Sie sind auf Seite 1von 2

NEW SERIES AIR QUALITY MONITORING SYSTEMS

Chemiluminescent Nitrogen Oxides Analyzer


AC32e

label: Follow the green line

SPECIFIC FEATURES:
  E xcellent metrological performances for NO, NO 2 and NOx
measurements in the range 0-1 ppm or 0-10 ppm
  Innovative conception of the PM module for excellent sensitivity and
signal stability
ESA ConnectTM   Simultaneous multi-screen remote access via WiFi or LAN using the dedicated
ESA ConnectTM application (control, diagnostics, software update...)
  ESA ConnectTM application for iOS and Android available for free download
  Real-time calibration graph, animated synoptic, auto-diagnostic,
control and maintenance data screens can be displayed while the
instrument is operating
  Service assistant inside: detects early signs of trouble, allows predictive
Adopt the no-screen version of the analyzer and avoid
maintenance, identifies the needed service and guides service
the pollution related to the screen manufacturing and
recycling cycle. The analyzer is connected with your operations step by step: increased productivity on site, reduced
device (computer, smart-phone or tablet) downtime, more efficiency, less training...
  Includes embedded Communication Protocol for XR® Management
E-SERIES ADVANTAGES: Software with automatic recognition & configuration
Environmental friendly:
• Sustainable eco-design   Ultra low power consumption: an environment-friendly and cost-
• Low carbon footprint saving analyzer
• Over 95% of the analyzer can be recycled
• Ultra low power consumption   Breakthrough mechanical design for weight and power saving as well
• No use of heavy metals (e.g. Mercury) as thermal insulation & reliability
Long lifespan, excellent accuracy
Reliable electronics   Automatic recognition of plugged electronic boards or optional
Economic, Easy and reduced maintenance devices: plug & play principle
Common electronic boards: optimized spare

parts stock   SmartStatusLightTM power button on the front panel indicating if the
Service Assistant inside instrument is ready to use or not (ON/OFF, Alarm, Maintenance required…)
Interactivity: connected instruments

COMPLIANCE WITH: MAIN APPLICATIONS:


ISO 7996, EN 14211 (2012), EN 15267 (2009),
40 CFR PART 53 & PART 58 •  Continuous indoor and outdoor air quality monitoring
•  Stationary and mobile AQMS laboratories
•  Industrial fence-line monitoring
•  Continuous emissions monitoring (CEM) by dilution
•  Background (urban or suburban), Rural, Traffic, Kerbside measurement
TÜV RHEINLAND U.S. ENVIRONMENTAL
QAL 1 Certified PROTECTION AGENCY campaigns and monitoring studies
Certificate N° APPROVAL •  Laboratory and field studies on pollution effects...
0000053805 RFNA-0118-249

www.envea.global
Direct NO measurement NO, NO & NOx analyzer
Chemiluminescent
2
2

SPECIFICATIONS: PRINCIPLE OF OPERATION:


  Measurement Range: 0-1 ppm / 0-10 ppm The AC32e is a continuous ambient air-quality monitoring analyzer based on the
(user selectable & programmable) chemiluminescence principle, a standard method for the measurement of NO and
  Detection limit (2s): <0.2 ppb NO2 concentrations (EN 14211).
  Noise: <0.1 ppb
The chemiluminescence principle is used for an automatic analysis of the NO, NOx
  Zero drift: <1 ppb / 24h
and NO2 concentrations within a gaseous sample. The reaction between NO and O3
  Span drift: <1 ppb / 7 days (ozone), which is the basis for the CLD (chemiluminescence detector), emits photons
  Response time: min 40 sec (light) that are detected by a cooled photomultiplier tube (PMT).
(automatic and/or programmable)
NO + O3 a NO2* + O2
  Linearity: 1%
NO2* a NO2 + hu
  Repeatability: 1%
  Sample flow-rate: 0.66 l/min (1l/min with The CLD output voltage is proportional to the NO concentration. The light-producing
sample dryer option) reaction is very rapid, so a highly responsive instrument is suitable for good measurements.
  Operating temperature: 0-40°C In order to measure the NO2 concentration within the sample, it must first be reduced
  Chamber pressure: absolute 200 hPa into NO form, and this is achieved with a heated molybdenum NOx converter.
  NOx converter: Molybdenum Mo + 3NO2 a MoO3 + 3NO

Environnement S.A has a policy of continuous improvement of its products and we reserve the right to upgrade or change specifications without prior notice.
(regulated at 340°C) NO cycle: The sample moves directly into the reaction chamber where NO oxidation
  Ozone scrubber: heated catalytic by ozone takes place. The photomultiplier tube signal, minus the black signal, is
  P.M temperature: controlled at 0°C proportional to NO molecule number within the sample.
  Reaction chamber temperature: 60°C
AC32e Operating Principle - NO cycle
  External vacuum pump
  Data storage: 1 year (1 minute data)
  Output connectivity:
• Ethernet (RJ45 socket, UDP protocol,
Modbus TCP) 1 3

• USB port 6
7
2 4 8
• External zero/span SV control 5

  Integrated web-server with full remote 15


emulation of the analyzer 11

  Filter valve block for calibration control 14 9


12 10
(zero & span) 13

  Dimensions (mm, LxWxH): 483x545x133


  Chassis: 19’’ rack, 3U
  Weight: 10 kg without external pump (4.5 kg)
  Power supply: 100~250 V, 50/60 Hz
  Power consumption: 160 VA (average) 250
(1) Zero filter (6) reaction chamber (11) O3 restrictor
VA (peak) (2) zero SV (7) optical filter (12) O3 purifier
(3) sample restrictor (8) photomultiplier enclosure (13) O3 generator
(4) NOx converter oven (9) external vacuum pump (14) air inlet
(5) NOx cycle SV (10) O3 scrubber (15) sample inlet
MAIN OPTIONS:
  7’’ TFT color touch screen For the NOx cycle the sample passes through the converter oven which reduces NO2
  WiFi module (in standard with the to NO, then it is mixed with ozone in the reaction chamber. The photomultiplier tube
signal, minus the black signal, is proportional to the sum of NO and NO2 molecule
no-screen version)
(reduced to NO in the converter) contained in the sample.
  Serial interface (via 2 USB ports)
  NH3 module
The new AC32e analyzer combines 30 years of experience with its predecessors
  NO2 permeation bench and internal pump (AC32M, AC31M & AC30M), with the innovative features of the e-Series design. The
  Sample dryer outcome is a state-of-the-art instrument with reduced and easier maintenance and
  External opto-isolated I/O interface with: the topmost metrological capacities.
• 4 independent analog inputs
• 4 independent analog outputs Engineered with breakthrough technologies, the e-Series achieves a previously
• 4 remote control inputs unreachable level of autonomy: it integrates self diagnosis and a high level of self-
• 6 dry contacts outputs operation. Each analyzer is continuously self-monitored for performance and fault
control: detecting early signs of trouble, identifies the needed service and even guides
the service operations!

Distributed by:
The e-Series of analyzers has been fully eco-designed, with a special
AC32e-EN-0218

consideration to the environmental impacts of the product during its whole


life-cycle. The exclusive "inside the box" foam modular concept makes the
product more robust, power saving, simpler to service and eco-friendly.

Detailed information related in the e-Series brochure

111 Bb Robespierre / CS 80004


78304 Poissy CEDEX 4 - FRANCE
Tel. : +33(0)1 39 22 38 00
Web : www.envea.global
E-mail : info@environnement-sa.com