ALM-26831 802.

1x Authentication Failure
Network Element: Micro BTS3900

Alarm Description

This alarm is reported when 802.1x authentication fails on the transmission port. 802.1x authentication is a network
protection mechanism, preventing unauthorized devices from accessing the local area network (LAN) or wireless local
area network (WLAN).

Alarm Attribute

Alarm ID Alarm Severity Alarm Type Applicable Mode Introduced in


Version...
26831 Major Fault U,L Micro BTS3900:
version earlier than
V100R011C10

Alarm Parameters

Name Meaning
Cabinet No. Cabinet number of the faulty board
Subrack No. Subrack number of the faulty board
Slot No. Slot number of the faulty board
Ethernet Port No. Ethernet Port number

Impact on System

Alarm Severity Alarm Impact


Major When this alarm is reported, the NE can still access the LAN or WLAN if the transport
network does not support 802.1x authentication. If the transport network supports 802.1x
authentication but 802.1x authentication fails, the NE cannot access the LAN or WLAN.

System Actions

None.

Possible Causes

Cause Category Possible Causes


Data configuration The time of the NE is incorrectly set.
Software None
Hardware None
Miscellaneous The Authorization, Authentication and Accounting (AAA) server is faulty.
The certificate of the NE is invalid or not correctly configured.

Prerequisites

None.

Preprocessing

1. Check whether a correlated alarm is reported

Procedure Items to Be Confirmed Duration Impact


(min.)
Procedure Items to Be Confirmed Duration Impact
(min.)

Check for the root alarms on the Check whether root alarms are reported on 1 None
U2000. the U2000:
26266 Time Y=>The root alarms are reported. Clear these
Synchronization Failure root alarms.
N=>The root alarms are not reported.
Continue handling this alarm.

Configuration Handling

None.

Remote Handling

Collapse All

1. Check the base station time

a. Display the Main Topology window

Procedure Items to Be Confirmed Duration Impact


(min.)
Procedure Items to Be Confirmed Duration Impact
(min.)

Note: If the faulty NE has The Main Topology window has been 1 None
been located on the topology, opened and the alarm NE is selected.
skip this step.
On the U2000, right-click the
alarm and choose "Locate in
Topology" from the shortcut
menu.

b. Confirm the connection status of NE

Procedure Items to Be Confirmed Duration Impact


(min.)
Check the icon of the NE that If a red disconnection flag is displayed 1 None
reported this alarm on the in the upper left corner of the NE icon,
Main Topology window. handle the NE disconnection. If there is
no such a flag, continue handling this
alarm.

c. Open the MML Command window

Procedure Items to Be Confirmed Duration Impact


(min.)
On the Main Topology window The MML Command window has been 1 None
of the U2000, right-click the opened successfully.
NE selected in the previous
step and choose MML
Command from the shortcut
menu.

d. Check the NE time

Procedure Items to Be Confirmed Duration Impact


(min.)
On the U2000, run the MML The NE time has been recorded, and 1 None
command DSP TIME to check the related information has been
the current system time on the verified.
NE. And determine whether %%DSP TIME:;%%
the current time is consistent
RETCODE = 0 Operation Succeeded
with the NE time.
Time = X-X-X X:X:X GMT X:X

2. Set the base station time

a. Set the time for the NE

Procedure Items to Be Confirmed Duration Impact


(min.)

Run the MML command The command has been successfully 2 For details
SET TIME to set the NE to executed if a success indication is about the
the current time. included in the command response operation
Input parameters: packets. impact,
An example of the key information in see "Note"
[Date]="Current Date"
the command response packets is as in the help
[Time]="Current Time" information
follows:
of this
%%SET TIME: DATE=2011&08&17,
command.
TIME=13&40&19;%%
RETCODE = 0 Operation
succeeded.

b. Check whether the alarm is cleared


Procedure Items to Be Confirmed Duration Impact
(min.)

Run the MML command LST Check whether this alarm is included in 1 None
ALMAF to query active alarms the command output:
with parameters set as Y=>This alarm is not cleared. Continue
follows: handling this alarm.
[Start Serial No.] = N=>This alarm is cleared. No further
"Equipment Alarm Serial action is required.
Number" in the alarm Pay close attention to the information in
parameters the following example of command
[End Serial No.] = "Equipment output:
Alarm Serial Number" in the %%LST ALMAF: SCSN=1,
alarm parameters ECSN=1;%%
RETCODE = 0 Operation succeeded
No record exists

3. Check the AAA server

a. Troubleshoot the AAA server

Procedure Items to Be Confirmed Duration Impact


(min.)
Ask maintenance personnel to Ensure that the AAA server is working 2 None
troubleshoot the AAA server. properly.

b. Check whether the alarm is cleared

Procedure Items to Be Confirmed Duration Impact


(min.)
Run the MML command LST Check whether this alarm is included in 1 None
ALMAF to query active alarms the command output:
with parameters set as Y=>This alarm is not cleared. Continue
follows: handling this alarm.
[Start Serial No.] = N=>This alarm is cleared. No further
"Equipment Alarm Serial action is required.
Number" in the alarm Pay close attention to the information in
parameters the following example of command
[End Serial No.] = "Equipment output:
Alarm Serial Number" in the %%LST ALMAF: SCSN=1,
alarm parameters ECSN=1;%%
RETCODE = 0 Operation succeeded
No record exists

4. Collect information

a. Collect log information of the micro base station using the one-click method.

Procedure Items to Be Confirmed Duration Impact


(min.)
Procedure Items to Be Confirmed Duration Impact
(min.)

Run the MML command ULD The command output contains the 15 None
FILE to use the one-click following information:The log has been
method to collect log successfully uploaded to the specified
information about the micro directory. This information needs to be
base station. provided to Huawei.
[Function Type] = "ALL" Pay attention to the following
[Source File Type] information in the command output.
="BRDLOG" (This is for reference only.)
Input parameters: %%ULD FILE: FUNCTYPE=ALL,
[Cabinet No.] = "Cabinet SRCF=BRDLOG, CN=0, SRN=0,
No."in the alarm parameters SN=0, DSTF="brdlog.log",
IP="10.148.36.156", USR="admin",
[Subrack No.] = "Subrack No."
PWD="*****";%%
in the alarm parameters
RETCODE = 0 Operation succeeded.
[Slot No.] = "Slot No." in the
alarm parameters
Other parameters are to be
set based on site conditions.

b. Ask Huawei to replace the base station certificate

Procedure Items to Be Confirmed Duration Impact


(min.)
Ask Huawei to the base 1 None
station certificate.

Onsite Preparation

None.

Onsite Handling

None.

Related Information

None.