Sie sind auf Seite 1von 3

Integrated Membranes Solutions Design Software, 2018

Created on: 14-11-2019 12:02:32

Basic Design
Project name 10000 LPH RO Page : 1/3
Calculated by ER. SAMBIT DE Permeate flow/train 10.00 m3/h
HP Pump flow 14.93 m3/h Raw water flow/train 14.93 m3/h
Feed pressure 15.1 bar Permeate recovery 67.00 %
Feed temperature 20.0 °C(68.0°F) Element age 2.0 years
Feed water pH 7.00 Flux decline %, per year 5.0
Chem dose, mg/l, - None Fouling factor 0.90
Specific energy 0.78 kwh/m3 SP increase, per year 7.0 %
Pass NDP 10.7 bar Inter-stage pipe loss 0.207 bar
Average flux rate 24.5 lmh
Feed type Brackish Well Non-Fouling

Pass - Perm. Flow / Vessel Flux DP Flux Beta Stagewise Pressure Perm. Element Element PV# x
Stage Flow Feed Conc Max Perm. Boost Conc TDS Type Quantity Elem #
m3/h m3/h m3/h lmh bar lmh bar bar bar mg/l
1-1 7.5 7.5 3.7 27.5 0.7 30.4 1.2 0 0 14.4 35.3 CPA2 8 2 x 4M
1-2 2.5 7.5 4.9 18.8 0.7 21.7 1.1 0 0 13.5 108.9 CPA2 4 1 x 4M
Permeate
Ion (mg/l) Raw Water Feed Water Water Concentrate 1 Concentrate 2
Hardness, as CaCO3 0.00 0.00 0.000 0.0 0.0
Ca 0.00 0.00 0.000 0.0 0.0
Mg 0.00 0.00 0.000 0.0 0.0
Na 1180.50 1180.50 21.267 2345.5 3538.6
K 0.00 0.00 0.000 0.0 0.0
NH4 0.00 0.00 0.000 0.0 0.0
Ba 0.000 0.000 0.000 0.0 0.0
Sr 0.000 0.000 0.000 0.0 0.0
H 0.00 0.00 0.003 0.0 0.0
CO3 0.00 0.00 0.000 0.0 0.0
HCO3 0.10 0.10 0.003 0.2 0.3
SO4 0.00 0.00 0.000 0.0 0.0
Cl 1819.50 1819.50 32.777 3615.1 5454.0
F 0.00 0.00 0.000 0.0 0.0
NO3 0.00 0.00 0.000 0.0 0.0
PO4 0.00 0.00 0.000 0.0 0.0
OH 0.00 0.00 0.000 0.0 0.0
SiO2 0.00 0.00 0.000 0.0 0.0
B 0.00 0.00 0.000 0.0 0.0
CO2 0.02 0.02 0.02 0.02 0.02
NH3 0.00 0.00 0.00 0.00 0.00
TDS 3000.10 3000.10 54.05 5960.84 8992.85
pH 7.00 7.00 5.49 7.17 7.33

Saturations Raw Water Feed Water Concentrate Limits


CaSO4 / ksp * 100, % 0 0 0 400
SrSO4 / ksp * 100, % 0 0 0 1200
BaSO4 / ksp * 100, % 0 0 0 10000
SiO2 saturation, % 0 0 0 140
CaF2 / ksp * 100, % 0 0 0 50000
Ca3(PO4)2 saturation index 0.0 0.0 0.0 2.4
CCPP, mg/l 0.00 0.00 0.00 850
Langelier saturation index 0.00 0.00 0.00 2.8
Ionic strength 0.05 0.05 0.15
Osmotic pressure, bar 2.3 2.3 7.0

Product performance calculations are based on nominal element performance when operated on a feed water of acceptable quality. The results shown on the printouts produced by this program are
estimates of product performance. No guarantee of product or system performance is expressed or implied unless provided in a separate warranty statement signed by an authorized Hydranautics
representative. Calculations for chemical consumption are provided for convenience and are based on various assumptions concerning water quality and composition. As the actual amount of chemical
needed for pH adjustment is feedwater dependent and not membrane dependent, Hydranautics does not warrant chemical consumption. If a product or system warranty is required, please contact your
Hydranautics representative. Non-standard or extended warranties may result in different pricing than previously quoted. Version : 2.226.84 %

Email : imsd-support@hydranauticsprojections.net
Integrated Membranes Solutions Design Software, 2018

