Sie sind auf Seite 1von 12

TECHNICAL DATA SHEET

MTA
Denomination: MTA ANCHOR Codes: AM, MI

Reference: FT MTA-en Date: 26/06/17 Revision: 11 Page: 1 of 12

CHARACTERISTICS APPLICATIONS
• Functioning by roughness; • Structural fixings in uncracked
installation by controlled torque. concrete in indoor
• Using for medium loads. applications.
• Easy installation. • Safety fences.
• Use on non-cracked concrete • Fixings of steel beams,
channels, machinery, boilers,
• Use for static or cuasi-static
signals, etc.
loads.
• Fixings of wood structures to
• Versions in galvanized carbon
concrete.
steel and stainless steel.

RECOMENDED TENSION
BASE MATERIALS RESISTANCES IN UNCRACKED SIZES
CONCRETE [kg]

M6 - M24

DRILL CONDITION

APPLICATION EXAMPLES
TECHNICAL DATA SHEET

MTA
Denomination: MTA ANCHOR Codes: AM, MI

Reference: FT MTA-en Date: 26/06/17 Revision: 11 Page: 2 of 12

1. RANGE

ITEM CODE SIZES PICTURES COMPONENT MATERIAL

Wedgebolt Carbon steel, estampado, galvanized ≥ 5µm


Clip Carbon steel, galvanized ≥ 5µm
1 AM M6 a M24 Nut DIN 934 clase 6 ISO 898-1 galvanized ≥ 5µm
Washer DIN 125 o DIN 9021 galvanized ≥ 5µm

Wedgebolt Stainless steel, grade A2


Clip Stainless steel, grade A2
2 MI-A2 M6 a M20 Nut DIN 934 stainless steel, grade A2
Washer DIN 125 o DIN 9021 stainless steel, grade A2

2. ACCESORIES

ITEM CÓDE PICTURE DESCRIPTION

Tool for anchor fixing using percussion drilling machine


1 DOMTA

3. INSTALLATION DATA
TECHNICAL DATA SHEET

MTA
Denomination: MTA ANCHOR Codes: AM, MI

Reference: FT MTA-en Date: 26/06/17 Revision: 11 Page: 3 of 12

Standard embedment depth Reduced embedment depth

Minimum concrete

Minimum concrete
Embedment depth

Embedment depth
Installation torque

Minimum spacing
Maximum fixture

Maximum fixture
Nominal drill bit

Critical spacing

Critical spacing
Drill hole depth

Drill hole depth


Effective depth

Effective depth

Minimum edge
INSTALLATION PARAMETERS

Critical edge

Critical edge
thickness

thickness

thickness

thickness
distance

distance

distance
d0 Tinst hmin h1 hnom hef tfix Scr Ccr hmin h1 hnom hef tfix Scr Ccr Smin Cmin
Family Code Size
[mm] [Nm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
AM06045 M6 x 45 1
- - - - - - - 100 40 35 25 75 40 35 35
AM06055 M6 x 55 11
AM06060 M6 X 60 2
AM06065 M6 x 65 7
AM06070 M6 x 70 12
AM06080 M6 x 80 22
AM06085 M6 x 85 27
AM06090 M6 x 90 32
MTA
AM06100 M6 x 100 6 7 42
AM06110 M6 x 110 100 55 50 40 52 120 60 - - - - - - - 50 50
AM06120 M6 x 120 62
AM06130 M6 x 130 72
AM06140 M6 x 140 82
AM06150 M6 x 150 92
AM06160 M6 x 160 102
AM06170 M6 x 170 112
AM06180 M6 x 180 122
TECHNICAL DATA SHEET

