Principle

King Cloud & Pour Point Bath: The King Cloud &
Pour Point Bath measures the low temperature cloud point and pour point of petroleum
products—an index of the lowest temperature of its utility for certain applications. There are
currently no ASTM methods for automated D97 Pour Point measurements. The CP610
offers the manual testing technique and a self-contained refrigeration system with ramp/
soak temperature programming ability. This standard King instrument is a cost effective and
user friendly alternative to expensive automated devices.
ASTM D97
Pour Point
History
ASTM D2500
The D97 Pour Point method was originally approved by ASTM in 1927 and is still used today Cloud Point
as the manual technique for pour point testing. After preliminary heating, the sample is
cooled at a specified rate and examined at intervals of 3°C for flow characteristics. The low- ASTM D5853
est temperature at which movement of the sample is observed is recorded as the pour Pour Point of Crude Oils
point.
The Cloud Point (D2500) test method for petroleum products and biodiesel fuels was Additional
originally approved in 1966. The cloud point is the temperature of a liquid sample when the International
smallest observable cluster of hydrocarbon crystals first appears at the bottom of the test Specifications:
jar when cooled under prescribed conditions and examined periodically. The intent of the
cloud point is to capture the temperature at which the liquids in the sample begin to IP 15
change from a single liquid phase to a two-phase system containing solid and liquid. IP 219
Features IP 441
DIN 51597
 Large illuminated viewing window with top-heating frost reduction system. JIS K2269
 Easily removable sleeves furnished with corks, felt sleeves, and retainer rings. ISO 3015
 Completely self-contained – no additional heating or cooling units needed.
ISO 3016
 Digital microprocessor temperature control for accurate, easy-to-read bath temperature.

 Wide range of bath temperature choices (+30°C


to –70°C).
 Precise temperature control and stability +/- 0.1°C.
 Ramp/Soak temperature programming ability.
 Built-in safety features for over temperature and low liquid level conditions.
 Monitoring temperature probe port.
 Worldwide electrical compatibility.
 One year warranty on all parts and labor.

The CP610 Carousel holds up to four (4) Cloud & Pour Point
samples at a time.

KING REFRIGERATION, INC.


TannasKing.com +1 989 698 5500
4800 James Savage Rd.
sales@kingrefrigeration.com +1 989 496 3438
Midland, MI 48642 USA
ISO 9001:2015 QMS

Parts & Accessories Instrument Specifications

950326: Copper Sleeve Dimensions Benchtop: 42 x 53 x 66 cm


(W x D x H) (16.5 x 21 x 26 inches)
950322: Test Jar
Weight ~ 68 kg | (150 lbs.)
950321: Test Jar Stopper—Pierced Cork
Voltage 208 to 220 VAC, 10 Amp.
950327: Cork Ring
Frequency 50 or 60 Hz., Single-Phase
950317: Cork Solid
Cooling Capacity 600 Watts at 0°C | 300 Watts at –40°C | 100 Watts at –70°C
950313: Test Hole Stoppers
Temp. Range +30°C to –70°C (86°F to –94°F)
350190: Desiccant Assembly
550175: Desiccant Media (1 lb. | 0.45 kg) Temp. Control ± 0.1°C Digital
Cooling Rate ~30°C/ hour average
Refrigerant R507 HFC / R508B
Viewing Window ~41 x 23 cm | 16 x 9 inches
Testing Capacity Four (4) sample Carousel
Cabinet Material Powder Coated Aluminum
Bath Size ~ 3.8 liters (1 gallon)
Bath Design Methanol or Ethanol within Dewar flask
High pressure cutout
Safety Low Level Indicator & Very Low Level Safety Shutdown
High temperature limit
Shipping Weight ~ 122 - 136 kg | (270 - 300 lbs.)
Shipping 81 x 76 x 104 cm
Dimensions (32 x 30 x 41 inches)
(W x D x H)

Accessories include Copper Sleeves, Glass Stators, Foam Insulating


Inserts, Cork Rings & Discs, Felt Sleeves, and Test Jar Stoppers.

Additional KING REFRIGERATION Precision Laboratory Instruments

Brookfield Liquid Bath (BLB) Mini-Rotary Viscometer (MRV TP-1) Kinematic Viscosity (KV Bath)
 ASTM D2983 | IP 267 | DIN 51398  ASTM D3829, D4684, D6821  ASTM D445, D2170, D6074 | IP 71
®
 Innovative SimAir Test Cells  Determines borderline pumping temperatures  ISO3105 | DIN 51550 | JIS K2283
 Models: BLB701, BLB702, BLB DIN  Direct Refrigeration Technology  Low & high temperature models available

KING REFRIGERATION, INC.


TannasKing.com +1 989 698 5500
4800 James Savage Rd.
sales@kingrefrigeration.com +1 989 496 3438
Midland, MI 48642 USA
© 2018 Tannas Co. | CP610-04 | Printed in USA