Sie sind auf Seite 1von 4

Purging/Pressurization Systems Hazardous Location Purge and Pressurization Systems

Spec-01044

Purge and Pressurization Systems


•  ocal visual alarm indicator and dry contact output for remote
L
alarm
• Typically recommended for enclosures with volume of 60 Ft 3 or
less

Certification Type X Model


• P rovides power disconnect when pressurization is lost or not
attained
• P rovides automatic purge process
• E xternal mount
• L ocal visual alarm indicator and dry contact output for remote
alarm
• Typically recommended for enclosures with volume of 60 Ft 3 or
less
INDUSTRY STANDARDS
Type X Continuous Flow
Ex [px] Ex [p] Provides positive pressure via continuous protective air flow
IECEx SIR.0019X [Gb, Db] through the enclosure. System consists of Control Unit, Calibrated
Europe, ATEX Category 2 GD Outlet Orifice and Relief Valve.
Cert no Sira 14ATEX1045X
USA/Canada NFPA496 Cl I Div 1 Groups A, B, C & D Certification Type Y and Z Models
UL E466718 • F lush (internal) or external mount models
• L ocal visual alarm indicator and dry contact output for remote
Type Y alarm
Ex [py] Ex [p] • Typically recommended for enclosures with volume of 17 Ft 3 or
IECEx SIR.0019X [Gb, Db] less. Larger enclosures can use Continuous Flow models but will
Europe, ATEX Category 2 GD require longer purging times.
Cert no Sira 14ATEX1045X
North America Cl I Div 1 Groups A, B, C & D FEATURES
For protecting Cl I Div 2 equipment •  ll exterior components are 316 stainless steel or corrosion-
A
UL E466718 resistant composite
• Space-saving flush or exterior mounted models available
Type Z • Local visual indicators provide system status
Ex [pz] Ex [p] • Leak compensation models are equipped with rapid purge valve
IECEx SIR.0019X [Gc, Dc] and visual purge status indicator
Europe, ATEX Category 3 GD • All models utilize dry, clean inert gas supply of 60 PSI (4 bar) to
Cert no Sira 14ATEX1045X 115 PSI (8 bar)
North America Cl I Div 2 Groups A, B, C & D • A mbient operating temperature -4F (-20C) to 131F (55C)
UL E466718 • Type X models provide automatic purge cycle and
4PNO/20A/440VAC power contactor with 115 VAC or 230 VAC coil
APPLICATION
Purge and Pressurization is a protection method used with Type FINISH
4, 4X and 12 (IP54 recommended minimum) enclosures. The Brushed 316 Stainless Steel
enclosure is initially purged to remove any internal explosive gases
or dust. Once this is accomplished, the enclosure is pressurized OPTIONS
with a protective air or inert gas supply. This provides a positive Service Parts Kit for both Leak Compensation and Continuous Flow
internal enclosure pressure which keeps any external explosive models
gases or dust from entering the enclosure.
MODIFICATION AND CUSTOMIZATION
The two methods of purge and pressurization offered are Leak Hoffman excels at modifying and customizing products to your
Compensation and Continuous Flow. specifications. Cutouts for mounting purge and pressurization
devices can be easily added to your enclosure. Contact your local
Leak Compensation Hoffman Representative or Distributor for more information.
Maintains positive pressure by compensating for losses. System
consists of Control Unit and Relief Valve. Note:
For all IEC and ATEX applications, the final or complete integrated
Certification Type Y and Z models assembly must be submitted to a notified body for certification.
• F lush (internal) or external mount models
Bulletin: HLP

Purge and Pressurization Systems and Certifications 


Protection Type Division (North American, NFPA 496) Zones (IEC / ATEX)
Y Enclosures placed in Division 1 classification area may contain Division 2 internal components Enclosures placed in Zone 1 classification area may have Zone 2 internal components
Z Enclosures placed in Division 2 classification area may contain general purpose internal components Enclosures placed in Zone 2 classification area may have general purpose internal components
X Enclosures placed in Division 1 classification area may contain general purpose internal components Enclosures placed in Zone 1 classification area may have general purpose internal components