MTA
Denomination: MTA ANCHOR Codes: AM, MI

Reference: FT MTA-en Date: 26/06/17 Revision: 11 Page: 4 of 12

Standard embedment depth Reduced embedment depth

Minimum concrete

Minimum concrete
Embedment depth

Embedment depth
Installation torque

Minimum spacing
Maximum fixture

Maximum fixture
Nominal drill bit

Critical spacing

Critical spacing
Drill hole depth

Drill hole depth


Effective depth

Effective depth

Minimum edge
INSTALLATION PARAMETERS

Critical edge

Critical edge
thickness

thickness

thickness

thickness
distance

distance

distance
d0 Tinst hmin h1 hnom hef tfix Scr Ccr hmin h1 hnom hef tfix Scr Ccr Smin Cmin
Family Code Size
[mm] [Nm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
AM08050 M8 x 50 40 35 23 4 75 40 30 30
AM08060 M8 x 60 - - - - - - - 3
50 47 35 105 53
AM08065 M8 x 65 8
AM08075 M8 x 75 5 18
AM08090 M8 x 90 8 20 20 100 33
65 65
AM08115 M8 x 115 45 58
100 65 59,5 48 144 72 50 47 35 105 53
AM08120 M8 x 120 50 63
AM08130 M8 x 130 60 73
MTA AM08155 M8 x 155 85 98
AM10065 M10 x 65 100 55 52 40 1 120 60 55 55
AM10070 M10 x 70 - - - - - - - 3
AM10080 M10 x 80 13
AM10090 M10 x 90 10 23
10 35
AM10100 M10 x 100 20 100 60 54 42 33 126 63 70 70
AM10120 M10 x 120 110 75 66,5 55 40 165 83 53
AM10140 M10 x 140 60 73
AM10150 M10 x 150 70 83
TECHNICAL DATA SHEET

MTA
Denomination: MTA ANCHOR Codes: AM, MI

Reference: FT MTA-en Date: 26/06/17 Revision: 11 Page: 5 of 12

Standard embedment depth Reduced embedment depth

Minimum concrete

Minimum concrete
Embedment depth

Embedment depth
Installation torque

Minimum spacing
Maximum fixture

Maximum fixture
Nominal drill bit

Critical spacing

Critical spacing
Drill hole depth

Drill hole depth


Effective depth

Effective depth

Minimum edge
INSTALLATION PARAMETERS

Critical edge

Critical edge
thickness

thickness

thickness

thickness
distance

distance

distance
d0 Tinst hmin h1 hnom hef tfix Scr Ccr hmin h1 hnom hef tfix Scr Ccr Smin Cmin
Family Code Size
[mm] [Nm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
AM10160 M10 x 160 80 93
AM10170 M10 x 170 90 103
10 35 110 75 66,5 55 165 83 100 60 54 42 126 63 70 70
AM10210 M10 x 210 130 143
AM10230 M10 x 230 150 163
AM12075 M12 x 75 60 55 43 5 130 65 60 60
AM12080 M12 x 80 - - - - - - - 3
AM12090 M12 x 90 13
AM12100 M12 x 100 8 23
MTA AM12110 M12 x 110 18 33
AM12120 M12 x 120 12 60 28 100 43
70 62 50 150 75 85 85
AM12140 M12 x 140 48 63
130 85 77 65 195 98
AM12160 M12 x 160 68 83
AM12180 M12 x 180 88 103
AM12220 M12 x 220 122 143
AM12250 M12 x 250 152 173
AM14080 M14 x 80 100 65 59 42 5 130 65 60 60
14 90 - - - - - - -
AM14100 M14 x 100 125 85 79 62 5 190 95 85 85
TECHNICAL DATA SHEET