Created on: 14-11-2019 12:02:32

Basic Design
Project name 10000 LPH RO Page : 2/3
Calculated by ER. SAMBIT DE Permeate flow/train 10.00 m3/h
HP Pump flow 14.93 m3/h Raw water flow/train 14.93 m3/h
Feed pressure 15.1 bar Permeate recovery 67.00 %
Feed temperature 20.0 °C(68.0°F) Element age 2.0 years
Feed water pH 7.00 Flux decline %, per year 5.0
Chem dose, mg/l, - None Fouling factor 0.90
Specific energy 0.78 kwh/m3 SP increase, per year 7.0 %
Pass NDP 10.7 bar Inter-stage pipe loss 0.207 bar
Average flux rate 24.5 lmh
Feed type Brackish Well Non-Fouling
Pass - Perm. Flow / Vessel Flux DP Flux Beta Stagewise Pressure Perm. Element Element PV# x
Stage Flow Feed Conc Max Perm. Boost Conc TDS Type Quantity Elem #
m3/h m3/h m3/h lmh bar lmh bar bar bar mg/l
1-1 7.5 7.5 3.7 27.5 0.7 30.4 1.2 0 0 14.4 35.3 CPA2 8 2 x 4M
1-2 2.5 7.5 4.9 18.8 0.7 21.7 1.1 0 0 13.5 108.9 CPA2 4 1 x 4M
Permeat Permeate
Pass - Element Feed Pressure Conc NDP e Water Water Beta Permeate (Stagewise cumulative)
Stage no. Pressure Drop Osmo. Flow Flux TDS Ca Mg Na Cl
bar bar bar bar m3/h lmh
1-1 1 15.1 0.23 2.7 12.5 1 30.4 1.14 20.7 0 0 8.13 12.531
1-1 2 14.9 0.18 3.2 11.8 1 28.5 1.16 24.2 0 0 9.505 14.649
1-1 3 14.7 0.14 3.8 11.1 0.9 26.7 1.17 28.8 0 0 11.337 17.472
1-1 4 14.5 0.11 4.6 10.3 0.8 24.4 1.2 35.3 0 0 13.88 21.39

1-2 1 14.2 0.23 5.1 9.2 0.7 21.7 1.1 80.3 0 0 31.613 48.725
1-2 2 14 0.2 5.7 8.5 0.7 19.9 1.1 88.5 0 0 34.82 53.667
1-2 3 13.8 0.17 6.3 7.7 0.6 17.8 1.1 97.9 0 0 38.534 59.391
1-2 4 13.6 0.14 7 6.9 0.5 15.8 1.1 108.9 0 0 42.83 66.014

Product performance calculations are based on nominal element performance when operated on a feed water of acceptable quality. The results shown on the printouts produced by this program are
estimates of product performance. No guarantee of product or system performance is expressed or implied unless provided in a separate warranty statement signed by an authorized Hydranautics
representative. Calculations for chemical consumption are provided for convenience and are based on various assumptions concerning water quality and composition. As the actual amount of chemical
needed for pH adjustment is feedwater dependent and not membrane dependent, Hydranautics does not warrant chemical consumption. If a product or system warranty is required, please contact your
Hydranautics representative. Non-standard or extended warranties may result in different pricing than previously quoted. Version : 2.226.84 %

Email : imsd-support@hydranauticsprojections.net
Integrated Membranes Solutions Design Software, 2018

Created on: 14-11-2019 12:02:32

Basic Design
Project name 10000 LPH RO Page : 3/3
Temperature : 20.0 °C Element age, P1 : 2.0 years

Stream No. Flow (m3/h) Pressure (bar) TDS (mg/l) pH Econd (µs/cm)
1 14.9 0 3000 7.00 5490
2 14.9 15.1 3000 7.00 5490
3 7.47 14.4 5961 7.17 10283
4 4.92 13.5 8993 7.33 15032
5 7.46 0 35.3 5.31 78.0
6 2.55 0 109 5.79 236
7 10.0 0 54.0 5.49 118

Product performance calculations are based on nominal element performance when operated on a feed water of acceptable quality. The results shown on the printouts produced by this program are
estimates of product performance. No guarantee of product or system performance is expressed or implied unless provided in a separate warranty statement signed by an authorized Hydranautics
representative. Calculations for chemical consumption are provided for convenience and are based on various assumptions concerning water quality and composition. As the actual amount of chemical
needed for pH adjustment is feedwater dependent and not membrane dependent, Hydranautics does not warrant chemical consumption. If a product or system warranty is required, please contact your
Hydranautics representative. Non-standard or extended warranties may result in different pricing than previously quoted. Version : 2.226.84 %

Email : imsd-support@hydranauticsprojections.net