Providing world-class leak test and

assembly verification solutions to


industries around the globe.
Sentinel C28®
Leak Test • C28DP
Instruments • C28WE
Other Sentinel Test Instruments and CTS Products

Tracermate CS I28 C20WE Blackbelt Benchtop Blackbelt Pro Specialized


The Sentinel TracerMate CS is The Sentinel I28 is the most The Sentinel C20 World The Sentinel Blackbelt is The Sentinel Blackbelt Pro Instrumentation
a precision benchtop or wall advanced multi-function Edition is a low cost, high- designed to medical is our 'next generation' of For those special
mount Tracer Gas, Evacuate test instrument on the performance, pressure industry standards, mulit-port/multi-channel application, CTS offers
and Charge instrument market. The I28 features a decay leak test instrument providing up to 4 test port, instrumentation. It can custom test solutions
designed for maximum standard valve manifold sequential testing, and manage and simultaneously with capabilities exceed-
that integrates easily into
configurable with a broad execute 4 part tests under the ing standard instruments.
performance and minimal design tested with over production lines for many
range of pressure and vacuum control of one Blackbelt Pro Call the CTS Products
space. 40,000,000 cycles. applications. instrument.
tests. Group to discuss your
special testing needs.
CTS Connect ® CTS offers a standard line of pneumatic
connectors, manual connectors, and luer connectors, as well
as custom seals. Our line of connectors and custom seals are
designed for ease of use, longevity, and realibility.

Corporate Office China


Cincinnati Test Systems Cincinnati Test Systems
10100 Progress Way Dongfang Road 3601
Harrison, OH 45030 Harvest Industrial Park No. 7 Building
(513) 367-6699 Room 403
Scan to view our
Fax: (513) 367-5426 Pudong, Shanghai, China 200125
web site
www.cincinnati-test.com +86 +21 58366290
Fax: 96-21-58366290 C28 is a registered trademarks of
Cincinnati Test Systems Inc.
Korea ©2016 Cincinnati Test Systems Inc.
Cincinnati Test Systems Korea Inc. Printed in U.S.A. Rev. 1
104-1110, SK Ventium, #522 Dangjeong-dong
Gunpo-si, Gyunggi-do, 435-776 Korea
+82-070-7501-7743
Visit out website: www.cincinnati-test.com Fax: 82-31-624-4743 Providing world-class leak test and assembly verification solutions to industries around the globe.
Sentinel C28®
Precision Leak Test Instruments
For over 30 years Cincinnati Test Systems has lead the market in the integration of advanced technology and innovative features in
standard leak test instrumentation. The multiple technologies and performance offered in our family of Sentinel instruments stand
unmatched worldwide over a diversity of production environments.

Our latest addition offers the compact C28® instrument with Absolute or Differential Pressure (DP) technology. Designed with a 32
bit processor and 24 bit A/D technology, the C28 series of instruments have become known for accuracy, speed, and repeatability.

Advanced features of the C28

Available Technologies • Superior performance • Less complex • Global friendly • Low maintenance • Compact

Global Friendly Available Test Types


Ŷ Language neutral interface Ŷ Pressure or vacuum decay - ΔP
Ŷ Automatic voltage selection Ŷ Pressure or vacuum decay - ΔP/ ΔT
Ŷ 32 Available part programs Ŷ Pressure or vacuum decay - leak std.
Ŷ Menu selectable language Ŷ Pressure or vacuum occlusion
including English, Spanish, Ŷ Pressure drop
Portugese, Chinese, and Korean Ŷ Pressure decay rate of change - ΔP
Ŷ Differential pressure decay - ΔP
Superior Performance Ŷ Differential pressure decay - leak std.
Ŷ 32-bit processor
Ŷ 24-bit A/D converter Low Maintenance
Ŷ High-resolution test results Ŷ Internal leak standards
Ŷ Pressure resolution to 0.000001 Ŷ Self Test Feature
Ŷ Automatic environmental drift Ŷ 40 million cycle valve manifolds
compensation

Smaller - Compact Design


Less Complex Ŷ Space saving enclosure,
Ŷ Auto calibration 9" H x 16.5" W x 7.25" D
Ŷ User friendly menus Ŷ Panel Mount
Ŷ Auto Setup – Pressure Decay Ŷ Fully integrated electronics and
Ŷ Selectable digital inputs/outputs pneumatics
Ŷ Pre-wired I/O for integration

EtherNet/IP ™

Communication
Ŷ Leak test system integration made easy
- RJ45 interface connection
- Reduces installation time
- Simple ‘plug-and-play’ integration to PLC
Ŷ Provides more I/O
- 26 inputs / 25 outputs
Ŷ CTS EtherNet/IP is ODVA Conformance Tested for
flawless operation and verified data exchange
Sentinel C28®
Precision Leak Test Instruments
For over 30 years Cincinnati Test Systems has lead the market in the integration of advanced technology and innovative features in
standard leak test instrumentation. The multiple technologies and performance offered in our family of Sentinel instruments stand
unmatched worldwide over a diversity of production environments.

Our latest addition offers the compact C28® instrument with Absolute or Differential Pressure (DP) technology. Designed with a 32
bit processor and 24 bit A/D technology, the C28 series of instruments have become known for accuracy, speed, and repeatability.

