concrete class C28/35
Good 260 360 460 660 880 1130 1440 1960 44f
Anchorage Straight bars only
Poor 360 510 650 950 1240 1610 2070 2800 64f
length, lbd, in
Good 360 460 540 720 900 1130 1440 1960 44f
mm Other bars
Poor 510 650 780 1040 1290 1610 2070 2800 64f
50% lapped in Good 360 500 640 930 1220 1590 2020 2740 62f
Lap length, l0, one location (a6 Poor 510 710 920 1320 1740 2260 2880 3920 90f
in mm 100% lapped in Good 390 530 690 1000 1310 1700 2160 2940 67f
one location (a6 Poor 540 760 980 1420 1860 2420 3090 4170 96f
Concrete class C30/37
Good 260 340 440 640 830 1080 1380 1880 43f
Anchorage Straight bars only
Poor 350 480 630 900 1190 1540 1970 2680 61f
length, lbd, in
Good 350 440 520 700 870 1080 1380 1880 43f
mm Other bars
Poor 500 630 750 990 1240 1540 1970 2680 61f
50% lapped in Good 350 470 620 890 1170 1520 1940 2620 60f
Lap length, l0, one location (a6 Poor 500 680 870 1260 1660 2150 2750 3740 86f
in mm 100% lapped in Good 380 510 650 950 1250 1620 2070 2810 65f
one location (a6 Poor 520 720 940 1360 1780 2310 2960 4010 92f
Concrete class C32/40
Good 240 330 420 620 800 1040 1320 1790 41f
Anchorage Straight bars only
Poor 340 460 600 870 1140 1480 1890 2560 59f
length, lbd, in
Good 330 420 510 660 830 1040 1320 1790 41f
mm Other bars
Poor 470 590 710 950 1180 1480 1890 2560 59f
50% lapped in Good 330 460 590 860 1120 1440 1850 2510 58f
Lap length, l0, one location (a6 Poor 470 650 830 1220 1590 2070 2640 3580 83f
in mm 100% lapped in Good 350 480 630 920 1190 1550 1980 2690 61f
one location (a6 Poor 510 690 890 1300 1710 2210 2820 3840 88f
Concrete class C35/45
Good 230 320 400 580 760 980 1250 1700 38f
Anchorage Straight bars only
Poor 320 440 570 820 1070 1400 1780 2420 55f
length, lbd, in
Good 320 400 470 630 780 980 1250 1700 38f
mm Other bars
Poor 450 570 680 890 1120 1400 1780 2420 55f
50% lapped in Good 320 440 560 810 1050 1360 1740 2370 54f
Lap length, l0, one location (a6 Poor 450 620 780 1140 1500 1950 2490 3380 78f
in mm 100% lapped in Good 340 460 590 860 1130 1460 1860 2540 58f
one location (a6 Poor 470 650 840 1230 1610 2080 2670 3620 83f
Concrete class C40/50
Good 210 280 360 530 690 890 1140 1550 36f
Anchorage Straight bars only
Poor 290 400 520 750 990 1280 1620 2210 50f
length, lbd, in
Good 290 360 440 580 720 890 1140 1550 36f
mm Other bars
Poor 410 520 620 820 1020 1280 1620 2210 50f
Bond Reinforcement in tension, bar diameter, f (mm) Rein't in
condition 8 10 12 16 20 25 32 40 comp'n
50% lapped in Good 290 400 510 740 960 1250 1600 2160 49f
Lap length, l0, one location (a6 Poor 410 560 720 1050 1370 1780 2270 3090 71f
in mm 100% lapped in Good 300 420 540 780 1040 1340 1710 2320 53f
one location (a6 Poor 440 600 770 1120 1470 1910 2440 3320 76f
Concrete class C45/55
Good 200 270 340 480 640 830 1060 1430 32f
Anchorage Straight bars only
Poor 270 380 480 700 920 1180 1500 2040 47f
length, lbd, in
Good 270 340 400 530 660 830 1060 1430 32f
mm Other bars
Poor 380 470 570 760 940 1180 1500 2040 47f
50% lapped in Good 270 360 470 680 890 1160 1480 2010 46f
Lap length, l0, one location (a6 Poor 380 520 660 960 1280 1650 2100 2860 66f
in mm 100% lapped in Good 280 390 510 720 950 1240 1580 2140 49f
one location (a6 Poor 400 560 710 1040 1360 1770 2260 3060 70f
Concrete class C50/60
Good 180 240 320 460 590 770 990 1340 30f
Anchorage Straight bars only
Poor 260 350 450 650 840 1100 1410 1900 43f
length, lbd, in
Good 270 340 400 530 660 830 1060 1430 32f
mm Other bars
Poor 380 470 570 760 940 1180 1500 2040 47f
50% lapped in Good 270 360 470 680 890 1160 1480 2010 46f
Lap length, l0, one location (a6 Poor 380 520 660 960 1280 1650 2100 2860 66f
in mm 100% lapped in Good 280 390 510 720 950 1240 1580 2140 49f
one location (a6 Poor 400 560 710 1040 1360 1770 2260 3060 70f
Notes
1 Cover to all sides and distance between bars 25 mm (i.e. a2 < 1).
2 a1 = a3 = a4 = a5 = 1.0.

Das könnte Ihnen auch gefallen