Sie sind auf Seite 1von 2

3F Condulet® EAB Series Cl. I, Div.

1 & 2, Groups A, B, C, D
Cl. II, Div. 1, Groups E, F, G
Explosionproof
Dust-ignitionproof
3F
Conduit Outlet Boxes Cl. II, Div. 2, Groups F, G Raintight
Cl. III Wet Locations
with Covers NEMA 3, 4, 7ABCD, 9EFG

Applications: Options:
EAB Series Conduit Outlet Boxes are Description Suffix
installed in conduit systems within • Bodies – copper-free aluminum............ SA
hazardous areas to:
• Covers – Feraloy iron alloy................ WOD
• Provide protection against exterior Electrogalvanized and aluminum acrylic paint
explosion where acetylene, hydrogen and finish
other hazardous gases are present
• Corro-free™ epoxy powder coat.......... S752
• Protect conductors in threaded rigid
conduit
Ordering Information:
• Act as pull and splice boxes
• Interconnect lengths of conduit EABC EABY
• Change conduit direction
• Provide access to conductors for
maintenance and future system changes

Features:
EAB Series Conduit Outlet Boxes have:
Hub Size Cat. #
• Five different hub configurations Hub Size Cat. # 1
/2” EABY16
• Taper threaded hubs to provide ground /2” 3
/4” EABY26
1
EABC16A
continuity 3
/4” EABC26A
• Smooth integral hub bushing to protect 1” EABC36A Replacement Cover
conductor insulation when pulling
• Threaded cover openings EABT Size Cat. #

• Surface covers furnished with boxes 3” EAB06


• Neoprene o-ring gasket and green ground
screw are both standard Replacement O-ring Gasket
• Four standard mounting pads, except for Description Cat. #
EABY Replacement O-ring GASK1151
• Cover threads are 16 pitch
• Internal green ground screw #10 Fixture Cover
Hub Size Cat. # Union Hub Type
Certifications and 1
/2” EABT16A
Compliances: 3
/4” EABT26A
1” EABT36A
NEC/CEC:
• Class I, Divisions 1 & 2, Groups A, B, C, D EABL
• Class II, Division 1, Groups E, F, G
• Class II, Division 2, Groups F, G
• Class III
UL Standard: Cover Fixt. Stem
Opening Dia. Size Cat. #
• UL1203
3” 3
/4 EAB0687B
CSA Standard:
• C22.2 No. 30
Hub Size Cat. #
Dimensions (in Inches):
Standard Materials: /2”
1
EABL16A
•  Bodies – Feraloy® iron alloy /4”
3
EABL26A
1” EABL36A
• Covers – Copper-free aluminum
EABX
Standard Finishes:
•  Feraloy – electrogalvanized and aluminum
acrylic paint
• Aluminum – natural
Cat. # a b c d e f
Size Ranges: 16 33/4 217/32 11/2 3
/4 55/16 33/32
•  Hub – 1/2” to 1” 26 33/4 225/32 13/4 7
/8 59/16 33/32
• Cover opening – 3” diameter 36 33/4 225/32 13/4 7
/8 59/16 33/32
Hub Size Cat. #
AAvailable in copper-free aluminum. To order, add suffix 1
/2” EABX16A
‘SA’ to end of catalog number. 3
/4” EABX26A
BEAB0687 is listed for Groups C and D only. 1” EABX36A

58 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2016 Eaton


Condulet® EAB Series Conduit Outlet Boxes 3F

3F
Factory Installed Terminal Block Ordering Guide

Ordering Information:
DIN Rail Mounted Terminal Blocks
Electrical Specifications:
30 Amp, 150V, AWG 26-10
Cat. # Description

DIN Rail Mounted, 2 Terminal Blocks


DIN12 EAB (Shapes C, X, T, L)
Form 6 Cover Dia. Opening
DIN Rail Mounted, 3 Terminal Blocks
DIN13 EAB (Shapes C, X, T, L)
Form 6 Cover Dia. Opening
DIN Rail Mounted, 4 Terminal Blocks
DIN14 EAB (Shapes C, X, T, L)
Form 6 Cover Dia. Opening

Direct Mounted Terminal Blocks


Electrical Specifications:
30 Amp, 300V, AWG 26-10
Cat. # Description

Direct Mounted Terminal Block, 4 Terminal Blocks


TB14 EAB (Shapes C, X, T, L)
Form 6 Cover Dia. Opening
Direct Mounted Terminal Block, 6 Terminal Blocks
TB16 EAB (Shapes C, X, T, L)
Form 6 Cover Dia. Opening

www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2016 Eaton 59