MTA
Denomination: MTA ANCHOR Codes: AM, MI

Reference: FT MTA-en Date: 26/06/17 Revision: 11 Page: 6 of 12

Standard embedment depth Reduced embedment depth

Minimum concrete

Minimum concrete
Embedment depth

Embedment depth
Installation torque

Minimum spacing
Maximum fixture

Maximum fixture
Nominal drill bit

Critical spacing

Critical spacing
Drill hole depth

Drill hole depth


Effective depth

Effective depth

Minimum edge
INSTALLATION PARAMETERS

Critical edge

Critical edge
thickness

thickness

thickness

thickness
distance

distance

distance
d0 Tinst hmin h1 hnom hef tfix Scr Ccr hmin h1 hnom hef tfix Scr Ccr Smin Cmin
Family Code Size
[mm] [Nm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
AM14120 M14 x 120 12
AM14145 M14 x 145 37
AM14170 M14 x 170 14 90 150 100 91 75 62 225 113 - - - - - - - 100 100
AM14220 M14 x 220 112
AM14250 M14 x 250 142
AM16090 M16 x 90 4
- - - - - - - 100 75 69 49 150 75 65 65
AM16110 M16 x 110 24
AM16125 M16 x 125 3
MTA AM16145 M16 x 145 23
16 120
AM16170 M16 x 170 48
168 110 103,5 84 252 126 - - - - - - - 110 110
AM16220 M16 x 220 98
AM16250 M16 x 250 128
AM16280 M16 x 280 158
AM20120 M20 x 120 - - - - - - - 145 105 93 71 5 225 110 95 95
AM20170 M20 x 170 23
20 240
AM20220 M20 x 220 206 135 125 103 73 309 155 - - - - - - - 135 135
AM20270 M20 x 270 123
TECHNICAL DATA SHEET

MTA
Denomination: MTA ANCHOR Codes: AM, MI

Reference: FT MTA-en Date: 26/06/17 Revision: 11 Page: 7 of 12

Standard embedment depth Reduced embedment depth

Minimum concrete

Minimum concrete
Embedment depth

Embedment depth
Installation torque

Minimum spacing
Maximum fixture

Maximum fixture
Nominal drill bit

Critical spacing

Critical spacing
Drill hole depth

Drill hole depth


Effective depth

Effective depth

Minimum edge
INSTALLATION PARAMETERS

Critical edge

Critical edge
thickness

thickness

thickness

thickness
distance

distance

distance
d0 Tinst hmin h1 hnom hef tfix Scr Ccr hmin h1 hnom hef tfix Scr Ccr Smin Cmin
Family Code Size
[mm] [Nm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
AM24180 M24 x 180 4
MTA 24 350 250 160 150 123 370 185 - - - - - - - 160 160
AM24260 M24 x 260 84
MI06045 M6 x 45 - - - - - - - 100 40 35 25 1 75 40 35 35
MI06060 M6 x 60 2
MI06080 M6 x 80 22
6 7
MI06120 M6 x 120 100 55 50 40 62 120 60 - - - - - - - 50 50
MI06140 M6 x 140 82
MI06160 M6 x 160 102
MI08050 M8 x 50 - - - - - - - 40 35 23 4 75 40 30 30
MTA-A2
MI08075 M8 x 75 5 18
8 20 100
MI08090 M8 x 90 100 65 60 48 20 144 72 50 46,5 35 33 105 53 65 65
MI08115 M8 x 115 45 58
MI10070 M10 x 70 - - - - - - - 100 55 52 40 5 120 60 55 55
MI10090 M10 x 90 10 23
10 35
MI10120 M10 x 120 110 75 66,5 55 40 165 83 100 60 53,5 42 53 126 63 70 70
MI10150 M10 x 150 70 83
TECHNICAL DATA SHEET

MTA
Denomination: MTA ANCHOR Codes: AM, MI

Reference: FT MTA-en Date: 26/06/17 Revision: 11 Page: 8 of 12

Standard embedment depth Reduced embedment depth

Installation torque

Minimum spacing
Maximum fixture

Maximum fixture
Nominal drill bit

Critical spacing

Critical spacing
Drill hole depth

Drill hole depth


Effective depth

Effective depth

Minimum edge
Critical edge

Critical edge
Embedment

Embedment
INSTALLATION PARAMETERS

thickness

thickness

thickness

thickness
Minimum

Minimum
concrete

concrete
distance

distance

distance
depth

depth
d0 Tinst hmin h1 hnom hef tfix Scr Ccr hmin h1 hnom hef tfix Scr Ccr Smin Cmin
Family Code Size
[mm] [Nm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
MI12075 M12 x 75 100 60 55 43 5 130 65 60 60
- - - - - - -
MI12090 M12 x 90 120 75 70 58 5 175 90 75 75
12 60
MI12110 M12 x 110 18 33
130 85 77 65 195 98 100 70 62 50 150 75 85 85
MI12140 M12 x 140 48 63
MI16090 M16 x 90 - - - - - - - 100 75 69 49 4 150 75 65 65
MTA-A2
MI16145 M16 x 145 16 120 23
168 110 103,5 84 252 126 - - - - - - - 110 110
MI16170 M16 x 170 48
MI20120 M20 x 120 - - - - - - - 145 105 93 71 5 225 110 95 95
MI20170 M20 x 170 20 240 23
206 135 125 103 309 155 - - - - - - - 135 135
MI20220 M20 x 220 73

