Sie sind auf Seite 1von 1

NORTH

20
00
20

00
00

20
20
00

3098
20

00
00 NOTES
2000

20
20
00 SOUTH

00
20 1. ORIGINAL DRAWING SIZE - A3

2000
S/S
00

20
Boring

1000
9956
20
00 2. ALL DIMENSIONS ARE IN MILLIMETERS (MM),
45

00
20

20
00 UNLESS OTHERWISE STATED.
20
00

00
00
0 3. USE WRITTEN DIMENSION ONLY

20
20
00
2681 4500 1000 5000 1000 5000

2000
00
20 4. ASSUME ALL DETAILS ARE EXISTING UNLESS OTHERWISE
00

20
Toilet 20 SPECIFIED.
EL +1000 EL +2500 00

00
900 1 20
00

20

3000
DG GENERALNOTES:
Operator EQUIPMENT 20

2500

4500
3000 00

00
House CONTAINER 20 The contractor shall notify the DESIGN ENGINEERG in advance of any changes

20
00
20 on site that do not confirm to the design specification and requirements in the
1200 00 Detailed Design Drawings.
00

20
30

00
20
00
Any changes on the execution of work and site methology, shall be carried
00

20 out only upon written approval from an responsible engineer.


00
20

20
00
00

No works shall be executed unless all necessary Construction Permits are


20
20

7887
00 obtained and approved by the customer.
20
00

00
20

00
7389 5090 1000 10680 1000 10680 16415 CONSTRUCTION NOTES:

10
10
00

00
500
20

20

992
2990 3100 2490 3100 The contractor shall ensure that all existing underground and
00
20

aboveground services and utilies found within the site perimeter and not

00
Solar Panels

20
4036

4036
indicated in the detail design drawing shall be reported to the proper

1809
00
20

management and protected from any further damages during construction.

00
20
20
00

2V5
20

00
ALL HSE POLICIES and procedures shall be strictly implemented during
2500

4727

2500

20
00

construction.
20

00
20
The site area is shadow-free on the south, east and west sides. The

Solar Panels
00
20

south direction is the most important direction.

00
4036

4036
1809

20
00

2V5
20

TERMS AND CONDITIONS :

00
600

20
1. All Reinforced Concrete must be minimum of M -25
00

1002
20

00
2500

2500
2. All Reinforcement Tensile Steel must be minimum of G-60.

20
00

3. All M.S Steel Work must be Hot Deep Galvinized Steel.


20

00
20
Solar Panels
4. All Plain Concrete must be M - 15
00
20

4036

4036

00
20
REV NO. DESCRIPTION DATE REMARKS

2V5
20

00
00

20
20
00 13295 5090 1000 10680 1000 5090 500 5090 6000 0 SITE LAYOUT PLAN DRAWING 13-05-2019

00
20
00

0
20
20

00
00

00
20
7670

20
00

45
20
00

00
20

20
00
20

00
00
20
20
00
00
20
00
20

20
00
20654

00

20
20

00
20 TITLE
00

00
SITE LAYOUT PLAN DRAWING
20

20
00
20
00

00
COMPANY
20

20
00
MANDALAY YOMA ENERGY
00

20
00
20

20
00 PROJECT
00

20 3 0°
20

00
20 MINIGRID SOLAR PLANT
00

00
20

20
00
20
LATITUDE : LONGITUDE:
00

00
20

DRG. NO.
10
00 DRAWN BY CHECKED BY APPROVED BY

KAUNG HTET ZAW MR.SERGEY MR.SERGEY


1 Pump
House W/C Toilet

DATE DATE DATE


13-05-2019 13-05-2019 13-05-2019

Das könnte Ihnen auch gefallen