Sie sind auf Seite 1von 2

Register Title: Environmental, Health and Safety Risk Assessment for Coring Works Version No.: V0.

Register Ref. No.: HA-RG-RA-007 Page 1/2

Environmental, Health and Safety Risk Assessment

Department: H.S.E Section: Health and Safety Date: 01/10/2016

Assessor: Haiettham Abdel Aziem Reviewer: Haietham Reference Number: HES- RA-007

Initial Risk Actions to be taken Residual Risk Policy / Legal &


Personnel at Risk / Sig. Sig./
S/N Activity Hazard Existing Controls Evaluation RL (procedures, training, Evaluation RL Other
Environmental Impacts / NS NS
S P inspections, drills, etc.) S P Requirements
1.Training and Orientation
AD EHSMS –
Excessive Noise and Operatives or 2.Equipping staff with 1.Full time supervision must be CoP – 3.0
Sig 3 1 3 2 1 2
Dust Supervisor P.P.E (Ear Plugs and available at work area. AD EHSMS –
Safety goggles and CoP – 02
Facemask).
1.Training and Orientation
1.Ensuring defective tools are
properly labeled and AD EHSMS –
2.Equipping staff with
maintained(Report for defects) CoP – 3.1
Ergonomic Operatives P.P.E. Sig 3 1 3 2 1 2
AD EHSMS –
2.Continous monitoring CoP – 02
3.Ensuring staff using the
equipment are qualified.
Working with
Portable AD EHSMS –
1 1.Training and Orientation
Power Tools CoP – 35.0
AD EHSMS –
2.Ensuring staff using the 1.Ensuring defective tools are
CoP – 02
equipment are qualified properly labeled and reported
AD EHSMS –
Electrical Shocks Operatives Sig 3 1 3 for repairs or replacement 2 1 2
CoP – 15.0
3.Ensuring tools are in
AD EHSMS –
good working condition by 2.Equipping staff with P.P.E
CoP – 21.0
constant checking and
calibration.

1.Training and Orientation AD EHSMS –


CoP – 35.0
1.Ensuring defective tools are
Potential Source of Fire 2.Equipping staff with AD EHSMS –
Operatives Sig 3 1 3 properly labeled and reported 2 1 2
/ Burns P.P.E CoP – 02
for repairs or replacement
AD EHSMS –
3.Ensuring staff using the CoP – 21.0

Legend: S – Severity; P – Probability; RL – Risk Level (SxP); Sig – Significant; NS – Non-Significant

Code (alpha-numeric): E – Environmental; OHS – Occupational Health & Safety


Register Title: Environmental, Health and Safety Risk Assessment for Coring Works Version No.: V0.1

Register Ref. No.: HA-RG-RA-007 Page 2/2

Initial Risk Actions to be taken Residual Risk Policy / Legal &


Personnel at Risk / Sig. Sig./
S/N Activity Hazard Existing Controls Evaluation RL (procedures, training, Evaluation RL Other
Environmental Impacts / NS NS
S P inspections, drills, etc.) S P Requirements
equipment are qualified

4.Ensuring tools are in


good working condition by
constant checking and
calibration
1.Training and Orientation AD EHSMS –
CoP – 14.0
2.Equipping staff with AD EHSMS –
Manual
2 Body Pain Operatives P.P.E Sig 3 1 3 1.Traing & Supervision 2 1 2 CoP – 02
Handling
AD EHSMS –
3.Ensuring heavy load to CoP – 21.0
be carried by two staff .
1.Barricade the area prior
to start the coring works

Injury to workers due to 2.Only trained and


experienced operatives 1.Continous monitoring
AD EHSMS –
1.Falling of objects sfter are allowed to perform the
CoP – 02
coring. coring works. 2.Prestart briefing to be
3 Coring works Operatives/Visitors Sig 3 2 6 completed prior to start the 2 1 2
AD EHSMS –
2.Fingers getting 3.Appropriate P.P.E to be work.
CoP – 35
crushed used.
3.Full time supervision.
3.Flying objects 4.Proper barrication and
signage to be provided
under the coring location
with adequate signage.

Approver

Legend: S – Severity; P – Probability; RL – Risk Level (SxP); Sig – Significant; NS – Non-Significant

Code (alpha-numeric): E – Environmental; OHS – Occupational Health & Safety