Critical distances are those where anchors in a group are not influenced by one another with regard to tension load effects. For smaller distances, down to minimum
distances, corresponding reduction coefficients must be applied.
TECHNICAL DATA SHEET

MTA
Denomination: MTA ANCHOR Codes: AM, MI

Reference: FT MTA-en Date: 26/06/17 Revision: 11 Page: 9 of 12

4. PRODUCT INSTALLATION

1. DRILLING
Check the concrete base is compact and porosity is insignificant
Suitable for wet, dry or flooded drill holes.
Use drill in hummer mode.
Drill to the specified diameter and depth values.

2. BLOW AND CLEAN


Clear the drill holes completely of dust and fragments
Use air pump and brush.

3. INSTALL
Insert the anchor in the hole until the red ring mark is flat with concrete surface.
Use hummer in case of need; DOMTA tool could be used alternatively.
The installation could be done through the fixture baseplate.

4. APPLY TORQUE
Apply nominal installation torque using a torque wrench.

Once installed it can be verified the total length of the anchor through the letter on bolt tip.

5. RESISTANCES

Characteristic resistances for C20/25 uncracked concrete for an isolated anchor (without considering anchor-to-
anchor or anchor-to-edge distance effects).

Standard embedment depth Reduced embedment depth


Resistances values
Tension Shear Tension Shear
Safety factor Safety factor
NR,k VR,k NR,k VR,k
Family Code Size
[kN] [kN] Tension Shear [kN] [kN] Tension Shear
AM06045 M6 x 45
- - - - 6,3 5,1 1,5 1,25
AM06055 M6 x 55
AM06060 M6 X 60
AM06065 M6 x 65
AM06070 M6 x 70
MTA AM06080 M6 x 80
AM06085 M6 x 85 7,7 5,1 1,4 1,25 - - - -
AM06090 M6 x 90
AM06100 M6 x 100
AM06110 M6 x 110
AM06120 M6 x 120
TECHNICAL DATA SHEET

MTA
Denomination: MTA ANCHOR Codes: AM, MI

Reference: FT MTA-en Date: 26/06/17 Revision: 11 Page: 10 of 12

Standard embedment depth Reduced embedment depth


Resistances values
Tension Shear Tension Shear
Safety factor Safety factor
NR,k VR,k NR,k VR,k
Family Code Size
[kN] [kN] Tension Shear [kN] [kN] Tension Shear
AM06130 M6 x 130
AM06140 M6 x 140
AM06150 M6 x 150
7,7 5,1 1,4 1,25 - - - -
AM06160 M6 x 160
AM06170 M6 x 170
AM06180 M6 x 180
AM08050 M8 x 50 5,6 5,6
AM08060 M8 x 60 - - - -
AM08065 M8 x 65
AM08075 M8 x 75
AM08090 M8 x 90 1,5 1,5
9,0 10,4
AM08115 M8 x 115
12,0 9,3 1,5 1,25
AM08120 M8 x 120
AM08130 M8 x 130
AM08155 M8 x 155
AM10065 M10 x 65 - - - - 12,8 12,8 1,8 1,5
AM10070 M10 x 70
AM10080 M10 x 80
AM10090 M10 x 90
AM10100 M10 x 100
MTA
AM10120 M10 x 120
AM10140 M10 x 140 16,0 14,7 1,8 1,25 12 13,7 1,5 1,5
AM10150 M10 x 150
AM10160 M10 x 160
AM10170 M10 x 170
AM10210 M10 x 210
AM10230 M10 x 230
AM12075 M12 x 75 - - - - 14,2 14,2 1,8 1,5
AM12080 M12 x 80
AM12090 M12 x 90
AM12100 M12 x 100
AM12110 M12 x 110
AM12120 M12 x 120
25,0 20,6 1,8 1,25 16,0 17,8 1,5 1,5
AM12140 M12 x 140
AM12160 M12 x 160
AM12180 M12 x 180
AM12220 M12 x 220
AM12250 M12 x 250
AM14080 M14 x 80 13,7 13,7 1,8 1,5
- - - -
AM14100 M14 x 100 24,6 28,1 1,8 1,25
TECHNICAL DATA SHEET

