Sie sind auf Seite 1von 2

Tibeliusgatan 7 International Domestic

LUNDAHL
TRANSFORMERS
S-761 50 NORRTÄLJE
SWEDEN
Phone
Fax
+46 - 176 13930
+46 - 176 13935
0176-13930
0176-13935

Line Output Transformer LL2745


LL2745 is a line output transformer for tube amplifiers. The transformer is available with different core air gap
for PP or SE drives.
The transformer primaries are wound with a special low capacitance winding technique to achieve best high
frequency performance. The transformer has a special high flux, low distortion audio C-core of our own
production.
The LL2745PP is assembled with a small core air gap to allow for some DC current unbalance.
For the S.E. versions of the LL2745, the core air gap is chosen such that the denoted DC current (18mA for a
LL2745/18mA) generates a no signal core flux density of 0.9 Tesla when used with all primaries in series. This
leaves a flux density swing of 0.7 T for the signal.
Winding schematics, physical dimensions, pin and mounting hole layout (all dimensions in mm)
36
2
A
5 13
10 9 8 7 5 4 3 2 C
3 16
4 x M3
B
Mounting holes
56 4
73
Bottom view 9
B
21 18 16 13 21
8
C
10 18
A
53 61
7

Weight Turns ratio Static resistance, Static resistance, Static resistance,


winding A winding B winding C
0.75 Kg 2.8+2.8 : 1+1+1+1 142  185  630 
Max. current through any primary (“C”) section: 50 mA
Isolation between primary and secondary windings / between windings and core: 4 kV / 2 kV
Type LL2745/PP LL2745/PP LL2745/PP LL2745/18mA
Connection Alt M Alt N Alt O Alt P
PP to Line Out. PP to Line Out. PP to Line Out. SE to Line Out.
2.8+2.8 : 4 2.8+2.8 : 2 2.8 + 2.8 : 1 5.6 : 4
Primary DC current for 0.9 - - - 18 mA
Tesla
Primary Inductance 290 H 290 H 290 H 90H
Freq. Response (+/-1dB) @ Hz – kHz
source impedance (*) 15k 15k 15 k 3 k
Secondaries open
Max sec. voltage 380V r.m.s. 190V r.m.s. 100V r.m.s. 160 V r.m.s.
@ 30 Hz
Type LL2745/18mA LL2745/18mA (*) The source impedances used
Connection Alt Q Alt R in the tables indicates a
SE to Line Out. SE to Line Out. recommended upper limit, unless
5.6 : 2 5.6 : 1 freq. response can be
Primary DC current for 0.9 18 mA 18 mA compromised.
Tesla At lower source impedance
Primary Inductance 90H 90H resonance peaking will occure. It
Freq. Response (+/-1dB) @ can be reduced using secondary
source impedance (*) 3.5k 3.5k load resistors.
Secondaries open
Max output 80 V r.m.s. 40 V r.m.s.
R170628 PL
voltage @ 30 Hz
LUNDAHL
TRANSFORMERS

Tube Amplifier Interstage Transformer / Line Output Transformer


LL2745
Connection Alternatives

V+ V+

21 10 21 10
9 9
8 8
18 7 18 7

16 5 16 5
4 4
3 3
13 2 13 2

Alt. M Alt. P
2.8 + 2.8 : 4 (CT at 5) 5.6 : 4 (CT at 5)
Push-Pull to Line Output Single End to Line Output

V+ V+

21 10 21 10
9 9
8 8
18 7 18 7

16 5 16 5
4 4
3 3
13 2 13 2

Alt. N Alt. Q
2.8 + 2.8 : 2 (CT at 7+4) 5.6 : 2 (CT at 7 + 4)
Push-Pull to Line Output Single End to Line Output

V+
V+
21 10
9 21 10
8 9
18 7 8
18 7
16 5
4 16 5
3 4
13 2 3
13 2
Alt. O
2.8 + 2.8 : 1 Alt. R
Push-Pull to Line Output 5.6 : 1
Single End to Line Output

Phase Indicator

Das könnte Ihnen auch gefallen