All time delays specified after the Function Set are based
Special case of 'Function Set'
on worst case instruction execution time (clock may be as 0011 (lower four bits are irrelevant)
low as 190 kHz).
Wait for more than 100 µs
0000
'Clear Display'
(no configurable bits )
At this point the device switches to the 4- 0001
bit mode.
Wait for more than 3 ms
or until busy flag is clear
Beyond this point the device reads only
the upper four data pins each time the
enable pin is pulsed. 0000
'Entry Mode Set'
The device will temporarily store the first (I/D and S as required )
group of four data bits that it receives.
0 1 I/D S
After it receives the second group of four Wait for more than 53 µs
data bits it will reassemble them and or until busy flag is clear
execute the resulting instruction.
0000
'Display ON/OFF Control'
(D=1, C and B as required )
11CB
Wait for more than 53 µs
or until busy flag is clear LCD 4-bit Initialization.vsd
This work is licensed under the Creative Commons Attribution-ShareAlike License.
Copyright © 2009, 2010
To view a copy of this license, visit http://creativecommons.org/licenses/by-sa/3.0/
Donald Weiman 20 November 2010