MTA
Denomination: MTA ANCHOR Codes: AM, MI

Reference: FT MTA-en Date: 26/06/17 Revision: 11 Page: 11 of 12

Standard embedment depth Reduced embedment depth


Resistances values
Tension Shear Tension Shear
Safety factor Safety factor
NR,k VR,k NR,k VR,k
Family Code Size
[kN] [kN] Tension Shear [kN] [kN] Tension Shear
AM14120 M14 x 120
AM14145 M14 x 145
AM14170 M14 x 170 30,0 28,1 1,8 1,25 - - - -
AM14220 M14 x 220
AM14250 M14 x 250
AM16090 M16 x 90
- - - - 17,3 17,3 1,8 1,5
AM16110 M16 x 110
AM16125 M16 x 125
AM16145 M16 x 145
MTA AM16170 M16 x 170
35,0 38,4 1,8 1,25 - - - -
AM16220 M16 x 220
AM16250 M16 x 250
AM16280 M16 x 280
AM20120 M20 x 120 - - - - 30,2 60,3 1,8 1,5
AM20170 M20 x 170
AM20220 M20 x 220 50,0 56,3 1,8 1,25 - - - -
AM20270 M20 x 270
AM24180 M24 x 180
65,3 81,2 1,8 1,25 - - - -
AM24260 M24 x 260
MI06045 M6 x 45 - - - - 6,3 6,0 1,5 1,52
MI06060 M6 x 60
MI06080 M6 x 80
MI06120 M6 x 120 10,1 6,0 1,68 1,52 - - - -
MI06140 M6 x 140
MI06160 M6 x 160
MI08050 M8 x 50 - - - - 5,6 5,6 1,5 1,5
MI08075 M8 x 75
MI08090 M8 x 90 12,0 10,9 1,8 1,52 9,0 10,4 1,8 1,5
MI08115 M8 x 115
MTA-A2 MI10070 M10 x 70 - - - - 12,8 12,8 1,8 1,5
MI10090 M10 x 90
MI10120 M10 x 120 16,0 17,4 1,8 1,52 12,0 13,7 1,8 1,5
MI10150 M10 x 150
MI12075 M12 x 75 14,2 14,2 1,8 1,5
- - - -
MI12090 M12 x 90 22,3 22,3 1,8 1,5
MI12110 M12 x 110
25,0 25,2 1,8 1,52 16,0 17,8 1,8 1,5
MI12140 M12 x 140
MI16090 M16 x 90 - - - - 17,3 17,3 1,8 1,5
MI16145 M16 x 145
35,0 47,1 1,8 1,52 - - - -
MI16170 M16 x 170
TECHNICAL DATA SHEET

MTA
Denomination: MTA ANCHOR Codes: AM, MI

Reference: FT MTA-en Date: 26/06/17 Revision: 11 Page: 12 of 12

Standard embedment depth Reduced embedment depth


Resistances values
Tension Shear Tension Shear
Safety factor Safety factor
NR,k VR,k NR,k VR,k
Family Code Size
[kN] [kN] Tension Shear [kN] [kN] Tension Shear
MI20120 M20 x 120 - - - - 30,2 60,3 1,8 1,5
MTA-A2 MI20170 M20 x 170
50,0 73,5 1,8 1,52 - - - -
MI20220 M20 x 220

1 KN ≈ 100 kg

A load safety factor of γF = 1,4 is recommended

Concrete increasing coefficient:

Concrete class Coefficient

C30/37 1,22
C40/50 1,41
C50/60 1,55

Design example:
Fixing a tension load of 1.500 kg (= 14,71 kN) in C30/37 uncracked concrete using a M16 AM16145
anchor.
Check to be done: Design load < Design resistance
Design load = service load * load safety factor = 14,71 * 1,4 = 20,60 kN
Design resistance = characteristic resistance * concrete coefficient / tension partial safety coefficient =
35,0 * 1,22 / 1,8 = 23,73 kN
Check: 20,60 kN < 23,73 kN: anchorage is safe.

For complex anchor designs we recommended our anchor design software INDEXcal.

Das könnte Ihnen auch gefallen