Advanced features of the C28 C28DP C28WE

C28DP Differential Pressure Features C28 Advanced Features


Available Technologies • Superior performance • Less complex • Global friendly • Low maintenance • Compact ■ Auto Calibration ■ Data storage to 12,000 test resultss
- Internally mounted NIST leak standard ■ Test pressure accuracy, 0.4% uncertainty full scale
(supplied with calibration certificate)
Global Friendly Available Test Types - Part and test volume automatically accounted for by the
■ Flow and leak auto calibration
■ Language neutral interface ■ Pressure or vacuum decay - ∆P instrument during calibration
- Converts pressure loss to volumetric leak rate - Characterizes the pressurization effects and
■ Automatic voltage selection ■ Pressure or vacuum decay - ∆P/ ∆T
geometric dynamics of the master part along
■ 32 Available part programs ■ Pressure or vacuum decay - leak std. ■ Test Circuit Features
- DP circuit is monitored by an absolute transducer on a with a NIST traceable leak standard to assure
■ Menu selectable language ■ Pressure or vacuum occlusion
accuracy from zero to the specified leak limit.
including English, Spanish, ■ Pressure drop separate 24-bit analog to digital circuit to protect against leaking
valves, preventing potential passing of bad parts. ■ 6 inputs/3 outputs
Portugese, Chinese, and Korean ■ Pressure decay rate of change - ∆P
- These inputs and outputs are independently
■ Differential pressure decay - ∆P - DP sensor is designed utilizing a silicone based strain gage to
reduce inherent drift and accuracy issues found with programmable within each individual part
Superior Performance ■ Differential pressure decay - leak std.
program
capacitive DP sensors
■ 32-bit processor ■ Instrument 'Self Test'
■ 24-bit A/D converter Low Maintenance C28WE Pressure Decay Features ■ Automatic test setup for easy programming
■ High-resolution test results ■ Internal leak standards ■ Auto Calibration ■ Auto program calibation to leak standard
■ Pressure resolution to 0.000001 ■ Self Test Feature - Internally mounted NIST leak standard ■ Part 'quik test' for shortened cycle times
■ Automatic environmental drift ■ 40 million cycle valve manifolds - Part and test volume automatically accounted for by the ■ Prefill cycle for gross leak failures
compensation instrument during calibration ■ RS232 and EtherNet communication ports
- Converts pressure loss to volumetric leak rate ■ EtherNet/IP™ communication
Smaller - Compact Design ■ Test result data transmission with definable fields
Less Complex ■ Space saving enclosure, ■ Standard absolute transducer
■ Auto calibration 9" H x 16.5" W x 7.25" D - Eliminates noise from barometric pressure changes
■ User friendly menus ■ Panel Mount - All references from absolute zero converted to gauge
■ Auto Setup – Pressure Decay ■ Fully integrated electronics and pressure measurement
■ Selectable digital inputs/outputs pneumatics
■ Pre-wired I/O for integration
Other Sentinel Test Instruments

EtherNet/IP ™
C20WE I28®
Communication
■ Leak test system integration made easy
- RJ45 interface connection
- Reduces installation time
- Simple ‘plug-and-play’ integration to PLC
■ Provides more I/O CTS independent and semi-automatic two-station BlackBelt® BlackBelt Pro®
- 26 inputs / 25 outputs C28DP turnkey test system Designed to perform
■ CTS EtherNet/IP is ODVA Conformance Tested for sequential differential pressure leak testing
flawless operation and verified data exchange on two chambers. www.cincinnati-test.com
Providing world-class leak test and
assembly verification solutions to
industries around the globe.

Other Sentinel Test Instruments and CTS Products

Tracermate CS I28 C20WE Blackbelt Benchtop Blackbelt Pro Specialized


The Sentinel TracerMate CS is The Sentinel I28 is the most The Sentinel C20 World The Sentinel Blackbelt is The Sentinel Blackbelt Pro Instrumentation
a precision benchtop or wall advanced multi-function Edition is a low cost, high- designed to medical is our 'next generation' of For those special
mount Tracer Gas, Evacuate test instrument on the performance, pressure industry standards, mulit-port/multi-channel application, CTS offers
and Charge instrument market. The I28 features a decay leak test instrument providing up to 4 test port, instrumentation. It can custom test solutions
designed for maximum standard valve manifold sequential testing, and manage and simultaneously with capabilities exceed-
that integrates easily into
configurable with a broad execute 4 part tests under the ing standard instruments.
performance and minimal design tested with over production lines for many
range of pressure and vacuum control of one Blackbelt Pro Call the CTS Products
space. 40,000,000 cycles. applications. instrument.
tests. Group to discuss your
special testing needs.
CTS Connect ® CTS offers a standard line of pneumatic
connectors, manual connectors, and luer connectors, as well
as custom seals. Our line of connectors and custom seals are
designed for ease of use, longevity, and realibility.

Corporate Office China


Cincinnati Test Systems Cincinnati Test Systems
10100 Progress Way Dongfang Road 3601
Harrison, OH 45030 Harvest Industrial Park No. 7 Building
(513) 367-6699 Room 403
Scan to view our
Fax: (513) 367-5426 Pudong, Shanghai, China 200125
web site
www.cincinnati-test.com +86 +21 58366290
Fax: 96-21-58366290 C28 is a registered trademarks of
Cincinnati Test Systems Inc.
Korea ©2016 Cincinnati Test Systems Inc.
Cincinnati Test Systems Korea Inc. Printed in U.S.A. Rev. 1
104-1110, SK Ventium, #522 Dangjeong-dong
Gunpo-si, Gyunggi-do, 435-776 Korea
+82-070-7501-7743
Visit out website: www.cincinnati-test.com Fax: 82-31-624-4743