Standard Product  Purge and Pressurization


Catalog Number Operation Type Mounting Type Certification
PLCF1YZ Leak Compensation Flush Mount Y and Z
PLCB1YZ Leak Compensation Exterior Mount Y and Z
PCFF1YZ Continuous Flow Flush Mount Y and Z
PCFB1YZ Continuous Flow Exterior Mount Y and Z
PLCS1X1 Leak Compensation Exterior Mount X (120 VAC)
PLCS1X2 Leak Compensation Exterior Mount X (230 VAC)

1 Hazardous Locations Spec-01044 B SUBJECT TO CHANGE WITHOUT NOTICE nVent.com/HOFFMAN


Purging/Pressurization Systems Hazardous Location Purge and Pressurization Systems

Service Kits  
Catalog Number Description
PLCSKIT Purge and Pressurization Leakage Compensation Service Kit
PCFSKIT Purge and Pressurization Continuous Flow Service Kit

3/&)<=

 

$WPRVSKHULF
 
5HIHUHQFH 
 
3RLQW 
3XUJH
&RQWURO 
 9DOYH 

3XUJLQJ
,QGLFDWRU   
3XUJH$LU   
,QOHW
LQ137 )
&HUWLILFDWLRQ /HDNDJH  
/DEHO &RPSHQVDWLRQ
 
9DOYH  ;

&XWRXW 

3/&%<=
$LU,QOHW
LQ137 )
3XUJLQJ,QGLFDWRU
/HDNDJH&RPSHQVDWLRQ 
9DOYH   ;
 

&HUWLILFDWLRQ 
 ODEHO 

 
 
$ODUP3UHVVXUL]HG,QGLFDWRU ;

3XUJH&RQWURO9DOYH  

 
3XUJH$LU2XWOHW
LQ137 )
&XWRXW


 (QFORVXUH3UHVVXUH
 LQ137 )

3XUJH)ORZ *DVNHW QRWVKRZQ


LQ137 ) DSSUR[PPWKLFN
ILWWHGWRWKLVVXUIDFH



3&))<=


 
,QGLFDWRU  
 
/DEHO  
 ;
(QFORVXUH/RZ3UHVVXUH

$ODUPHG3UHVVXUL]HG
JUHHQ 3XUJLQJ,QGLFDWRU

   


 )ORZ&RQWURO9DOYH   

 
3XUJH$LU,QHUW*DV 
&HUWLILFDWLRQ  
6XSSO\LQ137 ) 
ODEHO

&XWRXW 

nVent.com/HOFFMAN PH 763.422.2211 Spec-01044 B Hazardous Locations 2


Purging/Pressurization Systems Hazardous Location Purge and Pressurization Systems

3&)%<=

,QGLFDWRU/DEHO

&HUWLILFDWLRQ 
/DEHO 

 
(QFORVXUH3XUJLQJ,QGLFDWRU  ;  
/RZ3UHVVXUH$ODUP UHG  
)ORZ&RQWURO 3UHVVXUL]HG JUHHQ
9DOYH
 

 


3XUJH(QFORVXUH  ;

2XWOHWLQ137 ) 

(QFORVXUH3UHVVXUH 
LQ137 ) &XWRXW



3/&6;3/&6;

  ;
 
,QGLFDWRUV 
  


  


  


$LU6XSSO\0D[EDUJ 36, 

'3+L(QFORVXUH3UHVVXUH 
LQ137) 
3XUJH2XWOHWLQ137)   
  
 &DEOH '3/R5/9RU6$8&RQQHFWLRQ 
(QWULHV LQ137)    
LQ137    

+ROHVXLWDEOHIRU*ODQG  
0RULQ137 
'3+L(QFORVXUH3UHVVXUH  
0[ ; LQ137) 

  ;  ;


  


&XWRXW 

3 Hazardous Locations Spec-01044 B SUBJECT TO CHANGE WITHOUT NOTICE nVent.com/HOFFMAN


Purging/Pressurization Systems Hazardous Location Purge and Pressurization Systems

 
 
 
 
 ;



  
 
 





 





 0,1  
 
 


5HOLHI9DOYH &XWRXW




 
 

0[3

3DQHO7KLFNQHVV
>@0LQLPXP 
>@0D[LPXP

Outlet Orifice for Continuous Flow Models

nVent.com/HOFFMAN PH 763.422.2211 Spec-01044 B Hazardous Locations 4

Das könnte Ihnen auch gefallen